F3SJ Series
Three versions available to meet your exact safety needs.
All versions conform to the latest PLe/Safety Category 4 and SIL3 requirements.
ADVANCED type supports finger protection, and complex blanking and muting functions
BASIC type
F3SJ-B
ADVANCED type
F3SJ-A
[Applicable Standards]
EN ISO 13849-1: PLe/Safety Category 4
IEC 61496-1,-2: Type 4
IEC 61508-1 to 3: SIL3
Authenticated under major safety
standards including European standards.
Series
Connection
Warning
Zone
Global
Support
Series Simple
Mounting Time Connection muting
I only need
simple
functions
mounting time
Existing E type
mounting time models
Machine safety first, narrowed down to the simplest 1/2 the mounting time
functions: Fixed response time makes calculation of the safety distance
Upon detection of personnel, the machine stops. is easier.
Simple yet very optimal. Reduced wiring, quick mount brackets and easy-to-view
alignment beams all add up to cost savings.
Additionally, with one fixed response time, it is know easier
to calculate the safety distance.
5
Global Easy-to-View
Support Diagnostics
Global
Support
Easy-to-View
Diagnostics
Series Simple
Connection muting
Up to three sets-connected in series Instant visibility of process trouble Functions inherited from the EASY
It is possible to connect up to three during muting type
sets of safety light curtains in series. The BASIC type includes a muting Simple functions such as universal
These sensors can be placed in a function which temporarily disables power voltage specification, easy-
U-shaped or L-shaped pattern with a the safety light curtain when a to-view diagnostics, a fixed
single power line, thus requiring less workpiece passes through. In the response time have been inherited
wiring. event of any trouble occurring, the from the EASY type, As a result,
error can be instantly recognized
expect reduced work-hours at each
from the pattern of the LED
indicators, allowing for a fast stage of use, from design and
solution. installation to operation.
8
PC Setting Finger
Tool Protection
Tool for setting parameters and checking Detection capability supports finger-
the system status protection
With the ADVANCED type (F3SJ-A) “SD Even if the distance from the hazard is
Manager”, all parameters can be set and short, we have prepared a lineup that
the system status can be checked with a includes safety light curtains with a
personal computer. Complex settings are detection capability of 14 mm.
now simple to configure
9
Versatile muting function possible The blanking function disables Setting up a warning zone to prevent
specific beams of the Safety Light unnecessary stoppage
Curtain
Equipped with partial muting that If a part of the mechanical Under normal use, if an intrusion
disables only the beams where a equipment is within the detection occurs in the safety zone, the
workpiece passes through, and zone of the Safety Light Curtain, the machine will stop immediately.
position detection muting that relevant beams can be disabled. However, use of a warning zone
disables the beams while detecting This is possible not only with non- will only notify the operator that
the position of a machine or robot. moving parts but also with moving an intrusion has occurred. This can
parts. be used to prevent carelessness
resulting in machine stoppage on
the part of the operator.
Simple Warning
Blanking
muting Zone
Simple Warning
Blanking
muting Zone
Position detection muting Floating blanking A single sensor zone can also be
divided
10 Providing ease-of-use and ease-of-mounting through ingenuity
k!
ic
Cl
k!
ic
Cl
Set the main sensor body Fix the circular fixtures to Slide the lower bracket
into the quick mounting the surface of the aluminum up towards the lower
bracket. Use the clamps to frame and set the upper circular fixture and tightly
tightly clamp the upper body bracket onto the upper clamp the lower body of
of the sensor while lightly circular fixture. the sensor. Once done,
clasping the lower body. mounting is concluded.
TOP
(Top-beam-state indicator)
Save
60%
of installation
time.
Without With
F39-PTJ F39-PTJ
(Conditions: The time was measured from temporary
attachment to the pole until the light beam is detected with
an mounting distance of 3 m and no tilt to mounting pole.)
Easy-to-understand diagnostics
Light curtain status can be immediately determined as the LED will light to indicate the status or
possible error.
Receiver Receiver
When the workpiece speed is not appropriate When the workpiece is stopped
When the input sensor is installed incorrectly When the workpiece speed is too slow
12 Providing multiple functions to cope with the various safety requirements
NEW "Simple wiring connector" used to reduce wiring work by more than 50%*
The connector can be
used to easily connect
between an emitter and
a receiver, reducing the
required wiring time by Wiring time
more than 50%.
Less wiring also reduces
reduced by
the width of the terminal more than
block, saving valuable 50%*!
space in the control panel.
Note: The simple wiring connector
can be used for F3SJ-A/B in
auto reset mode only, not for
F3SJ-E.
*Comparison with existing OMRON
products.
Reduced wiring and space
F3SJ-A
To a USB terminal
F39-JD@A
Single-end
Connector Cable
or Branch Connector
F39-JD@B Connection cable
Double-end
All parameters can be set and the system status
Connector Cable
can be checked with a personal computer. In F39-GWUM
addition to making it easy to monitor the beam "SD Manager"
alignment, the ambient incident light intensity can PC Setting
be displayed in bar graph form for an easy check Support Software
of the system status.
The "SD Manager" PC Setting Support Software helps reduce the time required for installing and troubleshooting the Safety Light Curtain.
Beam alignment is easier. The ambient incident light The error log can be displayed.
intensity can be checked.
The incident light level can be The incident light level when the light The cause of the errors and
displayed in a bar graph for each emission of the Safety Light Curtain is countermeasures are
beam. stopped is displayed in a bar graph. both displayed.
13
function, purchase the Muting Key Cap (for The Safety Light Curtain can be
disabled when an AGV carrying a
F3SJ-B: F39-CN10 and for F3SJ-A: F39-CN6) workpiece passes through.
(sold separately). The muting function is enabled
simply by replacing the Unit's cap with this Key
Cap. In addition, a muting sensor that determines
the muting timing, as well as a muting lamp that
notices the muting status to other operators,
should be connected to the F3SJ.
START YES
ENVIRONMENT RESISTANT
F3SJ-B-02TS
Long distance detection
• "9 m or more" required
• Robust body required
The “ADVANCED type” is
recommended for those
who place emphasis on
• Shortest safety distance high functionality.
• Detection of fingers YES
F3SJ-A
NO
• Series-connection
• Various muting functions
• Various blanking functions
Detection of • PC settings
body YES • Capability: 14, 20, 25, 30, 55 m
F3SR
• Rugged and robust
• Splash-proof • IP67
• Detection of hand & arm YES • Long distance 20 m
• Capability: 30 mm
NO
MS4800
• Rugged and robust
• Long distance 20 m
• Various muting functions
• Various blanking functions
• Capability: 14, 20, 30, 40 mm
15
20 mm Protective bar
Operating range
0.2 to 7 m
From 185 (8 beams)
to 1,105 (54 beams)
Protective height • Compatible bracket
185 to 1,105 mm
See P16 for details.
20 mm Laser pointer
* The protective height of the ENVIRONMENT RESISTANT type is 225 to 1,985 mm.
Control unit
(Cannot be used as a
Detection capability Included Connector muting system in the
controller connection)
14 mm dia. or more • Standard bracket
Laser pointer
Dedicated external
Beam gap indicator set
9 mm or more Spatter protection cover
Setting tool
Operating range
Sold separately Protective bar
0.2 to 9 m Environment-resistant
From 245 (26 beams) • Side flat bracket case
• Free location
to 1,271 (140 beams) Protective height bracket
extension cables
• Space-saving
mounting bracket
Simple wiring connector NEW
245 to 1,631 mm
mm See P60 for details.
* When the minimum object resolution is 14 mm and the beam gap is 9 mm.
http://www.ia.omron.com/
To search for F3SR, enter the following:
F3SR
http://www.ia.omron.com/
To search for MS4800, enter the following:
MS4800
Safety Light Curtain
F3SJ-E
EASY type reduces implementation costs
with 1/2 the mounting time.
• In pursuit of simple functions: Upon detection of personnel, Related Dimensions : Page 54 to 60
information Function List : Page 97 to 97
the machine stops. Safety Precautions : Page 99
Precautions on Safety : Page 100 to 104
• Can be used for simple hand intrusion detection.
• Implementation costs can be significantly reduced.
Ordering Information
Main Units
Safety Light Curtain
Detection Protective height Model
Application Beam gap Operating range
capability (mm) PNP output NPN output
F3SJ-E@@@@P25
Hand protection Dia. 25 mm 20 mm 0.2 to 7 m 185 to 1,105 F3SJ-E@@@@N25
*1
16
F3SJ-E
Laser Pointer
Appearance Output Model
Spatter Protection Cover (2 cables per set, common for emitter/receiver) (10% Operating Range Attenuation)
Appearance Model
F39-HB@@@@ *
* The same 4-digit numbers as the protective heights (@@@@ in the light curtain model names) are substituted by in the model names.
Protective Bar
Appearance Model Remarks
• 2 Light Curtain brackets
• 4 mounting brackets
• 0 to 4 intermediate brackets for backside mounting
F39-PB@@@@ *1
(quantity required for the sensing width)
• 0 to 4 intermediate brackets for mounting to the sides
(quantity required for the sensing width)
• 1 Light Curtain bracket
• 2 mounting brackets
• 0 to 2 intermediate brackets for backside mounting
F39-PB@@@@-S *1 *2
(quantity required for the sensing width)
• 0 to 2 intermediate brackets for mounting to the sides
(quantity required for the sensing width)
Note: The following are not provided with the Protective Bars.
• Safety Light Curtain
• Safety Light Curtain Top/Bottom Brackets
• Wall Mounting Screw Unit
*1. The same four digits indicating protective height that are used in the Sensor model number (@@@@) are used in the part of the Protector
model number.
*2. Purchase the F39-PB@@@@ (which contains two sets of brackets) to use Protective Bars for both the Emitter and Receiver.
17
F3SJ-E
2 for an emitter,
Top/bottom bracket F39-LJB1 Top/bottom bracket for F3SJ-E/B 2 for a receiver,
total of 4 per set
2 for an emitter,
Bracket to closely contact the back
Contact mount bracket F39-LJB5 2 for a receiver,
side of the Sensor.
total of 4 per set
Note: All the sensor mounting brackets for F3SJ-E are sold separately.
*1. Combining F39-LJB2 and F39-LJB3-M6K makes F39-LJB3-M6.
*2. Combining F39-LJB2 and F39-LJB3-M8K makes F39-LJB3-M8.
18
F3SJ-E
Specifications (For details, refer to the instruction manual or User's manual.)
Main Units
F3SJ-E@@@@P25/N25
PNP output F3SJ-E@@@@P25
Model
NPN output F3SJ-E@@@@N25
Sensor type Type 4 safety light curtain
Setting tool connection *1 Parameter settings: Not available
Safety category Safety purpose of category 4, 3, 2, 1, or B
Detection capability Opaque objects 25 mm in diameter
Beam gap (P) 20 mm
Number of beams (n) 8 to 54
Protective height (PH) 185 to 1,105 mm
Lens diameter Diameter 5 mm
Operating range *2 0.2 to 7 m
Response time ON to OFF 15 ms max.
(under stable light
incident condition) OFF to ON 70 ms max.
Startup waiting time 2 s max.
Power supply voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
PNP output Emitter : Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams: 63 mA max.
Consumption Receiver : Up to 22 beams: 42 mA max., 26 to 42 beams: 47 mA max., 46 to 54 beams: 51 mA max.
current
(no load) NPN output Emitter : Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams: 63 mA max.
Receiver : Up to 22 beams: 40 mA max., 26 to 42 beams: 45 mA max., 46 to 54 beams: 48 mA max.
Light source (emitted wavelength) Infrared LED (870 nm)
Effective aperture angle (EAA) Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the detection distance is 3 m or over
Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to
PNP output
Safety outputs cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
(OSSD) Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to
NPN output
cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
Output operation mode Safety output: On when receiving light
PNP output ON voltage: Vs-3 V to Vs OFF voltage: 0 V to 1/2 Vs or open *5
Input voltage
NPN output ON voltage: 0 V to 3 V OFF voltage: 1/2 Vs to Vs or open *5
Mutual interference
Mutual interference prevention algorithm prevents interference in up to 3 sets.
prevention function
• Self test (at power-ON and at power distribution)
Test function • External test (emission stop function by test input)
Protection circuit Output short-circuit protection, and power supply reverse polarity protection
Ambient temperature Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C
Ambient humidity Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH
Operating ambient light intensity Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC 50/60 Hz, 1 min
Degree of protection IP65 (IEC 60529)
Vibration resistance Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
Shock resistance Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions
Pollution degree Pollution degree 3 (IEC 60664-1)
Connection method: Pull-out type, cable length 3 m
Number of wires: Emitter: 5 wires, receiver: 6 wires
Power cable Cable diameter: Dia. 6 mm
Allowable bending radius: R5 mm
Extension cable 30 m max. *6
Case: Aluminum
Cap: ABS resin, PBT
Material
Optical cover: PMMA resin (acrylic)
Cable: Oil resistant PVC
Weight (packed state) Weight (g) = (protective height) x 2.6 + 800
Accessories Instruction Manual, User's Manual (CD-ROM) *7
IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices)
Applicable standards IEC 61508-1 to -3, EN 61508-1 to -3 SIL3
ISO 13849-1: 2006, EN ISO 13849-1: 2008 (PLe/Safety Category 4)
UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety output at 4 Hz or less, the usable load
inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. To extend a cable of the F3SJ-E, refer to the User's Manual (SCHG-733/732).
*7. Mounting brackets and test rod are sold separately.
19
F3SJ-E
Indicator
Emitter
Name of indicator Label ON Blinking
Turns ON when the top beam is receiving
Top-beam-state indicator TOP ---
light.
Turns ON when incidence level is more than Blinks when the safety output is turned OFF
Stable-state indicator STB
170% of the output ON threshold. due to disturbance light or vibration.
ON Green: Turns ON when safety output is ON. Red: Blinks when the F3SJ-E enters a lockout
ON/OFF-state indicator
OFF Red: Turns OFF when safety output is OFF. due to a safety output error.
Turns ON when the F3SJ-E enters a lockout Blinks when the F3SJ-E enters a lockout on
Lockout indicator LOCKOUT
on the receiver. the emitter.
Blinks when the F3SJ-E enters a lockout due
Power indicator POWER Turns ON while the power of the emitter is ON.
to power voltage/noise.
Test indicator TEST --- Blinks when external test is being performed.
Turns ON when the bottom beam is receiving
Bottom-beam-state indicator BTM ---
light.
Receiver
Name of indicator Label ON Blinking
Turns ON when the top beam is receiving
Top-beam-state indicator TOP ---
light.
Turns ON when incidence level is more than Blinks when the safety output is turned OFF
Stable-state indicator STB
170% of the output ON threshold. due to disturbance light or vibration.
ON Green: Turns ON when safety output is ON. Red: Blinks when the F3SJ-E enters a lockout
ON/OFF-state indicator
OFF Red: Turns OFF when safety output is OFF. due to a safety output error.
Turns ON when the F3SJ-E enters a lockout Blinks when the F3SJ-E enters a lockout on
Lockout indicator LOCKOUT
on the emitter. the receiver.
Blinks when the F3SJ-E enters lockout due to
Turns ON when communication between
Communication indicator COM a communication error between receiver and
emitter and receiver is established.
emitter.
Blinks when the F3SJ-E enters lockout due to
Configuration indicator CFG --- a model type error between receiver and
emitter.
Blinks when the F3SJ-E enters a lockout due
Internal error indicator INTERNAL ---
to an internal error.
Turns ON when the bottom beam is receiving
Bottom-beam-state indicator BTM ---
light.
Accessories
Laser Pointer
Item Model F39-PTJ
Applicable sensor F3SJ Series
Power supply voltage 4.65 or 4.5 VDC
Battery Three button batteries (SR44 or LR44)
Battery life * SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation
Light source Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2, EN/IEC class 2, FDA class II)
Spot diameter (typical value) 6.5 mm at 10 m
Ambient temperature Operating: 0 to 40°C Storage: -15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Material Laser module case: aluminum Mounting bracket: aluminum and stainless
Weight Approx. 220 g (packed)
Accessories Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3), instruction manual
* Battery life varies depending on a battery used.
