CONTENTS
3. Product Introduction 6
- Addressable Fire Controllers
- Bells
- T2000 System / MX
- Gas Detectors
tyco
Fire &
Security
Tyco Marine Services Korea
DongBang Electronic Ind. Co., Ltd.
Tyco Marine Services Korea
We keep our business simple. We stay close to our markets and our customers.
These strategies are at the root of Tyco's growth, which we achieve both organically and through acquisitions.
We hope you find everything you need while visiting us today. If you have any questions, please feel free to
contact us.
Our investor relations and business development professionals are happy to assist you.
40
3 6 .3
ㆍ The 28th largest company in the world*
30 2 8 .9
ㆍ Establishment : In 1960
2 2 .5
20 1 9 .1
ㆍ Total Annual Turnover : US$ 36.3 Bn 1 6 .7
US$
ㆍ Employees : 240,000+ 10
in Billions
ㆍ Subsidiaries : 400 in 100 countries 0
97 98 99 00 01
3
tyco Fire &
Securit
y
World-wide Services
Tyco’s Marine Group is one of the largest solution providers to the marine industry. Our
marine products and solutions can be found on all types of vessels, including fighting
ships, gas carriers, tankers, container vessels, cruise liners and floating production units.
As a global manufacturer, Tyco can supply innovative solutions from one source to meet
marine approval requirements from Japan to the U.S.A. and from Finland to New Zealand.
We have also developed solutions to comply with future marine requirements, including local application
extinguishing, Halon replacement and more.
To ensure that your vessels are never far away from assistance, we provide worldwide service by trained Tyco
employees from selected Tyco offices around the world. Our commitment to the marine industry includes
support for systems installed over 25 years ago, together with planned upgrade paths. We operate a 24 hour
service, and spares are available from our warehouses worldwide.
RELATED PUBLICATIONS
ㆍFire Alarm System
ㆍFire Fighting System
ㆍFire Extinguishing Gas System
ㆍPrequalification Statements
The right is reserved to modify or withdraw any product or service without notice.
4
Tyco Marine Services Korea
Marine Fire Detection Systems including hazardous area equipment with PLC, ESD and PSD interface.
5
tyco Fire &
Securit
y
Addressable Fire Controllers
MINERVA Analogue Addressable Fire Controllers
MINERVA is a comprehensive and reliable range
of networkable analogue addressable fire
controllers with over 10,000 installations
worldwide. MINERVA complies with BS5839 Pt 4
and can be installed to BS5839 Pt. 1.
The controllers and ancillaries are LPCB and
Marine approved with various other international
cross listings.
Features
• 8, 16 & 80 Zone networkable controllers
• Seamless peer to peer networking
• Full function repeaters
• LPCB Approved
• T890/891 Marine Approved variants
• NEW Mandarin option
• Loop power sounder options
• Wide range of addressable devices
• Conventional system upgrade path
• Twin microprocessor watchdog function
• Continuous and pulsing sounders
Technical Specification
• Programmable mapping of signals for
LPCB Approved MINERVA 8 MINERVA 16E MINERVA 80 controlled evacuation
Marine Approved (Note4) - T891M T890M
• On-site software configuration
Zones 8 16 80
• Powerful cause and effect software
Points 99 198 990 programming
Zonal LED Display 8 16 80 • Remote printer, mimic and VDU options
LCD Display 80 Character 80 Character 80 Character • 500 event memory
• Pre-alarm capability
Sounder Circuits (2 off) 500mA each 500mA each 500mA each
• Threshold compensation for optimum detector
Alarm Relay (1 off) 30Vd.c. @1.5A 30Vd.c. @1.5A 30Vd.c. @1.5A performance
Fault Relay (1 off) 30Vd.c. @1.5A 30Vd.c. @1.5A 30Vd.c. @1.5A • Detector condition monitoring advises when
detector servicing is required
Product Codes
• Weekly test reminder and walk test facility
Control Panel Surface Mounting 557.180.564 557.180.550 557.180.556
• Addressable intrinsically safe System 602
Control Panel Flush Mounting 557.180.565 557.180.553 557.180.557 • Surface and flush mount options
Marine Panel - 557.180.402 557.180.401 Technical Specification (Excludes Marine)
Repeater Panel Surface Mounting 557.180.566 557.180.554 557.180.558 Dimensions: 320H x 440W x 140D mm
Repeater Panel Flush Mounting - 557.180.555 557.180.559 Approx. Weight: 7Kg
Colour: Dawn Grey BS4800 10-A-03
Marine Repeaters (T290/291) - 557.180.404 557.180.403
Installation: Surface or Semi-flush
Special Control Panel Variants - Operating Temp: -10°C to + 55°C
Loop Powered Surface Mnt Panel Note 3 Note 3 557.180.569 Storage Temp: -20°C to + 65°C
Humidity: Up to 95% RH (Noncondensing)
Loop Powered Flush Mnt Panel Note 3 Note 3 557.180.570
Housing Protection: IP43
Panel with Arabic overlay - 557.180.568 557.180.567
Mains Supply: 110V-120V/220V-240V a.c.
Panel with Dutch overlay 557.180.701 557.180.703 557.180.702 ± 10% at 50/60HZ ± 5%
Panel with Mandarin graphics display - 557.180.575 557.180.576 Secondary Supply: 24V d.c. Nominal
NOTE: A self contained 3 amp switch mode
Special Control Panel Variants
power supply together with 2 x 6 AH 12V or 2 x
Loop Powered Surface Mnt Panel Note 3 Note 3 557.180.569 10 AH 12V batteries may be fitted inside the main
Loop Powered Flush Mnt Panel Note Note 3 Note 3 557.180.570 housing of the MINERVA 8 or MINERVA 16E -
Panel with Arabic overlay - 557.180.568 557.180.567 (See Note 1 for battery fixing kits). The MINERVA
80 requires a separate housing for its power
Panel with Dutch overlay 557.180.701 557.180.703 557.180.702
supply. Batteries up to 2 x 15 AH 12V may also be
Panel with Mandarin graphics display - 557.180.575 557.180.576 fitted in this housing. See AC Power Module.
6
Tyco Marine Services Korea
Additional Components
Note 1 557.180.055 MINERVA 8 and 16E battery fixing kit.
557.180.065 MINERVA 80 battery fixing kit
557.180.410 T890 battery fitting kit
557.180.203 Loop Powered MINERVA 80 panels come complete with a special Loop Powered ALXM (loop card).
An additional loop power ALXM card (MINERVA-557.180.203) is required for each additional 2 loops.
