You are on page 1of 8

GENERAL NOTES

1- ALL UNITS ARE IN INCHES EXCEPT


MENTIONED.
2- STEEL REBARS SHOULD CONFIRM TO MIN
YIELD STRENGTH OF 60 KSI
3- CONCRETE FOR BEAMS AND SLAB SHOULD
HAVE fc' OF 3000 PSI (28 DAYS CYLINDRICAL)
4- FOOTINGS, COLUMNS AND SHEAR WALLS
SHOULD CONFIRM TO MIN DESIGN
COMPRESSIVE STRENGTH OF 4000 PSI
(CYLINDRICAL)
5- DRAWING BE READ w.r.t NO'S MENTIONED AT
THE FOOTER OF EACH PLAN / DETAILED.
6- EXTERNAL WALLS HAVE BEEN DESIGNED
FOR 8" SOLID BLOCKS AND INTERNAL WALLS
BE CONSTRUCTED WITH 6" HOLLOW
CONCRETE BLOCKS.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 7- FOOTING DESIGN HAS BEEN CARRIED OUT
FOR 0.75 TSF BEARING CAPACITY AS
18'-0" 17'-3" 1"
12'-12 5'-6" 3'-3" 14'-4" 17'-2" 12'-9" 4'-9" 4'-0" 1"
13'-72 17'-3" 18'-0" RECOMMENDED IN REPORT FOR RAFT.
8- STAIRCASE BE COVERED WITH FIBER GLASS
SHED AT THE TOP AS PER MANUFACTURER
SPECS.

A 9- THERE IS NO WATER TANK AT ROOF TOP SO


CARE MUST BE EXERCISED ACCORDINGLY

11- HEAVY LAB EQUIPMENT BE ONLY INSTALLED


AT GROUND FLOOR.

#3@6"c/c #3@6"c/c
24'-6"

#3@6"c/c
#3@6"c/c

S1 S1 S1 S1 S1 S1 S1 S1 S1

9'-0"
B
#3@8"c/c
#3@8"c/c

S1 S1 S1 S1 S1 S1 S1 S1 S1
24'-6"

S2 S2
#3@6"c/c

#3@6"c/c

#3@8"c/c
#3@8"c/c

C PARTNERS IN DEVELOPMENT
#3@8"c/c #3@8"c/c (PID) CONSULTING
Stair Reinf. ENGINEERS
ISLAMABAD
9'-0"

\\Server-pc\d\E DRIVE DATA\BAHRIA TOWN EDC COMMERCIAL\VETTING PROJECTS\OTHERS\2-ARSLAN MUSHTAQ\STRUCTURE\PID.jpg

S3 S3 S3 S3
D1 S3 S3 S3
Stair Reinf.
D
CLIENT:

NATIONAL UNIVERSITY OF TECHNOLOGY


PROJECT:
DESIGN & CONST OF 4 X STOREY BLOCK
AT NATIONAL UNIVERSITY OF
TECHNOLOGY, IJP ROAD, ISLAMABAD
BOTTOM BAR REINFORCEMENT PLAN (FF SLAB - 1ST FLOOR)
(SLAB THICKNESS-6")
DOCUMENT TITLE

SLAB REINFORCEMENT PLAN


AT FIRST FLOOR
(BOTTOM BARS)

DRAWING NO. STAMP & SIGN


N/STR/16/ 23
DESIGN BY.
ENGR. ARSLAN MUSHTAQ
REVIEWED BY.
ENGR. ANSAR IQBAL
CAD BY.
MUHAMMAD ASHRAF TAHIR
DATE:
06-12-2020
GENERAL NOTES