20
F3SJ-E
Connections
Basic Wiring Diagram
Minimum wiring required to check the operation of the F3SJ-E [PNP Output]
Receiver
Emitter
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Open
Open
+24 VDC
Power Note: This circuit diagram is used for operation check.
supply
0V For an actual circuit example, refer to page 23.
Minimum wiring required to check the operation of the F3SJ-E [NPN Output]
Receiver
Emitter
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Open
Open
+24 VDC
Power Note: This circuit diagram is used for operation check.
supply
0V For an actual circuit example, refer to page 23.
21
F3SJ-E
Input/Output Circuit Diagram
[PNP Output]
Entire Circuit Diagram Input circuit diagram by function
0V
Blue
Gray Pink
Communication line (+) Communication line (-)
Gray Pink
Brown
Load
Receiver
Main Circuit 1 Load
Indicator
Blue 0V
[NPN Output]
Entire Circuit Diagram Input circuit diagram by function
<Input Circuit (Test Input)>
Indication
Brown +24 VDC
+24 VDC
0V
Blue
Gray Pink
Communication line (+) Communication line (-)
Gray Pink
Brown
Load
Receiver
Main Circuit 2 White Safety output 2
Load
Indication
Blue 0V
22
F3SJ-E
Connection Circuit Examples
Wiring for single F3SJ-E application [PNP Output]
PL/safety category Model Stop category Reset
Safety Light Curtain F3SJ-E@@@@P25
PLe/4 equivalent 0 Manual
Safety Relay G7SA
Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming
the usage conditions.
z Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed.
Receiver
Emitter
+24 V
Feedback loop
KM2
(Gray) Communication line (+) KM1
K1 K1
(Pink)
Communication line (−) S2 KM2
Safety output 1 (Black)
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
K2 K2
K1 K3 K3
M
K3
K1 K3 K2 K3 K2 KM1 KM2
Unblocked
S1 Blocked
K1 K2 K3 Reset switch
(S2)
+24 VDC External test switch /
Power lockout reset switch (S1)
supply
0V Safety output
K3 N.C. contact
S1 : External test/lockout reset switch (connect to 0 V if a switch is not required) K3 N.O. contact
S2 : Reset switch
K1, K2, K3 : Safety relay with force-guided contact (G7SA) K1,K2 N.C. contact
KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor
M : 3-phase motor K1,K2 N.O. contact
23
F3SJ-E
z Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed.
+24 V
Receiver
Emitter
K3
+24 V +24 V
KM1
(White)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
(Black)
Safety output 2
Test input (Black)
Safety output 1
K2 K2
M
K1 K3 K3
K1 K3 K2 K3
K3
K2
S1
K1 K2
+24 VDC
Power Unblocked
supply Blocked
0V
0V Reset switch
(S2)
S1 : External test/lockout reset switch (connect to 24 V if a switch is not required)
S2 : Reset switch External test/lockout reset switch
(S1)
K1, K2, K3 : Safety relay with force-guided contact (G7SA)
KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor Safety output
M : 3-phase motor
K3 N.C. contact
K3 N.O. contact
24
F3SJ-E
z Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is turned OFF when the emergency stop switch is pressed.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed while the emer-
gency stop switch is released.
- G9SP settings S1 : Emergency stop switch (force-opening contact) (A165E, A22E)
Receiver
Unblocked
(Gray) Communication line (+) Blocked
(Pink) External test/lockout reset switch
Communication line (−)
(S3)
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Reset switch
Test input (Black)
(S2)
Safety output
+24 VDC
Power
supply
0V
V1 Si0 Si1 Si2 Si3 Si4 Si5 Si6 Si7 V2 So0 So1
G1 T0 T1 T2 T3 G2 G2 G2 KM1
Feedback loop
25
F3SJ-E
z Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is turned OFF when the emergency stop switch is pressed.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed while the emer-
gency stop switch is released.
- G9SA-301 settings Wiring for auto reset mode
- Manual reset mode
Receiver
Emitter
Feedback loop
- Using feedback loop
- Using emergency stop switch
KM1
KM2
T31 T32
(Gray) KM1
Communication line (+) A B
KM2
Test input (Black)
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
(S1)
KM2
Interlock reset switch
A1 A2 T11 T12 T31 T32 13 23 33 41 (S2)
3 Emergency stop switch
1 4
(S3)
K2 K1
a K1 1 Safety output
K2 2
3
4 K1,K2 N.O. contact
K1 a Control 2 JP 5
b Circuit 5 6
b K2
KM1,KM2 N.O. contact
6
K1,K2 N.C. contact
PE T21 T23 T22 A B 14 24 34 42
26
F3SJ-E
z Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is turned OFF when the emergency stop switch is pressed.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed while the emer-
gency stop switch is released.
Receiver
Emitter
KM1
Communication KM2
line (+) (Grey)
Safety output 2 (White)
Safety output 1 (Black)
+24V (Brown)
+24V (Brown)
0V (Blue)
0V (Blue)
Test input (Black)
Communication
line (-) (Pink)
M
S1
KM2
Unblocked
A1 A2 T11 T12 T31 T32 13 23 33 41 Blocked
3 External test/lockout reset switch
6 4 (S1)
Note: 1. As the G9SP Safety Controller is a PNP output type, it cannot be connected to the F3SJ-E@@@@N25. Also, a Safety Controller with PNP
output cannot be connected to the F3SJ-E@@@@N25.
2. The G9SA-301-P is a safety relay unit only for NPN output.
27
Safety Light Curtain
F3SJ-B
Basic Type with a combination of
performance and functionality
• Up to three sets of series-connected sensors. Related Dimensions : Page 54 to 60
information Function List : Page 97 to 97
• The muting function is enabled simply with Muting Key Cap. Safety Precautions : Page 99
Precautions on Safety : Page 100 to 104
• Comes standard with interlock and auxiliary output functions.
Ordering Information
Main Units
Safety Light Curtain
Detection Protective height Model
Application Beam gap Operating range
capability (mm) PNP output NPN output
F3SJ-B@@@@P25
Hand protection Dia. 25 mm 20 mm 0.2 to 7 m 185 to 2,065 F3SJ-B@@@@N25
*1
F3SJ-B@@@@P25-01TS
Hand protection Dia. 25 mm 20 mm 0.2 to 7 m 185 to 2,065 ---
*2
Environmental F3SJ-B@@@@P25-02TS
Dia. 25 mm 20 mm 0.2 to 6 m 225 to 1,985 ---
resistance *2
*1. For S-mark compatible model, the suffix "-S" is added to the model name. (except for models with the suffix "-01TS" or "-02TS".)
(Example) F3SJ-E0185P25-S
*2. The F3SJ-B series with the suffix "-01TS" or "02TS" have different functions. Refer to page 35 for details.
28
F3SJ-B
Double-end Connector Cable (2 cables per set, for emitter and receiver)
Control unit for connection with F3SP-B1P, to extend the length under series connection *
Appearance Cable length Specifications Model
0.5 m F39-JDR5B
1m F39-JD1B
3m F39-JD3B
5m F39-JD5B
M12 connector (8-pin)
7m F39-JD7B
10 m F39-JD10B
15 m F39-JD15B
20 m F39-JD20B
* To extend the cable length under series connection, use F39-JBR2W and F39-JD@B in combination. Also, the cable length 10 to 20m cannot be used.
Series connection
cable for 0.2 m F39-JBR2W *1 For series connection *2
extension
29
F3SJ-B
Single-end
Double-end Connector Cable
Connector Cable F39-JD@A-D(Black)
F39-JD@B-L(Gray)
Cable for simple wiring * (2 cables per set, for emitter and receiver)
Appearance Cable length Model Application Remarks
Emitter: 3m Double-end Connector Cable: F39-JD3B-L
F39-JD0303BA
Receiver: 3m Single-end Connector Cable: F39-JD3A-D
Emitter: 3m Double-end Connector Cable: F39-JD3B-L
F39-JD0307BA
Receiver: 7m Single-end Connector Cable: F39-JD7A-D
Emitter: 3m Double-end Connector Cable: F39-JD3B-L
F39-JD0310BA
Receiver: 10m Single-end Connector Cable: F39-JD10A-D
Emitter: 5m Double-end Connector Cable: F39-JD5B-L
F39-JD0503BA
Receiver: 3m Single-end Connector Cable: F39-JD3A-D
Emitter: 5m Double-end Connector Cable: F39-JD5B-L
F39-JD0507BA To reduce wiring
Receiver: 7m Single-end Connector Cable: F39-JD7A-D
Emitter: 5m Double-end Connector Cable: F39-JD5B-L
F39-JD0510BA
Receiver: 10m Single-end Connector Cable: F39-JD10A-D
Emitter: 10m Double-end Connector Cable: F39-JD10B-L
F39-JD1003BA
Receiver: 3m Single-end Connector Cable: F39-JD3A-D
Emitter: 10m Double-end Connector Cable: F39-JD10B-L
F39-JD1007BA
Receiver: 7m Single-end Connector Cable: F39-JD7A-D
Emitter: 10m Double-end Connector Cable: F39-JD10B-L
F39-JD1010BA
Receiver: 10m Single-end Connector Cable: F39-JD10A-D
Note: Cables for the emitter and receiver with other cable lengths than those listed above can also be used in combination. Please contact your
OMRON sales representative for details.
* The cable for the emitter is a double-end connector cable, and the cable for the receiver is a single-end connector cable.
30
F3SJ-B
Wire-saving Devices
Type Appearance Specifications Model Remarks
Model with PNP Muting
F39-TC5P01
Sensor Output
Model with PNP Significantly reduces amount of wiring between
Connector
Override Input
F39-TC5P02 Safety Light Curtains and Muting Sensors.
Terminal Box/
IP67 model for mounting at Sensor installation
Muting Terminals Model with NPN Muting
F39-TC5N01 site.
*2 Sensor Output For details, refer to the OMRON's website.
Model with NPN
F39-TC5N02
Override Input
Laser Pointer
Appearance Output Model
Spatter Protection Cover (2 cables per set, common for emitter/receiver) (10% Operating Range Attenuation)
Appearance Model
F39-HB@@@@ *1 *2
*1. The same 4-digit numbers as the protective heights (@@@@ in the light curtain model names) are substituted by in the model names.
*2. It cannot be mounted to the models with the suffix "-02TS".
Protective Bar
Appearance Model Remarks
• 2 Light Curtain brackets
• 4 mounting brackets
• 0 to 4 intermediate brackets for backside mounting
F39-PB@@@@ *1
(quantity required for the sensing width)
• 0 to 4 intermediate brackets for mounting to the sides
(quantity required for the sensing width)
• 1 Light Curtain bracket
• 2 mounting brackets
• 0 to 2 intermediate brackets for backside mounting
F39-PB@@@@-S *1 *2
(quantity required for the sensing width)
• 0 to 2 intermediate brackets for mounting to the sides
(quantity required for the sensing width)
Note: The following are not provided with the Protective Bars.
•Safety Light Curtain
•Safety Light Curtain Top/Bottom Brackets
•Wall Mounting Screw Unit
*1. The same four digits indicating protective height that are used in the Sensor model number (@@@@) are used in the part of the Protector
model number.
*2. Purchase the F39-PB@@@@ (which contains two sets of brackets) to use Protective Bars for both the Emitter and Receiver.
31
F3SJ-B
2 for an emitter,
Top/bottom bracket F39-LJB1 Top/bottom bracket for F3SJ-E/B 2 for a receiver,
total of 4 per set
2 for an emitter,
Bracket to closely contact the back
Contact mount bracket F39-LJB5 2 for a receiver,
side of the Sensor.
total of 4 per set
32
F3SJ-B
Specifications (For details, refer to the instruction manual or User's manual.)
Main Units
F3SJ-B@@@@P25/N25
PNP output F3SJ-B@@@@P25
Model
NPN output F3SJ-B@@@@N25
Sensor type Type 4 safety light curtain
Setting tool connection *1 Parameter settings: Not available
Safety category Safety purpose of category 4, 3, 2, 1, or B
Detection capability Opaque objects 25mm in diameter
Beam gap (P) 20 mm
Number of beams (n) 8 to 102
Protective height (PH) 185 to 2,065 mm
Lens diameter Diameter 5 mm
Operating range *2 0.2 to 7 m
Response time ON to OFF 15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets)
(under stable light
incident condition) OFF to ON 70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets)
Startup waiting time 2 s max.
Power supply voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Emitter : Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75 mA max.,
66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max.
PNP output
Receiver : Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA max., 46 to 62 beams: 56 mA max.,
Consumption 66 to 82 beams: 61 mA max., 86 to 102 beams: 67 mA max.
current
(no load) Emitter : Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75 mA max.,
66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max.
NPN output
Receiver : Up to 22 beams: 47 mA max., 26 to 42 beams: 52 mA max., 46 to 62 beams: 58 mA max.,
66 to 82 beams: 63 mA max., 86 to 102 beams: 69 mA max.
Light source (emitted wavelength) Infrared LED (870 nm)
Effective aperture angle (EAA) Based on IEC 61496-2.Within +/-2.5° for both emitter and receiver when the detection distance is 3 m or over
Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to
PNP output
Safety outputs cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
(OSSD) Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to
NPN output
cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
One PNP transistor outputs, load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to
PNP output
Auxiliary cable extension), leak current 1 mA max.
output 1 One NPN transistor outputs, load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to
NPN output
cable extension), leak current 1 mA max.
Safety output: On when receiving light
Auxiliary output:
Output operation mode
- Reverse output of safety output for a basic system
- ON when muting/override for a muting system
PNP output ON voltage: Vs-3 V to Vs OFF voltage: 0 V to 1/2 Vs or open *5
Input voltage
NPN output ON voltage: 0 V to 3 V OFF voltage: 1/2 Vs to Vs or open *5
Mutual interference
Mutual interference prevention algorithm prevents interference in up to 3 sets.
prevention function
Time division emission by series connection
• Number of connections: up to 3 sets (between F3SJ-Bs only)Other models cannot be connected.
Series connection
• Total number of beams: up to 192 beams
• Maximum cable length for 2 sets: no longer than 7 m
Test function • Self test (at power-ON and at power distribution)
• External test (emission stop function by test input)
• Interlock (basic system)
• External device monitoring (basic system)
Safety-related functions • Muting (muting system)
• Override (muting system)
Connection type Connector method (M12, 8-pin)
Protection circuit Output short-circuit protection, and power supply reverse polarity protection
Ambient temperature Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C
Ambient humidity Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH
Operating ambient light intensity Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC 50/60 Hz, 1 min
Degree of protection IP65 (IEC 60529)
Vibration resistance Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
Shock resistance Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions
Pollution degree Pollution degree 3 (IEC 60664-1)
33
F3SJ-B
Connection method: Prewired connector cable, cable length 0.3 m, connector type (M12, 8-pin), connector: IP67
rated (when mated)
Power cable Number of wires: 8 wires
Cable diameter: Dia. 6 mm
Allowable bending radius: R5 mm
Extension cable 30 m max.
Case: Aluminum
Cap: ABS resin, PBT
Material
Optical cover: PMMA resin (acrylic)
Cable: Oil resistant PVC
Weight (packed state) Weight (g) = (protective height) x 2.7 + 500
Accessories Instruction Manual, User's Manual (CD-ROM) *6
IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices)
Applicable standards IEC 61508-1 to -3, EN 61508-1 to -3 SIL3
ISO 13849-1: 2006, EN ISO 13849-1: 2008 (PLe/Safety Category 4)
UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. Mounting brackets are sold separately.
Indicator (F3SJ-B@@@@P25/N25)
Emitter
Name of indicator Label ON Blinking
Turns ON when the top beam is receiving Blinks during muting/override, or when cap error
Top-beam-state indicator TOP
light. or connection error occurs.
Turns ON when incidence level is more than Blinks when the safety output is turned OFF
Stable-state indicator STB
170% of the output ON threshold. due to disturbance light or vibration.
ON Green: Turns ON when safety output is ON. Red: Blinks when the F3SJ-B enters a lockout
ON/OFF-state indicator
OFF Red: Turns OFF when safety output is OFF. due to a safety output error.
