Load From Lift = W2= 0 KN Load From retaining wall = W3= 0 KN Other Loads = W4= 0 KN Self Weight Of Footing = W5= 1574.5 KN Total design load on footing P= 17319.5 KN
SBC of soil = SBC= 150 KN/m2
Required Area of Footing Ao=P/SBC= 115.46 m2 Footing size provided ( Lf x Bf )= 130.45 m2 Net upward press. (total load/A)= Po= 120.70 KN/m2
Max. c/c dist. Of column in short dire. A= 3.0 m
Max. c/c dist. Of column in long dire. B= 2.5 m
Max. Hogging BM in short direction (m1)=
m1= (Po X A2)/10 (Mh1)= 108.63 KN-m Max. Hogging BM in long direction (m2)= m1= (Po X B2)/10 (Mh2)= 75.44 KN-m
Effective depth from max. BM consideration
d=((M max*10^6)/(R*b))^0.5 = 368 mm Provide over all depth of footing = Do= 600 mm Effective depth provided = dy= 550 mm Depth is Ok
CHECK FOR TWO WAY SHEAR (Punching)
Max. load on column = P max= 750 KN
Column provided = (BxD)= 200 X 600 Critical section for two way shear is a peripheral sec. at a distance dy/2 from periphery of the column.
Length of the peripheral critical section at a distance dy/2
from column face L1=D+2*dy/2= D+dy = 1150 mm
Width of the peripheral critical section at a distance dy/2
from column face B1=B+2*dy/2= B+dy = 750 mm
Area resisting shear A2=2(L1+B1)Xdy = 2090000 mm
Shear strength of concrete for two way bending Tuc2 = ks*Tuc where Tuc=0.25(fck)^1/2 for m25 concrete Tuc=0.25*(25)^1/2 = 1.25 N/mm2 ks=1.0 Tuc2= 1.25 N/mm2
Shear strength of concrete for two way bending
Vuc= Tuc2*A2 Vuc= 2612.5 Kn
Design shear Vud =1.5*Po(Lf*Bf - L1*B1)=
5.2 2.2 Vud= 1915 Kn Depth is Ok Since Vud< Vuc Foundation is safe in two way shear
STEEL CALCULATION
Area of steel required in short direction
Ast1= (Mh1*10^6)/(δst*j*d) 954 mm2 Top & Bott. Steel Provided in Short direction = Y 16 @ 120 C/C Area of steel provided in short direction = 1675 sqmm Steel is Ok
Area of steel required in Long direction
Ast2= (Mh2*10^6)/(δst*j*d) 663 mm2 Top & Bott. Steel Provided in Long direction = Y 16 @ 120 C/C Area of steel provided in Long direction = 1675 sqmm Steel is Ok