1- ALL UNITS ARE IN INCHES EXCEPT


MENTIONED.
2- STEEL REBARS SHOULD CONFIRM TO MIN
YIELD STRENGTH OF 60 KSI
3- CONCRETE FOR BEAMS AND SLAB SHOULD
HAVE fc' OF 3000 PSI (28 DAYS CYLINDRICAL)
4- FOOTINGS, COLUMNS AND SHEAR WALLS
SHOULD CONFIRM TO MIN DESIGN
COMPRESSIVE STRENGTH OF 4000 PSI
(CYLINDRICAL)
5- DRAWING BE READ w.r.t NO'S MENTIONED AT
THE FOOTER OF EACH PLAN / DETAILED.
6- EXTERNAL WALLS HAVE BEEN DESIGNED
FOR 8" SOLID BLOCKS AND INTERNAL WALLS
BE CONSTRUCTED WITH 6" HOLLOW
1 2 3 4 5 6 7 8 9 10 11 12 13 14 CONCRETE BLOCKS.
7- FOOTING DESIGN HAS BEEN CARRIED OUT
18'-0" 17'-3" 1"
12'-12 5'-6" 3'-3" 14'-4" 17'-2" 12'-9" 4'-9" 4'-0" 1"
13'-72 17'-3" 18'-0" FOR 0.75 TSF BEARING CAPACITY AS
RECOMMENDED IN REPORT FOR RAFT.
8- STAIRCASE BE COVERED WITH FIBER GLASS
SHED AT THE TOP AS PER MANUFACTURER
SPECS.
A
9- THERE IS NO WATER TANK AT ROOF TOP SO
CARE MUST BE EXERCISED ACCORDINGLY
L/3
L/4

#4@6"c/c 11- HEAVY LAB EQUIPMENT BE ONLY INSTALLED


AT GROUND FLOOR.

L/3

L/3

L/3

L/3

L/3

L/3
L/4

L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3
L/3
24'-6"

#4@5"c/c
#4@5"c/c

#4@5"c/c
#4@5"c/c

#4@5"c/c

#4@5"c/c
#3@6"c/c

#4@5"c/c

#4@5"c/c

#4@5"c/c
L/3
L/3
L/3

#4@8"c/c

B
L/3
L/3

L/3

L/3
L/3 L/3
L/3 L/3
L/4
L/3 L/3 L/3 L/3
L/3 L/3 L/3 L/3
L/3 L/3
24'-6"

L/3
#4@5"c/c

#4@5"c/c

#4@5"c/c

#4@5"c/c
L/3 L/3
L/3

L/3

L/3

L/4
L/4

L/4

#4@8"c/c

C L/3
PARTNERS IN DEVELOPMENT
L/4
Stair Reinf.
6'-3"

(PID) CONSULTING
ENGINEERS
\\Server-pc\d\E DRIVE DATA\BAHRIA TOWN EDC COMMERCIAL\VETTING PROJECTS\OTHERS\2-ARSLAN MUSHTAQ\STRUCTURE\PID.jpg

ISLAMABAD
L/3
D1
2'-9"

Stair Reinf.
D
CLIENT:

NATIONAL UNIVERSITY OF TECHNOLOGY


PROJECT:
DESIGN & CONST OF 4 X STOREY BLOCK
TOP BAR REINFORCEMENT PLAN (FF SLAB - 1ST FLOOR) AT NATIONAL UNIVERSITY OF
TECHNOLOGY, IJP ROAD, ISLAMABAD
(SLAB THICKNESS-6")

DOCUMENT TITLE

SLAB REINFORCEMENT PLAN


AT FIRST FLOOR
(TOP BARS)

DRAWING NO. STAMP & SIGN


N/STR/17/ 23
DESIGN BY.
ENGR. ARSLAN MUSHTAQ
REVIEWED BY.
ENGR. ANSAR IQBAL
CAD BY.
MUHAMMAD ASHRAF TAHIR
DATE:
06-12-2020
(SLAB THICKNESS-6")