Turns ON when the F3SJ-B enters a lockout Blinks when the F3SJ-B enters a lockout on
Lockout indicator LOCKOUT
on the receiver. the emitter.
Blinks when the F3SJ-B enters a lockout due
Power indicator POWER Turns ON while the power of the emitter is ON.
to power voltage/noise.
Test indicator TEST --- Blinks when external test is being performed.
MUTING
Muting error indicator --- Blinks during a muting error.
ERROR
Turns ON when muting input 1 is ON under
Muting input 1 indicator MUTE1 ---
the muting system.
Turns ON when muting input 2 is ON under
Muting input 2 indicator MUTE2 ---
the muting system.
Bottom-beam-state indicator BTM Turns ON when the bottom beam is receiving light. Blinks during muting/override.
Receiver
Name of indicator Label ON Blinking
Turns ON when the top beam is receiving Blinks during muting/override, or when cap error
Top-beam-state indicator TOP
light. or connection error occurs.
Turns ON when incidence level is more than Blinks when the safety output is turned OFF
Stable-state indicator STB
170% of the output ON threshold. due to disturbance light or vibration.
ON Green: Turns ON when safety output is ON. Red: Blinks when the F3SJ-B enters a lockout
ON/OFF-state indicator
OFF Red: Turns OFF when safety output is OFF. due to a safety output error.
Turns ON when the F3SJ-B enters a lockout Blinks when the F3SJ-B enters a lockout on
Lockout indicator LOCKOUT
on the emitter. the receiver.
Turns ON when communication between Blinks when the F3SJ-B enters lockout due to a
Communication indicator COM
emitter and receiver is established. communication error between receiver and emitter.
Blinks when the F3SJ-B enters lockout due to
Configuration indicator CFG --- a model type error between receiver and
emitter.
Blinks when the F3SJ-B enters a lockout due to an
Internal error indicator INTERNAL ---
internal error.
INT Turns ON when the F3SJ-B is in interlock Blinks when the F3SJ-B enters a lockout due to a
Interlock indicator
-LK state. wiring error.
External device monitoring Turns ON when an input is given to external Blinks when the F3SJ-B enters a lockout due
EDM
indicator device monitoring input. *1 *2 to an external device monitoring error.
Bottom-beam-state indicator BTM Turns ON when the bottom beam is receiving light. Blinks during muting/override.
*1. It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
*2. The meanings of the indicators are different for the models with the suffix "-01TS". Refer to the F3SJ-B@@@@P25-01TS Safety Light Curtain User's Manual (SCHG-
734) or the specifications of the models with the suffix "-01TS".
34
F3SJ-B
Main Units
F3SJ-B@@@@P25-01TS/-02TS
Model F3SJ-B@@@@P25-01TS F3SJ-B@@@@P25-02TS
Sensor type Type 4 safety light curtain
Setting tool connection *1 Parameter settings: Not available
Safety category Safety purpose of category 4, 3, 2, 1, or B
Detection capability Opaque objects 25mm in diameter
Beam gap (P) 20 mm
Number of beams (n) 8 to 102 10 to 98
Protective height (PH) 185 to 2,065 mm 225 to 1,985 mm
Lens diameter Diameter 5 mm
Operating range 0.2 to 7 m *2 0.2 to 6 m
Response time ON to OFF 15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets)
(under stable light
incident condition) OFF to ON 70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets)
Startup waiting time 2 s max.
Power supply voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA
Emitter max., 46 to 62 beams: 75 mA max., max., 46 to 62 beams: 75 mA max.,
Consumption 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. 66 to 82 beams: 88 mA max., 86 to 98 beams: 99 mA max.
current
(no load) Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA
Receiver max., 46 to 62 beams: 56 mA max., max., 46 to 62 beams: 56 mA max.,
66 to 82 beams: 61 mA max., 86 to 102 beams: 67 mA max. 66 to 82 beams: 61 mA max., 86 to 98 beams: 66 mA max.
Light source (emitted
Infrared LED (870 nm)
wavelength)
Effective aperture angle (EAA) Based on IEC 61496-2.Within +/-2.5° for both emitter and receiver when the detection distance is 3 m or over
Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to
Safety outputs (OSSD)
cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
One PNP transistor outputs, load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to
Auxiliary output 1
cable extension), leak current 1 mA max.
Safety output: On when receiving light
Auxiliary output:
Safety output: On when receiving light • Basic system
Output operation mode
Auxiliary output: Reverse output of safety output Reverse output of safety output
• Muting system
On during muting/override
Test input
ON voltage: 0 V to 1/2 Vs or open *5
OFF voltage: Vs-3 V to Vs *5 ON voltage: Vs-3 V to Vs *5
Input voltage
Reset input, External device monitoring input OFF voltage: 0 V to 1/2 Vs or open *5
ON voltage: Vs-3 V to Vs *5
OFF voltage: 0 V to 1/2 Vs or open *5
Mutual interference
Mutual interference prevention algorithm prevents interference in up to 3 sets.
prevention function
Time division emission by series connection Time division emission by series connection
• Number of connections: up to 3 sets (between F3SJ- • Number of connections: up to 3 sets (between F3SJ-
Series connection B@@@@P25-01TSs only) Other models cannot be connected. B@@@@P25-02TSs only) Other models cannot be connected.
• Total number of beams: up to 192 beams • Total number of beams: up to 192 beams
• Maximum cable length for 2 sets: no longer than 7 m Maximum cable length for 2 sets: no longer than 7 m
• Self test (at power-ON and at power distribution)
Test function • External test (emission stop function by test input)
External device monitoring (basic system)
Safety-related functions External device monitoring Muting (muting system)
Override (muting system)
Connection type Connector method (M12, 8-pin)
Protection circuit Output short-circuit protection, and power supply reverse polarity protection
Ambient temperature Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C
Ambient humidity Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH
Operating ambient light intensity Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC 50/60 Hz, 1 min
Degree of protection IP65 (IEC 60529)
Vibration resistance Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
Shock resistance Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions
Pollution degree Pollution degree 3 (IEC 60664-1)
35
F3SJ-B
Connection method: Prewired connector cable, cable length 0.3 m, connector type (M12, 8-pin), connector: IP67
rated (when mated)
Power cable Number of wires: 8 wires
Cable diameter: Dia. 6 mm
Allowable bending radius: R5 mm
Extension cable 30 m max.
Case: Aluminum
Cap: ABS resin, PBT
Material
Optical cover: PMMA resin (acrylic)
Cable: Oil resistant PVC
Weight (packed state) Weight (g) = (protective height) x 2.7 + 500 Weight (g) = (protective height) x 2.9 + 550
Accessories User's Manual (CD-ROM), Instruction Manual *6
IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices)
Applicable standards IEC 61508-1 to -3, EN 61508-1 to -3 SIL3
ISO 13849-1: 2006, EN ISO 13849-1: 2008 (PLe/Safety Category 4)
UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
Note: 1. The test input logic of the models with the suffix "-01TS" is inverted. Refer to the F3SJ-B@@@@P25-01TS Safety Light Curtain User's
Manual (SCHG-734) for details.
2. Reset mode is fixed with auto reset mode.
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety output at 4 Hz or less, the usable load
inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. Mounting brackets and test rod are sold separately.
Indicator (F3SJ-B@@@@P25-01TS)
Emitter
Name of indicator Label ON Blinking
Turns ON when the top beam is receiving Blinks when cap error or connection error
Top-beam-state indicator TOP
light. occurs.
Turns ON when incidence level is 170% or Blinks when the safety output is turned OFF
Stable-state indicator STB
more of the output ON threshold. due to disturbance light or vibration.
ON Green: Turns ON when safety output is ON. Red: Blinks when the F3SJ-B enters a lockout
ON/OFF-state indicator
OFF Red: Turns ON when safety output is OFF. due to a safety output error.
Turns ON when the F3SJ-B enters a lockout Blinks when the F3SJ-B enters a lockout on
Lockout indicator LOCKOUT
on the receiver. the emitter.
Blinks when the F3SJ-B enters a lockout due
Power indicator POWER Turns ON while the power of the emitter is ON.
to power voltage/noise.
Test indicator TEST --- Blinks when external test is being performed.
Bottom-beam-state indicator BTM Turns ON when the bottom beam is receiving light. ---
Receiver
Name of indicator Label ON Blinking
Turns ON when the top beam is receiving Blinks when cap error or connection error
Top-beam-state indicator TOP
light. occurs.
Turns ON when incidence level is 170% or Blinks when the safety output is turned OFF
Stable-state indicator STB
more of the output ON threshold. due to disturbance light or vibration.
ON Green: Turns ON when safety output is ON. Red: Blinks when the F3SJ-B enters a lockout
ON/OFF-state indicator
OFF Red: Turns ON when safety output is OFF. due to a safety output error.
Turns ON when the F3SJ-B enters a lockout Blinks when the F3SJ-B enters a lockout on
Lockout indicator LOCKOUT
on the emitter. the receiver.
Blinks when the F3SJ-B enters lockout due to
Turns ON when communication between
Communication indicator COM a communication error between receiver and
emitter and receiver is established.
emitter.
Blinks when the F3SJ-B enters lockout due to
Configuration indicator CFG --- a model type error between receiver and
emitter.
Blinks when the F3SJ-B enters a lockout due to an
Internal error indicator INTERNAL ---
internal error.
INT
Interlock indicator Not used Not used
-LK
External device monitoring Turns ON when an input is given to external Blinks when the F3SJ-B enters a lockout due
EDM
indicator device monitoring input. * to an external device monitoring error.
Bottom-beam-state indicator BTM Turns ON when the bottom beam is receiving light. ---
* It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
36
F3SJ-B
Indicator (F3SJ-B@@@@P25-02TS)
Emitter
Name of indicator Label ON Blinking
Turns ON when the top beam is receiving Blinks during muting/override, or when cap error
Top-beam-state indicator TOP
light. or connection error occurs.
Turns ON when incidence level is 170% or Blinks when the safety output is turned OFF
Stable-state indicator STB
more of the output ON threshold. due to disturbance light or vibration.
ON Green: Turns ON when safety output is ON. Red: Blinks when the F3SJ-B enters a lockout
ON/OFF-state indicator
OFF Red: Turns ON when safety output is OFF. due to a safety output error.
Turns ON when the F3SJ-B enters a lockout Blinks when the F3SJ-B enters a lockout on
Lockout indicator LOCKOUT
on the receiver. the emitter.
Blinks when the F3SJ-B enters a lockout due
Power indicator POWER Turns ON while the power of the emitter is ON.
to power voltage/noise.
Test indicator TEST --- Blinks when external test is being performed.
MUTING
Muting error indicator --- Blinks during a muting error.
ERROR
Turns ON when muting input 1 is ON under
Muting input 1 indicator MUTE1 ---
the muting system.
Turns ON when muting input 2 is ON under
Muting input 2 indicator MUTE2 ---
the muting system.
Bottom-beam-state indicator BTM Turns ON when the bottom beam is receiving light. Blinks during muting/override.
Receiver
Name of indicator Label ON Blinking
Turns ON when the top beam is receiving Blinks during muting/override, or when cap error
Top-beam-state indicator TOP
light. or connection error occurs.
Turns ON when incidence level is 170% or Blinks when the safety output is turned OFF
Stable-state indicator STB
more of the output ON threshold. due to disturbance light or vibration.
ON Green: Turns ON when safety output is ON. Red: Blinks when the F3SJ-B enters a lockout
ON/OFF-state indicator
OFF Red: Turns ON when safety output is OFF. due to a safety output error.
Turns ON when the F3SJ-B enters a lockout Blinks when the F3SJ-B enters a lockout on
Lockout indicator LOCKOUT
on the emitter. the receiver.
Blinks when the F3SJ-B enters lockout due to
Turns ON when communication between
Communication indicator COM a communication error between receiver and
emitter and receiver is established.
emitter.
Blinks when the F3SJ-B enters lockout due to
Configuration indicator CFG --- a model type error between receiver and
emitter.
Blinks when the F3SJ-B enters a lockout due to an
Internal error indicator INTERNAL ---
internal error.
INT
Interlock indicator Not used Not used
-LK
External device monitoring Turns ON when an input is given to external Blinks when the F3SJ-B enters a lockout due
EDM
indicator device monitoring input. * to an external device monitoring error.
Bottom-beam-state indicator BTM Turns ON when the bottom beam is receiving light. Blinks during muting/override.
* It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
37
F3SJ-B
Accessories
Control Unit
Item Model F3SP-B1P
Applicable sensor F3SJ-B/A (Only for PNP output type) *
Power supply voltage 24 VDC±10%
Power consumption DC1.7 W max. (not including sensor's current consumption)
Operation time 100 ms max. (not including sensor's response time)
Response time 100 ms max. (not including sensor's response time)
Number of
3NO+1NC
contacts
Relay output
Rated load 250 VAC 5 A (cos ϕ = 1), 30 VDC 5 A L/R = 0 ms
Rated current 5A
Between
Connection M12 connector (8-pin)
sensors
type
Others Terminal block
Weight (packed state) Approx. 280 g
Accessories Instruction manual
* NPN output type cannot be connected. Also, the system cannot be used as a muting system.
Laser Pointer
Item Model F39-PTJ
Applicable sensor F3SJ Series *1
Power supply voltage 4.65 or 4.5 VDC
Battery Three button batteries (SR44 or LR44)
Battery life *2 SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation
Light source Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2, EN/IEC class 2, FDA class II)
Spot diameter (typical value) 6.5 mm at 10 m
Ambient temperature Operating: 0 to 40°C Storage: -15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Material Laser module case: aluminum Mounting bracket: aluminum and stainless
Weight Approx. 220 g (packed)
Accessories Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3), instruction manual
*1. It cannot be mounted to the models with the suffix "-02TS".
*2. Battery life varies depending on a battery used.
38
F3SJ-B
Connections
Basic Wiring Diagram
Wiring when using manual reset mode, external device monitoring (F3SJ-B@@@@P25) [PNP Output]
Receiver
Emitter
F39-JD@A-L F39-JD@A-D
Shield
Interlock select input (White)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
S1 S2 K1 KM1 KM2
*1 *1
KM2 *2
+24 VDC
Power
supply
0V
Wiring when using manual reset mode, external device monitoring (F3SJ-B@@@@N25) [NPN Output]
Receiver
Emitter
F39-JD@A-L F39-JD@A-D
Shield
Interlock select input (White)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
KM1
S1 S2 K1 KM1 KM2
*1 *1
KM2 *2
+24 VDC
Power
supply
0V
39
F3SJ-B
Wiring for manual reset mode and deactivated external device monitoring function (F3SJ-B@@@@P25) [PNP Output]
Receiver
F39-JD@A-L Emitter F39-JD@A-D
Shield
Interlock select input (White)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
(Yellow)
Auxiliary output
External device
S1 S2 K1 KM1 KM2
*1 *1
*2
+24 VDC
Power
supply
0V
Wiring for manual reset mode and deactivated external device monitoring function (F3SJ-B@@@@N25) [NPN Output]
Receiver
Emitter
F39-JD@A-L F39-JD@A-D
Shield
Interlock select input (White)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
(Yellow)
Auxiliary output
External device
S1 S2 K1 KM1 KM2
*1 *1
*2
+24 VDC
Power
supply
0V
40
F3SJ-B
Wiring for auto reset mode and external device monitoring function (F3SJ-B@@@@P25) [PNP Output]
Receiver
Emitter
F39-JD@A-L F39-JD@A-D
Shield
Interlock select input (White)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
S1 S2 K1 KM1 KM2
*1 *1
KM2 *2
+24 VDC
Power
supply
0V
Wiring for auto reset mode and external device monitoring function (F3SJ-B@@@@N25) [NPN Output]
Receiver
Emitter
F39-JD@A-L F39-JD@A-D
Shield
Interlock select input (White)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
KM1
S1 S2
*1 *1 K1 KM1 KM2
KM2 *2
+24 VDC
Power
supply
0V
41
F3SJ-B
Wiring for auto reset mode and deactivated external device monitoring (F3SJ-B@@@@P25) [PNP Output]
Receiver
F39-JD@A-L Emitter F39-JD@A-D
Shield
Interlock select input (White)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
output (Yellow)
Auxiliary
External device
S1 S2 K1 KM1 KM2
*1 *1
*2
+24 VDC
Power
supply
0V
Wiring for auto reset mode and deactivated external device monitoring (F3SJ-B@@@@N25) [NPN Output]
Receiver
Emitter
F39-JD@A-L F39-JD@A-D
Shield
Interlock select input (White)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
output (Yellow)
Auxiliary
External device
S1 S2
*1 *1 K1 KM1 KM2
*2
+24 VDC
Power
supply
0V
42
Shield Shield
Open Open
0 V (Blue) 0 V (Blue)
F39-JD@A-L
Open Test input (Black) F39-JD@A-L
Emitter
Reset input (Yellow) Emitter
Reset input (Yellow)
24 V (Brown)
24 V (Brown)
(Pink)
(Pink)
24 V (Brown)
F39-JD@A-D
Safety output 2 (White)
F39-JD@A-D
Open
Safety output 2 (White)
Open
0 V (Blue)
0 V (Blue)
Shield
Open
Shield
Open
0V
0V
+24 VDC
Power
supply
+24 VDC
Power
supply
Minimum wiring required to check the operation of the F3SJ-B (Wiring for deactivated external device monitoring) (F3SJ-B@@@@P25-02TS) [PNP Output]
Minimum wiring required to check the operation of the F3SJ-B (Wiring for deactivated external device monitoring) (F3SJ-B@@@@P25-01TS) [PNP Output]
F3SJ-B
43
F3SJ-B
Receiver
F39-JD@A-L Emitter F39-JD@A-D
Shield
24V (Brown)
0 V (Blue)
24 V (Brown)
Test input (Black)
KM1
S1 S2 K1 KM1 KM2
*1 *1 KM2 *2
+24 VDC
Power
supply
0V
S1 : External test switch (connect to 24 V if a switch is not required)
S2 : Lockout reset switch (connect to 24 V if a switch is not required)
KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor
K1 : Load or PLC, etc. (for monitoring)
*1. Use a switch for small loads (input specifications: 24 V, 3mA).
