KEMREX CAPACITY LOAD CALCULATION F1

Soil strength parameter


2
c= 10,000.00 kg/m 114 mm.
ϕ= - degree

Use KEMREX Model = F114x2000x220

1. Compression capacity Calculation

Qb=9SuAb

mm.
End bearing For Clay
2
When Su = 10,000.00 kg/m

2000
D= 0.114 m.
Ab = 𝜋𝐷2 = 0.01021 m2

Qb = 918.63 kg

Frictional resistance Shear area = 2πrh


when h= 1.600 m.
2
Shear area = 0.774 m
Su = c
Frictional resistance = 7,736.96 kg.

Ultimate Compression Force = Qb + Frictional resistance


= 8,656 kg.
F.S = 2.5
Safe load = 3,462.24 kg.

2. Uplift capacity calculation

2
Shear area = 0.774 m
Frictional resistance = 7,736.96 kg
Ultimate Uplift Force = Frictional resistance
= 7,737 kg.

KEMREX CO.,LTD
SUTEE Group Bldg, 3rd-4th FL. 27/5 Moo 7 Kingkaew - Thepharak Rd, Bang Phli Yai, Bang Phli, Samut Prakan, 10540
TEL +66 2 026-3140 FAX +66 2 715-0500 EMAIL: kemrex@kemrex.com WEB: www.kemrex.com