SAFETY ALERT / 04

Hoist limit switch stopper of


Crawler crane (P&H) fell down
Incident Details:  Inadequacy or lapses in daily inspection by
Date of Incident: 24.01.2019 equipment operator.
Time of Incident: 00.50 Hrs
Location of the incident: SRU (PR-04-63) Recommendations:
While jerking the crane boom for concreting  Any kind of bypassing of manufacturer’s manual/
purpose the limit switch stopper fell down on instructions should be strictly prohibited.
ground from 14 meter height which was having  Daily visual inspection of whole equipment shall
weight of 3.6 KG. be carried out before operating the equipment
and should be recorded.
Root Cause:  Defective items / devices should be replaced
 By-passing or not adhering to Manufacturer’s immediately.
prescribed Preventive/ Periodical Servicing  Overhead moving parts of crane retained by bolt
Schedule & nut shall be retained using self-locking nuts/
 Inadequate periodic maintenance and lapses in check nuts/ split pins.
daily inspection by crane operator/ Supervisor.  Periodical maintenance shall be carried out
 Retaining bolt and nut assembly of anti-two without fail.
block were not periodically inspected for correct  Joint inspection shall be carried out fortnightly by
tightness and security. Thus over a period of P&M Coordinator, equipment operator and HSE
time got loosened which was not noticed due to personnel and should be duly recorded. The
absence of rigid daily inspection inspection shall include but not limited to
checking of the following accessories like swing
Probable cause: alarm, reverse horn, load chart, SLI visual &
audible alarms, limit switch functioning, anti-two
 The operator may have done boom jerking with
block condition.
overload.
 Unauthorized replacement of equipment parts or
 Nut and bolt system used to secure stopper
replacement with spurious parts should be
block around the wire rope of crane got slacken
strictly prohibited.
while jerking.
 Wear and tear of the chain link due to friction
with the hoist cable.
 Inadequate periodical maintenance of
equipment.

Broken Pieces of
Limit switch stopper

February 2019
SAFETY ALERT / 04

CORRECTIVE ACTION TAKEN:


1- Joint inspection of all cranes has been carried out for all heavy equipment. The team comprises HSE Advisors,
HSE officers, P&M Engineers and operators.

2- The chain used to hang anti- two block of crane hoist limit switch indicator has been replaced in all cranes by two
wire rope cables.

Before After

February 2019