GENERAL NOTES

1- ALL UNITS ARE IN INCHES EXCEPT


MENTIONED.
2- STEEL REBARS SHOULD CONFIRM TO MIN
YIELD STRENGTH OF 60 KSI
3- CONCRETE FOR BEAMS AND SLAB SHOULD
HAVE fc' OF 3000 PSI (28 DAYS CYLINDRICAL)
4- FOOTINGS, COLUMNS AND SHEAR WALLS
SHOULD CONFIRM TO MIN DESIGN
COMPRESSIVE STRENGTH OF 4000 PSI
(CYLINDRICAL)
5- DRAWING BE READ w.r.t NO'S MENTIONED AT
THE FOOTER OF EACH PLAN / DETAILED.
6- EXTERNAL WALLS HAVE BEEN DESIGNED
FOR 8" SOLID BLOCKS AND INTERNAL WALLS
BE CONSTRUCTED WITH 6" HOLLOW
1 2 3 4 5 6 7 8 9 10 11 12 13 14 CONCRETE BLOCKS.
7- FOOTING DESIGN HAS BEEN CARRIED OUT
158'-0" FOR 0.75 TSF BEARING CAPACITY AS
RECOMMENDED IN REPORT FOR RAFT.
18'-0" 17'-3" 1"
12'-12 5'-6" 3'-3" 14'-4" 17'-2" 12'-9" 4'-9" 4'-0" 1"
13'-72 17'-3" 18'-0" 8- STAIRCASE BE COVERED WITH FIBER GLASS
SHED AT THE TOP AS PER MANUFACTURER
SPECS.
A
1'-0"

1'-4"

1'-4"

1'-4"

1'-0"
9- THERE IS NO WATER TANK AT ROOF TOP SO
CARE MUST BE EXERCISED ACCORDINGLY

11- HEAVY LAB EQUIPMENT BE ONLY INSTALLED

#3@6"c/c #3@6"c/c AT GROUND FLOOR.

X X
24'-6"

#3@6"c/c
#3@6"c/c

S1 S1 S1 S1 S1 S1 S1 S1 S1
9"
49'-0"

1'-4"
B
#3@8"c/c
#3@8"c/c

9"

S1 S1 S1 S1 S1 S1 S1 S1 S1 X X
24'-6"

S2 S2
#3@6"c/c

#3@6"c/c

#3@8"c/c
#3@8"c/c

C SILL LEVEL SHADE SILL LEVEL SHADE


#3@8"c/c #3@8"c/c
Stair Reinf. PARTNERS IN DEVELOPMENT
(PID) CONSULTING
9'-0"

S3 S3 S3 S3 ENGINEERS
ISLAMABAD
S3 S3
\\Server-pc\d\E DRIVE DATA\BAHRIA TOWN EDC COMMERCIAL\VETTING PROJECTS\OTHERS\2-ARSLAN MUSHTAQ\STRUCTURE\PID.jpg

S3
Stair Reinf.
D

CLIENT:

REFER TO 15" NATIONAL UNIVERSITY OF TECHNOLOGY


PROJECT:
SLAB DETAIL DESIGN & CONST OF 4 X STOREY BLOCK

3"
AT NATIONAL UNIVERSITY OF
BOTTOM BAR REINFORCEMENT PLAN (SF SLAB - 2ND FLOOR) TECHNOLOGY, IJP ROAD, ISLAMABAD

6"
(SLAB THICKNESS-6") REFER TO
RELEVANT BEAM

2'-0"
DETAIL DOCUMENT TITLE

15"
9" SLAB REINFORCEMENT PLAN
AT SECOND FLOOR

6"
(BOTTOM BARS)

DRAWING NO. STAMP & SIGN


N/STR/18/ 23
2#3 DESIGN BY.
#4@8"c/c ENGR. ARSLAN MUSHTAQ
REVIEWED BY.
ENGR. ANSAR IQBAL

SEC AT X-X CAD BY.


