GENERAL CONSTRUCTION NOTES VICINITY MAP DRAWING INDEX Revision/Issue Date

T1 TITLE SHEET
THIS PROJECT SHALL COMPLY WITH 2016 CALIFORNIA RESIDENTIAL CODE (CRC), CALIFORNIA G1 2016 CALIFORNIA GREEN BUILDING STANDARDS
MECHANICAL CODE (CMC), CALIFORNIA PLUMBING CODE (CPC), CALIFORNIA ELECTRICAL CODE (CEC),
G2 CMC CONSTRUCTION BEST MANAGEMENT PRACTICES & GEN. NOTES
CALIFORNIA FIRE CODE (CFC), CALIFORNIA ENERGY CODE (CENC) & CALIFORNIA GREEN BUILDING CODE
(CALGREEN).
ARCHITECTURAL
THESE DRAWINGS ARE PREPARED FOR USE BY A PROPERLY LICENSED AND CERTIFIED CONTRACTOR. A1 SITE & ROOF PLANS
ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE CODE AND ORDINANCE REQUIREMENTS A1.2 DRAINAGE PLAN
SET FORTH BY THE PREVAILING GOVERNING BODY. A1.3 EROSION & SEDIMENT CONTROL PLAN

DESIGN@HASTINGSCONSTRUCTION.COM | LIC#: 791539


A2 PROPOSED ENTRY & LOWER LEVEL FLOOR PLANS

HASTINGS CONSTRUCTION, INC.


CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, MATERIALS, AND CONDITIONS PRIOR TO
STARTING CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE DESIGNER PRIOR TO ORDERING A3 EXTERIOR ELEVATIONS
MATERIALS. A4 ARCHITECTURAL DETAILS

316 MID VALLEY CENTER | SPACE 161


CARMEL, CA 93923 | (831) 620-0920
CONTRACTOR TO PROTECT EXISTING CONDITIONS FROM DAMAGE, DUST, AND DEBRIS. MATERIALS
PLANNED TO BE REUSED ARE TO BE PROTECTED FROM DAMAGE THROUGHOUT THE DEMOLITION
PROCESS. CONTRACTOR IS RESPONSIBLE FOR COMPLETE FINAL DISPOSAL OF ALL CONSTRUCTION
DEBRIS IN A MANNER CONSISTENT WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS.
SCOPE OF WORK
CONTRACTOR TO PROVIDE OWNER MANUALS FOR ALL NEWLY INSTALLED APPLIANCES AND DEVICES
SUCH AS: HEATING & COOLING SYSTEMS, LIGHTING, SECURITY SYSTEMS, ETC.
MINOR DESIGN STUDY - TRACK 2; AMENDMENT TO APPROVED STUDY ORIGINALLY
ALL WRITTEN DIMENSIONS SHALL SUPERCEDE SCALED DIMENSIONS. DRAWN BY BRIAN CONGLETON AIA, PERMIT# 17-011 RV 01
VERIFY LOCATION OF UTILITIES AND EXISTING CONDITIONS AT THE SITE PRIOR TO CONSTRUCTION.
REVISION TO INCLUDE THE FOLLOWING:
INSTALLATION OF ALL LISTED EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURERS
SPECIFICATIONS AND SHALL BE PROVIDED TO THE FIELD INSPECTOR AT HE TIME F INSPECTION PER - Propose new 212 square foot Family Room addition at rear of residence with
CMC 303.1
new 237 square foot permeable Ipe deck with powder coated metal railing.
Deferred submittals: -New 10'-0" x 7'-0" Bi-fold door system
in accordance with the City of Carmel-by-the-sea's deferred submittal agreement, if
requested, the following submittal(s) shall be approved by the building official prior to JOBSITE - 3 new windows (to match approved)
work commencement:
- fire sprinklers LOCATION -New gas fireplace
N - All exterior finishes shall match previously approved residence.

PROJECT DATA
OWNER DESIGNER
Peter & Susan Loewy Angie Phares
SYMBOL KEY APN MAP 1 Oak Meadow Lane Hastings Construction, Inc.
Carmle, CA 93924 316 Mid Valley Center, Space 161
650-464-6862 Carmel, CA 93923
JOBSITE ploewy@peterloewy.com 831-620-0920
SECTION TAG PLAN CHECK LOCATION zakanaka@comcast.net design@hastingsconstruction.com
SECTION NUMBER/LETTER 1 REVISION NUMBER
a
BUILDING DATA:
a1 SHEET NUMBER Construction Type: VB
Fire Sprinklers: YES

LOT DATA:

MISSION 2 SW FIRST, CARMEL-BY-THE-SEA, CALIFORNIA


APN: 010-121-021-000 BLOCK: 11, LOT 7
PARCEL SIZE: 4,000 sq. ft.(0.09062 ACRES)
ZONING: R-1

ABBREVIATIONS SITE COVERAGE:


