You are on page 1of 4

OXiStop

OXS LID series

Description Technical specifications


HYDAC's OXiStop is a tank solution
for hydraulic systems with integrated, OXS OXS OXS OXS OXS OXS OXS
hydraulically driven degassing and 30LID 45LID 70LID 150LID 250LID 325LID 500LID
dewatering unit. Hydraulic data
Differential operating volume ≤ 30 l ≤ 45 l ≤ 70 l ≤ 150 l ≤ 250 l ≤ 325 l ≤ 500 l
An integrated membrane prevents direct
contact with the ambient air. This means Typical degassing rate * 4 l/h
that the tank can be calculated for the Viscosity range 15 - 300 mm²/s
differential operating volume actually Maximum fluid flow rate
needed, thus reducing its size. The pump IN / OUT
flow rate is not important for the tank OXS 30, 45, 70 900 l/min
calculation.
OXS 150, 250 2700 l/min
A very low gas and water content is OXS 325, 500 5400 l/min
achieved in the fluid.
Fluid temperature range 10 - 80 °C
Thanks to the membrane which keeps the Ambient temperature range ** -20 - 40 °C
fluid “vacuum packed”, it is also possible Storage temperature range 0 - 40 °C
to install the OXiStop in extremely dusty or
humid environments. Relative humidity ** 0 - 80%, non-condensing
Filtration unit OLF 5
The OXS LID series is installed in a
Filter element, filtration unit N5DM002
custom-designed tank and contains all
necessary components. Contamination retention capacity,
200 g ISOMTD ® Δp = 2.5 bar
filter element
The OXS LID comes in seven standard Pump type, filtration unit Vane pump
sizes, with differential operating
volumes ranging from 30 to 500 litres. Flow rate, filtration unit 7.5 l/min
Combinations are also available. Operating pressure, filtration unit 10 bar
Clogging indicator Visual differential pressure indicator
Advantages:
zzReduced oil volume, typically by a factor
of 10 Electrical data, filtration unit
Supply voltage, motors See model code
zzUp to 80% less air content and reduced
dirt ingress extends oil service life Electrical power consumption 150 W
zzHigher process speeds Protection class to DIN 40050 IP54
zzHigher efficiency
zzReduced noise and wear due to less General data
cavitation Permitted fluids** Mineral oil to DIN 51524
zzIdeal for humid and dusty environments Sealing material ** NBR
zzReduced costs due to smaller size, Membrane material ** PUR
fewer installation costs, less oil required Typical membrane service life ≈ 6 years at 40 - 60 °C fluid temperature
and easier transport ≈ 2 years at 60 - 80 °C fluid temperature
zzLonger component service life, less * Typical values for ISO VG 46, 40 °C at gas saturation. The degassing rate depends on the
servicing total gas content in the oil, the oil temperature, and especially the oil viscosity. The degassing rate reduces as
viscosity increases.
** Others on request
E 7.657.1/07.16

243
Model code Sizing
OXS – 30LID – N – 1 – Z – Z – 2 – 2 – ACD /- The required OXiStop size (differential
operating volume) can be calculated
Product from the actual volume differences of
OXS = OXiStop cylinders, accumulators, hoses etc.
present in the system. In addition,
allowances must be made for the
Size volume required for thermal expansion
  30LID = differential operating volume ≤   30 l in the oil and for possible continuous
  45LID = differential operating volume ≤   45 l oil losses. This volume (except for
  70LID = differential operating volume ≤   70 l accumulators) should be doubled as a
150LID = differential operating volume ≤ 150 l safety margin.
250LID = differential operating volume ≤ 250 l Rule of thumb:
325LID = differential operating volume ≤ 325 l
500LID = differential operating volume ≤ 500 l Sum of total accumulator volume
+ 2x sum of volume difference for
cylinders, hoses,
Supply voltage, motors temperature expansion, etc.
N = 400 V / 50Hz / 3 Ph (MPG standard) * = OXiStop differential operating volume