557.180.014 ALXM (2 loop) expansion card for standard MINERVA 80
557.180.424 ALXM (2 loop) expansion card for T890
Note 3 557.180.092 MINERVA Loop powered insertion module converts MINERVA 8 and 16E to Loop Powered panels.
Note 4: 557.180.454 T890/891 Bulkhead mounting kit
557.180.405 T690M Marine Power Unit
MINERVA Repeaters
The MINERVA fully functional repeaters are The technical specification for the repeater is the
available for all models of the MINERVA series same as the main panel shown on the previous
controllers. The repeaters are LPCB approved page, product codes are also shown there.
and offer the same control and monitoring
facilities as the main panel. Each repeater
includes one MPIM Module and up to seven
repeaters can be attached to the remote bus of
the main panel.
16-WAY
ZONAL
DISPLAY
EXPANSION
BUS
TO PRINTER MAIN
PROCESSOR
REMOTE
BUS
CONTROLLER
DCCM
EXPANSION
BUS
SERIAL
PORT
MPIM
(PIB-R)
24V d.c
PARALLEL REMOTE
PORT BUS
TO PRINTER
REPEATER
7
tyco Fire &
Securit
y
Conventional Marine Panels (See also MINERVA Section)
T1000
• Can be used with a wide range of Minerva Product Codes
Marine approved Detectors 508.022.035
• 4 monitored Sounder outputs up to 4A T1008 8 zone marine NT conventional fire
• 4 monitored Relay outputs Controller
• 3 programmable auxiliary inputs 508.022.036
T1016 16 zone marine NT conventional fire
• 3 levels of alarm discriminations per zone Controller
• One common fault relay 508.022.037
• Programmable cause and effect T1016R repeater for use with T1008 & T1016
• Can interface to intrinsically safe System 601
• Manned/ unmanned mode Power Supply: 198 -264Va.c.
Quiescent Current: 50mA @ 24Vd.c.
Technical Specification Alarm Current: 1Amp @ 24Vd.c.
Dimensions: 320H x 430W x 150D mm Operating Temp: 0 to +40°C
Weight: 6.3kg Operating Humidity: 0-90% RH non-condensing
8
Tyco Marine Services Korea
• Two alarm levels per detection zone (except Nicad battery for total power fail warning (included
repeater unit or zonal mimic drive pcbs Zone output/ mimic drive pcb
9
tyco Fire &
Securit
y
T880 Thirty-Two Zone Conventional Marine Fire Controller
• Replaceable legend Product Codes
Other input/output facilities:- 508.013.012
Terminal Field A:- T880 Control Unit Deep
• Zone terminals 1-8 508.013.013
T880 Control Unit shallow
• Two monitored sounder circuits rated at
508.013.002
24Vd.c. 2.5A each.
T280 Repeater Unit
• One latching common alarm contact rated 3A 401.006.012 (Available from Thorn Marine)
@ 30Vd.c. resistive Sounder pulsing module
• One latching common fault contact rated 3A @ 400.007.003 (Available from Thorn Marine)
30Vd.c. T880 Handbook
Terminal Field E:- 401.011.008 (Available from Thorn Marine)
• Zone terminals 9 to 32 Bezel for deep housing
• 4 relays rated 1A @ 30Vd.c. resistive. The 401.011.009 (Available from Thorn Marine)
relays can be programmed to activate by Bezel for shallow housing
509.013.001
zone(s) with an additional zonal mimic drive
The T880 control unit forms the heart of a Nicad battery for total power fail warning (included
PCB,
sophisticated and flexible marine fire detection with new control panel)
Options:-
system. The T880 provides control of up to 32 509.013.002
• Optional lamp dim module used to provide a T880 front cover
conventional zones of fire detection. For
variable output to the controller lamp supply for 509.013.059
exceptionally large vessels, up to three controllers
dimming purposes. This is normally only Zone output/ mimic drive PCB
may be linked together to give 96 zones of fire
required if the system does not use a T680 509.013.062
detection. The T880 unit comprises, display and
power unit. Zone output PCB c/w ribbon connector
electronics PCB assembly, terminal field A and
• Optional sounder pulsing module to permit 509.013.048
terminal field E in either a deep or shallow Terminal Field A
predefined sounder circuit pulsing
housing. The deep housing permits the 509.013.061
configurations.
convenient installation of additional optional circuit Terminal Field E
• Optional Earth leakage monitor
boards in the same housing. The control panel 509.013.108
normally receives its power from the T680 power Lamp dim module
Technical Specification 509.013.055
changeover unit, or alternatively, the C2440, if
Operating temp.: -25°C to +70°C T880 Spares kit
ship's 24Vd.c. supply is not available.
Storage temp.: -25°C to +70°C 509.013.028
Features Humidity: 95% RH non-condensing T280 Spares kit
• Approved by a variety of marine authorities The control panel is normally mounted onto a 509.013.121
• Up to 32 fire detection zones bulkhead using the H frame bracket. Bezels for T880 variable legend kit
• Two alarm levels per detection zone (except both deep and shallow housings are available. T880 T880
I.S. zones) The deep housing has two removable gland Deep Shallow
• 2 monitored bell circuits selectable as plates (top and bottom) for cable access. The Size (mm) 267mm
continuous or intermittent shallow housing has eight 20mm knock outs, both Height 385 385
• Secondary alarm output delay (up to 3 mins) top and bottom.
Width 398 398
• Multiplexed data I/O Housing is zinc plated 1.6mm thick mild steel.
Depth 171 95
• Interfaces directly with up to four T280 32 zone Finish is grey epoxy powder paint 9-094, to
Weight Kg
repeater unit or zonal mimic drive PCB’s BS2660.
With H frame 15 10
• Panel test and isolate mode Front cover assembly moulded from a flame
Without H frame 11.5 6.5
• Can interface to intrinsically safe System 601 retardant polyester glass filled compound, finished
IP rating 53 53
• Lamp dim feature in blue-grey 9-098, to BS2660.
