You are on page 1of 15

Widepath ™

The Easy to Use Deep Cleaner

Congratulations on your purchase!


SteamVac™ Widepath ™ cleaners have
6 rotating brushes that deep clean
carpets and scrub bare floors!

SteamVac™ Widepath™ Deep Cleaner cleans carpet fibers


by applying hot tap water and cleaning solution.

www.hoover.com
Fill in and Retain Owner’s ENGLISH ➜ pp. 1-14
This HOOVER deep cleaner is
designed for deep cleaning carpet,
Manual ESPAÑOL ➜ pág. 16-24
rugs, carpeted stairs and upholstery.
The model and serial numbers are
FRANÇAIS ➜ p. 26-34
located on the data label on the back
of the handle. Review this manual before
For your personal records, please
enter the COMPLETE model and serial
operating deep cleaner
numbers in the spaces provided and
retain this information.
Your deep cleaner is model
Important Safeguards!
When using an electrical appliance, always follow basic
and has serial number precaution, including the following:
READ ALL INSTRUCTIONS BEFORE USING APPLIANCE.

It is suggested that you attach your


sales receipt to this owner s manual.
WARNING:
• Use indoors only.
To reduce the risk of fire, electric
shock, or injury:

Verification of date of purchase may • Use only on surfaces moistened by the cleaning process or small spills. Do
be required for warranty service of not immerse product.
your Hoover product. • Connect to a properly grounded outlet only. See “Grounding Instructions”.
• Do not clean over floor electrical outlets.
• Do not use without tanks in place.
• Use extra care when cleaning on stairs. Do not place deep cleaner on stairs.
• Use deep cleaner only for its intended use as described in the instructions.
• Use only attachments recommended by The Hoover Company; others may
cause hazards.
Index • The use of an extension cord is not recommended. If an extension cord is
Important safeguards . . . . . . . . . . 2 absolutely necessary, use at least a 16 gauge 3-wire cord which has a 3-prong
Assembly . . . . . . . . . . . . . . . . . . . 3-5 grounding type plug and a 3-pole receptacle that accepts the machine plug.
Carton contents. . . . . . . . . . . . . . 3 • Unplug deep cleaner when not in use. Turn off all controls before unplugging.
How to use . . . . . . . . . . . . . . . . . . 6-8 • Unplug before connecting the powered hand tool.
Agitator speed selector . . . . . . . 7 • Always disconnect cord from electrical outlet before servicing the deep cleaner.
Automatic “shut-off” . . . . . . . . . . 7 • Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Deep cleaner description . . . . . . 6 • Never handle plug or appliance with wet hands.
Emptying the recovery tank . . . . 8 • Do not pull or carry by cord, use cord as a handle, close door on cord or pull
Filling the clean solution tank . 7-8 cord around sharp edges or corners. Do not run appliance over cord. Keep
How to clean cord away from heated surfaces.
After cleaning . . . . . . . . . . . . . . . 9 • Do not use with damaged cord or plug. If appliance is not working as it
Before you begin . . . . . . . . . . . . 9 should, has been dropped, damaged, left outdoors, or dropped into water, take
Carpet cleaning . . . . . . . . . . . . . 10 it to a Hoover Factory Service Center or Authorized Hoover Warranty Service
Cleaning bare floors . . . . . . . . . 11 Dealer.
Picking up spills . . . . . . . . . . . . 10 • Close supervision is necessary when any appliance is used by or near
Using the tools . . . . . . . . . . . . . 11 children. Do not allow deep cleaner to be used as a toy or to run unattended at
Attaching tools . . . . . . . . . . . . 11 any time.
Cleaning carpeted stairs. . . . . 12 • Do not point tools toward people or pets.
Cleaning upholstery . . . . . . . 13 • Use only commercially available floor cleaners intended for machine
Maintenance application. Do not use any type of wax with deep cleaner.
If you have a problem . . . . . . . . 14 • To assist In reducing drying time, be certain the area is well ventilated when
Lubrication . . . . . . . . . . . . . . . . 14 using detergents and other cleaners with this machine.
Service . . . . . . . . . . . . . . . . . . . 14 • Keep detergents and other cleaners out of children's reach.
Storage . . . . . . . . . . . . . . . . . . . 14 • Do not use to pick up flammable or combustible liquids such as gasoline or
Warranty . . . . . . . . . . . . . . . . . . . . 14 use in areas where they may be present.
• Do not pick up chlorine bleach, drain cleaner, gasoline or any other toxic
material with this appliance.
• Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.
• Avoid picking up hard, sharp objects with the deep cleaner. They may damage
the machine.
• Keep hair, loose clothing, fingers, feet and all parts of body away from
openings and moving parts.
• Do not put any object into openings. Do not use with any opening blocked;
keep free of dust, lint, hair, and anything that may reduce air flow.
• To help prevent matting and resoiling, avoid contact with carpets until they are
dry. Keep children and pets away from carpets until they are completely dry.
• Store in a dry place. Do not expose machine to freezing temperatures.
© 2002 The Hoover Company
www.hoover.com
2 Save these instructions!
Grounding
Instructions
D F
A
B G

