You are on page 1of 4

JAGENBERG-GRUPPE

15.03.2016 HRahn

Preset Winding Carriage Position


The Position is detected by the Motor absolute Encoder. The Preset is to be done via the HMI HW
Preset Page.

Seite 1 von 4
JAGENBERG-GRUPPE

To access HW-Screen User „Maintenance“ must be selected

To Preset Service Mode must be activated. Therefore the Key switch in Main Desk +CD
must be turned to “ON” Position.

Emergency Stop must not be active and all Drives must be switched Off

Seite 2 von 4
JAGENBERG-GRUPPE

When Service Mode is active it is Shown on Main Screen in “Operation Mode” Field

The Preset value is the distance measured from the empty core to the contact roller.

Core radius

Seite 3 von 4
JAGENBERG-GRUPPE

The Contact Roller must be free (contact cylinder fully moved out).

To Preset the Softbutton “Preset” must be pushed for 3s.

Seite 4 von 4