10
Tyco Marine Services Korea
Batteries
Product Codes 3071 560.001.015
660.001.003 Battery sealed L-A replaces 660.001.009 and 30- Battery sealed L-A also replaces 3148, SLA17
Battery sealed L-A 105 and 30-109
560.001.013 660.002.010 660.001.004
Battery sealed L-A also replaces parts 3145 and Battery sealed L-A also replaces 3146, SLA04 Battery sealed L-A (Bolt terminal) also replaces
30-102 and 30-112 3014, SLA24 and 30-106
3085 3072 560.001.012
Battery sealed L-A also replaces 660.001.014 and Battery sealed L-A also replaces 660.001.005, Battery sealed L-A also replaces 3149, SLA38
30-111 SLA07 and 30-101 and 30-107
3010 660.002.012 3150
Battery sealed L-A also replaces 660.001.007, Battery sealed L-A also replaces 3147, SLA012 Battery sealed L-A also replaces SLA65 and 30-
SLA21 and 30-103 and 30-110 108
11
tyco Fire &
Securit
y
Addressable 900 Series Detectors
Body Optical Ionisation HPO R of R Heat CO enabled the introduction of a smoke detector
Marine MR901M MF901M MD901 suitable for fast, reliable smoke detection of both
slow and fast developing fires. The H.P.O. can be
The M900 series are a range of low profile installation. This ensures that the detector seen as a truly universal smoke detector, suitable
addressable fire detectors. These unobtrusively addresses are not accidentally confused during for most applications.
styled detectors have a number of unique design service visits.
features to improve their operation, installation The M900 series includes the unique Carbon Features
and ease of servicing. Monoxide CO fire detector, which provides a • Unique early detection CO fire detector
Through innovative design the M900 Series general purpose fire detector with unprecedented • Intelligent Universal HPO Smoke Detector
detectors have reduced the installation and early detection capability and excellent false alarm • Low profile, discreet and unobtrusive
servicing time to a minimum, needing only one immunity. The CO fire detectors are the first • Superior performance and reliability
visit to complete the installation. The detectors choice for sleeping risks. • Unique ‘Smart Key’ feature
also have a park position, which eases detector Also included within the range is the intelligent • Designed for fast, easy installation
servicing. high performance optical smoke (H.P.O.) detector. • Optional Locking Kit
The unique smart key feature ensures that the The use of the patented optical sensing chamber, • Integral and remote alarm LED
address is transferred to the base after together with refined signal processing, has • Series of Product Approvals
Optical Smoke
These detectors are capable of Product Codes Approval Branded Model
detecting the visible smoke 516.057.401 Marine Thorn MR901M
produced by materials which
smoulder or burn slowly, i.e. soft asymmetrical sampling chamber and signal
furnishings, plastic foam etc;. or processing techniques stop unwanted alarms
smoke' produced by overheated but unburnt PVC. caused by very small insects. i.e. thrips. Smoke
These detectors are particularly suitable for entering the sampling chamber scatters the
general applications and areas where cable infrared light pulses onto a photodiode These
overheating may occur e.g. electrical services pulses are converted to an electrical signal which is
areas. The novel design of the transmitted as an analogue value.
Heat
These detectors use two Product Codes Approval Branded Model
networked thermistors in a bridge 516.053.001.T LPCB Thorn MD901
configuration to provide a fast
response, that depends both on locker rooms, canteens, garages, loading bays etc.
absolute temperature and notes The integral electronics emulate conventional fire
the change of temperature. The rate of rise/fixed detector's response curves and transmit the state
temperature heat detectors can be used in areas to a controller as an analogue representation of
where smoke sensors are unsuitable due to the ambient temperature conditions.
environmental conditions smoke, dust etc,). Such
areas include kitchens,
12
Tyco Marine Services Korea
Optical Smoke
These detectors are capable of Product Codes Approval Branded Model
detecting the visible smoke 516.057.401 Marine Thorn MR601M
produced by materials which
smoulder or burn slowly, i.e. soft signal processing techniques stop unwanted alarms
furnishings, plastic foam etc;. or caused by very small insects. i.e. thrips. Smoke
smoke' produced by overheated but unburnt PVC. entering the sampling chamber scatters the infrared
These detectors are particularly suitable for general light pulses onto a photodiode These pulses
applications and areas where cable overheating are converted to an electrical signal which is
may occur e.g. electrical services areas. The novel compared against a preset alarm level.
design of the asymmetrical sampling chamber and
Heat
These detectors use two Product Codes Approval Branded Model
networked thermistors in a bridge Rate of Rise
configuration to provide a fast 516.052.001.T LPCB Thorn MD601
response, that depends both on Fixed Temperature 60°C
absolute temperature and notes 516.052.011.T LPCB Thorn MD611
the change of temperature. The Fixed Temperature 60°C
rate of rise/fixed temperature heat 515455 UL Grinnell 632H
detectors can be used in areas 516.052.022 UL Thorn 632H
where smoke sensors are The integral electronics emulate conventional fire
unsuitable due to environmental
detector's response curves and transmit the state
conditions (smoke, dust etc,). Such areas include
to a controller as an alarm condition.
kitchens, locker rooms, canteens, garages, loading
bays etc.
13
tyco Fire &
Securit
y
Detector Bases
The Standard Universal detector bases are compatible with both conventional (M600) and analogue (M900) addressable detectors. The bases have no
electronics and even when the detectors are connected to the bases, they can be electrically disconnected and left in a “park” position. This enables wiring
integrity tests to take place without any damage to electronics. When used with addressable detectors, the smart card access key automatically transfers to
the base, thus the address remains with the base even if the detector is changed or replaced. An optional, tool removable locking pin allows the detector to be
fixed in place to prevent tampering.
Heat
14
Tyco Marine Services Korea
15
tyco Fire &
Securit
y
MC900 & 900RBA Functional Relay Base
The 900 Series relay base provides dual relay Technical Specification
contacts for signalling external devices on Operating Temp.: -25 to 70°C
addressable systems. Very low operating current Humidity: Up to 96% RH (non-
even when the relay is energised, enable the relay condensing)
base to be used without any additional power. On Vibration: Exceeds requirements of
addressable systems, the dual contacts operate prEN54-3 Marine & UL268
when the detector is in alarm OR when Power Supply: Loop/Circuit
commanded to do so by the panel. Product Codes
Features 568.001.016
• Dual pole 24V d.c. relay contacts (60VA) MC900 Relay base (BS 5839)
• Status indication LED 568.001.019
• Very low power consumption (<20µA except 900 RBA Relay base (UL -Thorn)
start up) 515591
• Can be used in place of a standard base 900 RBA Relay base (UL - Grinnell)
16
Tyco Marine Services Korea
Bells
6” Red Solenoid Operated Friedland Bell
The bells are the underdome type, with a high 576.500.009.T
resonance pressed alloy-steel gong to ensure a fully enclosed and the gong is red stove
loud clear-tone ring. The operating mechanism is enamelled for long life. The bells are designed for
fully enclosed and the gong is red stove 24V Bell 6” 24V d.c. solenoid operated.‘Fire’ text
enamelled for long life. The bells are designed for with Thorn branding
internal use, but gasket sealed conduit boxes can 577.001.002
be provided for external use. BELL WP BOX Weatherproof gasket box 6” for
use with Solenoid operated bells
Product Codes
576.500.004.A
240V Red bell 6” 240Va.c. solenoid operated.
