0050 X Welding Procedure Specifications (WPS) and Procedure PPer any of the following: BSI /ASME /JIS /DIN /EN.
Qualification Records (PQR)
0060 X Welder Qualification Records Per any of the following: BSI /ASME /JIS /DIN /EN.
0070 X NDT Personnel and Procedures Verify valid personnel qualification and procedure.
0020
0010
*** X
In process inspection & test requirement Specification Details / Notes:
Components or Devices in Classified Locations* that may produce Shall be listed or labeled by UL, FM, CSA or third parties
Arcs, Sparks or High Temperatures certified with the full requirements of CENELEC EN 50018.
0020 X Terminals and Junction boxes Verify terminal block type, connections & connectors, and
interconnections. Also, verify accessibility.
0040 X Workmanship, Components and Dimensions: Per 32-SAMSS-008. Where assembly requires bolting, all holes
a) All Bolts & Nuts in Clean Air Plenum are Welded shall be "pre-drilled".
IR325508 Continued...
INSPECTION & TESTING REQUIREMENTS REVISION: 04/30/2011 CODE NUMBER: PAGE:
SAUDI ARAMCO FORM-175 REPLACES: 12/29/2005 IR325508 2 of 3
(1) VISUAL INSPECTION WITNESSING BY INSPECTOR (Note 1)
(2) CERTIFICATES / RECORDS TO BE CHECKED BY INSPECTOR
(3) CERTIFICATES / DATA TO BE PROVIDED BY VENDOR / SUPPLIER / MANUFACTURER
0080 X Workmanship, Components and Dimensions: Per 32-SAMSS-008. Welding shall comply with welding code
e) Grating, Railing, Handrails, Ladders, and cages identified above. All welding shall be continuous.
0090 X Workmanship, Components and Dimensions: Exposed end cap; shall have part number and Month & Year of
f) Replacement Filter Element Markings Mfg. permanent markings on each element.
0120 X X NDT on Lifting Lugs All lifting lug connections shall be 100% radio-graphed,
ultrasonic testing shall be used in areas where radiography is
impractical.(see note 3).
0030
0010
*** X X
Final inspection & test requirements
Electrical Accessories, Pressure Switches
Specification Details / Notes:
Watertight per 32-SAMSS-008.
0020 X X Waterproof, Permanent Lighting System Watertight per NEMA 4 unless otherwise stated in the purchase
order.
0030 X X Pneumatic Instrumentation Leak test all pipe/tubing, functional test all instruments &
pneumatic control loops.
0040 X Electronic Timer/Sequencer Devices Watertight per 32-SAMSS-008 Shall be located to avoid radiant
and convicted heat.
0060 X Manual Switch Supplied to Initiate Pulse-Cleaning Shall be independent of the pressure switch settings.
0040
0010
***
X
Additional/Supplemental Requirements
Only when specified in the Purchase Order (PO):
Specification Details / Notes:
Notes:
(1) May only be waived by the responsible Saudi Aramco, ASC, and AOC Inspection Offices.
(2) See form SA175 - 000003 for instructions on using this form.
IR325508 Continued...
INSPECTION & TESTING REQUIREMENTS REVISION: 04/30/2011 CODE NUMBER: PAGE:
SAUDI ARAMCO FORM-175 REPLACES: 12/29/2005 IR325508 3 of 3
(1) VISUAL INSPECTION WITNESSING BY INSPECTOR (Note 1)
(2) CERTIFICATES / RECORDS TO BE CHECKED BY INSPECTOR
(3) CERTIFICATES / DATA TO BE PROVIDED BY VENDOR / SUPPLIER / MANUFACTURER
(3) LP test is acceptable in place of RT/UT if mass of the unit is less than 3000 Kg.
End of IR325508