*2. F3SJ operates even when K1 is not connected.
F39-JD@A-L F39-JD@A-D
Shield
24V (Brown)
0 V (Blue)
24 V (Brown)
Test input (Black)
KM1
S1 S2 K1 KM1 KM2
*1 *1 KM2 *2
+24 VDC
Power
supply
0V
S1 : External test switch (connect to 0 V if a switch is not required)
S2 : Lockout reset switch (connect to 24 V if a switch is not required)
KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor
K1 : Load or PLC, etc. (for monitoring)
*1. Use a switch for small loads (input specifications: 24 V, 3mA).
*2. F3SJ operates even when K1 is not connected.
44
F3SJ-B
Wiring for deactivated external device monitoring function (F3SJ-B@@@@P25-01TS) [PNP Output]
Receiver
Emitter
㩷 㩷
F39-JD@A-L F39-JD@A-D
Shield
Safety output 2 (White)
0 V (Blue)
0 V (Blue)
24 V (Brown)
24 V (Brown)
Test input (Black)
output (Yellow)
Auxiliary
S1 S2 K1 KM1 KM2
*1 *1
*2
+24 VDC
Power
supply
0V
S1 : External test switch (connect to 24 V if a switch is not required)
S2 : Lockout reset switch (connect to 24 V if a switch is not required)
KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor
K1 : Load or PLC, etc. (for monitoring)
*1. Use a switch for small loads (input specifications: 24 V, 3mA).
*2. F3SJ operates even when K1 is not connected.
Wiring for deactivated external device monitoring function (F3SJ-B@@@@P25-02TS) [PNP Output]
Receiver
Emitter
F39-JD@A-L F39-JD@A-D
Shield
Safety output 2 (White)
0 V (Blue)
0 V (Blue)
24 V (Brown)
24 V (Brown)
Test input (Black)
output (Yellow)
Auxiliary
S1 S2 K1 KM1 KM2
*1 *1
*2
+24 VDC
Power
supply
0V
S1 : External test switch (connect to 0 V if a switch is not required)
S2 : Lockout reset switch (connect to 24 V if a switch is not required)
KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor
K1 : Load or PLC, etc. (for monitoring)
*1. Use a switch for small loads (input specifications: 24 V, 3mA).
*2. F3SJ operates even when K1 is not connected.
45
F3SJ-B
Receiver
Emitter
KM1 to KM4 : Safety relay with force-guided contact (G7SA) or magnetic contactor
- Does not use external device M1, M2 : 3-phase motor
monitoring function ML : External indicator
- G9SX-AD322-T15 settings PLC : Programmable controller
- Auto reset mode (Used for monitoring -- not related to safety system)
(Yellow) *1
Shield
Safety output 2 (White)
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input
output (Yellow)
Reset input
KM1 KM3
External device
KM2
KM2 KM4 Wiring for manual reset mode
S1
S2
KM3
*3 *3 ML
M1 M2 Feedback loop
*4 KM4
+24 V +24 V
AND
Reflector
B1 B2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 KM1
Open Open Open Open OFF
KM2
S3
Workpiece
Control circuit KM3
KM4
A1 F3SJ-B A2 +24 V
A2 S14 S24 S34 S44 S54 L1 X1 X2
+24 VDC Model G9SX-AD322-T15
Power KM1 KM2 KM3 KM4 T31 T32 T33 Y1
supply 0 V PLC,etc.
S3 : Reset switch
Motor controller (operation command)
(Yellow) *1
+24 V (Brown)
0 V (Blue)
0 V (Blue)
Shield
Shield
Muting input 1 (White)
Muting input 2 (Red)
Reset input
(Yellow)
Auxiliary output
External device
KM2
line (-) (Pink)
M
S1
S4
ML
*3 *3 *4
Reflector
B1 B2
Workpiece
Unblocked
A1 F3SJ-B A2 Wiring for auto reset mode Blocked
*5 A1 Safety output
+24 VDC 12 22
Feedback loop
Power Feedback loop
Supply 0 V B1 Safety output
11 21 S3
KM1 KM1 B2 Safety output
S2
KM2 KM2
A2 Safety output
A1 A2 T11 T12 T31 T32 13 23 33 41
3 Muting input 1
4 T31 T32
6
K2 K1 Muting input 2
a K1 1
K2 2
3 Safety output
4
K1 a Control 2 JP 5
b Circuit 5 6
b K2 KM1, KM2 N.O. contact
1
KM1, KM2 N.C. contact
PE T21 T23 T22 A B 14 24 34 42
Model G9SA-301-P
KM1 KM2 External indicator
46
F3SJ-B
Safety output 2
24 VDC
Safety output 1
Reset input
Communication
Communication
0V
Test input
line (+)
line (-)
PIN No. 1 2 3 4 5 6 7 8
2 1
3 8 7
4 6
5
[PNP Output]
Receiver
Emitter
F39-CN5
F39-JD@A-D
F39-JD@B-L
+24 V (Brown)
[NPN Output]
Receiver
Emitter
F39-CN5
F39-JD@A-D
F39-JD@B-L
Shield
0 V (Blue)
Communication line
(+) (Gray)
Communication line
(-) (Pink)
Reset input (Yellow)
Test input (Red)
Safety output 1 (Black)
Safety output 2 (White)
+24 V (Brown)
47
F3SJ-B
Input/Output Circuit Diagram
F3SJ-B@@@@P25 [PNP Output]
Entire Circuit Diagram Input circuit diagram by function
The numbers in circles indicate the connectors' pin numbers.
The words in brackets ([ ]) indicate the signal name for muting system.
<Input circuit (Test, Reset or Interlock Select input)>
Indicator
Brown +24 VDC
2 +24 VDC
Blue
7
Shield <Input circuit (external device monitoring input)>
5 6
Gray Pink
Communication line (+) Communication line (-) +24 VDC
Gray Pink
5 6 Short circuit current:
Brown Receiver
2
5 mA
Main
Circuit
External Device Red
Monitoring Input 8 External device
Circuit
monitoring input
0V
Receiver Safety output 2
White
Main Circuit 2 1
Load
Receiver
Main Circuit 1 Load
Indicator Load
Blue 0V
7
Shield
Blue
7 <Input circuit (external device monitoring input)>
Shield
5 6
Gray Pink +24 VDC
Communication line (+) Communication line (-)
Receiver
5 6 Main
Brown
2 Circuit
Short circuit current:
Safety Load 5 mA
White output 2
1
Receiver 0V
Main Circuit 2
Load
3
Black Safety output 1
Receiver Load
Main Circuit 1
Yellow Auxiliary output
4
48
F3SJ-B
Blue
7 <Input circuit (external device monitoring input)>
Shield
5 6
Gray Pink +24 VDC
Communication line (+) Communication line (-)
Gray Pink Short circuit current:
5 6 Receiver 5 mA
Brown Main
2
Circuit
External Device Red
Monitoring Input 8 External device
Circuit
monitoring input 0V
Receiver
Main Circuit 2 White Safety output 2
1
Load
Receiver
Main Circuit 1 Load
Indication Load
Blue 0V
7
Shield
* The light emission stops when opening the test input line or applying voltage of 0 V to 1/2 Vs to the test input line.
Not used
Red [Muting input 2]
8
Blue
7 <Input circuit (external device monitoring input)>
Shield
5 6
Gray Pink +24 VDC
Communication line (+) Communication line (-)
Gray Pink Short circuit current:
5 6 Receiver 5 mA
Brown Main
2
Circuit
External Device Red
Monitoring Input 8 External device
Circuit
monitoring input 0V
Receiver
Main Circuit 2 White Safety output 2
1
Load
Receiver
Main Circuit 1 Load
Indication Load
Blue 0V
7
Shield
* The light emission stops when applying voltage of Vs-3 V to Vs to the test input line.
49
F3SJ-B
Connection Circuit Examples
Wiring for single F3SJ-B application (F3SJ-B@@@@P25) [PNP Output]
PL/safety category Model Stop category Reset
Safety Light Curtain F3SJ-B@@@@P25
PLe/4 equivalent 0 Manual
Safety Relay G7SA
Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions.
z Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed.
- Using external device monitoring S1: External test switch (connect to 0 V if a switch is not required)
function S2: Interlock/lockout reset switch
Receiver
KM1, KM2: Safety relay with force-guided contact (G7SA)
Emitter
or magnetic contactor
KM3: Solid state contactor (G3J)
M: 3-phase motor
PLC: Programmable controller
(Used for monitoring -- not related to safety system)
F39-JD@A-L F39-JD@A-D
(Gray)
Communication
KM3
line (+)
Unblocked
Reset input (Yellow)
Blocked
monitoring input (Red)
Shield
input (White)
(White)
Shield
(Black)
Safety output 1
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
(Pink)
Interlock select
Safety output 2
S2
M PLC input *
or magnetic contactor
KM3 :Solid state contactor (G3J)
M :3-phase motor
PLC :Programmable controller
(Used for monitoring -- not related to safety system)
F39-JD@A-L F39-JD@A-D
Communication
line (+) (Gray) KM3
Unblocked
Blocked
monitoring input (Red)
(White)
Shield
(Black)
Safety output 1
0 V (Blue)
+24 V (Brown)
Communication
External device
Safety output 2
Shield
Reset input
input (White)
(Black)
0 V (Blue)
+24 V (Brown)
Test input
(Yellow)
Interlock select
S2
M PLC input *
50
F3SJ-B
z Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is turned OFF when the emergency stop switch is pressed.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed while the emer-
gency stop switch is released.
- F3SJ-B settings
Receiver
Emitter
Auxiliary output
Shield
Interlock select input (White)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Test input (Black)
(Yellow)
S3 S4
+24 VDC
Power
supply
0V Unblocked
Blocked
External test switch
(S3)
V1 Si0 Si1 Si2 Si3 Si4 Si5 Si6 Si7 V2 So0 So1 Reset switch
(S2)
KM1
G1 T0 T1 T2 T3 G2 G2 G2 Emergency stop switch
KM2 (S1)
+24 VDC +24 VDC
Power Power Safety output
0 V supply 0 V supply
KM1
11 21
GND KM1,KM2 N.O. contact
GND KM1 KM2
KM2 M
S1 12 22 S2 KM1,KM2 N.C. contact
Feedback loop
51
F3SJ-B
z Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed.
- Using external device monitoring function Wiring for auto reset mode
Receiver
Emitter
S1
S2
H1 L1 J1 H1 X1
PLC
Interlock Test Reset
select
IN1 IN2 OUT
F39-JD@B- L F39-JD@B-D
Wiring when not using
external device monitoring function
External device
monitoring
S1 KM3
S2
T31 T32
Safety output
A2 PE T31 T32 14 24 34 42
M
F3SP-B1P K1,K2 N.O. contact
KM1 +24V
+24 VDC KM1 KM2
KM1,KM2 N.O. contact
Power Feedback loop
KM2
supply 0V K1,K2 N.C. contact
52
F3SJ-B
z Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is turned OFF when the emergency stop switch is pressed.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed while the emer-
gency stop switch is released.
- F3SJ-B settings
- Auto reset mode
Receiver
Emitter
0V (Blue)
Auxiliary output 1
0V (Blue)
Shield
Interlock select input (White)
+24V (Brown)
+24V (Brown)
(Yellow)
or magnetic contactor
KM3 : Solid state contactor (G3J)
KM3 M : 3-phase motor
PLC : Programmable controller
S1
Unblocked
* KM1 Blocked
+24 VDC 12 22
Power Feedback loop External test switch
Supply KM2 (S1)
0V 11 21 S3
Interlock reset switch
KM1 (S2)
S2
M
A1 A2 T11 T12 T31 T32 13 23 33 41 Safety output
3
4 K1,K2 N.O. contact
6
K2 K1
a K1 KM1,KM2 N.O. contact
1
K2 2
3 K1,K2 N.C. contact
4
K1 a Control 2 JP 5
b Circuit 5 6 KM1,KM2 N.C. contact
b K2
PLC input 1
1
PE T21 T23 T22 A B 14 24 34 42
PLC input 2
Model G9SA-301-P
0V
KM1 KM2 PLC output
Note: 1. As the G9SP Safety Controller is a PNP output type, it cannot be connected to the F3SJ-B@@@@N25. Also, a Safety Controller with PNP
output cannot be connected to the F3SJ-B@@@@N25.
2. The G9SA-301-P is a safety relay unit only for NPN output.
53
F3SJ-E/F3SJ-B
Dimensions (Unit: mm)
The dimensions of the F3SJ-E and F3SJ-B are the same except for connector cables and cable leads.
Main Units
Mounting Top/Bottom and Intermediate Brackets
Backside mounting
Mounting screw holes
Top/Bottom Bracket 30 dia.9
(F39-LJB1) 19
43 19
7.5
6.5
5.9
2-M8
2 4-M5
18.3
13
30 30
30
22
7
Intermediate 22 22
5.5
Bracket
C (Protective height)
(F39-LJB2)
C
B
A
B
D
53
42
42
42
2-M5 2-M5 C (protective height): 4-digit number in the table
P (beam gap)
A = C + 69, B = C + 42.2
D = C - 45, E = See table below, P = 20
E
E
Top/Bottom Protective Number of intermediate
Bracket E
(F39-LJB1) height brackets
185 to 1,105 0 ---
22.5
34.5
Side mounting
Top/Bottom dia.9 30 Mounting screw holes
Bracket 19 46 19
7.5
(F39-LJB1) 6.5
5.9
30 2-M8
4-M5
18.3
34.5
30
Intermediate 7
Bracket
(F39-LJB2) 22 22
C (Protective height)
C
B
A
B
53
42
42
42
5.5
2-M5 2-M5
E
34
E
42
Top/Bottom
16
C (protective height): 4-digit number in the table
Bracket
(F39-LJB1) A = C + 69, B = C + 42.2
D = C - 45, E = See table below, P = 20
22.5
height brackets
13.4
12
dia.9
18.3
7.5
6.5
4.3
19
43
16
2
30 Material : Stainless
54
F3SJ-E/F3SJ-B
275 max
42
C (Protective height)
C
F
F
Intermediate
Bracket 15
(F39-LJB2)
42
42
C (protective height): 4-digit number in the table
5.5
275 max
F = See the table below.
