You are on page 1of 2

DESIGN OF RAFT FOOTING CF5

DESIGN CALCULATION SUMMARY

Load on all columns = W1= 15745 KN


Load From Lift = W2= 0 KN
Load From retaining wall = W3= 0 KN
Other Loads = W4= 0 KN
Self Weight Of Footing = W5= 1574.5 KN
Total design load on footing P= 17319.5 KN

SBC of soil = SBC= 150 KN/m2


Required Area of Footing Ao=P/SBC= 115.46 m2
Footing size provided ( Lf x Bf )= 130.45 m2
Net upward press. (total load/A)= Po= 120.70 KN/m2

Max. c/c dist. Of column in short dire. A= 3.0 m


Max. c/c dist. Of column in long dire. B= 2.5 m

Max. Hogging BM in short direction (m1)=


m1= (Po X A2)/10 (Mh1)= 108.63 KN-m
Max. Hogging BM in long direction (m2)=
m1= (Po X B2)/10 (Mh2)= 75.44 KN-m

Effective depth from max. BM consideration


d=((M max*10^6)/(R*b))^0.5 = 368 mm
Provide over all depth of footing = Do= 600 mm
Effective depth provided = dy= 550 mm Depth is Ok

CHECK FOR TWO WAY SHEAR (Punching)

Max. load on column = P max= 750 KN


Column provided = (BxD)= 200 X 600
Critical section for two way shear is a peripheral sec. at
a distance dy/2 from periphery of the column.

Length of the peripheral critical section at a distance dy/2


from column face L1=D+2*dy/2= D+dy = 1150 mm

Width of the peripheral critical section at a distance dy/2


from column face B1=B+2*dy/2= B+dy = 750 mm

Area resisting shear A2=2(L1+B1)Xdy = 2090000 mm


Shear strength of concrete for two way bending
Tuc2 = ks*Tuc where Tuc=0.25(fck)^1/2
for m25 concrete Tuc=0.25*(25)^1/2 = 1.25 N/mm2
ks=1.0 Tuc2= 1.25 N/mm2

Shear strength of concrete for two way bending


Vuc= Tuc2*A2 Vuc= 2612.5 Kn

Design shear Vud =1.5*Po(Lf*Bf - L1*B1)=


5.2 2.2 Vud= 1915 Kn Depth is Ok
Since Vud< Vuc Foundation is safe in two way shear

STEEL CALCULATION

Area of steel required in short direction


Ast1= (Mh1*10^6)/(δst*j*d) 954 mm2
Top & Bott. Steel Provided in Short direction =
Y 16 @ 120 C/C
Area of steel provided in short direction = 1675 sqmm Steel is Ok

Area of steel required in Long direction


Ast2= (Mh2*10^6)/(δst*j*d) 663 mm2
Top & Bott. Steel Provided in Long direction =
Y 16 @ 120 C/C
Area of steel provided in Long direction = 1675 sqmm Steel is Ok

You might also like