MUHAMMAD ASHRAF TAHIR
DATE:
06-12-2020
GENERAL NOTES

1- ALL UNITS ARE IN INCHES EXCEPT


MENTIONED.
2- STEEL REBARS SHOULD CONFIRM TO MIN
YIELD STRENGTH OF 60 KSI
3- CONCRETE FOR BEAMS AND SLAB SHOULD
HAVE fc' OF 3000 PSI (28 DAYS CYLINDRICAL)
4- FOOTINGS, COLUMNS AND SHEAR WALLS
SHOULD CONFIRM TO MIN DESIGN
COMPRESSIVE STRENGTH OF 4000 PSI
(CYLINDRICAL)
5- DRAWING BE READ w.r.t NO'S MENTIONED AT
THE FOOTER OF EACH PLAN / DETAILED.
6- EXTERNAL WALLS HAVE BEEN DESIGNED
1 2 3 4 5 6 7 8 9 10 11 12 13 14 FOR 8" SOLID BLOCKS AND INTERNAL WALLS
BE CONSTRUCTED WITH 6" HOLLOW
CONCRETE BLOCKS.
158'-0" 7- FOOTING DESIGN HAS BEEN CARRIED OUT
18'-0" 17'-3" 1"
12'-12 5'-6" 3'-3" 14'-4" 17'-2" 12'-9" 4'-9" 4'-0" 1"
13'-72 17'-3" 18'-0" FOR 0.75 TSF BEARING CAPACITY AS
RECOMMENDED IN REPORT FOR RAFT.
8- STAIRCASE BE COVERED WITH FIBER GLASS
A SHED AT THE TOP AS PER MANUFACTURER
SPECS.
L/3

9- THERE IS NO WATER TANK AT ROOF TOP SO


L/4

CARE MUST BE EXERCISED ACCORDINGLY


#4@6"c/c

L/3
L/4 11- HEAVY LAB EQUIPMENT BE ONLY INSTALLED
AT GROUND FLOOR.
L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3
L/3
24'-6"

#4@5"c/c
#4@5"c/c

#4@5"c/c
X X
#4@5"c/c

#4@5"c/c

#4@5"c/c
#3@6"c/c

#4@5"c/c

#4@5"c/c

#4@5"c/c
49'-0"

L/3

L/3
L/3
#4@8"c/c

B
L/3
L/3

L/3

L/3
L/3 L/3
L/3 L/3 X X
L/4

L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3


L/3 L/3
24'-6"

#4@5"c/c

#4@5"c/c

#4@5"c/c

#4@5"c/c
L/3 L/3
L/3

L/3

L/3

L/4
L/4

#4@8"c/c
L/4

C SILL LEVEL SHADE L/3 SILL LEVEL SHADE


L/4
Stair Reinf.
PARTNERS IN DEVELOPMENT
9'-0"

(PID) CONSULTING
L/3 ENGINEERS
Stair Reinf. \\Server-pc\d\E DRIVE DATA\BAHRIA TOWN EDC COMMERCIAL\VETTING PROJECTS\OTHERS\2-ARSLAN MUSHTAQ\STRUCTURE\PID.jpg

ISLAMABAD

CLIENT:

NATIONAL UNIVERSITY OF TECHNOLOGY

TOP BAR REINFORCEMENT PLAN (SF SLAB - 2ND FLOOR) PROJECT:


DESIGN & CONST OF 4 X STOREY BLOCK
(SLAB THICKNESS-6") AT NATIONAL UNIVERSITY OF
TECHNOLOGY, IJP ROAD, ISLAMABAD

DOCUMENT TITLE

SLAB REINFORCEMENT PLAN


AT SECOND FLOOR
(TOP BARS)

DRAWING NO. STAMP & SIGN


N/STR/19/ 23
DESIGN BY.
ENGR. ARSLAN MUSHTAQ
REVIEWED BY.
ENGR. ANSAR IQBAL
CAD BY.
MUHAMMAD ASHRAF TAHIR
DATE:
06-12-2020
GENERAL NOTES