4-M5
Protective Number of intermediate
F
7 height brackets
22
185 to 225 1 ---
305 to 1,105 2 555 mm max.
1,185 to 1,585 3 555 mm max.
1,665 to 2,065 4 555 mm max.
Side mounting
45 Mounting screw holes
16 30 37
Intermediate 33
Bracket
(F39-LJB2)
275 max
275 max
42
C (Protective height)
C (Protective height)
F
F
Intermediate
Bracket
(F39-LJB2)
275 max
275 max
45
7
8
8
5.5 5.5
15
15
42 42
53 53
26
(35.7)
(31.5)
(46)
(13)
8
(16)
55
F3SJ-E/F3SJ-B
275 max
2-M6 2-M8
32.1
32.1
C (Protective height)
C
F
F
Quick Mount Bracket
(F39-LJB3-M6 or 15
F39-LJB3-M8)
32.1
32.1
Protective Number of intermediate
F
height brackets
555 mm
185 to 1,105 2
max.
<M6 screw fixed> <M8 screw fixed>
555 mm
1,185 to 1,585 3
max.
555 mm
1,665 to 2,065 4
max.
Side mounting
Mounting screw holes
Quick Mount Bracket 16 30 45
(F39-LJB3-M6 or 33
F39-LJB3-M8)
275 max
2-M6 2-M8
32.1
32.1
C (Protective height)
F
C
F
32.1
275 max
F
height brackets
555 mm
3 185 to 1,105 2
12 max.
45
30
dia.22
30
dia.22
15
15
26
(35.7)
(31.5)
(13)
(46)
8
30
(16)
22
dia.13 dia.17
1.5 1.5
8 8 Material : Stainless
Material : Stainless
56
F3SJ-E/F3SJ-B
Mount Quick Mount M6 Brackets (or Quick Mount M8 Brackets) according to the mounting positions of the emitter and receiver. The positions of
Intermediate Brackets mounted to the emitter and receiver must be aligned with each other.
Side view of the aluminum profile to be mounted Position of the brackets to be mounted to the sensor
Aluminum profile
57
F3SJ-E/F3SJ-B
62
13
30
C (Protective height)
B
A
B
Replacement
Bracket
79.5
(F39-LJB4) 36.5
30
C (Protective height)
B
A
Replacement
Bracket
(F39-LJB4)
79.5
36.5
6.5
19
5.5
43
2
16
30 Material: Stainless
58
F3SJ-E/F3SJ-B
3.25
2-M8
4-M5
7
2
3.25
2
30
30
C(Protective height)
C
B
C
B
A
B
P(beam gap)
D
Contact Mount
22.5
Bracket
(F39-LJB5)
34.5
3.25
10.75
<M5 screw fixed> <M8 screw fixed> C (protective height): 4-digit number in the Model name
A = C + 69
30
B = C + 47.5
D = C - 45
34.5
3.25
30
C
B
C
B
B
A
Contact Mount
Bracket
22.5
(F39-LJB5)
3.25
5
10.75
12 <M5 screw fixed> <M8 screw fixed> C (protective height): 4-digit number in the Model name
A = C + 69
B = C + 47.5
D = C - 45
33
dia. 9
13.5
7.5
6.5
4
19
32
16
2
30 Material: Stainless
Note: 1. The protective height of the F3SJ-E/B series that supports the contact mount bracket is limited.
Protective height allowed for mounting: 185 mm to 1,105 mm (225 mm to 545 mm for the model with the suffix "-02TS")
2. Brackets of other models such as F39-LJB1 cannot be used simultaneously.
59
F3SJ-E/F3SJ-B
F3SJ-B@@@@P25-02TS
Required number of intermediate
brackets
The number of the brackets needed for the F3SJ-B@@@@P25-02TS
differs from the other F3SJ-E/B series. The table below shows the
number of brackets corresponding to the protective heights.
C(Protective height)
Number of top/ Number of
Protective height bottom brackets intermediate
D
/compatible brackets brackets
0225 to 0545 2 0
P(beam gap)
0625 to 1105 2 1
1185 to 1585 2 2
1665 to 1985 2 3
0225 to 0385 2
0465 to 0785 3
0865 to 1105 4
1185 to 1425 5
33.6
1505 to 1825 6
1905 to 1985 7
35
When using the quick mount bracket
Note: For information on dimensions with brackets mounted, refer to
the User's Manual of the F3SJ-B@@@@P25-02TS (SCHG- Protective height Number of quick mount bracket
736). Brackets used are common to other F3SJ-E/B series. 0225 to 0385 2
0465 to 0785 3
0865 to 1105 4
1185 to 1425 5
1505 to 1825 6
1905 to 1985 7
Accessories
Single-end Connector Cable F3SJ-B
F39-JD3A (L = 3 m) F39-JD15A (L = 15 m) 39.5 L*
60
F3SJ-E/F3SJ-B
10
32.1
17.7
18
10.5 24-M3
5.9
7 × 5=35 Mounting screw holes
4.6 dia. 2-4.2 dia. or M4
9 13 max.
76 max. 63 43 84±0.3
5.6
9
45 max. 5 35±0.3
2.3R 111 max.
40.6 32.7
32
35.5
10
101±5
76 23.1
Optical axis
Power button
32
50
40 L
32
15.9 dia.
L = @@@@ - 21 mm Material: PC (protective cover)
61
F3SJ-E/F3SJ-B
13
brackets (2)
3.35
4-M5 19
15
36.1
8
20 M5 bolts with
hexagonal holes
D1
and attached
D1
washers
39
43
10
23
B1
B1
A1
C
Protective
brackets (3) M5
Mounting hole
dia
F3SJ-E/B
.5
16
.5
13
8
36.1
Protective
brackets (1) A1: A1 = C + 72.2
(13)
Protective 20
support B1: B1 = C + 42.2
4-Mounting holes
Number of protective
Protective height D1
brackets (3) used
80
0185 to 0945 0 ---
1025 to 1985 1 B1/2
49
66
2065 2 B1/3
Note: For reference, D1 is the dimension that will not interfere
30
with the intermediate bracket on the Safety Light
30
43
Curtain body.
Backside mounting (using M8 screws)
2-M5 bolts with
hexagonal holes
and attached
washers Mounting screw holes
9.2
2-Mounting
14.5
Protective brackets 39
ia.
7.5
2-M8
34.5
M5 bolts with
20 hexagonal holes
D2
and attached
D2
washers
39
43
10
23
A2
B2
B2
C
Protective M5
brackets (3)
dia
Mounting hole
F3SJ-E/B
.5
16
.5
13
34.5
(7.5)
Protective
Protective brackets (1) C (protective height): 4-digit number in the Model name
(14.5)
support 20
A2: A2 = C + 69
2-Mounting holes B2: B2 = C + 54
Number of protective
Protective height D2
brackets (3) used
80
0185 to 0945 0 ---
1025 to 1985 1 B2/2
49
66
2065 2 B2/3
Note: For reference, D2 is the dimension that will not interfere
with the intermediate bracket on the Safety Light
30
30
43
Curtain body.
62
F3SJ-E/F3SJ-B
F39-PB@@@@
Side mounting (using M5 screws)
2-M5 bolts with
hexagonal holes
and attached
washers 2-Mounting brackets
(F39-LJB1) Mounting screw holes
39
20 Protective
19 brackets (1)
13
3.35
6.7 19
15
4-M5
36.1
M5 bolts with
hexagonal holes
D1
D1
and attached
8 washers
.5
Protective 39
.5
brackets (4)
dia
B1
A1
B1
C
M5
20
Mounting
hole F3SJ-E/B
16
8
(36.1)
3.35
Protective
(15)
brackets (2)
(13)
20
C (protective height): 4-digit number in the Model name
Protective support
4-Mounting holes A1: A1 = C + 72.2
B1: B1 = C + 42.2
Number of protective
Protective height D1
brackets (4) used
0185 to 0945 0 ---
12
30
96
2065 2 B1/3
37
30
31
Note: For reference, D1 is the dimension that will not interfere
80 with the intermediate bracket on the Safety Light
Curtain body.
Side mounting (using M8 screws)
2-Mounting Mounting screw holes
Protective brackets
14.5
39 20
brackets (1) (F39-LJB1)
2
9.
a.
7.5
2-M8
di
2-
34.5
M5 bolts with
hexagonal holes
D2
and attached
8 washers
D2
.5
Protective 39
.5
brackets (4)
dia
B2
A2
B2
C
M5
20
Mounting
hole F3SJ-E/B
16
(34.5)
Protective
(7.5)
20 support
C (protective height): 4-digit number in the Model name
2-Mounting holes A2: A2 = C + 69
B2: B2 = C + 54
Number of protective
Protective height D2
brackets (4) used
0185 to 0945 0 ---
12
30
96
2065 2 B2/3
30
31
Note: For reference, D2 is the dimension that will not interfere
80 with the intermediate bracket on the Safety Light
Curtain body.
63
Safety Light Curtain
F3SJ-A
High-functional ADVANCED type supports
finger protection and special applications.
• Detection capability supports finger protection. Related Function List : Page 97 to 97
information Safety Precautions : Page 99
• Equipped with wide variety of functions such as partial muting and Precautions on Safety : Page 100 to 104
blanking functions.
• The system status can be checked with PC tool.
Ordering Information
Main Units
Safety Light Curtain
Detection Operating Protective Model
Application Beam gap
capability range height (mm) PNP output NPN output
F3SJ-A@@@@P14
Finger protection Dia. 14 mm 9 mm 0.2 to 9 m 245 to 1,271 F3SJ-A@@@@N14
*2
F3SJ-A@@@@P20
Hand protection Dia. 20 mm 15 mm 0.2 to 9 m 245 to 1,505 F3SJ-A@@@@N20
*2
Note: Connection cables are not included in the products. You must purchase optional connector cable.
*1. Models with S-mark certification have an "-S VER2" at the end of the model number.
Example: F3SJ-A0245P30-S VER2
*2. The F3SJ-A-@@@@-TS series with the suffix "-TS" are auto reset fixed models. Function settings using the setting console F39-MC21 or PC
tool F39-GWUM for F3SJ cannot be performed.
(Models with ditection capability 25 mm dia. are also available.)
64
F3SJ-A
65
F3SJ-A
Double-end Connector Cable (2 cables per set, for emitter and receiver)
Control unit for connection with F3SP-B1P, to extend the length under series connection (*)
Appearance Cable Length Specifications Model
0.5 m F39-JDR5B
1m F39-JD1B
3m F39-JD3B
5m F39-JD5B
M12 connector (8-pin)
7m F39-JD7B
10 m F39-JD10B
15 m F39-JD15B
20 m F39-JD20B
* To extend the cable length under series connection, use F39-JJR3W and F39-JD@B in combination. Also, the cable length 20 to 40 m cannot be used.
Power cable (included in the main unit.2 cables per set, for emitter and receiver)
Appearance Cable Length Model
0.3 m F39-JJR3K
0.06 m F39-JJR06L *1
Dedicated cable to materialize series
Side-by-side Series
connection with minimum length without
connection cable
connector cable of the main sensor unit
0.15 m F39-JJR15L *1
66
F3SJ-A
Single-end
Double-end Connector Cable
Connector Cable F39-JD@A-D(Black)
F39-JD@B-L(Gray)
Cable for simple wiring * (2 cables per set, for emitter and receiver)
Appearance Cable length Model Application Remarks
Emitter: 3m Double-end Connector Cable: F39-JD3B-L
F39-JD0303BA
Receiver: 3m Single-end Connector Cable: F39-JD3A-D
Emitter: 3m Double-end Connector Cable: F39-JD3B-L
F39-JD0307BA
Receiver: 7m Single-end Connector Cable: F39-JD7A-D
Emitter: 3m Double-end Connector Cable: F39-JD3B-L
F39-JD0310BA
Receiver: 10m Single-end Connector Cable: F39-JD10A-D
Emitter: 5m Double-end Connector Cable: F39-JD5B-L
F39-JD0503BA
Receiver: 3m Single-end Connector Cable: F39-JD3A-D
Emitter: 5m Double-end Connector Cable: F39-JD5B-L
F39-JD0507BA To reduce wiring
Receiver: 7m Single-end Connector Cable: F39-JD7A-D
Emitter: 5m Double-end Connector Cable: F39-JD5B-L
F39-JD0510BA
Receiver: 10m Single-end Connector Cable: F39-JD10A-D
Emitter: 10m Double-end Connector Cable: F39-JD10B-L
F39-JD1003BA
Receiver: 3m Single-end Connector Cable: F39-JD3A-D
Emitter: 10m Double-end Connector Cable: F39-JD10B-L
F39-JD1007BA
Receiver: 7m Single-end Connector Cable: F39-JD7A-D
Emitter: 10m Double-end Connector Cable: F39-JD10B-L
F39-JD1010BA
Receiver: 10m Single-end Connector Cable: F39-JD10A-D
Note: Cables for the emitter and receiver with other cable lengths than those listed above can also be used in combination. Please contact your
OMRON sales representative for details.
* The cable for the emitter is a double-end connector cable, and the cable for the receiver is a single-end connector cable.
67
F3SJ-A
Wire-saving Devices
Type Appearance Specifications Model Remarks
Model with PNP Muting
F39-TC5P01
Sensor Output
Model with PNP Significantly reduces amount of wiring between
Connector
Override Input
F39-TC5P02 Safety Light Curtains and Muting Sensors.
Terminal Box/
IP67 model for mounting at Sensor installation
Muting Model with NPN Muting
F39-TC5N01 site.
Terminals Sensor Output For details, refer to the OMRON's website.
Model with NPN
F39-TC5N02
Override Input
Laser Pointer
Appearance Output Model
68
F3SJ-A
Note: 1. For indication timing (operation mode), see "Specifications" on page 72.
2. This product is for F3SJ-A only.
Spatter Protection Cover (2 cables per set, common for emitter/receiver) (10% Operating Range Attenuation)
Appearance Model
F39-HJ@@@@
*1 *2
69
F3SJ-A
70
F3SJ-A
Setting Tools *1
Type Appearance Model Remarks
Accessories:
SD Manager CD-ROM (1),
"SD Manager"
F39-CN1 Branch Connector (1),
Setting Support
F39-GWUM *2 Connector Cap (1),
Software for the
2-m Dedicated Cable (1),
F3SJ
0.3-m Dedicated Cable with Plug (1),
Instruction Manual
Accessories:
F39-CN1 Branch Connector (1),
Connector Cap (1),
Setting Console F39-MC21 *3
2-m Dedicated Cable (1),
0.3-m Dedicated Cable with Plug (1),
Instruction Manual
*1. The setting tools described above can be connected only to F3SJ-A models with built-in software of Ver. 2 or later.
Note that the setting tools cannot be used with products shipped prior to December 2005.
The setting tools cannot be used for setting parameters on the F3SJ-A@-TS series, but the monitoring function can be used.
*2. The PC tool supports Windows XP/7.
*3. This product is for use only with the F3SJ-A.It cannot be connected to conventional models of the F3SJ-E/B or F3SN-A series.
Similarly, the F39-MC11 and F39-MT11 Dedicated Consoles for the F3SN-A cannot be connected to the F3SJ-A series.
Protective Bar *1 *2
Type Appearance Model Remarks
71
F3SJ-A
Specifications (For details, refer to the instruction manual or User's manual.)