A temporary adapter (D) may be used to


C DANGER-
Improper connection of the equipment-
connect this plug to a 2-pole receptacle
(E) if a properly grounded outlet is not
available. The temporary adapter should
This appliance must be grounded. If it grounding conductor can result in the be used only until a properly grounded
should malfunction or breakdown, risk of electric shock. Check with a qual- outlet (B) can be installed by a qualified
grounding provides a path of least resis- ified electrician or service person if you electrician. The green colored rigid ear,
tance for electrical current to reduce the are in doubt as to whether the outlet is lug, or the like (F) extending from the
risk of electric shock. This appliance is properly grounded. Do not modify the adapter must be connected to a perma-
equipped with a cord having an equip- plug provided with the appliance - if it nent ground (G) such as a properly
ment-grounding conductor (C) and will not fit the outlet, have a proper outlet grounded outlet box cover. Whenever
grounding plug (A). The plug must be installed by a qualified electrician. This the adapter is used, it must be held in
plugged into an appropriate outlet (B) appliance is for use on a nominal 120 place by a metal screw. NOTE: In
that is properly installed and grounded in volt circuit and has a grounding plug Canada, the use of a temporary adapter
accordance with all local codes and that looks like the plug illustrated in is not permitted by the Canadian
ordinances. sketch (A). Electrical Code.

1. Assembly
Carton contents
1-1

C D
Carpet Bare
Upholstery Pre-
Cleaner
floor
cleaner Cleaner

F
G H

A B

Unpack deep cleaner from the carton and identify the


parts shown. Remove and dispose of the packing.

A. Deep cleaner
Contained in carton with hose:
B. Upper handle with powered hand tool
F. Hose
C. Bolts (2)
G. Stair/upholstery nozzle
D. Nuts (3 - one extra included)
H. Tool holder and screw (taped on rack under nozzle)
E. Hose holder

3
The assembled cleaner will look like this 1-3
drawing. Assemble handle
A1
1-2
A2

Attach upper handle


Remove clean solution tank (upper tank)
from deep cleaner.
With hose hook (A1) and cord hook (A2) to
back of deep cleaner, push upper handle
down onto lower handle. Push bolts into
holes on front of handle. If bolts will not
go through hole easily handle is not
pushed completely down.

1-4 1-5 1-6

Attach hose holder Place nuts in recessed areas on back When handle sections are completely
of the hose holder. Hold each nut in together, squeeze trigger (C) on upper
Position hose holder (B) onto handle by place while tightening each bolt securely handle.
matching tabs on rack with openings on (from the front of the handle) with a You will hear a “snap” when the
back of handle. Make sure holes for Phillips screw driver. trigger rod is in place.
bolts are aligned.
Only two nuts are needed on this model.
The extra nut is not required but has
been provided for your convenience.

1-7 1-8 1-9

Replace clean solution tank (upper tank) Slide rack down into place. Insert screw
by positioning bottom first. Press on
Attach tool holder at (D) and tighten with a Phillips screw-
tank handle to snap top of tank into Remove tool and taped screw from driver.
place. holder.
Insert projections on holder into slots on
4 back of cleaner.
1-10 1-11 1-12

A2

F
E

Press cord into cord clip on back of Storing hose & tools Continue wrapping hose under lower
handle. Pull cord tight and wrap cord hook (E). Snap hose end fully into hold-
around hooks (A2). Store hose on holder by first positioning er (F).
hose in front section of clip. The hose end must be pushed com-
pletely down into holder (F) to ensure
maximum suction when cleaning
floors.

1-13 1-14 1-15

Position stair/upholstery nozzle in holder Powered hand tool To remove powered hand tool, pull it
at base of cleaner and snap it into place down and outward.
The powered hand tool is shipped in a
as shown at arrow. To reposition the tool, reverse this proce-
plastic bag for protection. Remove the
dure.
bag before using the tool by first open-
ing tool door.

1-16

How to reattach tool


cover
The tool cover is designed with a break-
away feature which allows it to snap free
if it is pushed open too far.
To reattach, align hinges of cover with
holes on sides of tool storage area.