‘Fire’ text with ADT branding
576.500.004.T
240V Red bell 6” 240Va.c. solenoid operated.
Fire’ text with Thorn branding
576.500.009.A
24V Bell 6” 24V d.c. solenoid operated. ‘Fire’ text
with ADT branding
Motorised Bells
Features 576.501.040.T
• CE marked MBF-8WE Thorn Branded
• Low current 6” bell (ONLY 15MA) 576.501.040.A
• Low cost MBF-8WE ADT Branded
• Extra high 94dBA/m Other branding available on request
• Slim profile (53mm)
• Fully suppressed and polarised
• Quick and easy to install Model MBF-6WE MBF-8WE
Rated Voltage 24V d.c. 24V d.c.
Product Codes Rated Current 15mA 15mA
576.501.039.A Sound output 94dBA 95dBA
MBF-6WE ADT Branded Operating Tem 10 to +50°C
576.501.039.T Colour Red
MBF-6WE Thorn Branded Weight 720g 1420g
17
tyco Fire &
Securit
y
Call Pointers
Conventional CP200 Callpoint
The CP200 is a red indoor callpoint with ‘alert’
resistors and LED indicator. The CP200 is LPCB
approved.
Product Codes
514.001.042.T
CP200 without backbox, English ‘Fire’ marking
and Thorn Security branded lid
514.001.042.Y
CP200 with backbox, English ‘Fire’ marking and
Tyco branded lid
514.001.042.A 514.001.006 514.001.057
CP200 without backbox, English ‘Fire’ marking CP200A complete with surface backbox. Arabic CP200E without backbox, European ‘Fire’ marking
and ADT branded lid English ‘Fire’ marking. Thorn Security branded and glass, unbranded lid
90-110
Standard KAC KR-1 Flush Callpoint (No resistors
fitted)
70-133
Standard KAC KR72-680 Flush Callpoint
(680 Ohms resistance)
18
Tyco Marine Services Korea
514.001.014
CP270 Yellow callpoint ‘Evacuate’ complete with
LED indicator without backbox - LPCB approved.
English ‘Fire evacuate’ marking
19
tyco Fire &
Securit
y
Special Hazards Detectors
S111 and S121 Series Flame Detectors
• BASEEFA approved EEx ia IIC T5 Connections
• Housing protection to IP65 S111 Milspec plug sealed into body
• Integral stainless steel 316 mounting bracket Milspec mating socket with 2m of 4 core PVC
• 2 core interface to conventional fire systems insulated, braid screened PVC sheathed cable
• Built in response indicator to DEF Std 61-12 Pts 4
• High immunity to smoke, dust and grime S121 One 4 way, 2.5 mm heavy duty terminal
Technical Specification block
Material: Impact resistant moulded Product Codes
plastic (light grey) 516.009.006
Dimensions: 160H x 80W x 60D mm S111 Infra-red Flame detector solar blind plug and
(without bracket) socket connection
Weight: 0.6Kg 516.009.008
Gland Entry (S121): 1 x 20mm S121 Infra-red Flame detector solar blind screw
Range: 0.1m2 petrol at 20m terminal connections
The S111 and S121 (and variants thereof) are 0.4m petrol at 40m 516.009.014
single sensor infra-red flame detectors with optical Field of View: 85° min inclusive S121 Infra-red Flame detector solar blind screw
filtering, suitable for use outdoors in a wide range Response Time: 3 secs min, 5-10 secs typical terminal connections (Pyrotronics) FM Approved
of applications. Supply Voltage: 15.5 to 25.5Vd.c. 516.009.007
Specifically designed for use in the demanding Quiescent Current: 100µA max. at 20Vd.c. S112 Infra-red Flame detector non solar blind plug
environments of the onshore petro-chemical Alarm Current: 60 mA max and socket connection
industry, the S111 and S121 detectors incorporate Operating Temp.: -30°C (-40°C with reduced 516.009.015
an abrasion resistant sapphire window in a range) to + 70°C S122 Infra-red flame detector non solar blind
protective housing to meet IP65. Storage Temp.: -40°C to + 80°C screw terminal connections
Features Relative Humidity: 95% (100% intermittent) 516.009.019
• No false alarms from welding, sunlight or high Enclosure to: IP65 S122 Infra-red Flame detector non solar blind
intensity lamps Classification: BASEEFA EEx ia IIC T5 screw terminal connections (Pyrotronics)
• Low maintenance costs Suitable for use in zones 0,1
• Quick response to carbon fires and 2 where group IIC
• Good performance (20m) gasses or lesser hazards
• Completely solar-blind for use outdoors are present in explosive
• High sensitivity with exceptional interference concentrations.
rejection BASEEFA Cert No.: Ex 812333
S131 Flame Detectors
sapphire windows and protection against water Technical Specification
ingress under sustained, high wind driven Material: G.R.P. Anti-static, black
conditions. The S131 Infra-red Flame Detector Dimension: 160H x 160W x 90D mm
uses the same optical and electronic module as (without bracket)
the S111 and S121 detectors. It therefore has
Weight: 2.85 Kg (including bracket)
near identical performance characteristics making
Gland Entry: 2 x 20mm
it completely blind to solar radiation whether
direct, reflected or modulated. Range: 0.1m2 petrol at 20m
Response Time: 3 secs min 0.4m petrol at 40m
5-10 secs typical Field of View: 90° min inclusive
Product Codes
516.009.023
S131 Infra-red Flame detector solar blind
The S131 has been specially packaged in a tough 516.009.028
GRP anti-static housing with abrasion resistant S131 Infra-red Flame detector solar blind
Pyrotronics
S161 Flame Detector
S121 and S131 detectors. It therefore, has Alarm Current: 2-wire, latching.
identical performance characteristics making it 720 ohm in series with
completely blind to solar radiation whether direct, typically 4V switched across
reflected or modulated. In order to meet the supply
demands of arduous environments, such as Alarm Indication: Red LED
chemical plants and off-shore oil and gas Connections: Two 4 way 2.5mm heavy
platforms, the S161 detector has been packaged duty terminal blocks
in a tough G.R.P. anti-static housing, which makes Hazardous Area: BASEEFA Ex e s ib IIC T5.
