Model code Sizing
OXS – 30LID – N – 1 – Z – Z – 2 – 2 – ACD /- The required OXiStop size (differential
operating volume) can be calculated
Product from the actual volume differences of
OXS = OXiStop cylinders, accumulators, hoses etc.
present in the system. In addition,
allowances must be made for the
Size volume required for thermal expansion
30LID = differential operating volume ≤ 30 l in the oil and for possible continuous
45LID = differential operating volume ≤ 45 l oil losses. This volume (except for
70LID = differential operating volume ≤ 70 l accumulators) should be doubled as a
150LID = differential operating volume ≤ 150 l safety margin.
250LID = differential operating volume ≤ 250 l Rule of thumb:
325LID = differential operating volume ≤ 325 l
500LID = differential operating volume ≤ 500 l Sum of total accumulator volume
+ 2x sum of volume difference for
cylinders, hoses,
Supply voltage, motors temperature expansion, etc.
N = 400 V / 50Hz / 3 Ph (MPG standard) * = OXiStop differential operating volume
244
Dimensions
min.400*
G
51 44,5 42,5 42,5
D
C
E F
A B C D E F G H
OXS 30LID 615 480 500 362 395 395 5 74
OXS 45LID 615 480 610 472 395 395 5 74
OXS 70LID 615 480 820 682 395 395 5 74
B
~93
H
[kg]
b1
OXS 30 LID 56
n2 x b1 (=b2)
OXS 45 LID 57
OXS 70 LID 62
OXS 150 LID 87
10
245
Assembly drawing