Experiment 6
Multi Pump Test Rig
Positive Displacement Plunger Pump
Objectives
- Determine the operating characteristic of Positive Displacement Plunger
Pump in a contained unit.
- Understand the Positive Displacement Plunger Pump in principle and
design, and the selection of the appropriate pump for a particular
application for optimal operation.
Overview
Pumps are of a major concern to most engineers and technicians. The types of
pump vary considerably in principle and design, and the selection of the
appropriate pump for a particular application is essential for satisfactory
operation. This experiment allows students to measure the operating
characteristic of different pumps in a contained unit. This training unit
incorporates appropriate pipe work and tanks to make the operation self-
contained. The manually operated valves and pipe work are arranged for rapid
and safe selection of any one-test pump. All necessary instrumentation for
measurement of flow, pump head, speed and power are included. In the
experiments, students are able to operate three types of pump namely a
Horizontal Single Stage Centrifugal Pump, a Positive Displacement Plunger
Pump and a Positive Displacement Gear Pump.
1
Fluid Mechanics (CLD 10603)
Experiment 6: Positive Displacement Plunger Pump
1. Make sure that the water tank is filled with water up to at least 50%.
2. Make sure that the oil tank is filled with oil up to at least 50%.
3. Make sure that the RS 232 data cable is connected to the computer.
4. Switch on the main power supply located on the control panel. The
instruments should light up.
5. Select the appropriate pump and flow meter according to the following
combination.
6. Switch on the computer and monitor if you are using them to collect data
and generate the characteristic curve.
2
Fluid Mechanics (CLD 10603)
Experiment 6: Positive Displacement Plunger Pump
Important:
2. Ensure that the cable between the computer and the Pump Test Rig is
correctly connected.
4. Under Windows click on the Pump Test Rig icon. The program wills
startup automatically.
5. The table consists of fifteen entries and a final entry at the bottom labeled
'live'- this is the live reading at that moment in time (online data).
6. During an experiment, if you wish capture these data, click on the 'Record'
button.
8. These captured data could be saved in the form of a file. It could also be
loaded later for review or to add a new entry.
9. It is important that the user selects the correct pump before recording the
data, as live data will be represented differently for each pump.
3
Fluid Mechanics (CLD 10603)
Experiment 6: Positive Displacement Plunger Pump
Experimental Procedures
2. Adjust the potentiometer beside the speed indicator, set the motor speed
to its maximum (i.e. About 950 rpm)
3. Slowly adjust the HV2 so that the pump head (pressure) is at 90%.
4. Record the flow rate once the readings are stable.(Refer Table 3)
5. Repeat steps 2 and 4 for the following motor speed readings of P2 = 950,
900, 850, 800, 750, 700, 650, 600, 550 rpm.
6. The data you have collected will enable you to plot the following
characteristic curve.
Note:
i. Please turn off the pump by pressing the stop push button at the end
of experiment.
ii. Adjust the potentiometer to its minimum setting (fully anti clockwise).
Warning: Do not close the HV2 completely when P2 is running. This may cause
serious damage to the instrument.
4
Fluid Mechanics (CLD 10603)
Experiment 6: Positive Displacement Plunger Pump
2. Adjust the potentiometer beside the speed indicator, set the motor speed
to its maximum (i.e. About 950 rpm).
3. Slowly adjust the HV2 so that the pump head (pressure) is at 90%, record
the flow rate, differential pressure, power and speed once the readings are
stable (Refer Table 4).
4. Repeat step 3 with the following pump head readings of P2 = 80%, 70%,
60%, 50%, 40%, 30%, 20%, 10%. You can try any other intermediate
reading but never try to close the HV2. This is to ensure that the existing
pressure develop in the pipeline doesn’t exceed the limit.
5. The data you have collected will enable you to plot the following
characteristic curve;
Note:
i. Please turn off the pump by pressing the stop push button at the end
of experiment.
ii. Adjust the potentiometer to its minimum setting (fully anti clockwise).
5
Fluid Mechanics (CLD 10603)
Experiment 6: Positive Displacement Plunger Pump
Warning: Do not close the HV2 completely when P2 is running. This may cause
serious damage to the instrument.
Results
6
Fluid Mechanics (CLD 10603)
Experiment 6: Positive Displacement Plunger Pump
List of Abbreviation
7
Fluid Mechanics (CLD 10603)
Experiment 6: Positive Displacement Plunger Pump
113.56 x 60
Volumetric flow rate, m3/hr Q = (q/100) x
1000
DP 3 x 10.2 x 10
4
Pump Total Head, m H = (Zc 2- Zc 1) + x
100 w g
Pump Power Output, W Po = (wg HQ) / 3600
Po
Pump Efficiency, % ETA = x 100
Pi
Po
Overall Efficiency, % ETA gr= x 100
PMI
Q
Volumetric Efficiency, % ETAv = x 100
Vi x N x 60
Discussion
Plot all the characteristic curves which have been stated in all the experiment
8
Fluid Mechanics (CLD 10603)
Experiment 6: Positive Displacement Plunger Pump
Tutorial
1. Define pump.
pump?
3. List down three factors which influence the choice of pump for a
particular operation.
Conclusion
References
1. White, F.M. Fluid Mechanics 4th Ed. McGraw Hill
2. McCabe, W.L., Smith, J.C and Harriot Unit Operations of Chemical
Engineering 5th Ed. McGraw Hill
3. Anthony Esposito. Fluid Mechanics with Applications. Prentice Hall
International Inc.
4. Debler, W.R. Fluid Mechanics Fundamentals. Prentice Hall International
Inc.