F3SJ-A@@@@P14/P20/P30/P55/N14/N20/N30/N55
PNP Output F3SJ-A@@@@P14 F3SJ-A@@@@P20 F3SJ-A@@@@P30 F3SJ-A@@@@P55
Model
NPN Output F3SJ-A@@@@N14 F3SJ-A@@@@N20 F3SJ-A@@@@N30 F3SJ-A@@@@N55
Sensor type Type 4 safety light curtain
Version Ver. 2
Setting tool connection Connectable
Safety category Safety purpose of category 4, 3, 2, 1, or B
Opaque objects 14 mm in Opaque objects 20 mm in Opaque objects 30 mm in Opaque objects 55 mm in
Detection capability
diameter diameter diameter diameter
Beam gap (P) 9 mm 15 mm 25 mm 50 mm
Number of beams (n) 26 to 140 16 to 100 10 to 100 6 to 50
Protective height (PH) 245 to 1,271 mm 245 to 1,505 mm 245 to 2,495 mm 270 to 2,470 mm
Lens diameter Diameter 5 mm
0.2 to 9 m (protective height 1,640 mm max.),
Operating range * 0.2 to 7 m (protective height 1,655 mm min.)
(Depending on the setting tool, the detection distance can be shortened to 0.5 m.)
1 set, 1 set,
Response time 0245 to 983: 11 ms to 17.5 ms max. 0245 to 1205: 10 ms to 15 ms max. 1 set: 10 ms to 17.5 ms
(under stable ON to OFF 1 set: 10 ms to 13 ms max.
1,055 or higher: 20 ms to 25 ms 1235 or higher: 17.5 ms to 22.5 ms max.
light incident max. max.
condition)
(For details, see 1 set, 1 set,
"Response Time" OFF to ON 0245 to 983: 44 ms to 70 ms max. 0245 to 1205: 40 ms to 60 ms max.
1 set: 40 ms to 70 ms max. 1 set: 40 ms to 52 ms max.
on page 74.) 1,055 or higher: 80 ms to 100 ms 1235 or higher: 70 ms to 90 ms
max. max.
Startup waiting time 2 s max. (2.2 s max. for series connection)
Power supply voltage (Vs) 24 VDC ±20% (ripple p-p10% max.)
To 50 beams: 76 mA max., 51 to 100 beams: 106 mA max., 101 to 150 beams: 130 mA max.,
Current Emitter
151 to 180 beams: 153 mA max., 201 to 234 beams: 165 mA max.
consumption
(no load) To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max.,
Receiver
151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max.
Light source (emitted wavelength) Infrared LED (870 nm)
Effective aperture angle (EAA) Based on IEC 61496-2.Within ±2.5° for both emitter and receiver when the detection distance is 3 m or over
Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to
PNP cable extension),
outputs allowable capacity load 2.2 μF, leak current 1 mA max.
Safety (This can be different from traditional logic (ON/OFF) because safety circuit is used.)
outputs
(OSSD) Two NPN transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to
NPN cable extension),
Output allowable capacity load 2.2 μF, leak current 2mA max.
(This can be different from traditional logic (ON/OFF) because safety circuit is used.)
One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to
Auxiliary PNP
cable extension),
output 1 outputs
leak current 1 mA max.
(Non-safety
output) NPN One NPN transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to
output cable extension), leak current 1 mA max.
One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable
Auxiliary output 2 PNP extension),
(Non-safety outputs
leak current 1 mA max.
output. Function
for Basic System.) NPN One NPN transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable
output extension), leak current 1 mA max.
Available indicators
External indicator output • Incandescent lamp: 24 VDC, 3 to 7 W
(Non-safety output) • LED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max.
(To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.)
Safety output 1, 2: ON when receiving light
Auxiliary output 1: Inverse of safety output signals (Operation mode can be changed with the setting tool.)
Receiver External indicator output 1: Inverse of safety output signals for a basic system (Operation mode can be changed
with the setting tool.), ON when muting/override for a muting system (Operation mode
Output can be changed with the setting tool.)
operation
mode Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached (Operation mode can be changed
with the setting tool.)
Emitter External indicator output 2: ON when lock-out for a basic system (Operation mode can be changed with the setting tool.)
ON when muting/override for a muting system (Operation mode can be changed with
the setting tool.)
* Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
72
F3SJ-A
73
F3SJ-A
Response Time
Model Protected Height (mm) Number of Beams Response time ms (ON to OFF) Response time ms (OFF to ON)
245 to 263 26 to 28 11 44
281 to 389 30 to 42 12 48
407 to 497 44 to 54 13 52
F3SJ-A@14 Series 515 to 605 56 to 66 14 56
623 to 731 68 to 80 15 60
767 to 983 84 to 108 17.5 70
1,055 to 1,271 116 to 140 20 80
245 16 10 40
275 to 425 18 to 28 11 44
455 to 635 30 to 42 12 48
F3SJ-A@20 Series 665 to 815 44 to 54 13 52
845 to 995 56 to 66 14 56
1,025 to 1,205 68 to 80 15 60
1,235 to 1,505 82 to 100 17.5 70
245 to 395 10 to 16 10 40
420 to 720 17 to 29 11 44
745 to 1,045 30 to 42 12 48
F3SJ-A@30 Series 1,070 to 1,295 43 to 52 13 52
1,395 to 1,620 56 to 65 14 56
1,745 to 1,995 70 to 80 15 60
2,120 to 2,495 85 to 100 17.5 70
270 to 770 6 to 16 10 40
820 to 1,420 17 to 29 11 44
F3SJ-A@55 Series
1,470 to 2,070 30 to 42 12 48
2,120 to 2,470 43 to 50 13 52
Note: Use the following expressions for series connection.
For 2-set series connection:
Response time (ON to OFF): Response time of the 1st unit + Response time of the 2nd unit - 1 (ms), Response time (OFF to ON): Response time calculated by the above x 4 (ms)
For 3-set series connection:
Response time (ON to OFF):
Response time of the 1st unit + Response time of the 2nd unit + Response time of 3rd unit - 5 (ms), Response time (OFF to ON): Response time calculated by the above x 5 (ms)
(For models with the "-TS" suffix, multiply the response time obtained by the above x 5 (ms), or use 200 ms, whichever is less.)
For 4-set series connection:
Response time (ON to OFF): Response time of the 1st unit + Response time of the 2nd unit + Response time of the 3rd unit + Response time of the 4th unit - 8 (ms)
Response time (OFF to ON): Response time calculated by the above x 5 (ms)
Cable Extension Length
Total cable extension length must be no greater than the lengths described below.
When the F3SJ and an external power supply are directly connected, or when the F3SJ is connected to a G9SA-300-SC.
Condition 1 set 2 sets 3 sets 4 sets
Using incandescent lamp for auxiliary output and external indicator output 45 m 40 m 30 m 20 m
Not using incandescent lamp 100 m 60 m 45 m 30 m
74
F3SJ-A
Accessories
Control Unit
Item Model F3SP-B1P
Applicable sensor F3SJ-B/A (Only for PNP output type) *
Power supply voltage 24 VDC±10%
Power consumption DC1.7 W max. (not including sensor's current consumption)
Operation time 100 ms max. (not including sensor's response time)
Response time 10 ms max. (not including sensor's response time)
Number of contacts 3NO+1NC
Relay output Rated load 250 VAC 5 A (cos ϕ = 1), 30 VDC 5 A L/R = 0 ms
Rated current 5A
Connection Between sensors M12 connector (8-pin)
type Others Terminal block
Weight (packed state) Approx. 280 g
Accessories Instruction manual
* NPN output type cannot be connected. Also, the system cannot be used as a muting system.
Laser Pointer
Item Model F39-PTJ
Applicable sensor F3SJ Series
Power supply voltage 4.65 or 4.5 VDC
Battery Three button batteries (SR44 or LR44)
Battery life * SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation
Light source Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2, EN/IEC class 2, FDA class II)
Spot diameter (typical value) 6.5 mm at 10 m
Ambient temperature Operating: 0 to 40°C Storage: -15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Material Laser module case: aluminum Mounting bracket: aluminum and stainless
Weight Approx. 220 g (packed)
Accessories Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3), instruction manual
* Battery life varies depending on a battery used.
Dedicated External Indicator Set
Item Model F39-A01PR-PAC F39-A01PG-PAC F39-A01PY-PAC
Applicable sensor F3SJ-A (Common for PNP/NPN output type. Can be attached to emitters and/or receivers)
Light source Red LED Green LED Yellow LED
Power supply voltage 24 VDC±10% (supplied by sensor)
Consumption current 50 mA max. (supplied by sensor)
Connection type Dedicated accessory connector cable (Sensor side: Dedicated 10-pin connector, Indicator side: M12 8-pin connector)
Indicator (red), Indicator (green), Indicator (yellow),
Set details Dedicated connector cable (0.1 m), Dedicated connector cable (0.1 m), Dedicated connector cable (0.1 m),
Dedicated mounting bracket (1 for each) Dedicated mounting bracket (1 for each) Dedicated mounting bracket (1 for each)
Water-resistant Case
Item Model F39-EJ@@@@-L, F39-EJ@@@@-D
F3SJ-A Series Curtains with a protective height of 600 F3SJ-A Series Curtains with a protective height of 605
Applicable sensor
mm or shorter. mm or longer.
Ambient temperature -10 to 55°C (operation and storage) 13 to 33°C (operation and storage)
Mounting direction No restrictions Vertical direction only (see following diagram)
Operating range 0.2 to 7 m (for a protective height of 1,631 mm max.), 0.2 to 5 m (for a protective height of 1,655 mm min.)
Degree of protection IP67 (IEC 60529) (When assembled according to the application precautions)
Case: Acrylic resin, Rubber: Nitrile rubber, M5 bolt: SUSXM7, M4 bolt: SUS316L,
Material
Cable: Oil-resistant PVC, Plate: SUS304, Mounting Bracket (optional): SUS304
Calculation formula: Weight (g) = 1.5 x @@@@ + 300 ( @@@@ stands for the four digits of the model number (protective height))
Weight (packed state)
(The optional Mounting Brackets come in a set of two, and weigh 120 g. This weight is not included in the above formula.)
Note: 1. Vibration
When using Curtains with a protective height of 605 mm or more, the vibration performance of the applicable sensor is reduced.
Do not use these Curtains in locations that are subject to vibration.
2. Operating range
When using these cases, the operating range of the applicable sensor is reduced.
Check the specifications prior to use.
3. Mounting direction Mounting direction (the cable end and terminating end can be posi-
When using Curtains with a protective height of 605 mm or more, tioned in either direction)
some slackness occurs due to the weight of the Curtain. Horizontal direction Vertical direction
For this reason, mount these Curtains only in the vertical direction. Terminating end Cable end Terminating end
Cable end
75
F3SJ-A
Connections
Basic Wiring Diagram
[PNP Output]
Wiring when using manual reset mode, external device monitoring Wiring when the external device monitoring
S1 : External test switch (connect to 0 V if a switch is not required) function will not be used
Receiver
S2 : Interlock/lockout reset switch
Emitter
KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic • Use a setting tool to set the external device
contactor
K1, K2 : Load or PLC, etc. (for monitoring) monitoring function to "Disabled."
*1. Use a switch for small loads (input specifications: 24 V, 1.8 mA). • When using an auxiliary output 1 that has not been
*2. F3SJ operates even when K1 and K2 are not connected.
(Gray) Communication line (+) changed (output operation mode is "control output
data," and inverse of safety output signals is
(Pink)
monitoring input (Red) "Enabled), the external device monitoring function
Shield
(Yellow)
(Black)
(White)
Shield
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Communication
Auxiliary output 1
Safety output 1
Safety output 2
line (−)
will be disabled when auxiliary output 1 and the
External device
Receiver
*1 *1 or magnetic contactor
*2
K1 : Load or PLC, etc. (for monitoring)
+24 VDC
Power * F3SJ can operate even if K1 is not connected.
supply If K1 is not required, connect auxiliary output 1
0V
to external device monitoring input only.
(Gray)
Wiring for auto reset mode Communication line (+)
(Pink)
• The auto reset mode will be enabled Communication line (−)
Emitter
Shield
Safety output 2 (White)
0 V (Blue)
+24 V (Brown)
(Yellow)
Auxiliary output 1
below.
External device
(Gray) Communication line (+)
+24 V (Brown)
Reset input (Yellow)
K1 KM1 KM2
*
S1 : External test switch
+24 VDC
(connect to 0 V if a switch is not required)
Power
S3 : Lockout reset switch supply
(connect to 24 V if a switch is not required) 0V
K2 : Load or PLC, etc. (for monitoring)
K2 S1 S3
*1. Use a switch for small loads *1 *1
*2
(Input specifications: 24 V, 1.8 mA). +24 VDC
Power
*2. F3SJ operates even when K2 is not connected. supply
0V
[NPN Output]
Wiring when using manual reset mode, external device monitoring Wiring when the external device monitoring
S1 : External test switch (connect to 24 V if a switch is not required)
function will not be used
Receiver
(Black)
(White)
Shield
Interlock select input (White)
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
(Yellow)
Reset input (Yellow)
Communication
Auxiliary output 1
Safety output 1
Safety output 2
shown below.
KM1 KM1, KM2 : Safety relay with force-guided contact (G7SA)
Receiver
Shield
Safety output 2 (White)
0 V (Blue)
+24 V (Brown)
(Yellow)
Auxiliary output 1
External device
+24 V (Brown)
Reset input (Yellow)
+24 VDC
Power
supply
0V
76
F3SJ-A
Receiver
Emitter
(output operation mode is "safety output data," and inverse of
control output signals is "Enabled), the external device monitoring
function will be disabled when auxiliary output 1 and the external
device monitoring input are connected.
(Gray)
Communication line (+)
(Pink)
Muting input 2
(Red)
Muting input 1
(White)
(Black)
(White)
Shield
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
(Yellow)
Reset input (Yellow)
Auxiliary output 1
Safety output 1
Safety output 2
Communication
line (-)
External device
KM1
K1 KM1 KM2
B1 A1 S1 S2
*5 *5 *1 *1*2 KM2 *3
*4
+24 VDC
Power
supply
0V
*1. Use a switch for small loads (input specifications: 24 V, 1.8 mA).
*2. When using the interlock function, this also functions as an interlock reset switch. (Must be set with a setting tool.)
*3. F3SJ operates even when K1 is not connected.
*4. Connect the muting lamp to either the external indicator output or auxiliary output 1 for the emitter or the receiver. When
connecting the muting lamp to auxiliary output 1, the parameter must be changed with a setting tool.
*5. Two-wire type muting sensor cannot be used.
[NPN Output]
Wiring when using muting and external device monitoring functions When external device monitoring function is not required
• Use a setting tool to set the external device monitoring function to
*4 M1
*4 "Disabled."
• When using an auxiliary output 1 that has not been changed
Receiver
Emitter
(Pink)
monitoring input (Red)
Shield
Muting input 2
(Red)
Muting input 1
(White)
(Black)
(White)
Shield
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
(Yellow)
Reset input (Yellow)
Auxiliary output 1
Safety output 1
Safety output 2
Communication
line (-)
External device
KM1
K1 KM1 KM2
B1 A1 S1 S2 KM2 *3 *4
*5 *5 *1 *1*2 +24 VDC
Power
supply
0V
77
F3SJ-A
Safety output 2
24 VDC
Safety output 1
Reset input
Communication
Communication
0V
Test input
line (+)
line (-)
PIN No. 1 2 3 4 5 6 7 8
2 1
3 8 7
4 6
5
[PNP Output]
Receiver
Emitter
F39-CN5
F39-JD@A-D
F39-JD@B-L
+24 V (Brown)
[NPN Output]
Receiver
Emitter
F39-CN5
F39-JD@A-D
F39-JD@B-L
Shield
0 V (Blue)
Communication line
(+) (Gray)
Communication line
(-) (Pink)
Reset input (Yellow)
Test input (Red)
Safety output 1 (Black)
Safety output 2 (White)
+24 V (Brown)
78
F3SJ-A
Input/Output Circuit Diagram
Entire Circuit Diagram
[PNP Output]
The numbers in circles indicate the connectors' pin numbers.
The black circles indicate connectors for series connection.
The words in brackets ([ ]) indicate the signal name for muting system.
Auxiliary output 2
[Muting input 2] *2
8 Red
Blue
7
Shield
5 6
Gray Pink
Communication line (+) Communication line (−)
Gray Pink
5 6
Brown
2
Receiver
Main Circuit 2 White Safety output 2
1
Blue
Load
Indicator Load
Blue 0V
7
Shield
*1. Open or muting input 1 for models with the "-TS" suffix.