it mechanically similar to the S131 detector. Suitable for use in zones 1
Two 20mm cable entries and two 4-way terminal and 2 where group IIC
blocks are provided, which eliminate the need for gases or lesser hazards are
a local junction box, reducing installation costs. sometimes present in
When using the existing Ex‘d’ wiring associated explosive concentrations.
with UV detectors, the use of BASEEFA certified BASEEFA Cert. No: EX87Y 3550
The S161 Infra-Red Flame Detector is specifically glands rated Ex‘e’ is mandatory.
designed to replace installed UV units using Product Code
existing Ex d wiring, making replacement highly Technical Specification 516.009.022
cost effective. Supply Voltage: 18.0V to 24.0 V d.c. (polarity S161 Infra-red Flame detector solar blind
The S161 Infra-Red Flame Detector uses the conscious) complete with built in intrinsically safe isolation
same optical and electronic module as the S111, Quiescent Current: 100µ A max. at 20V d.c. area
20
Tyco Marine Services Korea
21
tyco Fire &
Securit
y
Heat Detectors
MD300Ex Range may provide an acceptable, the broad classifications of 'rate-of-rise' and 'static'
though less sensitive,alternative. For general use, the MD300 range offers several versions so that
and particularly where the ambient temperature the optimum response can be chosen for each
may be low, a 'Rate-of-Rise' heat sensor is to be application.
preferred. This type of sensor reacts to
abnormally high rates of change of temperature Product Codes
and provides the fastest response over a wide 516.023.002 (Vol01A-02-D7)
range of ambient temperatures. A fixed MD301Ex Grade 1 Rate of rise heat detector
temperature limit is also incorporated in these 516.023.004 (Vol01A-02-D7)
detectors. MD303Ex Grade 3 Rate of rise heat detector
In many environments, e.g. kitchens and boiler 516.023.006 (Vol01A-02-D7)
rooms, sudden, large changes in temperature are MD305Ex Temperature range 2 heat detector
considered 'normal'. Rate-of-rise detectors are 516.033.002 (Vol01A-03-D6)
If environmental conditions rule out the use of generally not suitable in these cases and fixed MD501Ex Analogue Addressable Heat detector
smoke detectors, then a heat detector of the type temperature [static] types should be used. Within
22
Tyco Marine Services Korea
23
tyco Fire &
Securit
y
Intrinsically Safety Products
The following section relates to a range of intrinsically safe barrier and isolator equipment for use with Tyco Electronic Product Group manufactured fire
detection systems. It essentially encompasses the relevant MTL 5000 and MTL 7000 series barriers plus the associated housing options as an alternative to
existing MTL 700 and MTL 3000 series equipment.
On all issues of intrinsically safe systems design, please refer to Manual 26A for guidance.
Galvanic Barriers
MTL 5000
The MTL 5061 is a two channel interface for use When designing new systems or upgrading
with conventional fire and smoke detectors existing MTL 3000 series systems to MTL 5000
located in hazardous areas. This galvanic isolator series, please use the appropriate MTL “DX”
is CE marked, and replaces the MTL 3043 barrier series enclosure equipment.
option. It is suitable for connecting loads in Zone
0, IIC, T4-6 hazardous areas if suitably certified. Product Codes
The MTL 5021 Isolating sounder driver enables 517.001.244
an intrinsically safe sounder device located in the MTL 5061 2 channel galvanic isolator for
hazardous area, to be controlled from the safe conventional detector zone - used on BASEEFA
area. The MTL 5021 barrier is designed as a CE Approved System 601
marked replacement for the existing MTL 3021 517.001.245
barrier. It has one channel and is suitable for MTL 5021 I.S. Sounder driver
connecting loads in Zone 0, IIC, T4-6 hazardous
area if suitably certified.
MTL 3000
The MTL3000 series interface units offer a S100 series, S231i+ ) automatic fire detectors and
compact and easy-to-use means for the CP220Ex intrinsically safe callpoints. The
communicating safely with conventional fire MTL3043 is not suitable for use with addressable
detectors and output devices in the hazardous fire detectors. For application guidance, refer to
area. The MTL3000 solution provides an the relevant documentation for system 601 and
alternative to the shunt-diode safety barrier where system 602.
isolation is essential or preferred or a high
integrity earth is not readily available. Product Codes
The MTL 3021 enables the intrinsically safe 517.001.204
sounder type IS28 (576.501.013) to be activated SYS.601/602 MTL3043 Galvanic Isolation safety
from the safe area. An absolute maximum of 4 off barrier
I.S28 sounders may be connected to each 517.001.203
MTL3021 unit. SYS.601/602 MTL3021 Galvanic Isolation safety
The MTL 3043 is used primarily with intrinsically barrier
safe conventional type (M300 series, H600 series,
Zener Barriers
MTL 7100
The MTL 7100 Series intrinsically safe shuntdiode during commissioning, maintenance and fault
safety barriers are innovative devices finding, thus avoiding the need for additional
designed to provide exceptionally high packing disconnect terminals.
densities, straightforward installation and Please note that this barrier is a direct alternative
simplified connection, commissioning and for the MTL 728+ barrier. Currently, there is no
maintenance facilities. The MTL 7100 Series direct alternative for the MTL 788+ barrier used
include secondary replaceable fuses. These are with the MINERVA addressable system. So
useful where there is the possibility of faults addressable MINERVA systems must use the
occurring during commissioning, which would existing MTL 788+ barrier and associated housing
otherwise blow the barriers’ internal safety fuses. option.