Previously Approved:
A.B. ANCHOR BOLT F.O.C. FACE OF CONCRETE O.C. ON CENTER TYP. TYPICAL
A.C. ASPHALTIC CONCRETE F.O.S. FACE OF STUD O.F.S. OUTSIDE FACE OF STUD Driveway (permeable) 167.7 sq. ft.
A/C AIR CONDITIONING FR. DR. FRENCH DOOR OPP. OPPOSITE U.N.O. UNLESS NOTED OTHERWISE
ALUM. ALUMINUM FT. FOOT OR FEET O.A. OUTSIDE DIAMETER Steps, Walls, Landings (impervious) 94.4 sq. ft.
APPROX. APPROXIMATE FTG. FOOTING VERT. VERTICAL
ARCH. ARCHITECTURAL ⅊ PLATE Walkways (permeable) 57.2 sq. ft.
ANOD. ANODIZED GA GAUGE P/L PROPERTY W/ WITH
ASPH. ASPHALT GALV. GALVANIZED PLAS. PLASTER WAINS WAINSCOT Total Permeable 222.9 sq. ft.
G.I. GALVANIZED IRON PLY. PLYWOOD WC WATER CLOSET
BD. BOARD GFI GROUND FAULT PNL. PANEL WD WOOD Total Coverage 317.3 sq. ft.
BLDG. BUILDING INTERRUPTER P&S POLE & SHELF WDW WINDOW
BLKG. BLOCKING GL GLASS PT. POINT W/O WITH OUT
BM. BEAM GND. GROUND PR. PAIR WP WATERPROOF
Proposed:

MISSION STREET RESIDENCE


BOTT. BOTTOM GYP. BD. GYPSUM BOARD WWP WELDED WIRE FABRIC

CAB. CABINET H.C. HOLLOW CORE


R.A.
RAD.
RETURN AIR
RADIUS Driveway (permeable) 167.7 sq. ft. (unchanged)
CEM.
C.T.
CEMENT
CERAMIC TILE
H.D.
HDR.
HOLD DOWN
HEADER
RD.
REC.
ROUND
RECESSED
Steps, Walls, Landings (impervious) 80.2 sq. ft. (rear stoop removed)
C.I.
CLR.
CAST IRON
CLEAR
HDWD.
HORIZ.
HARDWOOD
HORIZONTAL
REF.
RENF.
REFRIGERATOR
REINFORCED/ING
Walkways (permeable) 57.2 sq. ft. (unchanged)
CLST.
COMP.
CLOSET
COMPOSITION
HR.
H.B.
HOUR
HOSE BIBB
RES.
RM.
RESILIENT
ROOM
New Deck (permeable) 237 sq. ft.
CONC.
CLG.
CONCRETE
CEILING
HT.
HC.
HEIGHT
HANDICAP
R.O.
REQ.
ROUGH OPENING
REQUIRED
Total Permeable 461.9 sq. ft.

APN: 010-121-021
C.M.U.
C.O.
CONCRETE MASONRY UNIT
CLEAN OUT
HVAC HEATING VENTILATION &
AIR CONDITIONING
R/W
RWD.
RIGHT OF WAY
REDWOOD
Total 542.1 sq. ft.
COL.
CONN.
COLUMN
CONNECTION
HW HOT WATER R.W.L. RAINWATER LEADER Total Allowed 556 sq. ft.

Project Address & APN:


CONST. CONSTRUCTION I.D. INSIDE DIAMETER SCHED. SCHEDULE

TITLE SHEET
CSMT. CASEMENT INS. INSULATION S.C. SOLID CORE
C.W. COLD WATER INT. INTERIOR SECT. SECTION
S.F. SQUARE FOOT/FEET
DBL. DOUBLE J.B. JUNCTION BOX SH SINGLE HUNG FLOOR AREA:

Drawing Title:
DET.
DF.
DETAIL
DOUGLAS FIR
JST. JOIST SHT.
SHWR.
SHEET
SHOWER Previously Approved:
KIT. KITCHEN SIM. SIMILAR
Entry Level 784 sq. ft.

Job Title:
DIA. OR Ø DIAMETER
DIM. DIMENSION KP KICKER POST SLD SLIDER
D.S.
DRY
DOWNSPOUT
DRYER
KS KING STUD SLD. GL. DR.SLIDING GLASS DOOR
SPECS. SPECIFICATIONS
Lower Level/Garage 748 sq. ft.
DW
DWG
DISHWASHER
DRAWING
LAV
LIN.
LAVATORIES
LINEN
SQ.
SQ.FT.
SQUARE
SQUARE FEET
Total 1,532 sq. ft.
LT. LIGHT STD. STANDARD
EA. EACH STL. STEEL
ELEC. ELECTRICAL MAT.
MAX.
MATERIAL
MAXIMUM
STOR. STORAGE Proposed: Sheet
ELEV. ELEVATION STRUCT. STRUCTURAL Project:
ENCL. ENCLOSURE M.B.
MECH.
MACHINE BOLT
MECHANICAL
SS STAINLESS STEEL Entry Level 996 sq. ft. HC1754
EQ EQUAL SYM. SYMMETRICAL
EXH. EXHAUST M.A. MEDICINE CABINET Lower Level/Garage 748 sq. ft. (reduced) Date:
MFR. MANUFACTURER