5
2. How to use
The assembled deep cleaner will look like the drawing.
Deep Cleaner Description
2-1 1. Hand grip 14. Brush speed selector:
2. Solution trigger: press to slide selector to set brush
1 release clean solution. speed on HI, LO, or OFF.
3. Hose 15. Hood
2 4. Hose holder: wrap hose 16. Edge bristles: on both sides
5 around holder and top hose of the hood for cleaning
hook (6) for storage. close to edges of carpet.
3 5. Hose hook 17. Nozzle
6 6. Cord hooks: wrap cord 18. Cleaning mode indicator:
7 around hooks for storage. shows either floor or tool
The top hook can be rotated usage
8 right or left for quick and 19. ON/OFF pedal
easy cord release. 20. Handle release pedal: step
9
7. Powered hand tool on pedal to lower handle to
10 4 8. Carrying handle operating (floor) position;
9. Clean solution tank handle 21. Stair/upholstery nozzle
11 10. Clean solution tank cap/
12 measuring cup
11. Clean solution tank: holds This deep cleaner is intended
6
13 cleaning solution. for household use.
12. Recovery tank handle:
14 raise handle to unlock tank
21
for removal; lower handle
forward to lock tank into
18 position.
20
13. Recovery tank: holds dirty
16
15 solution.
19
17

Operate deep cleaner only at voltage specified on data plate on back of cleaner.
Plug deep cleaner into a properly grounded outlet.

2-2 2-3 2-4

Floor
C
Cleaning Mode
Tool
D

A B

ON/OFF pedal & Cleaning mode To transport


Handle release pedal indicator To move your deep cleaner from room to
Step on pedal (A) to turn deep cleaner Indicator will show a green window next room put handle in upright and locked
on. Step on pedal again to turn deep to FLOOR (C) when handle is in the position tilt deep cleaner back on
cleaner off. operating position for cleaning carpet wheels and push forward.
rugs and bare floors.
Step on pedal (B) to lower handle to
operating position. Handle does not lock Indicator will show a green window next
into a single position but “floats” to allow to TOOL (D) when handle is in the
convenient operation. upright position for tool use on stairs,
upholstery, etc.
Deep cleaner automatically diverts
suction from FLOOR to TOOL when
handle is raised from the operating to
the upright position.

6
2-5 2-6 2-7
E

Bru
sh
OF Sp
F e
LO ed
HI

The deep cleaner may also be lifted by


placing a hand under the upper clean
Automatic “shut off” Brush speed selector
solution tank handle as shown. When the recovery tank (lower tank) is full Your ‘SteamVac’ deep cleaner has three
the automatic shutoff mechanism will shut agitator brush settings.
off the deep cleaner suction (suction will Hl - for normal cleaning of carpet and
be noticeably reduced). bare floors
At that time the yellow float disk will rise LO - for gentle cleaning of carpets and
to the top of the recovery tank lid (E). bare floors
The deep cleaner will no longer pick up OFF - for cleaning carpets and bare
dirty solution and the motor sound will floors when brushing is not desired.
become noticeably higher in pitch. (Such as when picking up liquid spills.
See page 10.)
When this happens turn deep cleaner
Slide selector button to the desired set-
off and empty recovery tank before ting before cleaning.
continuing use.
Check clean solution tank also; it may
need to be refilled.
Do not use without float and float
retainer in place. If broken or dis-
lodged, take to an Authorized Hoover
Service Center or Dealer for repair.

2-8 2-9 2-10


5 OUNCES/
150 ml

Carry tank to a sink. Rotate tank cap Turn cap (A) upside down to serve as a
The tanks counterclockwise and lift up to remove measuring cup.
Clean solution tank cap. Using cap, measure detergent following
(upper tank) the chart below.
The clean solution tank holds the clean-
ing solution that is to be dispersed onto For heavy traffic areas: For carpet, carpeted stairs and uphol-
the surface to be cleaned. Pre-treat with HOOVER PreCleaner* stery:
How to fill Spray. Fill cap to fill line (5 ounces) with HOOVER
If you do not have access to the Carpet/Upholstery Detergent.
Disconnect deep cleaner from PreCleaner Spray, double the amount
electrical outlet. For bare floors:
of HOOVER Detergent (use 2 capfuls
Place deep cleaner handle in the or 10 ounces per 1 gallon tank). Fill cap to fill line (5 ounces) with HOOVER
upright, locked position. Bare Floor Cleaner*
To remove tank, press down on tank Do not use Bare Floor Cleaner on carpet or
upholstery. Do not use any type of wax
handle and pull forward. *Available at additional cost if not with your ‘SteamVac’ ‘Widepath’ deep
included with your model. cleaner.