Sealing material/membrane material Also, it is necessary to check whether the


1 = NBR seals, PUR membranes total oil volume in the system needs to be
returned to the tank when maintenance
work is carried out.
Return line filter
Z = without Items supplied
zzOXiStop LID according to model
Plate heat exchanger + motor-pump unit code with membrane cage and
Z = without integrated membrane, MiniOx
degassing unit, OLF 5 offline
filtration unit with optional CS 1000
Vacuum pressure monitoring, degassing unit ContaminationSensor and AS 3000
1 = pressure gauge AquaSensor, HNS electronic level
2 = electronic pressure sensor (EDS) sensor, breather filter and piping
for individual components, gasket
Level and temperature monitoring (interface to tank)
2 = electronic level sensor (HNS) zzOperating and maintenance
with integrated temperature sensor instructions
zzInstructions for tank installation
Measuring equipment
Z = without Accessories
ACD = AquaSensor (AS) + ContaminationSensor (CS) zzFilter elements for offline filter OLF
5 (1 x N5DM002 already installed)
Supplementary details Part number Designation
No details = standard
349494 N5DM002 (2 μm)

zzElectrical clogging indicators, see


* Supplied without cable or plug brochure 7.112 NF Inline Filter

Fluid level gauge (FSA)


for mounting on the
tank by the customer
(recommended)
OXS 30 Part no. 700095
OXS 45, 150, 325 Part no. 3858731
OXS 70, 250, 500 Part no. 3858747
Special screw for
fluid level gauge
(FSA) Part no. 3925870
(1x is required for
mounting)
E 7.657.1/07.16

244
Dimensions
min.400*

* Height for element replacement


~715

G
51 44,5 42,5 42,5
D
C

E F

A B C D E F G H
OXS 30LID 615 480 500 362 395 395 5 74
OXS 45LID 615 480 610 472 395 395 5 74
OXS 70LID 615 480 820 682 395 395 5 74
B

OXS 150LID 1015 680 610 472 795 595 5 -27


OXS 250LID 1015 680 820 682 795 595 5 -27
OXS 325LID 1415 880 607 472 1195 795 8 -127
OXS 500LID 1415 880 817 682 1195 795 8 -127

~93
H

X (1 : 2) Size Weight when empty


nxd

[kg]
b1

OXS 30 LID 56
n2 x b1 (=b2)

OXS 45 LID 57
OXS 70 LID 62
OXS 150 LID 87
10

OXS 250 LID 97


OXS 325 LID 140
10
OXS 500 LID 152
a1 a2 a1 X
n1 x a2 (=a3) a1 a2 a3 n1 b1 b2 n2 d n
OXS 30LID / 70 91
455 5 92 460 5 10 24
45LID / 70LID
E 7.657.1/07.16

OXS 150LID / 99.5 99.5


995 10 82.5 660 8 10 36
250LID
OXS 325LID / 116.25 116.25
1395 12 86 860 10 10 42
500LID

245
Assembly drawing
Item Component
1 OXS LID with membrane cage

3 Directional control valve


4 Valve and connection block
5
13 5 OLF 5 offline filtration unit
6 Clogging indicator on OLF 5 filtration
4 unit
6
7 7 Check valve
16
8 MiniOX (MOX) degassing and
19 1 dewatering unit
20 9 EDS electronic pressure sensor or
vacuum gauge (optional)
10 Filling port
18 11 Draining port
12 Pressure measuring point
9
13 13 8 HNS electronic level sensor
17 14 Port for visual tank fluid level indicator
4
7 16 Breather fitting
14
16 11 17 Air filter
1 3
12 18 CS ContaminationSensor (optional)
20 10
19 AS AquaSensor (optional)
20 Sight glass

8
17

14
11
3
12
10

Hydraulic circuit Item Component


  2 Tank membrane

  5 OLF 5 offline filtration unit

  8 MiniOX (MOX) degassing and


dewatering unit
6 18 13
13 HNS electronic level sensor
CS
12 17 Air filter

AS
11 G 1/4" 14
G 1/2" G 1/4"
19
10
G 3/4"
9
5 7 17
3 15 16 20
21 4 8
G 1/2"

2
1

Note HYDAC FILTER SYSTEMS GMBH


The information in this brochure relates to the operating conditions and Industriegebiet
E 7.657.1/07.16

applications described. D-66280 Sulzbach / Saar


Tel.: +49 (0) 6897/509-01
For applications and operating conditions not described, please contact the relevant Fax: +49 (0) 6897/509-9046
technical department. Internet: www.hydac.com
Subject to technical modifications. E-Mail: filtersystems@hydac.com

246

You might also like