You are on page 1of 7

DOCUMENT NO.

REV
CODE
Engineering Services
E1121-150-PS-DS-101437_6 1
B Comment Resolution Sheet (CRS)

Owners : EPCM Consultant


Engineering Services

CLIENT GUJARAT ALKALIES AND CHEMICALS Ltd. (GACL)


PLANT EPCM SERVICES FOR 100 KTPA CHLOROMETHANE PLANT AT DAHEJ, GUJARAT
LOCATION DAHEJ, INDIA
Date:04-10-2019
DOC NO : E1121-150-PS-DS-101437_6
Prepared By: KS
Reviewed By: ORG
TITLE : Process datasheet for TC COMPRESSOR SUCTION FILTER (FL-AB1501/A,B,C)
Approved By: MAJ

SR. NO. PAGE NO./Reference CLIENT COMMENTS COMMENTS RESOLUTION CLIENT COMMENTS COMMENTS RESOLUTION

1 5 of 7 Add 'sulphuric acid mist also in note 1 incorporated

2 5 of 7 now it is not in compressor vendor scope incorporated

All exterior carbon steel surfaces are smoothly prepared and


3 5 of 7 incorporated
coated with the anti-corrosive paints in vendor scope

SHEET 1 OF 1
Project No. E-1121

EPCM Services for 100kTPA Chloromethane plant at


Dahej, Gujarat

Project Document Title:


Process Datasheet for
TC COMPRESSOR SUCTION FILTER (FL-AB1501/A,B)

Project Document Number:


E1121-150-PS-DS-101437_6

LTHE Contract Reference Number:


GACL/CPP/100kTPACLM/DE/LOI/01

Customer : GUJARAT ALKALIES AND CHEMICALS Ltd. (GACL)


Technology Supplier : Shin-Etsu Chemicals, Japan
EPC Contractor : -
EPCM Consultant : L&T Hydrocarbon Engineering Ltd.
Engineering Services (AdVENT)

04-Oct-19 2 Re-Issued for Design KS ORG MAJ

10-Aug-19 1 Issued for Design KS MAJ MAJ


20-Mar-19 0 Issued for Information PKB ORG PK
21-Feb-19 B Issued for Approval PP ORG PK
31-Dec-18 A Issued for Review KS ORG PK
Date Rev. Prepared By Checked BY Approved By
Disclaimer:

This document contains confidential and/or proprietary information of LTHE and its affiliated companies. No part of this document,
data, or information, issued for the captioned project or purpose, shall be used for other than the purpose for which this has been
provided or disclosed to others or reproduced in any manner, except with the prior written permission of LTHE.

E1121-150-PS-DS-101437_6_R2 Page 1 of 6
Project Document Title : PROCESS DATASHEET FOR TC
EPCM Services for 100KTPA Chloromethane
COMPRESSOR SUCTION FILTER (FL-AB1501/A,B)
Plant
Doc. No.:E1121-150-PS-DS-101437_6 Rev. 2 04-Oct-19

Issue and Approval Record

Issued Category Approval Code

Engineering Procurement Construction Code A or 1 - Approved


Consent to proceed

Information Enquiry Construction Code B or 2- Comments As Noted


Work may proceed subject to incorporation of comments

Review Purchase Commissioning Code C or 3 - Rejected


Revise and Resubmit. Work shall not proceed

Approval Void As-Built Code D or 4 - Information


Accepted for information only

Is issued Category required approval? Code: Date Approver:

Yes No NA Note: This approval does not relive the document ORIGINATOR any
of his obligations and responsibilities under this Contract .

E1121-150-PS-DS-101437_6_R2 Page 2 of 6
Project Document Title : PROCESS DATASHEET FOR TC
EPCM Services for 100KTPA Chloromethane
COMPRESSOR SUCTION FILTER (FL-AB1501/A,B)
Plant Doc. No.:E1121-150-PS-DS-101437_6 Rev. 2 04-Oct-19

Revision Record

Rev. Date Prepared By Checked By Approved By Revision Note/ Description


A 31-Dec-18 KS ORG PK Issued for Review
B 21-Feb-19 PP ORG PK Issued for Approval
0 20-Mar-19 PKB ORG PK Issued for Information
1 08-Aug-19 KS MAJ MAJ Issued for Design
2 04-Oct-19 KS ORG MAJ Re-Issued for Design
Notes:

• Revised text in Blue colour’ identifies changes in the latest revision of document with revision mark (B,C.. etc) in right
most side of the sheet.
• Revision description A, B, C..... etc. identifies document during development stage for review, approval and enquiry;
Revision description 0,1 ,2…..etc. identifies document if issued for information, or after approval if issued for purchase,
construction, commissioning, etc.