1- ALL UNITS ARE IN INCHES EXCEPT


MENTIONED.
2- STEEL REBARS SHOULD CONFIRM TO MIN
YIELD STRENGTH OF 60 KSI
3- CONCRETE FOR BEAMS AND SLAB SHOULD
HAVE fc' OF 3000 PSI (28 DAYS CYLINDRICAL)
4- FOOTINGS, COLUMNS AND SHEAR WALLS
SHOULD CONFIRM TO MIN DESIGN
COMPRESSIVE STRENGTH OF 4000 PSI
(CYLINDRICAL)
5- DRAWING BE READ w.r.t NO'S MENTIONED AT
THE FOOTER OF EACH PLAN / DETAILED.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 6- EXTERNAL WALLS HAVE BEEN DESIGNED
FOR 8" SOLID BLOCKS AND INTERNAL WALLS
158'-0" BE CONSTRUCTED WITH 6" HOLLOW
CONCRETE BLOCKS.
18'-0" 17'-3" 1"
12'-12 5'-6" 3'-3" 14'-4" 17'-2" 12'-9" 4'-9" 4'-0" 1"
13'-72 17'-3" 18'-0" 7- FOOTING DESIGN HAS BEEN CARRIED OUT
FOR 0.75 TSF BEARING CAPACITY AS
RECOMMENDED IN REPORT FOR RAFT.
A 8- STAIRCASE BE COVERED WITH FIBER GLASS
1'-0"

1'-4"

1'-4"

1'-4"

1'-0"
SHED AT THE TOP AS PER MANUFACTURER
SPECS.
9- THERE IS NO WATER TANK AT ROOF TOP SO
#3@6"c/c #3@6"c/c CARE MUST BE EXERCISED ACCORDINGLY

11- HEAVY LAB EQUIPMENT BE ONLY INSTALLED


AT GROUND FLOOR.

X X
24'-6"

#3@6"c/c
#3@6"c/c

S1 S1 S1 S1 S1 S1 S1 S1 S1
9"
49'-0"

1'-4"
B
#3@8"c/c
#3@8"c/c

9"

S1 S1 S1 S1 S1 S1 S1 S1 S1 X X
24'-6"

S2 S2
#3@6"c/c

#3@6"c/c

#3@8"c/c
#3@8"c/c

C
#3@8"c/c #3@8"c/c
Stair Reinf.
9'-0"

S3 S3 S3 S3
PARTNERS IN DEVELOPMENT
S3 S3 S3 (PID) CONSULTING
Stair Reinf. ENGINEERS
D ISLAMABAD
\\Server-pc\d\E DRIVE DATA\BAHRIA TOWN EDC COMMERCIAL\VETTING PROJECTS\OTHERS\2-ARSLAN MUSHTAQ\STRUCTURE\PID.jpg

CLIENT:

BOTTOM BAR REINFORCEMENT PLAN (TF SLAB - 3RD FLOOR) REFER TO 15" NATIONAL UNIVERSITY OF TECHNOLOGY
PROJECT:
(SLAB THICKNESS-6") SLAB DETAIL DESIGN & CONST OF 4 X STOREY BLOCK

3"
AT NATIONAL UNIVERSITY OF
TECHNOLOGY, IJP ROAD, ISLAMABAD

6"
REFER TO
RELEVANT BEAM
DOCUMENT TITLE

2'-0"
DETAIL

15"
9" SLAB REINFORCEMENT PLAN
AT THIRD FLOOR
(BOTTOM BARS)

6"
DRAWING NO. STAMP & SIGN
N/STR/20/ 23

2#3 DESIGN BY.


ENGR. ARSLAN MUSHTAQ
#4@8"c/c REVIEWED BY.
ENGR. ANSAR IQBAL
CAD BY.
SEC AT X-X MUHAMMAD ASHRAF TAHIR
DATE:
06-12-2020
GENERAL NOTES