One secondary replaceable fuse for each barrier Product Code
channel is provided and is lower in value than the 517.001.246
safety related fuse. Fuses are packaged in small MTL 7128+ Zener safety barrier for conventional
mouldings which can be latched in a disconnect detection circuits designed in accordance with
position to break the safe and hazardous areas System 601
MTL 700
The MTL700 series are 1 or 2 channel devices
which pass the electrical signal from fire detectors Product Codes
to the control panel or from the control panel to 517.001.201
the output device. The barriers limit the amount of SYS.601/602 MTL728 Single Channel Zener
energy to a level that cannot ignite explosive Safety Barrier.
atmospheres. The over-voltage protection 517.001.202
provided by a Shunt-Diode Safety Barrier is with SYS.601/602 MTL788 Dual Channel Zener Safety
reference to the safety barrier earth connection. It Barrier.
is therefore imperative that a HIGH INTEGRITY 546.004.005
EARTH is used for this type of barrier. SYS601/602 Intrinsically safe sounder circuit
interface module
24
Tyco Marine Services Korea
CP540Ex IF500Ex
Dimensions(H x W x Dmm) 87 x 87 x 51.5 122 x 120 90
Weight 200g 900g
Material Polycarbonate Polyester
Conventional No No
Addressable Requires IF500Ex Yes
Colour Red Grey
BASEEFA Cert. Simple Apparatus 89C2202
IP Rating IP67 IP67
Note: Variants are available on request
514.001.023 514.001.017
CP540Ex Red callpoint intrinsically safe for use IF500Ex Intrinsically safe addressable interface
with IF500Ex. English ‘Fire’ marking and Thorn module. May be used to interface simple
Security branded lid. Simple apparatus marking apparatus switch callpoint to MINERVA analogue
addressable system. For use on BASEEFA
certified System 602
25
tyco Fire &
Securit
y
T2000 System / MX
MINERVA Expert T2000 Marine Detection Panel
incorporates the ODM800 operator display
module with a 16 x 40-character backlit LCD
display, simple alphanumeric keypad, 5 softkeys
and a fast access key. The OCM800 operator
control module provides all mandatory operator
control keys and LED functions including
Day/Night switching. Two control keys and 2
indication LEDs are provided for vessel specific
The T2000 is a fully Marine approved EN54 functions.
compliant 1 to 4 loop networkable detection Control keys and LEDs are labelled in English
panel. The T2000 supports two Tyco MX DIGITAL according to the default Marine functionality. The
detection loops and can be expanded to four slide in decals can be reversed and alternative
loops supporting up to 1000 addressable text added.
devices. The batteries and any additional zone LED’s or
The T2000 consists of a strong steel Marine operator controls are mounted in a separate
approved enclosure incorporating: housing which can be mounted below the main
. PSB800M 5A 24V DC battery backed power panel or behind the panel. The battery box has a
supply and loop booster to EN54pt4 heavy duty backbox and battery clamp. The
. FIM800 field interface PCB incorporating one chassis plate in the battery box also has space for
or two MX DIGITAL loops up to 2 x IOB800 input/output expansion modules
. CPU800 32 bit processor and memory card (maximum 24 I/O) or 1 x PSM/PSB800.
. Optional network card and additional loop card(s)
The panel has a strong cast aluminium front door, Product Codes
which incorporates a modular user interface that For prices, availability and support contact:
fully complies with EN54 pt2. The user interface Tyco Marine Services Korea
character backlit LCD display, simple The T2000 repeater with Power Supply is
alphanumeric keypad, 5 softkeys and a fast connected to the Panel via the remote bus
access key. The OCM800 operator control (RS485, 1200 m distance). A maximum of x 2
module provides all mandatory operator control repeaters (including one MX REMOTE repeater)
keys and LED functions including Day/Night can be linked to each T2000 panel and can
switching. Two control keys and 2 indication LEDs provide full repeater functions for all panels on
are provided for vessel-specific functions. the system.
Control keys and LEDs are labelled in English The operator control module (OCM800) can
The T2000 full function repeater is an EN54
according to the default Marine functionality. The support up to 80 inputs and outputs in the form of
Marine approved repeater with optional
slide in decals can be reversed and alternative LED annunciators, IOB800 input/output modules,
addressable EN54:Pt.4 power supply. The
text added. XIOM universal I/O modules or XIOM 800 LED
repeater consists of a steel backbox and cast
The back box has a removable chassis plate with mimic module.
aluminium front door which incorporates the
the PSM800M power supply, APM800 Product Codes
ODM800 operator display module with a 16 x 40-
addressable PSU monitor and space for 2 x 7 Ah For prices, availability and support contact:
batteries to provide 72 h backup. Tyco Marine Services Korea
26
Tyco Marine Services Korea
MX Graph / MXNet
MXGraph
fill areas, flood fill locations, zoom areas and generate specific and useful reports
zoom magnifications are all imported from • Available in English, Dutch and Spanish
AutoCad. This configuration tool significantly MXGraph can be connected to up to 99
reduces configuration time, increases the integrity networked MX fire panels using the LPCB
of information and enables simple updates to the approved MXNet. MXGraph will also be available
system in the future. for use with up to 64 MX fire panels networked
Features using the LON based VdS approved FILNET.
• Combined text and graphics display on a MX net will support up to 3 fully operational
single P.C. MXGraph user interfaces on a network plus
• Connected to MXNet, a single system can be additional units operating as graphical mimics.
used to monitor up to 99 MX fire controllers MXGraph consists of a standard personal
• Designed for touch screen operation computer, that is linked onto the MXNet via a TLI-
• Simple operator controls, no Qwerty keypad 800 network interface module. MXGraph is
• High resolution colour SVGA display primarily operated by either mouse or touch
• Windows NT TM multi-tasking operating system screen, with the three monitor options available
• Four level automatic zoom sequence available 17”, 20” or 22”touch screen.
Introduction for each point For an up to date specification of the latest
MXGraph is a fully integrated graphical and text • Overview map maintains a view of wider areas approved PC platform, contact the Fire Product
user interface for use with MINERVA MX, whilst zooming into detail in the graphics Manager.
ZETTLER EXPERT and MINERVA T2000 window Product Codes
networked fire panels. • Procedure window provides additional text 508.020.00 7
Whether the installation uses a single sub-panel and operator instructions for each event Compatibility tested PC for MX & ThornGraph
or up to 99 networked sub-panels, MXGraph • Classification of events helps to maintain a graphics terminal preloaded and configured with
provides a seamless integrated graphical mimic record of activation and the causes default passwords
with full alarm management and panel control • Browse icons placed on maps can be used to 508.020.006
capability. pan across an installation in a logical 22 inch Liyama Touch Pro
MXGraph has been designed with clear displays sequence 636.006.060
and simple controls which can be quickly and • Control icons placed on maps can be used to 17 inch Standard monitor
easily understood by an operator rather than an initiate actions at the MX fire controller, used to 508.020.201
engineer. The system is designed to be used with operate ancillaries such as HVAC Software package A for 1 network node
a touch screen or mouse and does not require • Automatic configuration using the GRAB-IT 508.020.202
the use of a Qwerty keyboard. tool, including Cad drawings, text messages, Software package B for 2-5 network node 5
Using the secure acknowledged transfer of locations, flood fills and zoom areas 508.020.203
events, up to three MXGraph systems can be • Full password protection and multiple operator Software package C for 6 or more network nodes
used to monitor up to 99 MX controllers levels 508.020.204
connected to an MXNet. • Remote control of MX fire controller across the Software package D for additional graphics nodes
MXGraph uses a unique configuration tool GRABIT, network on the same MXNet
(Graphical, AutoCad, Bitmap, Information, • Real time on line event management and MXGraph is functionally similar to Thorngraph.