Continued ➜ 7
NOTE: Use only HOOVER detergents. 2-11 2-12
They are specially formulated for use
with your ‘SteamVac’ deep cleaner.
CAUTION: Detergents contain B
Anionic and Nonionic Surfactants.
Avoid contact with eyes and skin. In
case of contact with eyes, flush with C
cold water for 15 minutes. In case of
contact with skin, wash with water. If
Irritation persists, call a physician.
For Medical Information (U.S.) call D
1-800-752-7869.
Pour detergent into tank. Fill tank to If rubber ring (C) on cap has become
fill line (B) (1 gallon) with hot tap dislodged, reposition it with uneven
water. side against ledge (D) as shown.
To assure proper performance, use only
HOOVER cleaning detergent.

2-13 2-14 Recovery tank


(lower tank)
The recovery tank holds the dirty solu-
tion that is picked up from the carpet.
When the recovery tank is full, the auto-
matic shut-off will engage (see page 7)
and the tank must be emptied.
How to empty
Turn deep cleaner off and disconnect
from electrical outlet.
To prevent possible leaking, remove
clean solution tank (Fig.2-8) by pressing
Replace cap. Rotate cap clockwise Position bottom of tank into unit and down on tank handle and pulling for-
until it locks In place. Cap must be press on tank handle to snap tank into ward; set tank aside (do not set tank
locked In place for proper perfor- place. on furniture).
mance and to prevent leaking.
Step on handle release pedal (Fig. 2-2)
and lower handle until it rests on the
floor.

2-16 For full suction, it is important that


2-15 the recovery tank lid is properly
UNLOCK
secured before cleaning.

LOCK Raise tank handle to carrying position to


place it into base of deep cleaner. Move
handle completely forward to lock tank
into place (see Fig. 2-15).

Raise handle of deep cleaner to upright


position and reposition upper clean
Raise handle to carrying position To remove tank lid, lower handle com- solution tank.
(straight up) to unlock tank from base of pletely toward back of tank and lift off
deep cleaner. Lift tank from deep clean- lid.
er and carry it to a sink or drain. Empty the tank and reposition the lid.

8
under “Fill clean solution tank”, Figs. 2-8 to Do not saturate carpet or upholstery with
3. How to clean 2--14. Wet a white absorbent cloth with the
solution. In a small, hidden area, gently rub
PreCleaner.
If you do not have access to the
the surface with the dampened cloth. Wait PreCleaner Spray, double the amount
Before you begin ten minutes and check for color removal or of HOOVER Detergent (use 2 capfuls
cleaning bleed with white paper towel or cloth. If sur- or 10 oz. per 1 gallon) in the clean
solution tank.
face has more than one color, check all col-
a. Vacuum thoroughly - For carpet,
ors. No cleaning solution removes all stains from
use a HOOVER vacuum cleaner with an
agitator for best results. Vacuum uphol- d. When cleaning entire floor, move all carpets. Stain removal varies with the
stery with a vacuum cleaner with clean- furniture out of area to be cleaned type of spill, time elapsed before removal,
ing tool attachments. Use a crevice tool (may not be necessary if only high traffic carpet material, and carpet type.
to reach into tufts and folds. Do not use areas are to be cleaned). For furniture f. To prevent staining, use plastic or alu-
the ‘SteamVac’ deep cleaner as a dry too heavy to move, place aluminum foil minum foil to protect wood or metal sur-
vacuum cleaner. or wax paper under legs. This will pre- faces from possible water spray.
vent wood finishes from staining carpet. g. To avoid wetting and possible damage
b. For upholstery, check cleaning
Pin up furniture skirts and draperies. to wood floors underneath area rugs/car-
code - Use your HOOVER ‘SteamVac’
‘Widepath’ deep cleaner only if the e. Pretreat spots and heavy traffic pet, either move area rugs/ carpet to a non-
upholstery fabric is marked with a “W” areas with HOOVER ® PreCleaner*- wood bare floor surface or place waterproof
(for “wet” clean) or “S/W” (for Test PreCleaner for colorfastness by first material (e.g. plastic) underneath them
“solvent/dry” or “wet” clean). Do not spraying it on a hidden area; wait ten before cleaning.
clean fabric marked “S” minutes and blot with white paper towels *Available at additional cost if not included
(“solvent/dry” clean only). If your or cloth. with your model.
upholstery does not have a code, seek If no color change is visible, spray
PreCleaner onto spots and traffic areas. See pages 10-13 for instructions on various
professional assistance.
Wait at least ten minutes. Use your cleaning tasks.
c. Test for colorfastness - Mix detergent
‘SteamVac’ ‘Widepath’ deep cleaner to pick
and water according to the instructions
up PreCleaner and spot. Repeat until spot
is removed; carefully scrub with a house-
hold scrub brush if necessary.

b. If desired, the carpet may be rinsed.