1- ALL UNITS ARE IN INCHES EXCEPT


MENTIONED.
2- STEEL REBARS SHOULD CONFIRM TO MIN
YIELD STRENGTH OF 60 KSI
3- CONCRETE FOR BEAMS AND SLAB SHOULD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 HAVE fc' OF 3000 PSI (28 DAYS CYLINDRICAL)
4- FOOTINGS, COLUMNS AND SHEAR WALLS
158'-0" SHOULD CONFIRM TO MIN DESIGN
COMPRESSIVE STRENGTH OF 4000 PSI
18'-0" 17'-3" 1"
12'-12 5'-6" 3'-3" 14'-4" 17'-2" 12'-9" 4'-9" 4'-0" 1"
13'-72 17'-3" 18'-0" (CYLINDRICAL)
5- DRAWING BE READ w.r.t NO'S MENTIONED AT
THE FOOTER OF EACH PLAN / DETAILED.
A 6- EXTERNAL WALLS HAVE BEEN DESIGNED
FOR 8" SOLID BLOCKS AND INTERNAL WALLS

L/3
BE CONSTRUCTED WITH 6" HOLLOW
L/4

CONCRETE BLOCKS.
#4@6"c/c
7- FOOTING DESIGN HAS BEEN CARRIED OUT

L/3

L/3

L/3

L/4
L/4 FOR 0.75 TSF BEARING CAPACITY AS
RECOMMENDED IN REPORT FOR RAFT.
L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 8- STAIRCASE BE COVERED WITH FIBER GLASS
L/3 SHED AT THE TOP AS PER MANUFACTURER
SPECS.
24'-6"

9- THERE IS NO WATER TANK AT ROOF TOP SO

#4@5"c/c
#4@5"c/c
#4@5"c/c

#4@5"c/c
CARE MUST BE EXERCISED ACCORDINGLY

#4@5"c/c

#4@5"c/c

#4@5"c/c
#3@6"c/c

#4@5"c/c
X X

#4@5"c/c
11- HEAVY LAB EQUIPMENT BE ONLY INSTALLED
AT GROUND FLOOR.
49'-0"

#4@8"c/c
L/3

L/3
L/3
B
L/3
L/3

L/3

L/3
L/3 L/3
L/3 L/3

L/4 L/3 L/3 L/3 L/3


L/3 L/3 X X
L/3 L/3 L/3 L/3 L/3 L/3
24'-6"

#4@5"c/c

#4@5"c/c

#4@5"c/c

#4@5"c/c
L/3

L/3

L/3
L/4

L/4
L/4

#4@8"c/c

C L/3
Stair Reinf. L/4
9'-0"

L/3
Stair Reinf.
D

PARTNERS IN DEVELOPMENT
(PID) CONSULTING
ENGINEERS
\\Server-pc\d\E DRIVE DATA\BAHRIA TOWN EDC COMMERCIAL\VETTING PROJECTS\OTHERS\2-ARSLAN MUSHTAQ\STRUCTURE\PID.jpg

ISLAMABAD
TOP BAR REINFORCEMENT PLAN (TF SLAB - 3RD FLOOR)
(SLAB THICKNESS-6")

CLIENT:

NATIONAL UNIVERSITY OF TECHNOLOGY


PROJECT:
DESIGN & CONST OF 4 X STOREY BLOCK
AT NATIONAL UNIVERSITY OF
TECHNOLOGY, IJP ROAD, ISLAMABAD

DOCUMENT TITLE

SLAB REINFORCEMENT PLAN


AT THIRD FLOOR
(TOP BARS)

DRAWING NO. STAMP & SIGN


N/STR/21/ 23
DESIGN BY.
ENGR. ARSLAN MUSHTAQ
REVIEWED BY.
ENGR. ANSAR IQBAL
CAD BY.
MUHAMMAD ASHRAF TAHIR
DATE:
06-12-2020
GENERAL NOTES

1- ALL UNITS ARE IN INCHES EXCEPT


MENTIONED.
2- STEEL REBARS SHOULD CONFIRM TO MIN
YIELD STRENGTH OF 60 KSI
3- CONCRETE FOR BEAMS AND SLAB SHOULD
HAVE fc' OF 3000 PSI (28 DAYS CYLINDRICAL)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 4- FOOTINGS, COLUMNS AND SHEAR WALLS
SHOULD CONFIRM TO MIN DESIGN
COMPRESSIVE STRENGTH OF 4000 PSI
158'-0" (CYLINDRICAL)
X

