(A) OBSERVATIONS OF SOIL PROPERTIES -:

FOLLOWING VALUES OF SOIL PARAMETERS HAVE BEEN


CONSIDERED IN DESIGN:
NOTES -: (THESE PROPERTIES SHALL BE VERIFIED AT SITE )

1. THE REINFORCED FILL SHALL HAVE THE MINIMUM


FOLLOWING PROPERTIES:
30.0
DENSITY OF SOIL (Y) :
COHESION (C) : 0

2. DENSITY OF INFILL MATERIAL SHALL BE FULLY


COMPACTED.

NOTES:
1. ALL DIMENSIONS ARE IN MM UNTILL UNLESS NOTIFIED.
CROSS - SECTION OF 3 M HIGH GABION
FASCIA WALL ( 2M ABOVE GROUND LEVEL)

CROSS - SECTION OF 4 M HIGH GABION CROSS - SECTION OF 5 M HIGH GABION


FASCIA WALL ( 3 M ABOVE GROUND LEVEL) FASCIA WALL ( 4 M ABOVE GROUND LEVEL)

REV. DESCRIPTION DRAWN CHECKED DESIGN SH. NO. DATE CLIENT EPC CONTRACTOR- AUTHORITY ENGINEER- GABION WALL DESIGN BY: PROJECT: STAMP & SIGNATURE
01 REVISED AS PER SITE CONDTION A.G R.V V.S 01.07.2020 Pkg-3 Four Laning of Washim to Pangare from Km 92.200 to
TERRAIN INFRATECH Km. 134.500 of NH-161 including Bypasses at Kanergaon
and Hingoli in the state of Maharashtra on EPC mode
Office No. 443- 444, 4th Floor
DRAWING TITLE: CROSS SECTION GABION WALL 3.0 M TO 5.0 M
B-24,Gokul Vatika,Jawahar Circle Vipul Trade Center, Sec-48
Jaipur-302018, Rajasthan, INDIA Sohna Road, Gurugram(122001)HARYANA SHEET NO. - 02/02 DATE : 26.06.2020