After cleaning Rinsing is not necessary for cleaning,
3-1
a. Allow carpet or upholstery to dry. To but it may improve the surface’s appear-
help prevent matting and resoiling the ance after it is dry.
carpet, keep children and pets away If rinsing is desired, be careful not to
from surface until it is completely dry. over-wet the carpet or upholstery.
If it is necessary to walk on damp car- Allow time for carpet or upholstery to
pet, place towels or white cloths on the dry completely between cleaning and
traffic areas. rinsing. To rinse, follow the same proce-
If furniture must be replaced before the dure for cleaning only using hot tap
carpet is dry, place plastic or aluminum water with no detergent in the upper
foil under legs of furniture so metal clean solution tank.
slides or wood finishes will not stain the d. Remove lint from filter screen located
c. Empty tanks, rinse with clear water
carpet. inside recovery tank.
and let air dry. Rinse the solution tank
cap and recovery tank lid and let air dry.

3-2 Return cleaner to upright position. To clean nozzle


f. Vacuum thoroughly after carpet has If lint or other debris becomes lodged in
completely dried. This will help reduce nozzle, do not attempt to remove
any shading left by the deep cleaner’s nozzle cover.
brushes.
Pour one to two cups of clear water on a
g. If a tool has been used, remove tool non-carpeted floor. Do not pour water
from hose and return hose to storage onto a wood floor.
position. The hose end must be Pick up the water with your deep clean-
pushed completely down into holder er. Repeat as necessary until debris is
to ensure maximum suction when flushed out of nozzle.
e. Remove lint from filter screen located cleaning floors (Fig. 1-12).
on bottom of cleaner as follows. Note:
When brushes seem to be rotating
slowly, disconnect deep cleaner from
electical outlet and check and clean
this screen.
Tilt cleaner back so handle rests on floor.
Squeeze frame, lift and pull it out. Wipe
off screen and push frame back into
place. Continued ➜ 9
3-3 3-4
Carpet Cleaning
Read “Before you begin cleaning”
instructions on page 9.
1. Fill clean solution tank (upper tank)
with HOOVER Carpet/Upholstery
Detergent according to instructions for
Figs. 2-8 to 2-14.
2. Move speed selector to LO for gen-
tle cleaning or Hl for normal cleaning.
A nozzle clean-out tool, available at 3. Dry hands and plug cord into a prop-
additional cost if not included with your erly grounded outlet.
cleaner, can be used for removing
Do not clean over floor electrical out-
debris or if a non-carpeted floor is not
lets. 5. Squeeze trigger to release cleaning
available.
To use the tool: Disconnect deep 4. To avoid walking on damp carpet, solution and slowly push deep cleaner
cleaner from electrical outlet. start at the end of the room farthest from forward (equals one wet stroke).
Slide tool into nozzle and remove debris the door or path to sink where tanks will 6. Continue to squeeze trigger and
as shown. be emptied and filled. slowly pull deep cleaner back toward
To clean the outside of the machine, Step on handle release pedal and lower you (second wet stroke). Release trigger
wipe off dirt with a cloth dampened in handle to operating position; turn deep and slowly push deep cleaner forward
warm water and mild detergent. Do not cleaner ON. over area just sprayed with solution (dry
use solvent or petroleum based prod- stroke). Then slowly pull deep cleaner
ucts to clean the machine. back toward you without squeezing trig-
ger (dry stroke).
7. Overlap strokes by 1 inch to help pre-
vent streaking.
Keep nozzle flat on floor for both for-
ward and reverse strokes.

8. For heavily soiled areas, repeat steps When picking up spills on bare floors,
5-7. Avoid saturating carpet, as noted Picking up spills use only the floor nozzle with the bare
below. floor attachment (available at additional
Your deep cleaner may also be used to cost if not included with your cleaner) in
Note: To avoid saturating carpet, do pick up small liquid spills (1 gallon or
not use more than 4 wet strokes over place and speed selector in the OFF
less, never to exceed 1/4 inch in position (this will help prevent spreading
one area. Always end with dry depth) on carpet, upholstery, or bare
strokes. the spill).
floors.
It is best to alternate wet and dry If a spot is left, the stair/upholstery nozzle is
1. For best results, pick up spills imme- generally more effective for removing it.
strokes as described above. diately by placing the stair/upholstery
nozzle just above the spill and suction Although no cleaning solution can com-
For best cleaning results and to aid in
up any residue on top of the carpet. pletely remove all spots, they can be treat-
faster drying of carpet, end with more
ed by following the instructions provided by
dry strokes. (Continue using dry strokes 2. If the spill remains, place either the
the manufacturer of the carpet, upholstery,
until little water is visible passing stair/ upholstery nozzle or floor nozzle
or bare floor surface being cleaned.
through the recovery tank lid.) with brushes turned OFF in front of the
Empty recovery tank when the motor spill, pull the nozzle very slowly over the Do not use the deep cleaner to pick up
sound becomes higher pitched and spill initially with suction only. flammable or combustible liquids or
there is a loss in suction (see chemicals.
Repeat with spray and suction.
“Automatic shut-off”, Fig. 2-6) When finished, follow “After cleaning”
When finished cleaning, follow “After instructions on pages 9.
cleaning” instructions on pages 9.