1'-4"
1" 1"
18'-0" X 17'-3" 12'-12 5'-6" 3'-3" 14'-4" 17'-2" 12'-9" 4'-9" 4'-0" 13'-72 17'-3" 18'-0" 5- DRAWING BE READ w.r.t NO'S MENTIONED AT
THE FOOTER OF EACH PLAN / DETAILED.
6- EXTERNAL WALLS HAVE BEEN DESIGNED
A FOR 8" SOLID BLOCKS AND INTERNAL WALLS

1'-0"

1'-4"

1'-4"

1'-0"
BE CONSTRUCTED WITH 6" HOLLOW
X
X CONCRETE BLOCKS.
7- FOOTING DESIGN HAS BEEN CARRIED OUT
#3@6"c/c FOR 0.75 TSF BEARING CAPACITY AS
#3@6"c/c RECOMMENDED IN REPORT FOR RAFT.
8- STAIRCASE BE COVERED WITH FIBER GLASS
SHED AT THE TOP AS PER MANUFACTURER
SPECS.
9- THERE IS NO WATER TANK AT ROOF TOP SO
24'-6"

CARE MUST BE EXERCISED ACCORDINGLY

#3@6"c/c
#3@6"c/c

S1 S1 S1 S1 S1 S1 S1 S1 S1 11- HEAVY LAB EQUIPMENT BE ONLY INSTALLED


9" AT GROUND FLOOR.
49'-0"

X X

1'-4"
B
#3@8"c/c
#3@8"c/c

9"

S1 S1 S1 S1 S1 S1 S1 S1 S1 X X
24'-6"

S2 S2
#3@6"c/c

#3@6"c/c

#3@8"c/c
#3@8"c/c

Y Y

C
#3@8"c/c #3@8"c/c
Stair Reinf.

1'-6"
Y Y
9'-0"

S3 S3 S3 S3
S3 S3 S3
Stair Reinf.
D
PARTNERS IN DEVELOPMENT
6" (PID) CONSULTING
ENGINEERS
\\Server-pc\d\E DRIVE DATA\BAHRIA TOWN EDC COMMERCIAL\VETTING PROJECTS\OTHERS\2-ARSLAN MUSHTAQ\STRUCTURE\PID.jpg

ISLAMABAD

17'-4"
BOTTOM BAR REINFORCEMENT PLAN (ROOF SLAB )
(SLAB THICKNESS-6") 3#3
6" Thick.R.c.c Perapit CLIENT:

As Per Slab Steel

3'-3"
NATIONAL UNIVERSITY OF TECHNOLOGY
REFER TO PROJECT:
REFER TO
SLAB DETAIL
#3@9"c/c

DESIGN & CONST OF 4 X STOREY BLOCK


SLAB DETAIL 12" AT NATIONAL UNIVERSITY OF
TECHNOLOGY, IJP ROAD, ISLAMABAD
9'-4"

6"
#3@8"c/c
6"

DOCUMENT TITLE

1'-9"
12"
3#3 SLAB REINFORCEMENT PLAN
9"
15"

AT ROOF/ MUMTY
(BOTTOM BARS)
6"
REFER TO 12" DRAWING NO. STAMP & SIGN
RELEVANT BEAM N/STR/22/ 23

REFER TO
#4@8"c/c 2#3 DETAIL 4" DESIGN BY.

