You are on page 1of 2

TEST REPORT DATE 02-09-2020 12:07

PAGE 1 of 1

CUSTOMER

SANTAFE

PERFORMER

ABDO><

INJECTOR INFORMATION
MANUFACTURER MODEL S/N

BOSCH PIEZO 0445116018 1: — 2: —

AUTO TEST RESULTS


RAIL PRESSURE, IMPULSE INJECTION MEASUREMENTS
NOMINAL
Bar WIDTH, µS RATE, IPM 1 2

Clean run
Delivery, ml/min 300 2500 600 --- ± --- 0.00 0.00
Static Leak
Visual check — —
Recovery, ml/min 250 — — --- ± --- 0.00 0.00
Recovery T, °С 38 38
Static Leak
Visual check — —
Recovery, ml/min 1600 — — --- ± --- 0.00 0.00
Recovery T, °С 38 38
Back pressure
Delivery, ml/min 300 2500 600 --- ± --- 40.62 41.92
Recovery T, °С 38 38
Conditioning
Delivery, ml/min 1600 700 2000 --- ± --- 0.00 110.79
ISA detection
Delivery, ml/min 1600 700 2000 10.0 ± 10.0 0.00 111.42
ISA ✗ ✗
Full Load
Delivery, ml/min 1800 565 400 18.7 ± 1.8 0.00 17.84
Back Flow
Recovery, ml/min 1800 565 1000 11.0 ± 4.0 0.00 10.05
Recovery T, °С 41 41
Preinjection
Delivery, ml/min 1200 185 2000 3.8 ± 2.6 0.00 3.46
Low Load
Delivery, ml/min 300 580 2000 8.8 ± 4.4 9.82 10.58
Emission
Delivery, ml/min 800 525 330 6.1 ± 1.2 5.99 5.89

TOTAL : ✗ ✗

You might also like