Transfer) to automatically configure the system. historic information system For full details of upgrade paths contact the Fire
Installation plans, device type and location, flood • User designed search keys can be used to Product Manager.
TLI800
TLO530 TLO530
Fibre Fibre
Interface Interface
Max distance between
nodes is 4000m using
fibre optic cable
27
tyco Fire &
Securit
y
MX VIRTUAL Multi-Sensor Detectors
Construction & Technical Specification
The 800 Series detectors are supplied in an
extremely robust and reliable fully sealed
construction, which has undergone stringent
environmental and Marine type testing. All
electrical contacts are moulded into the plastic to
eliminate any movement.
The detectors are constructed from hardwearing
Fire Resistant FR110 plastic.
The multi-sensor detectors are environmentally
friendly. They use no radioactive parts and can be
returned to the factory for recycling at the end of
their life.
All 800 Series detectors are supplied with integral
dust covers as part of the packaging. Dust covers
are retained throughout installation and removed
at commissioning time.
Unique design of the 801PH optical chamber
provides immunity to thrips and other small
insects without the need for metal gauze.
28
Tyco Marine Services Korea
Product Codes
Branding ADT THORN WORMALD ZETTLER TYCO
801PH 516.800.500.A 516.800.500.T 516.800.500.W 562.000 516.800.500.Y
811PH For prices, availability and support contact Tyco Marine Services Korea
Product Codes
Branding ADT THORN WORMALD ZETTLER TYCO
801CH 516.800.501.A 516.800.501.T 516.800.501.W 562.001 516.800.501.Y
811CH For prices, availability and support contact Tyco Marine Services Korea
29
tyco Fire &
Securit
y
800I Ionisation Smoke Sensors
The 800I ionisation detectors are offered for old Technical Specification
specifications which still call for ionisation smoke Dimensions: 109dia x 43H mm
detectors. The 800CH and 800PH detectors offer Operating Temp.: -20 to +70oC
improved performance, significantly lower false Storage Temp.: -40 to +80oC
alarms and environmental compatibility for smoke Relative Humidity: 95% (non condensing)
detection applications. The 800I nevertheless Standards: prEN54 pt 5
offers state-of-the-art ionisation smoke detection prEN54 pt 7
with self verification, smoke level indication and
threshold compensation for detector condition
monitoring. The 801I is LPCB approved.
Product Codes
Branding ADT THORN WORMALD ZETTLER TYCO
801I 516.800.502.A 516.800.502.T 516.800.502.W 562.002 516.800.502.Y
base allows any or all 800 Series MX detectors to . All the features of MUB
circuit isolation. Implemented on every detector technical publications for design parameters)
the 801IB can ensure that no detector is lost on a . Isolation “upstream” and “downstream
30
Tyco Marine Services Korea
6B - 6” Universal Base
Especially designed for applications using the US Features
style single gang backbox the 6” base provides . Waterproof gland protects the detector from
an attractive styled alternative to the 4” base in water ingress from the rear
most applications. The 6” base is particularly . Remote LED connections
useful for retrofit applications where large holes . Anti-tamper facility
left by previous installations cannot be covered by . Includes blanking pieces for mounting holes
the 4” base.
Product Codes
517.050.606
6B-6” detector base (UL)
The 801SB sounder base operates with all 800 . 3 selectable tones (slow , fast and continuous) 801SB loop power sounder base
Series MX VIRTUAL detectors. A unique design . 3 volume settings (90 , 80 and 70dB effective) Note: For detailed design guidelines on loop
single point sound source is used to provide . single point sound source powering ensure that Technical Publications are
complete audio coverage without obtrusive holes . standard MINERVA frequency consulted.
. complies to prEN54:pt.3
801RB - Functional Relay Base
The 801RB provides dual relay contacts for Features
signalling external devices on MX addressable . Dual pole 24V DC relay contacts (60VA)
systems. A very low operating current even when . Status indication LED
the relay is energised enables the relay base to . Very low power consumption (<20µA except
31
tyco Fire &
Securit
y
MX Ancillaries
Callpoints & Pullstations - CP820 Indoor Callpoint
Technical Specification Product Codes
Meets BS5839 Pt.2 and pr EN54 Pt:11 514.800.503.T
EMC/RFI: Equal or exceeds EN50081- CP820 Indoor Callpoint (English – Thorn Branded)
1 & EN50082-1 514.800.503.A
Operating Temp.: -20 to +70oC CP820 Indoor Callpoint (English – ADT Branded)
Relative Humidity: up to 95% RH noncondensing 514.800.503.Y
Dimensions: 87H x 87W x 51(19mm flush CP820 Indoor Callpoint (English –TYCO Branded)
mount)D mm 552.006
Weight: 200g CP820 Indoor Callpoint (International)
Quiescent Current: 0.25mA 514.800.511.T
The CP820 is an indoor MX addressable manual Thorn KAC Indoor Callpoint (Dutch)
Alarm Current: 2.5mA
callpoint with programmable status LED. The 552.004
Ident. Value: 129
CP820 is designed for LPCB approvals and the Zettler KACindoor Callpoint (Dutch)
CP820M for Marine approvals. The CP820 CP820M Indoor Marine Callpoint
provides high speed communication to the MX
panel of a manual fire alarm.
Detector Ancillaries
800 Series MX Address Flag
the detector base, when the detector is plugged
into the base. On removal of the detector the Product Codes
address flag remains on the ceiling, thus ensuring 516.800.915
that detectors are not accidentally returned to the MXAddress flags (pack of 100)
wrong detector base following service routines. 516.800.931
Most MX detection panels incorporate additional Address flag labels Loop A - White
fail safe software features to ensure that incorrect 516.800.932
detector positioning does not compromise the Address flag labels Loop B - Yellow
system. 516.800.933
Address flags are supplied in packs of 100. Address flag labels Loop C - Purple
Labels are provided on sheets of 250 in four 516.800.934
The 800 Series detectors incorporate a feature, Address flag labels Loop D - Green
colours to enable quick identification between
which automatically transfers the address flag to
different loops.