10
Cleaning bare floors 3-5 3-6
A
How to attach bare floor
attachment
(available at additional cost if not TA
BA
RO

TE LOOR
RE

F
O

ON
N
included with your cleaner)

OR

TE
FLO
B

R O TA
BARE
Disconnect deep cleaner from electri-
cal outlet.
To prevent possible leaking, remove
clean solution tank (Fig. 2-8) and recov- TA
BA
RO

TE LOOR
RE

ery tank (Fig. 2-15) before positioning

F
O
N
bare floor attachment.
Set tanks aside (do not set tank on furni-
2. With foam strip (A) (located under the 3. Push attachment against nozzle while
ture).
netting) in position as shown, place rotating attachment downward until both
1. With handle in upright position, tilt attachment on front of nozzle (B). ends snap into place.
cleaner back so that handle rests on the Make sure arrow on end of attachment (Note: Some force may be required to
floor. points in the direction as shown. rotate and snap attachment into place.)

4. Return deep cleaner to upright posi- 3-8


tion. Lower handle and replace recovery Using the tools C
tank.
5. Raise handle to upright position and 3-7
reposition clean solution tank.
To clean floor B
Read “Before you begin cleaning”
instructions on page 9.
A
Do not use the deep cleaner on hard-
wood floors. D
1. Fill clean solution tank with HOOVER
Bare Floor Cleaner* according to Your model includes the following tools.
How to attach tools
instructions for Figs. 2-8 to 2-14. A. Powered hand tool has rotating
brushes for extra scrubbing action on Disconnect deep cleaner from electri-
Do not use any type of wax with your cal outlet.
deep cleaner. small carpet areas, carpeted stairs and
upholstery. 1. Place handle in upright position and
2. Move speed selector to the Lo or Hl remove hose from rack.
B. Stair/upholstery nozzle has a built-in
position for scrubbing or OFF if All tools attach to the hose in the same
brush to help provide the scrubbing
scrubbing is not desired. manner:
action some spots may need for
3. Dry hands and plug deep cleaner removal. 2. Connect tool to hose by sliding it onto
into a properly grounded outlet. connector until the tab (C) locks it
4. Step on handle release pedal and securely.
lower handle to operating position; turn Using your thumb, push forward and
deep cleaner ON. up on the latch (D) to remove tool as
shown.
5. To release solution, press trigger.
Slowly move deep cleaner forward and Before using tool
backward over area to be cleaned. It may be necessary to remove air from
6. To pick up dirty solution, release trig- the system (“prime the pump”) so the
clean solution will flow to the tool. Follow
ger and slowly move deep cleaner over these steps:
area where solution has just been dis-
persed. Use both forward and reverse 1. Attach tool to hose and turn the deep
cleaner ON.
strokes.
2. Put the tool on a hard surface or
7. Empty recovery tank when the motor against your hand to block off the suc-
sound becomes higher pitched and tion.
there is a loss in suction (see
3. Wait a few seconds (can take up to 15
“Automatic shut-off”, Fig.2-6) seconds). Then squeeze the trigger and
8. When finished cleaning, follow “After begin cleaning.
cleaning” instructions on pages 9-10. Follow the instructions on page 13 for
Disconnect deep cleaner from electri- the appropriate cleaning task.
cal outlet and remove attachment from
nozzle. Rinse it in clear water. Do not
remove plastic screen or foam from
attachment.
*available at additional cost if not includ-
ed with your model Continued ➜ 11
3-9 3-10

After using tool 3. Drain hose by turning deep cleaner


ON and holding end of hose up for sev-
1. Follow steps a and b for “After clean- eral seconds. Do not press trigger.
ing” on page 9.
4. Disconnect deep cleaner from electri-
2. Rinse tool and hose by filling sink with cal outlet.
a small amount of water. Turn
deep cleaner ON and pickup the water 5. Drain solution tube (located inside
with the tool. hose) by pointing end of hose in sink
and pressing trigger.
6. Proceed with steps c, d, and e, for
“After cleaning” on page 9.