BOTTOM BAR REINFORCEMENT PLAN (MUMTY SLAB) RELEVANT BEAM


ENGR. ARSLAN MUSHTAQ
REVIEWED BY.
ENGR. ANSAR IQBAL
DETAIL
(SLAB THICKNESS-5") SEC AT X-X SEC AT Y-Y CAD BY.
MUHAMMAD ASHRAF TAHIR
DATE:
06-12-2020
GENERAL NOTES

1- ALL UNITS ARE IN INCHES EXCEPT


MENTIONED.
2- STEEL REBARS SHOULD CONFIRM TO MIN
YIELD STRENGTH OF 60 KSI
3- CONCRETE FOR BEAMS AND SLAB SHOULD
HAVE fc' OF 3000 PSI (28 DAYS CYLINDRICAL)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 4- FOOTINGS, COLUMNS AND SHEAR WALLS
SHOULD CONFIRM TO MIN DESIGN
COMPRESSIVE STRENGTH OF 4000 PSI
158'-0" (CYLINDRICAL)

1'-4"
18'-0" 17'-3" 1"
12'-12 5'-6" 3'-3" 14'-4" 17'-2" 12'-9" 4'-9" 4'-0" 1"
13'-72 17'-3" 18'-0" 5- DRAWING BE READ w.r.t NO'S MENTIONED AT
THE FOOTER OF EACH PLAN / DETAILED.
6- EXTERNAL WALLS HAVE BEEN DESIGNED
A FOR 8" SOLID BLOCKS AND INTERNAL WALLS

1'-0"

1'-4"

1'-4"

1'-0"
BE CONSTRUCTED WITH 6" HOLLOW
CONCRETE BLOCKS.

L/3
L/4

7- FOOTING DESIGN HAS BEEN CARRIED OUT


#4@6"c/c FOR 0.75 TSF BEARING CAPACITY AS

L/3

L/3

L/4
L/4 RECOMMENDED IN REPORT FOR RAFT.
8- STAIRCASE BE COVERED WITH FIBER GLASS
L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3 SHED AT THE TOP AS PER MANUFACTURER
SPECS.
L/3
9- THERE IS NO WATER TANK AT ROOF TOP SO
24'-6"

CARE MUST BE EXERCISED ACCORDINGLY

#4@5"c/c
#4@5"c/c
#4@5"c/c

#4@5"c/c
9"

#4@5"c/c

#4@5"c/c

#4@5"c/c
#3@6"c/c

#4@5"c/c

#4@5"c/c
11- HEAVY LAB EQUIPMENT BE ONLY INSTALLED
X X AT GROUND FLOOR.
49'-0"

L/3

L/3
L/3
#4@8"c/c
1'-4"
B
L/3
L/3

L/3

L/3
L/3 L/3
L/4 L/3 L/3
9"
X X
24'-6"

#4@5"c/c

#4@5"c/c

#4@5"c/c

#4@5"c/c
L/3

L/3

L/3

L/3
L/3

L/4

#4@8"c/c

C L/3
Stair Reinf. L/4
9'-0"

L/3
Stair Reinf.
D
PARTNERS IN DEVELOPMENT
(PID) CONSULTING
ENGINEERS
\\Server-pc\d\E DRIVE DATA\BAHRIA TOWN EDC COMMERCIAL\VETTING PROJECTS\OTHERS\2-ARSLAN MUSHTAQ\STRUCTURE\PID.jpg

ISLAMABAD

TOP BAR REINFORCEMENT PLAN (ROOF SLAB)


(SLAB THICKNESS-6")
17'-4"
CLIENT:

NATIONAL UNIVERSITY OF TECHNOLOGY


#3@8"c/c

#3@10"c/c
#3@10"c/c

PROJECT:
DESIGN & CONST OF 4 X STOREY BLOCK
AT NATIONAL UNIVERSITY OF
TECHNOLOGY, IJP ROAD, ISLAMABAD

9'-4"
DOCUMENT TITLE

SLAB REINFORCEMENT PLAN


AT ROOF / MUMTY
(TOP BARS)
#3@8"c/c
DRAWING NO. STAMP & SIGN
N/STR/23/ 23
DESIGN BY.
ENGR. ARSLAN MUSHTAQ
REVIEWED BY.
TOP BAR REINFORCEMENT PLAN (MUMTY SLAB) ENGR.
CAD BY.
ANSAR IQBAL

(SLAB THICKNESS-5") MUHAMMAD ASHRAF TAHIR


DATE:
06-12-2020

You might also like