*2. Open or muting input 2 for models with the "-TS" suffix.
[NPN Output]
The numbers in circles indicate the connectors' pin numbers.
The black circles indicate connectors for series connection.
The words in brackets ([ ]) indicate the signal name for muting system.
Indicator
External indicator output 2 +24 VDC
Brown
Brown 2
Blue
7
Shield
5 6
Gray Pink
Communication line (+) Communication line (−)
Gray Pink
5 6
Brown
2
Load
External indicator output 1 White
1
Brown Safety output 2
Receiver Load
Main Circuit 2
Black
Blue 3
Safety output 1
Load
Yellow
Receiver 4
Auxiliary output 1
Main Circuit 1
79
F3SJ-A
Connection Circuit Examples
Wiring for single F3SJ-A application [PNP Output]
PL/safety category Model Stop category Reset
Safety Light Curtain F3SJ-A@@@@P@@
PLe/4 equivalent 0 Manual
Safety Relay G7SA
Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming
the usage conditions.
V Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed.
- Using external device monitoring function
Emitter Receiver
S1 : External test switch
(connect to 0 V if a switch is not required)
S2 : Interlock/lockout reset switch
KM, KM2 : Safety relay with force-guided contact (G7SA)
or magnetic contactor
K1 : Load, PLC (for monitor)
KM3 : Solid state contactor (G3J)
M : 3-phase motor
PLC : Programmable controller
(Used for monitoring -- not related to safety system)
F39-JD@A-L F39-JD@A-D
(Gray)
Communication line (+) Unblocked
KM3
Blocked
External test switch (S1)
Reset input (Yellow)
(Black)
(White)
Shield
Interlock selection input (White)
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
(Pink)
Safety output 1
Safety output 2
S2
PLC input *
M
+24 VDC IN OUT PLC output
Power
supply PLC * Auxiliary output 1 gives inverted signal of safety output (default setting).
0V
80
F3SJ-A
V Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed.
- Using external device monitoring function Wiring for auto reset mode
S1
S2
Emitter Receiver
H1 L1 J1 H1 X1
Unblocked
A1 H1 L1 J1 H1 X1 P1 13 23 33 41 Blocked
Interlock
selection Test Reset Auxiliary External test switch (S1)
output 1
Safety Safety KM1
output 1 output 2 K1 Reset switch (S2)
K2 KM2
Safety output
K1 K2
External device
monitoring K1,K2 N.O. contact
81
F3SJ-A
V Application Overview
• The power supply to the motor M1 is turned OFF immediately when the beam is blocked, and stop command is sent to the motor
controller for the motor M2.
• The power supply to the motor M2 is turned OFF after OFF-delay time.
• The power supply to the motor M1 and M2 is kept OFF until the beams are unblocked.
- F3SJ settings Wiring for manual reset mode
- Auto reset mode
- Not using external device monitoring
- G9SX-AD322-T15 settings
Emitter Receiver - Auto reset mode Feedback loop
- Using feedback loop
input (White)
Auxiliary output 1
Shield
Safety output 2 (White)
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Reset input (Yellow)
(Yellow)
Communication
Feedback loop
line (−)
External device
Open
KM2 S34
S1
S2
Motor controller
82
F3SJ-A
V Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed.
- Using external device monitoring function
Emitter Receiver
Communication Unblocked
line (+) (Gray) KM3 Blocked
Safety output 1 (Black)
output 2 (Red)
Shield
Interlock selection input (White)
Communication
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Reset input (Yellow)
External device
Safety output
KM1 KM1
KM1,KM2 N.O. contact
KM1 KM2
S1
K1
S2
KM2
KM2
KM1,KM2 N.C.contact
PLC input *
M PLC output
+24 VDC IN OUT * Auxiliary output 1 gives inverted signal of safety output (default setting).
Power
supply PLC
0V
83
F3SJ-A
V Application Overview
• The power supply to the motor M is turned OFF when the beam is blocked.
• The power supply to the motor M is turned OFF when the emergency stop switch is pressed.
• The power supply to the motor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed while the emer-
gency stop switch is released.
- F3SJ settings
- Auto reset mode
- Does not use external device monitoring function
Emitter Receiver - G9SA-301-P settings
Wiring for auto reset mode
- Manual reset mode
- Using feedback loop
- Using emergency stop switch
KM1
KM2
T31 T32
F39-JD@A-L F39-JD@A-D K1
K2
Communication
line (+) (Gray) PLC Control
Interlock selection input (White)
Circuit
monitoring input (Red)
output 2 (White)
Shield
0 V (Blue)
0 V (Blue)
+24 V (Brown)
+24 V (Brown)
Communication
Reset input (Yellow)
output 1 (Yellow)
output 1 (Black)
A B
Auxiliary
Safety
Safety
S1
S4
KM3
Open
*1 KM1 Unblocked
+24 VDC 12 22 Blocked
Power
supply 0 V KM2 External test switch
11 21 S3 (S1)
KM1 Interlock reset switch
(S2)
S2
84
F3SJ-A
Dimensions (Unit: mm)
Main Units
When Using Standard Mounting Brackets
Backside mounting 2-Top/bottom 30 Mounting screw holes
mounting brackets 5.5 20
(13.75)
2-Mounting holes 4-M5 20
16.5
1 3.75
6.25
Top/bottom
mounting bracket 30
(F39-LJ1) 24 31
22
Intermediate 7 22
mounting 2-M5
bracket 5.5
Intermediate B A
mounting bracket 42 B
D 53 42
(F39-LJ3) C (Protective C (protective height): 4-digit number in the table
height)
2-Mounting holes
A = C + 74, B = C + 46.5
D = C - 20, E = See table below.
Beam E Protective Number of intermediate
E*
E
height brackets
245 to 596 0 ---
10 4-Mounting holes
300 37 600 to 1,130 1 E = B/2
F39-LJ3
Horizontal angle: ±10° 6 dia. 6.5 dia. 13.75 1,136 to 1,658 2 E = B/3
2-Mounting holes
1,660 to 2,180 3 E = B/4
43 9 dia.
24
5.5
31
15 B A 15 B
53 D
11 C (Protective
2-M5
36 height)
43 31 C (protective height): 4-digit number in the table
A = C + 74, B = C + 46.5
Beam
E E D = C - 20, E = See table below.
5
Protective Number of intermediate
10 E*
4-Mounting height brackets
holes 10
300 37 245 to 596 0 ---
6 dia.
13.75
6.5 dia. 600 to 1,130 1 E = B/2
2-Mounting holes
43 9 dia. 1,136 to 1,658 2 E = B/3
F39-LJ3 1,660 to 2,180 3 E = B/4
M12 Waterproof connector
Horizontal angle: ±10°
2,195 to 2,500 4 E = B/5
51
* Use E = 530 or less when none of the E values shown
above are used.
53
30
9 dia.
5.5 2
6.5 dia. Material: Brass
16.5 8 18 36.5
5.6
14.5 11
2-M3 .
21 5.5 dia
Through holes 30
19.6 3.5
21 2-
10
Material: Stainless steel Material: Stainless steel
85
F3SJ-A
A B C (Protective height) B
5
19
0.3
37 Dimensions A to C
9.7
20
17.25 6.5 dia. A C + 74
9 dia.
B C + 39.5
44
4-digit number of the model
35 C
2 name (protective height)
B C (Protective 42 B
height)
16
F F
53 42 42
45
Side mounting 24 25
43 46
36 Mounting screw holes
45 6-M5
11
F39-LJ3 15
Material:Zinc die-cast/ 5.5
stainless
Horizontal angle: ±10°
C (Protective
B height) B
15
F F
16 5
15
53
15
45
51 30
2
24 5
43
86
F3SJ-A
When only F39-LJ3 free-location mounting brackets are used without standard brackets, allow a space of at least 350 mm between the brackets.
The number of brackets required varies according to the protective height. For details about the number of required brackets, refer to the table
below.
The standard included intermediate brackets are the same as the F39-LJ3 free-location mounting brackets. Purchase brackets as necessary if
there are fewer intermediate brackets than required. When intermediate brackets are included, they can be used as free-location mounting
brackets.
Required number of F39-LJ3 free-location mounting brackets for 1 F3SJ set (emitter/receiver) (2 pieces are included with F39-LJ3)
Number of included free location Number of free location brackets to Number of free location bracket sets
Protective height
brackets as intermediate brackets mount F3SJ to be purchased (pcs)
245 to 440 0 4 2 sets (4)
443 to 596 0 6 3 sets (6)
600 to 785 2 6 2 sets (4)
794 to 1,130 2 8 3 sets (6)
1,136 to 1,140 4 8 2 sets (4)
1,145 to 1,490 4 10 3 sets (6)
1,495 to 1,658 4 12 4 sets (8)
1,660 to 1,840 6 12 3 sets (6)
1,845 to 2,180 6 14 4 sets (8)
2,195 to 2,500 8 16 4 sets (8)
A C (Protective height)
B
B
45
Dimensions A to C 21.5 19(*)
A C + 109
B C + 66
30
4-digit number of the model
C * Using M5 bolt, available range for mounting is
name (protective height)
26 18 to 20
Note: Refer to the User's Manual for the dimensions for side mounting.
87
F3SJ-A
C (Protective height) B A B
54.5
Dimensions A to C 20
13
A C + 109 4-Mounting holes
B C + 69
4-digit number of the model
C
name (protective height)
C (Protective height) B A B
25.65
11.5 16.65 20
Dimensions A to C
A C + 23
B C - 10.3
Note: Because the F39-LJ8 cannot be mounted
4-digit number of the model together with an intermediate bracket, keep the
C
name (protective height) 33
protective height at 600 mm max.
88
F3SJ-A
Guide to Replacing F3SJ-A with F3SJ-E/B (Including models whose production will be discontinued)
F3SJ-A to F3SJ-E/B replacement correspondence table (F3SJ-A mounting holes can be used without modification)
To check available brackets for replacement, refer to the table below.
To check dimensions when mounting brackets, refer to page 91.
The values in the table correspond to in the model name, meaning the protective height (mm) of a sensor.
F3SJ-A Replacement F3SJ-E/B Available bracket for replacement
Top/bottom bracket Compatible bracket
@@@@P(N)20 @@@@P(N)25 @@@@P(N)30 @@@@P(N)25
(F39-LJB1) (F39-LJB4)
0245 0260 0245
0260 0280 0270
0225 ✓
0275 0295
0290
0300 ✓ ✓
0305 0320 0320
0320 0340 0345 0305
0335 0360 0370 ✓
0350
0365
0380 0380 ✓ ✓
0395 0400 0395
0410 0420 0420 0385
0425 0440 0445 ✓
0440
0455
0460 ✓ ✓
0470 0480 0470
0485 0500 0495 0465
0500 0520 0520 ✓
0515
0530
0540 ✓ ✓
0545 0560 0545
0560 0580 0570 0545
0575 0600 0595 ✓
0590
0605
0620 0620 0620 ✓ ✓
0635 0640 0645
0650 0660 0670 0625
0665 0680 0695 ✓
0680
0695
0700 ✓ ✓
0710 0720 0720
0725 0740 0745 0705
0740 0760 0770 ✓
0755
0770
0780 ✓ ✓
0785 0800 0795
0800 0820 0820 0785
0815 0840 0845 ✓
0830
0845
0860 0860 ✓ ✓
0875 0880 0870
0890 0900 0895 0865
0905 0920 0920 ✓
0920
0935
0940 ✓ ✓
0950 0960 0945
0965 0980 0970 0945
0980 01000 0995 ✓
0995
01010
1020 1020 ✓ ✓
1025 1040 1045
1040 1060 1070
1055 1080 1095 1025
✓
1070
1085
1100
1100 ✓ ✓
1115 1120 1120
1130 1140 1145 1105
1145 1160 1170 ✓
1160
1175
89
F3SJ-A
Note: 1. Protective height and detection capability vary according to replacement. Check the safe design of your device before use.
2. The maximum protective height of F3SJ-E is 1,105 mm. Only the F3SJ-B can be replaced for the protective height of 1,185 or more.
90
F3SJ-A
26 43
F3SJ-A F3SJ-E/B
F3SJ-A F3SJ-E/B
F3SJ-A F3SJ-E/B
(Free-location bracket used) (Intermediate bracket used)
Mounting hole pitch (mm) 15 42
Dimensional drawing of mounting hole for side mounting using intermediate bracket
Optical surface 7 Optical surface
5.5
53
53
42
15
5.5
11
34 34
F3SJ-A F3SJ-E/B
91
F3SJ-A
B A
C (Protective height) B
19.9
32 21
11.5 16.5 20
Dimensions A to C
A C + 23
B C - 10
4-digit number of the model
C
name (protective height)
Outward-facing mounting 30
44
C (Protective height) B A B
6.5 dia.
5.8
32
4.2 15.5 20
9 dia. Dimensions A to C
19.9
A C + 65
B C + 34
4-digit number of the model
C
name (protective height)
30
2
44
C (Protective height)
B A B
6.5 dia.
5.8
32.5 32
4.2 15.5 20
9 dia.
19.9 Dimensions A to C
A C + 44
B C + 12
4-digit number of the model
C
30
name (protective height)
92
F3SJ-A
Accessories
Single-end Connector Cable
F39-JD3A (L = 3 m) F39-JD15A (L = 15 m) 39.5 L*
10
32.1
17.7
18
Control Unit
F3SP-B1P Emitter
Receiver
91
10.5 24-M3
76 max. 63 43 84±0.3
5.6
9
45 max. 5 35±0.3
2.3R 111 max.
Laser Pointer
F39-PTJ 32.7
40.6
101±5
76 23.1
Optical axis
Power button
50
40
32
15.9 dia.
93
F3SJ-A
20
173
90
9 dia.
6.5 dia.
16 18
6 2
6
19 32 Material: Stainless steel
34
32 32
10
Four digits in the model number (protective height) − 10 29.5
Mirrors
F39-MLG@ 145 8-7 dia.
102
52
94
F3SJ-A
Protective Bar
F39-PJ@@@@-S
Backside mounting
Mounting screw holes
24 30 Mounting bracket (2) 3-M5 bolts with
hexagonal holes and
9 dia.
20
5.5 attached washers 20
When using M5 When using M6, M8
6.5 dia. (13.75) 2-M8
16.5 4-M5 3.75 6.25
(6)
(37)
1
2-M6
D
Sensor D D
16
8
5.5 dia. 10
23
43 39 39
B C (Protective A B B
height)
M5 M5
Mounting hole
Intermediate
brackets
(3)
(37)
20 3.75 6.25
2-Mounting holes (13.75) 20
(6) 4-M3 bolts with
Protective support
2-Mounting holes 4-Mounting holes
Mounting
hexagonal holes
and attached
C (protective height): 4-digit number in the table
bracket (1) washers A = C + 74,
B = C + 46.5
Protective Number of intermediate
15 D
height brackets used (3)
64
245 to 995 0 ---
1,001 to 2,000 1 B/2
20
69
2,009 to 2,500 2 B/3
Note: For reference, D is the dimension that will
not interfere with the intermediate bracket on
the Safety Light Curtain body.
Side mounting
Mounting screw holes
30 24 Mounting bracket (2) 3-M5 bolts with
9 dia.
20 4 hexagonal holes and
attached washers 20
When using M5 When using M6, M8
5.5
6.5 dia. (13.75) 2-M8
16.5 4-M5 3.75 6.25
(6)
(37)
5
2-M6
D D D
23
Intermediate
8 brackets (4)
for side
mounting *
10 20
C (Protective 39 39
height)
B A B B
5.5 dia. M5 M5
36 Mounting hole
Sensor
(37)
95
F3SJ-A
Water-resistant Case
F39-EJ@@@@-L(D)
Backside mounting 32
B B
A B C D
(Protective
height)
Dimensions A to D
22
2 A C + 108
32
16 B C + 76
20 8
20 4-digit number of the model
C
2-Mounting Brackets name (protective height)
(F39-EJ-R)
* The Mounting Brackets (F39-EJ-R) are sold
* D C + 44
separately.
