NOTES:-

1. ALL DIMENSIONS ARE IN MILLIME TERS UNLESS OTHERWISE


SPECIFIED.
2. FIGURED DIMENSIONS SHALL BE F OLLOWED. ALL DIMENSIONS
SHALL BE CHECKED AND VERIFIED BE FORE COMMENCEMENT OF
THE WORK.
3. CLEAR COVER TO MAIN REINF. SH ALL
BE:- a) FOR BEAMS 25mm b) FOR SLAB 20mm.
c)FDN 50mm d) COL. 40mm.
X46 X47 X48
4. CONCRETE MIX SHALL BE M-25.
5. CEMENT MORTAR SHALL BE 1:6 F OR 230 TH BRICK WORK AND 1:4
115TH BRICK WORK.
6. BRICKS OF CLASS DESIGNATION 75 HAVING MINIMUM CRUSHING
X49 STRENGTH OF 75 kg/Cm 2 SHALL BE USED.
X50 X51 7. REINF. SHALL BE :- a) HIGH S TRENGTH DEFORMED STEEL BARS OF
GRADE Fe 500 CONFORMING TO IS: 1 786- 1985 (CHAR. STRENGTH 500
N/mm2 ) OR
ALL STEEL REINF. SHALL BE H IGH STRENGTH DEFORMED BARS CTD/
TMT CONFIRMING TO I.S. 1786 AND HAVING A YIELD STRENGTH OF
500 N/mm 2.
8. IN PORTION MARKED 'Z' (SHOWN IN TYP. SECTION THROUGH COL.)

300
OF THE COL. SAME LINK SHALL BE PROVIDED FOR ZONE 'h1' IN
CASE OF EXTERNAL COL. & FOR ZONE 'h2' IN CASE OF INTERNAL
COLUMN, FACILITATE IS PLACING TH ESE LINKS MAY BE PROVIDED
'U' SHAPED.
9.
10.
300 11. THIS BUILDING IS DESIGNED FO R G+4 STOREY ONLY. AAC BLOCK
WILL BE USED AS IN FILL WALL MAS ONRY
12. THIS IS GFC DRAWING SUBJECTE D TO THE APPROVAL BY THE
CLIENT.
13.ALL ELECTRICAL AND PHE SHAFTS WILL BE AS PER ARCHITECTURAL
DRAWINGS.
B12A 14. PART OF DOME DRAWING IS SUBJ ECT TO APPROVAL/CONSENT FROM
THE CLIENT.
B3A

As per Architecture drawing


BK2
Y4
1149 250
BK1
1157
450

3136 BK1
1115 2686
450

1119 Y3

400
275
RB1
B6A

B6A

B5

600
Y2
450
PART PLAN GRID X47 -X 50
As per Architecture drawing
As per Architecture drawing
TOP OF DOME

100
10Ø @150 C/C

As per Architecture drawing


75
75

300
600

225
10Ø @150
450 300
C/C
10Ø @150 C/C

As per Architecture drawing


N. B. C. C.
I.S.O 9001
110 NBCC
CONSULTANCY DIVISION
250
Ring beam
as per Detail
275

250 Column as
per Detail
275

You might also like