You are on page 1of 2

Design hydrostatics report

Design hydrostatics report


11m hull JMN
Designer Jean-Marc NOURRY
Created by Jean-Marc NOURRY
Comment CRANA Organisation Modeller
Filename 11m Hull JMN.fbm
Design length 11,401 (m) Midship location 5,701 (m)
Length over all 11,401 (m) Relative water density 1,0250
Design beam 3,178 (m) Mean shell thickness 0,0000 (m)
Maximum beam 3,177 (m) Appendage coefficient 1,0000
Design draft 0,353 (m)

Volume properties Waterplane properties


Moulded volume 3,498 (m3) Length on waterline 10,311 (m)
Total displaced volume 3,498 (m3) Beam on waterline 2,313 (m)
Displacement 3,585 (tonnes) Entrance angle 54,953 (Degr.)
Block coefficient 0,4155 Waterplane area 17,179 (m2)
Prismatic coefficient 0,5803 Waterplane coefficient 0,7203
Vert. prismatic coefficient 0,5768 Waterplane center of floatation 5,151 (m)
Wetted surface area 18,611 (m2) Transverse moment of inertia 5,528 (m4)
Longitudinal center of buoyancy 5,464 (m) Longitudinal moment of inertia 106,73 (m4)
Longitudinal center of buoyancy -2,297 %
Vertical center of buoyancy 0,225 (m)
Total length of submerged body 10,311 (m)
Total beam of submerged body 2,313 (m)

Midship properties Initial stability


Midship section area 0,585 (m2) Transverse metacentric height 1,805 (m)
Midship coefficient 0,7160 Longitudinal metacentric height 30,742 (m)

Lateral plane
Lateral area 2,427 (m2)
Longitudinal center of effort 6,014 (m)
Vertical center of effort 0,212 (m)

The following layer properties are calculated for both sides of the ship
Location Area Thickness Weight LCG TCG VCG
2
(m ) (m) (tonnes) (m) (m) (m)
Layer 0 42,671 0,000 0,000 5,441 0,000 (CL) 0,497

Sectional areas
Location Area Location Area Location Area Location Area Location Area
(m) (m 2) (m) (m 2) (m) (m 2) (m) (m 2) (m) (m 2)
11,401 0,000 8,901 0,217 6,401 0,542 3,901 0,537 1,401 0,098
10,901 0,006 8,401 0,291 5,901 0,576 3,401 0,479 0,901 0,003
10,401 0,036 7,901 0,364 5,401 0,594 2,901 0,403 0,401 0,000
9,901 0,084 7,401 0,432 4,901 0,595 2,401 0,311
9,401 0,147 6,901 0,493 4,401 0,575 1,901 0,206

7.09.2020 1
Design hydrostatics report

Sectional areas
0,60

0,55

0,50

0,45

0,40

0,35
Area (m2)

0,30

0,25

0,20

0,15

0,10

0,05

0,00

1 2 3 4 5 6 7 8 9 10 11

Location (m)

NOTE 1: Draft (and all other vertical heights) is measured from base Z=0,000
NOTE 2: All calculated coefficients based on actual dimensions of submerged body.

7.09.2020 2