E1121-150-PS-DS-101437_6_R2 Page 3 of 6
EPCM Services for 100KTPA Chloromethane Plant Project Document Title : PROCESS DATASHEET FOR TC COMPRESSOR SUCTION FILTER (FL-AB1501/A,B)

Detailed Engineering Doc. No.:E1121-150-PS-DS-101437_6 Rev. 2 4-Oct-2019

SECTION NO. 1500

CUSTOMER Gujarat Alkalies & Chemicals Ltd. Rev


SERVICE TC Compressor Suction Filter
ITEM NO. FL-AB1501/A,B (Hold-2) NO. REQUIRED 4 (4W)
CONSTRUCTION MATERIALS
WORKING CONDITIONS
JIS standard ASME Equivalent

BODY SHELL SM400B SA 516 Gr. 70


Recycle Gas contains
MATERIAL HANDLED HEAD SM400B SA 516 Gr. 70
Methane, Oxygen,
Nitrogen, Methyl
INSIDE LINING
Chloride, Methylene
Chloride, Chloroform and JACKET
Carbon Tetra Chloride
CAPACITY 4500 Nm3/h NOZZLE STPG370 SA 106 Gr.B

WORKING PRESS. 0.15 kg/cm2G GASKET PACKING T/#9007LC Silica Filled PTFE

INTERNAL PARTS

SA 516 Gr.70 (Directly welded) /


WORKING TEMP. 40.0 ℃ SKIRT/SUDDLE
IS 2062 (Not welded directly)

DENSITY 2.21 kg/Nm3

CORROSIVITY NO

VAPOR PRESS. ANCILLARY PARTS

VISCOSITY 0.013 cP at 40℃ 1) Lug & Davit (SS400)

SLURRY NO 2) Bolts/Nuts for nozzle flanges and anchor bolts

DESIGN DATA 3) Deleted.

TYPE Vertical, Cylindrical 4) Deleted.

VOLUME DESIGNED - m3 5) Differential pressure gauge with gauge valves

MAX. OPERATION - m3

BODY NOZZLE LIST (Note-5)

DESIGN PRESS. 2.0 kg/cm2G MAT'L


MARK SIZE Q'TY RATING SERVICE Remarks
JIS ASME EQUIVALENT

DESIGN TEMP. 60.0 ℃ A 250 1 STPG370 SA 105 150# Vapor Inlet

B 250 1 STPG370 SA 105 150# Vapor Outlet

CORROSION ALLOW. In 1mm / Out 1mm C 50 1 STPG370 SA 105 150# Drain

HYDR'C As Per Code


TEST
PRESS. PNEUM'C As Per Code P1,2 50 2 STPG370 SA 105 150# PdG

RADIOGRAPHIC EX. YES

STRESS RELIEVING NO

BUFFING NO

ACID PICKLING NO

PAINTING CARBON STEEL PARTS (NOTE-2)

HEAT INSULATION NO

INSIDE FINISHING NO

LOCATION OUTDOOR

Notes:

1 Purpose: To remove mainly iron chloride and foreign matters and sulphuric acid mist. 2

2 All exterior carbon steel surfaces are smoothly prepared and coated with the anti-corrosive paints by vendor . 2

3 Deleted 2

4 Earth lug shall be provided for Filter.

5 All nozzles -top, side and bottom shall be of minimum 150 mm length unless otherwise specified.

6 Lifting lug & Davit shall be provided by vendor.

7 All dimensions given in unit is in "mm" unless otherwise specified.


8 (*) Vendor to confirm.
9 Collection efficiency shall be minimum 99% ( mist Dia: less than 3μm ) 2

10 Allowable pressure drop across suction filter shall be 50 mmAq maximum 2

11 I.D. & TL to TL length of the vessel given is preliminary and it shall be confirmed by vendor. 2

12 FL-AB1501C is warehouse spare, shall be decided by Client . 2

E1121-150-PS-DS-101437_6_R2 Page 4 of 6
EPCM Services for 100KTPA Chloromethane Plant Project Document Title : PROCESS DATASHEET FOR TC COMPRESSOR SUCTION FILTER (FL-AB1501/A,B)

Detailed Engineering Doc. No.:E1121-150-PS-DS-101437_6 Rev. 2 4-Oct-2019

SECTION NO. 1500

CUSTOMER Gujarat Alkalies & Chemicals Ltd. Rev


SERVICE TC Compressor Suction Filter
ITEM NO. FL-AB1501/A,B (Hold-2) NO. REQUIRED 4 (4W)

CONSTRUCTION MATERIALS
WORKING CONDITIONS SKETCH

(*)

(*)

Size: ID1200×3450L(F-TL)(*)

E1121-150-PS-DS-101437_6_R2 Page 5 of 6
EPCM Services for 100KTPA Chloromethane Plant Project Document Title : PROCESS DATASHEET FOR TC COMPRESSOR SUCTION FILTER (FL-AB1501/A,B)

Detailed Engineering Doc. No.:E1121-150-PS-DS-101437_6 Rev. 2 4-Oct-2019

SECTION NO. 1500

CUSTOMER Gujarat Alkalies & Chemicals Ltd. Rev


SERVICE TC Compressor Suction Filter
ITEM NO. FL-AB1501/A,B (Hold-2) NO. REQUIRED 4 (4W)

CONSTRUCTION MATERIALS
WORKING CONDITIONS SKETCH

E1121-150-PS-DS-101437_6_R2 Page 6 of 6

You might also like