Cleaning carpeted 3-11 3-12


stairs
Read “Before you begin cleaning”
instructions on page 9. A A
1. Place handle in upright position.
Agitator brushes will not rotate while
handle is in upright position.
2. Fill clean solution tank with HOOVER
Carpet/Upholstery Detergent according
to instructions for Figs. 2-8 to 2-14. B B
3. Attach tool to end of hose.
6. Turn deep cleaner ON. If necessary, 9. Lift tool, and position it against riser.
4. Hose length may require that refer to “Before using tool” section to Pull tool slowly over carpet without
machine be placed at the top of the remove air from the system. pressing trigger (dry stroke).
stairs to clean upper half of stairway
7. Pre-spray the carpeted stair by hold- It is best to alternate wet and dry strokes
and at bottom of stairs to clean lower as described above. End with more dry
half. ing the tool (A) or (B) about one inch
above the carpet and push it forward strokes to aid in faster drying of carpet.
To prevent machine from falling, use while pressing the trigger (equals one 10. Overlap strokes by 1/2 inch to help
extra caution when cleaning on wet stroke). prevent streaking.
stairs.
8. Position tool against the riser and slightly To avoid saturating carpet, do not use
Do not place deep cleaner on stairs. press it into carpet pile. Press the trigger more than 4 wet strokes over any one
Do not point tools toward people or and pull the tool slowly over the carpet area. Always end with dry strokes.
pets. (second wet stroke). Release trigger at end If additional cleaning is necessary, wait
5. Dry hands and plug deep cleaner of stroke. until the carpet is completely dry before
into a properly grounded outlet. using the tool again.
11. Empty recovery tank when the motor
sound becomes higher pitched and
there is a loss in suction (see “Automatic
shut-off”, Fig. 2-6).
When finished cleaning, follow “After
cleaning” instructions on page 9 and
“After using tool” instructions on page 12.

12
Cleaning upholstery 3-13 3-14

Read “Before you begin cleaning”


instructions on page 9.
Be sure to check the cleaning code on A A
your upholstery. Use your deep cleaner
only on upholstery marked “W” or
“W/S”.
1. Place handle in upright position.
Agitator brushes will not rotate while
handle is in upright position. B B
2. Fill clean solution tank with HOOVER 6. Gently press the tool onto the fabric. 10. For heavily soiled areas, it may be
Carpet/Upholstery Detergent according Press the trigger and slowly pull the noz- necessary to repeat the cleaning
to instructions for Figs. 2a-8 to 2-14. zle over the fabric. process. Make crisscrossing strokes to
3. Attach tool to end of hose. 7. Overlap strokes by 1/2 inch to help the original pattern; overlap each pass.
Do not point tools toward people or prevent streaking. Make no more than 2 passes with the
pets. Make additional strokes without pressing solution over any one area to prevent
4. Dry hands and plug deep cleaner into the trigger to remove more moisture. over-wetting and damage to fabric.
a properly grounded outlet. 8. To clean in corners or creases, lift the If additional cleaning is necessary, wait
5. Turn deep cleaner ON. If necessary, tool one-half inch from the fabric and until the upholstery is completely dry
refer to “Before using tool” section to press the solution trigger. The crevice before using the tool again.
remove air from the system. tool (included in some models) is very 11. Empty recovery tank when the motor
useful for this task. sound becomes higher pitched and
9. Vacuum up the solution with the tool there is a loss in suction (see “Automatic
without pressing the trigger. shut-off”, Fig. 2-6).
When finished cleaning, follow “After
cleaning” instructions on page 9 and
“After using tool” instructions on page 12.

4-1 4-2
4. Maintenance B

Removable brushes
Your deep cleaner is equipped with
removable brushes for easy cleaning.
A B
To remove brushes
Disconnect cleaner from electrical
outlet.
To prevent possible leaking, remove Press handle release pedal to lower Grasp inner portion of brush (A) and pull
clean solution tank and recovery tank. handle. Turn cleaner over so bottom is brush assembly out slightly to reveal
Set tanks aside. facing up. latches (B).