32
Tyco Marine Services Korea
33
tyco Fire &
Securit
y
Gas Detectors
SafEye®
Optical Open Path measure a gas cloud is a result of the patented
Gas Detectors lamp source technology, and advanced
proprietary mathematical algorithms. These
technologies combine to continuously analyze
the IR or UV spectrum along the instrument’s
path and identify the unique “finger print” of the
target gas.
34
Tyco Marine Services Korea
FLAME
2 METERS
SafEye® 50% LEL Cloud ■ 50 PPM Cloud
HEAT
Operational
SUN Zone
1 METER
20% LEL Cloud ■ 20 PPM Cloud
35
tyco Fire &
Securit
y
Model 200
36
Tyco Marine Services Korea
Power Supply _____________________Standard - 24 VDC (18-32 VDC) under even the most adverse
environmental conditions. Source
Power Consumption ___________________ Detector: 150mA @ 24 VDC (200 mA Peak);
and detector housings are made
Source:100mA @ 24 VDC (220 mA Peak)
from anodized aluminum with a 316
Electric Input Protect ___________________ According to MIL-STD-1275: stainless steel option available. Back
Electromagnetic Compatibility ____________ EMI/RFI protected CE Marked covers are sealed with special orings
Outputs _____________________________ 4-20mA; RS - 485 that prevent intrusion from
Relays ______________________________ dust, salt, and sprays. Internal circuit
boards are protected from vibration,
Alarm ___________________________ SPDT; (NO, NC) 2A@30Vdc (0.5@250Vac)
moisture and corrosion. SafEye
Accessory ________________________SPDT; (NO) 5A@30Vdc or 250Vac
detectors are currently installed and
Fault ____________________________ SPDT; (NC) 5A@30Vdc or 250Vac
functioning in areas such as the
Approvals ____________________________UL Approved Class I Div. 1 Groups C and D and Class North Sea, Alaska, Saudi-Arabia,
II Div. 1 Groups E, F and G and Indonesia.
CENELEC approved SCS No. Ex96D1067: EExd IIB +
H2 T6 per En 50014 & En 50018; SCS No. Ex
98E1119: EExde IIB + H2 T5 per En50014 & En50018 Easy Installation
& E50019 FM - The swivel or tilt mounting
Electrical Connection ___________________Two ¾” – 14NPT conduits. assemblies (constructed of epoxy
coated 316L stainless steel) and the
___________________________________Optional: Two M25 x 1.5 conduits
telescopic alignment kit make the
Dimensions ___________________________5.2" (132mm) x 5.2" (132mm) x max. 11" (280mm)
SafEye’s installation quick and
Weight ______________________________ Alum. Encl.: (Detector) max 8.8 lb (4 kg); (Source) effective. SafEye’s alignment utilizes
max 10.78 lb (4.9 kg) St.Steel Encl.: (Detector) max on-board LEDs to indicate when the
14.3 lb (6.5 kg); (Source) max 16.72 lb (7.6 kg) system is optimally aligned. In
IP Rating ____________________________ IP66 and IP67 addition, SafEye offers the widest
37
tyco Fire &
Securit
y
Life Safety Equipments
Scott Health & Safety has been a world leader since 1945 in the development and manufacturing of self-
contained breathing apparatus (SCBA), airline respirators, emergency escape respirators, air-supplied
equipment, air-purifying devices, gas/vapor monitoring instruments, communications equipment, and the
all-new thermal camera.
Others
Fire Axe
Essential to eliminate obstacles at firefighting site. Insulated handle with rubber
coating insures non-slippery and safety. Designed to multi-use and easy to
carry along.
- Length : 570㎜
- Weight : 1.5㎏
38
Tyco Marine Services Korea
Supply hose
Sabre have been manufacturing breathing apparatus
for over 25 years – one of their original concepts being
Elastomeric neckseal
the ELSA constant flow escape breathing apparatus.
The new ELSA is the third generation version of
this popular product, originally designed in 1982.
Activating strap Contents indicator
This latest version reflects the original concept due to
its simplicity and robustness combined with performance
to the latest European Standard EN1146.
The ELSA reflects Sabre’s stated philosophy of
Quick-release pin Whistle
producing products which customers wear by choice,
Combined cylinder valve and pressure reducer with charging connector
not just necessity.
ELSA FEATURES INSTANT ACTION with existing hood designs. alloy cylinder whereas the
The Sabre ELSA comprises The constant flow air supply The hood can be easily 15 minute apparatus uses a
a compressed air cylinder is automatically activated flat-packed for stowage without 3.0 litre, 200 bar alloy steel
with combined cylinder and upon opening the bag. creasing the visor whilst cylinder.
pressure reducing valve, A quick release pin is allowing rapid removal from Each cylinder provides
supply hose to air hood and fitted to the pressure the bag for easy donning. 400 or 600 litres free air
stowage bag. reducing valve and attached The hood is fabricated from capacity respectively giving
The new, unique hood to the bag via a strap. The PVC coated materials with a duration in excess of 10 or
design provides new levels action of opening the bag an ozone resistant elastomeric 15 minutes at a nominal airflow
of comfort and peripheral pulls the strap – thus neckseal. of 38 litres/minute.
vision. The new valve design releasing the pin. An inner mask prevents Cylinders are are manufactured
incorporates some of the visor misting and minimses to EC specification.
PNEUMATIC SYSTEM
best design features from CO2 dead-space. Other materials/specifications
The combined cylinder and The hood is available in available on request.
the Sabre range of the
pressure reducing valve is two versions; a standard
breathing apparatus for new WARNING WHISTLE
fitted to the cylinder and type with single PVC coating
levels of performance and
features a spring and piston The ELSA features a duration
reliability. and an E-Z clean doublecoated
mechanism with fixed whistle that is activated
The apparatus is available version.
orifice outlet. The valve when the air is depleted,
in either 10 or 15 minute CYLINDERS
incorporates a pressure indicating that the CO2 level
durations and is CE marked
indicator and warning 10 minute apparatus utilises within the hood exceeds the
to EN1146.
whistle which sounds when a 2.0 litre, 200 bar aluminium performance specification.
the designated duration is
reached. A pressure relief
valve protects the system
from over pressurisation.
The valve features a G5/8”F
standard charging connector
outlet to EN144-2.
AIR HOODS
The air hood utilises a
unique cuboid design for
optimum comfort and
visibility.
The three sided flat visor
provides excellent peripheral
vision with the shape helping
to alleviate the feelings
of restriction asssociated
39