Side mounting
32
Mounting screw holes
20
9 dia.
6.5 dia. 5.5 60.5 dia. 2-M8
8 4-M5 8
(16)
13.5
2 2-M6 2
B B
A B C
(ProtectiveD
height)
22
2
Dimensions A to D
16
32 A C + 108
20
20
8 B C + 76
2-Mounting Brackets
(F39-EJ-S) * 4-digit number of the model
C
name (protective height)
* The Mounting Brackets (F39-EJ-S) are sold D C + 44
separately.
96
F3SJ-E/F3SJ-B/F3SJ-A
Function List
Functions that can be used on F3SJ are shown as follows: Refer to the F3SJ User's Manual for details. For manual number, check the "Related
Manuals" at the end of the catalog.
✓: Can be used.
X: Cannot be used.
Basic functions
Function F3SJ-E (EASY) F3SJ-B (BASIC) F3SJ-A (ADVANCED)
Self-test function ✓ ✓ ✓
External test function ✓ ✓ ✓
External device monitoring function X ✓* ✓
Interlock function X ✓* ✓
Auxiliary output function X ✓ ✓
Muting function X ✓ ✓
* Cannot be used at muting.
97
F3SJ-E/F3SJ-B/F3SJ-A
Auto Reset
When the interrupting object is removed from the detection zone, the
safety outputs automatically turn ON. Auto reset is used on machines
where a worker is not able to enter the area between the detection
zone and the hazardous part of the machine.
Manual Reset
When a reset input is given while no interrupting object exists in a
detection zone, the safety outputs turn ON. This allows the machine
to be manually reset using a reset switch after ensuring safety,
preventing unexpected startup.
Muting Function
Muting function temporarily disables safety function of the F3SJ,
keeping safety output ON even if beams are interrupted.
This makes it possible to install safety light curtains for AGV passage,
enabling both safety and productivity.
Override Function
The override function turns the safety outputs ON when the muting
start condition is not satisfied. If a workpiece stops while passing
through the F3SJ, as shown below, causing a muting error, the
normal state cannot be recovered unless the workpiece is removed
from the muting sensors and the detection field of the F3SJ. However,
the override function will mute the safety outputs of the F3SJ so that
the conveyor can be restarted to move the workpiece out of the
muting sensors and detection zone.
98
F3SJ-E/F3SJ-B/F3SJ-A
Safety Precautions
Description shown below is only a guideline to choose a safety (4) JIS standards
sensor. To use the product properly, you must read its instruction JIS B 9704-1 (type 4 ESPE),
manual that comes with the product. JIS B 9704-2 (type 4 AOPD)
(5) North American standards:
Legislation and Standards UL 61496-1 (type 4 ESPE),
1. Application of a sensor alone cannot receive type approval UL 61496-2 (type 4 AOPD),
provided by Article 44-2 of the Industrial Safety and Health Act of UL 508, UL 1998, CAN/CSA C22.2 No.14,
Japan. It is necessary to apply it in a system. CAN/CSA C22.2 No.0.8
Therefore, when using the F3SJ in Japan as a "safety system for
pressing or shearing machines" prescribed in Article 42 of that law, 5. The F3SJ received the following certification from the EU-
the system must receive type approval. accredited body, TÜV SÜD:
• EC type test based on machinery directive
2. The F3SJ is electro-sensitive protective equipment (ESPE) in
Type 4 ESPE (EN 61496-1),
accordance with European Union (EU) Machinery Directive Index
Annex V, Item 2. Type 4 AOPD (CLC/TS 61496-2)
3. The F3SJ-E/B is in conformity with the following standards: 6. The F3SJ is scheduled to received certificates of UL listing for US
(1) EC legislation and Canadian safety standards from the Third Party Assessment
Machinery Directive 2006/42/EC Body UL.
EMC Directive 2004/108/EC • Type 4 ESPE (UL 61496-1),
(2) European standards Type 4 AOPD (UL 61496-2)
EN 61496-1 (type 4 ESPE),
CLC/TS 61496-2 (type 4 AOPD), 7. The F3SJ is designed according to the standards listed below. To
EN 61508-1 through -3 (SIL3), make sure that the final system complies with the following
EN 61000-6-4, standards and regulations, you are asked to design and use it in
EN ISO 13849-1:2008 (PLe/Safety Category 4) accordance with all other related standards, laws, and regulations.
(3) International standards If you have any questions, consult with specialized organizations
IEC 61496-1 (type 4 ESPE), such as the body responsible for prescribing and/or enforcing
IEC 61496-2 (type 4 AOPD), machinery safety regulations in the location where the equipment
IEC 61508-1 through -3 (SIL3), is to be used.
ISO 13849-1:2006 (PLe/Safety Category 4) • European standards: EN 415-4, EN 692, EN 693
(4) JIS standards • US Occupational Safety and Health Standards: OSHA 29 CFR
JIS B 9704-1 (type 4 ESPE), 1910.212
JIS B 9704-2 (type 4 AOPD)
• US Occupational Safety and Health Standards: OSHA 29 CFR
(5) North American standards:
UL 61496-1 (type 4 ESPE), 1910.217
UL 61496-2 (type 4 AOPD), • American National Standards: ANSI B11.1 to B11.19
UL 508, UL 1998, CAN/CSA C22.2 No.14, • American National Standards: ANSI/RIA 15.06
CAN/CSA C22.2 No.0.8 • Canadian Standards Association CSA Z142, Z432, Z434
4. The F3SJ-A is in conformity with the following standards: • SEMI Standards SEMI S2
(1) EC legislation
Machinery Directive 2006/42/EC
EMC Directive 2004/108/EC
(2) European standards
EN 61496-1 (type 4 ESPE),
CLC/TS 61496-2 (type 4 AOPD),
EN61508-1 through -3 (SIL3)
EN ISO 13849-1:2008 (PLe/Safety Category 4)
(3) International standardsI
EC 61496-1 (type 4 ESPE),
IEC 61496-2 (type 4 AOPD),
IEC 61508-1 through -3 (SIL3)
ISO13849-1: 2006 (PLe/Safety Category 4)
99
F3SJ-E/F3SJ-B/F3SJ-A
Precautions on Safety
Indication and meaning for safe use For installation
This instruction manual describes notification and/or waning with WARNING
indication and symbols as shown below for safe use of F3SJ. This
notification describes very important details for safety. You must F3SJ-E F3SJ-B F3SJ-A
follow the description. Shown below are indication and symbols. Make sure to test the operation of the F3SJ after installation to
verify that the F3SJ operates as intended. Make sure to stop the
Indicates a potentially hazardous situation
machine until the test is complete.
which, if not avoided, will result in minor or
Unintended function settings may cause a person to go
WARNING moderate injury, or may result in serious
undetected, resulting in serious injury.
injury or death. Also, a serious damage on
property may be caused. F3SJ-E F3SJ-B F3SJ-A
Make sure to install the F3SJ at the safe distance from the
If you fail to use a product properly, it may hazardous part of the equipment. Otherwise, the machine may
CAUTION result in injuries or damage on property. not stop before a person reaches the hazardous part, resulting
in serious injury.
Meanings of Alert Symbols
F3SJ-E F3SJ-B F3SJ-A
Install a protective structure so that the hazardous part of a
Inhibited machine can only be reached by passing through the sensor's
Indicates general inhibition. detection zone. Install the sensors so that part of the person is
always present in the detection zone when working in a
machine's hazardous zones. If a person is able to step into the
Alert Statements in this Manual hazardous zone of a machine and remain behind the 's detection
F3SJ-E . . . . . Description applied to F3SJ-E models. zone, configure the system with an interlock function that
F3SJ-B . . . . . Description applied to F3SJ-B models. prevents the machine from being restarted. Otherwise it may
F3SJ-A . . . . . Description applied to F3SJ-A models. result in heavy injury.
100
F3SJ-E/F3SJ-B/F3SJ-A
F3SJ-A
Muting times must be precisely set according to the application
by qualified personnel who have received appropriate training.
In particular, if the muting time limit is to be set to infinity, the Reflector
person who makes the setting must bear responsibility.
Position with detection
F3SJ-B F3SJ-A Position with retro-reflection zone bent at 90°
Use two independent input devices for the muting inputs.
F3SJ-E F3SJ-B F3SJ-A
F3SJ-B F3SJ-A When using series connections, perform inspection of all
Install the F3SJ, Muting Sensors, or a protective wall so that connected F3SJs as instructed in the User's Manual.
workers cannot enter hazardous areas while muting is in effect,
and set muting times.
For wiring
F3SJ-B F3SJ-A
WARNING
Position the switch that is used to activate the override function
in a location where the entire hazardous area can be seen, and F3SJ-E F3SJ-B F3SJ-A
where the switch cannot be operated from inside the hazardous [For PNP output]
area. Make sure that nobody is in the hazardous area before Connect the load between the output and 0V line.
activating the override function. [For NPN output]
Connect the load between the output and +24V line. If +24 V and
F3SJ-E F3SJ-B F3SJ-A 0 V are connected, it is dangerous because operation mode is
Install the sensor system so that it is not affected by reflective inversed to "ON when interrupted".
surfaces. Failure to do so may hinder detection, resulting in
F3SJ-E F3SJ-B F3SJ-A
serious injury.
[For PNP output]
F3SJ-E F3SJ-B F3SJ-A Do not short-circuit an output line to +24 V line. Otherwise, the
When using more than 1 set of F3SJ, install them so that mutual output is always ON. Also, 0 V of the power supply must be
interference does not occur, such as by configuring series grounded so that output should not turn ON due to grounding of
connections or using physical barriers between adjacent sets. the output line.
[For NPN output]
F3SJ-E F3SJ-B F3SJ-A Do not short-circuit an output line to 0 V line. Otherwise, the
Make sure that the F3SJ is securely mounted and its cables and output is always ON. Also, +24 V of the power supply must be
connectors are properly secured. grounded so that output should not turn ON due to grounding of
the output line.
F3SJ-E F3SJ-B F3SJ-A
Make sure that no foreign material, such as water, oil or dust, F3SJ-E F3SJ-B F3SJ-A
enters the inside of the F3SJ while the cap is removed. Configure the system by using the optimal number of safety
outputs that satisfy the requirements of the necessary safety
category.
101
F3SJ-E/F3SJ-B/F3SJ-A
102
F3SJ-E/F3SJ-B/F3SJ-A
Safety Distance F3SJ-E F3SJ-B F3SJ-A If the result exceeds 500 mm, use the following formula where
The safety distance is the distance that must be set between the F3SJ K = 1,600 mm/s.
and a machine's hazardous part to stop the hazardous part before a S = 1,600 mm/s x (Tm + Ts) + 8 x (d - 14 mm) . . . Formula (3)
person or object reaches it. The safety distance varies according to
If the result of this Eq. (3) is less than 500 mm,
the standards of each country and the individual specifications of
S = 500 mm
each machine. In addition, the calculation of the safety distance
differs if the direction of approach is not vertical to the detection zone System that has a detection capability larger than 40 mm
of the F3SJ. Always refer to relevant standards. Use K = 1,600 mm/s and C = 8 x (d - 850 mm) in equation (1) for
Safety distance (S)
the calculation.
S = 1,600 mm/s x (Tm + Ts) + 850 x (d - 14 mm) ... Formula (4)
• S = Safety distance (mm)
• Tm = Machine's response time (s)
• Ts = Response time of the F3SJ from ON to OFF (s)
Hazard
[Calculation example]
When Tm = 0.05 s, Ts = 0.01 s:
S = 1,600 mm/s x (0.05 s + 0.01 s) + 850 mm
= 946 mm
[Calculation example]
System that has detection capability of 40 mm max.
When K = 1,600 mm/s, Ts + Tc = 0.06 s, brake monitor setting time
Use K = 2,000 mm/s and C = 8 x (d - 14 mm) in equation (1) for the
= 0.1 s, Tr = 0.01 s, and d = 14 mm:
calculation.
Tbm = 0.1 - 0.06 = 0.04 s
S = 2,000 mm/s x (Tm + Ts) + 8 x (d - 14 mm)
Dpf = 3.4 x (14 - 7.0) = 23.8 mm
• S = Safety distance (mm)
S = 1,600 mm/s x (0.06 s + 0.01 s + 0.04 s) + 23.8 mm = 199.8 mm
• Tm = Machine's response time (s)
• Ts = Response time of the F3SJ from ON to OFF (s)
• d = Size of F3SJ's detection capability (mm)
[Calculation example]
When Tm = 0.05 s, Ts = 0.01 s, and d = 14 mm:
S = 2,000 mm/s x (0.05 s + 0.01 s) + 8 x (14 mm - 14 mm)
= 120 mm . . . Eq. (2)
If the result is less than 100 mm, use S = 100 mm.
103
F3SJ-E/F3SJ-B/F3SJ-A
Distance from Reflective Surface F3SJ-E F3SJ-B F3SJ-A Mutual Interference Prevention F3SJ-E F3SJ-B F3SJ-A
WARNING WARNING
Install the sensor system so that it is not affected by reflection Do not use the sensor system with mirrors in a regressive
from a reflective surface. Failure to do so may hinder detection, reflective configuration. Doing so may hinder detection. It is
resulting in serious injury. possible to use mirrors to "bend" the detection zone to a 90-
degree angle.
Install the sensor system at distance D or further from highly
reflective surfaces such as metallic walls, floors, ceilings, or When using more than 1 set of F3SJ, install them so that mutual
workpieces, as shown below. interference does not occur, such as by configuring series
connections or using physical barriers between adjacent sets.
Reflective ceiling
Mutual interference from other F3SJ is prevented in up to 3 sets
without series connection.
D For series connection F3SJ-B F3SJ-A
Emitter Receiver
Series connection can prevent mutual interference when multiple
sensors are used. Up to 3 sets with 192 beam for F3SJ-B series, or
up to 4 sets with 400 beams for F3SJ-A series can be series-
Detection zone
connected. Emission of series-connected F3SJ is time-divided,
L ensuring safety without occurring mutual interference.
Emitter 1 Receiver 1
D
Reflective floor
Emitter 2 Receiver 2
Reflective surface
104
F3SJ-E/F3SJ-B/F3SJ-A
Emitter 1 Receiver 1
Emitter 2 Receiver 2
Emitter Receiver
Emitter Receiver
3. Keep sufficient distance between the F3SJs so that mutual Interference light
Emitter Receiver
5°
D D
Emitter Receiver
Emitter Receiver 5°
105
F3SJ-E/F3SJ-B/F3SJ-A
Related Manuals
Man. No. Model Manual name
SCHG-718 F3SJ-A@@@@P@@ F3SJ-A@@@@P@@ (Ver.2) Safety Light Curtain User's Manual
SCHG-720 F3SJ-A@@@@P@@-TS F3SJ-A@@@@P@@-TS Safety Light Curtain User's Manual
SCHG-722 F3SJ-A@@@@P20-01TS F3SJ-A@@@@P20-01TS Safety Light Curtain User's Manual
SCHG-719 F3SJ-A@@@@N@@ F3SJ-A@@@@N@@(Ver.2) Safety Light Curtain User's Manual
SCHG-726 F3SJ-A@@@@N@@-01T F3SJ-A@@@@N@@-01T(Ver.2) Safety Light Curtain User's Manual
SCHG-716 F3SJ-AM@P@@@ F3SJ-AM@P@@@(Ver.2) Multi-beam Safety Sensor User's Manual
SCHG-734 F3SJ-B@@@@P25-01TS F3SJ-B@@@@P25-01TS Safety Light Curtain User's Manual
SCHG-733 F3SJ-E@@@@N25/B@@@@N25 F3SJ-E@@@@N25/B@@@@N25 Safety Light Curtain User's Manual
SCHG-732 F3SJ-E@@@@P25/B@@@@P25 F3SJ-E@@@@P25/B@@@@P25 Safety Light Curtain User's Manual
SCHG-712 F39-MC21 F39-MC21 F39-MC21 Setting Console Instruction Sheet
SCHG-736 F3SJ-B@@@@P25-02TS F3SJ-B@@@@P25-02TS Safety Light Curtain User's Manual
106
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
CSM_25_1_0315