4-3 4-4 C 4-5


B D

B D
C

Press both latches (B) and pull brush To replace brushes Press brush firmly to snap into place.
block out. The brushes can be cleaned
Align posts (C) on both ends of brush
under running water.
assembly with slots (D) in cleaner hous-
ing.
Make sure that the square post (E) also
aligns with the square hole (F). Turn
brushes slightly until post fits easily into
hole. 13
Storage Problem: Clean solution won’t
dispense
Before storing: Full Three Year
• Empty solution tank and rinse
thoroughly with clean water. Possible cause Warranty
Possible solution
• Replace empty solution tank and
• Solution tank not firmly in place
(Domestic Use)
turn deep cleaner ON. Squeeze
trigger and push deep cleaner for- • Make sure tank is securely locked in
position Your HOOVER® appliance is warranted
ward and back several times to
in normal household use, in accordance
expel any solution remaining in the • Solution tank empty
with the Owner’s Manual against original
deep cleaner’s system. (Do not use • Refill tank according to instructions for
defects in material and workmanship for
deep cleaner on wood floors.) surface being cleaned
a period of three full years from date of
• Empty recovery tank and rinse • Recovery tank lid not on purchase. This warranty provides, at no
thoroughly with clean water. correctly cost to you, all labor and parts to place
Allow brushes and underside of deep • Make sure lid is firmly in place this appliance in correct operating con-
cleaner to air dry thoroughly before • Pump needs to be “primed” (when dition during the warranted period. This
storing deep cleaner on a carpeted or using tool) warranty applies when the appliance is
wood surface. • See “Before using tool” section, p.12 purchased in the United States including
its territories and possessions, or in
Do not store deep cleaner with a full
solution tank in place.
Problem: Brushes won’t rotate during Canada or from a U. S. Military
floor cleaning Exchange. Appliances purchased else-
where are covered by a limited three
Lubrication Possible cause
Possible solution
year warranty which covers the cost of
parts only. This warranty does not apply
The motor is equipped with bearings
which contain sufficient lubrication for • Dirty filter screen on bottom of unit if the appliance is used in a commercial
the life of the motor. The addition of • Clean screen as shown in Fig. 3-2 or rental application.
lubricant could cause damage. Do not • Speed selector on OFF This warranty only applies when the
add lubricant to motor bearings. • Move speed selector to Low or Hi product is in use in the country or territo-
ry in which it is purchased.

5. If you have a Warranty service can only be obtained


by presenting the appliance to one of
problem Service the following authorized warranty ser-
vice outlets. Proof of purchase will be
If a minor problem occurs, it usually can To obtain approved HOOVER service required before service is rendered.
and genuine HOOVER parts, locate the
be solved quite easily when the cause is 1. Hoover Factory Service Centers.
nearest Hoover Factory Service Center
found by using the check list below. or Authorized Hoover Warranty 2. Hoover Authorized Warranty
Service Dealer (Depot) by: Service Dealers (Depots).
Problem: Machine won’t run
• checking the Yellow Pages under
For an automated referral of autho-
Possible cause Vacuum Cleaners - Household” OR
rized service outlets in the U.S.A.,
Possible solution • checking the list of Factory Service phone 1-800-944-9200 OR
• Not firmly plugged in Centers provided with this cleaner
visit The Hoover Company on-line at
• Plug unit in firmly OR -
www.hoover.com
• checking the Service section of The
• No voltage in wall receptacle This warranty does not cover pick up
Hoover Company on-line at
• Check fuse or breaker www.hoover.com OR - delivery, or house calls; however, if you
• Blown fuse/tripped breaker mail your appliance to a Hoover Factory
• Replace fuse/reset breaker • calling 1-800-944-9200 for an Service Center for warranty service,
automated referral of authorized transportation will be paid one way.
Problem: Low suction service outlet locations (U.S. only). While this warranty gives you specific
legal rights, you may also have other
Possible cause Do not send your cleaner to The Hoover rights which vary from state to state.
Possible solution Company in North Canton for service,
this will only result in delay. If further assistance is needed, or if
• Recovery tank full/automatic there are questions concerning this war-
shut off engaged If further assistance is needed, contact ranty or the availability of warranty ser-
• Remove and empty recovery tank The Hoover Company Consumer vice outlets, write or phone the
Response Center, North Canton, Ohio Consumer Response Center, The
• Hose end not secured
44720 Phone: 330-499-9499. Hoover Company, 101 East Maple St.,
• Ensure that hose end is pushed
completely down in holder (Fig. 1-12). In Canada, contact Hoover Canada, North Canton, Ohio 44720,
Burlington, Ontario L7R 4A8, Phone 1-330-499-9499.
• Blockage in tool on end of hose Phone: 1-800-263-6376.
• Remove tool and clear blockage In Canada, contact Hoover Canada,
Always identify your cleaner by the com- Burlington, Ontario L7R 4A8,
• Recovery tank lid not on plete model number when requesting 1-800-263-6376.
correctly information or ordering parts. (The
• Make sure lid is on securely model number appears on the back of
the handle.)
14
15

You might also like