T1
EXP. EXPANSION TB TOWEL BAR
EXIST. OR (E) EXISTING MIN. MINIMUM TEL. TELEPHONE Total 1,744 sq. ft. 12/12/2019
EXT. EXTERIOR MISC. MISCELLANEOUS TEMP. TEMPERED
MTD. MOUNTED THRSH. THRESHOLD Total Allowed 1800 sq. ft. Drawn By:
FBRGL. FIBERGLASS T&G TONGUE & GROOVE
FD FLOOR DRAIN (N) NEW T.O.F. TOP OF FOOTING
FND. FOUNDATION N.I.C. NOT N CONTRACT T.O. TOP OF AAP
F.F. FINISH FLOOR NO. OR # NUMBER T.O.P. TOP OF PLATE Scale:
F.G. FINISH GRADE N.T.S. NOT TO SCALE T.O.S. TOP OF SLAB
FLR. FLOOR T.O.W. TOP OF WALL 1/8"=1'-0"
FL. FLUORESCENT O/ OVER TP TOILET PAPER
2016 GREEN BUILDING STANDARDS CODE
Revision Issue Date
4. Meet the California Department of Public Health, Standard Method for the Testing and Evaluation
CHAPTER 3 referenced in Table 1701.1 of the California Plumbing Code. 4.502.1 Definitions. TABLE 4.504.1 of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,
GREEN BUILDING ADHESIVE VOC LIMIT 1, 2 Version 1.1, February 2010 (also known as Specification 01350).
SECTION 4.304 OUTDOOR WATER USE AGRIFIBER PRODUCTS: Agrifiber products include wheatboard, strawboard, Less Water and Less Exempt Compounds in Grams per Liter
4.304.1 Outdoor potable water use in landscape areas. After December 1, 2015, new panel substrates and door cores, not including furniture, fixtures and
SECTION 301 GENERAL 4.504.5 Composite wood products. Hardwood plywood, particleboard and medium density fiberboard
residential developments with an aggregate landscape area equal to or greater than equipment (FF E) not considered base building elements. ARCHITECTURAL APPLICATIONS VOC LIMIT
301.1 Scope. Buildings shall be designed to include the green building measures specified composite wood products used on the interior or exterior of the building shall meet the requirements for
500 square feet shall comply with one of the following options:
as mandatory in the application checklists contained in this code. Voluntary green formaldehyde as specified in ARB s Air Toxics Control Measure for Composite Wood (17 CCR 3120 et seq.),
1. A local water efficient landscape ordinance or the current California COMPOSITE WOOD PRODUCTS: Composite wood products include hardwood Indoor carpet adhesives 50
building measures are also included in the application checklists and may be included by or before the dates specified in those sections, as shown in Table 4.504.5.
Department of Water Resources Model Water Efficient Landscape Ordinance plywood, particleboard and medium density fiberboard. Composite wood Carpet pad adhesives 50
in the design and construction of structures covered by this code, but are not required
(MWELO), whichever is more stringent or 2. Pro ects with aggregate landscape products does not include hardboard, structural plywood, structural panels, Outdoor carpet adhesives 150
unless adopted by a city, county, or city and county as specified in Section 101.7. 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the
areas less than 2,500 square feet may comply with the MWELO s Appendix D structural composite lumber, oriented strand board, glued laminated timber, Wood flooring adhesive 100 enforcing agency. Documentation shall include at least one of the following:
Prescriptive Compliance Option. prefabricated wood I- oists or finger ointed lumber, all as specified in California Rubber floor adhesives 60
301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 1. Product certifications and specifications.
Notes: 1. The Model Water Efficient Landscape Ordinance (MWELO) and Code of Regulations (CCR), Title 17, Section 3120.1(a). Note: See CCR, Title 17,
shall be applied to additions or alterations of existing residential buildings where Subfloor adhesives 50 2. Chain of custody certifications.
supporting documents are available at: Section 3120.1
the addition or alteration increases the building s conditioned area, volume, or Ceramic tile adhesives 65 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17,
http: www.water.ca.gov wateruseefficiency landscapeordinance
si e. The requirements shall apply only to and or within the specific area of the VCT and asphalt tile adhesives 50 Section 3120, et seq.).
2. A water budget calculator is available at: http: DIRECT-VENT APPLIANCE: A fuel-burning appliance with a sealed combustion
addition or alteration. Drywall and panel adhesives 50 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood

DESIGN HASTINGSCONSTRUCTION.COM LIC : 7 153


system that draws all air for combustion from the outside atmosphere and

HASTINGS CONSTRUCTION, INC.


www.water.ca.gov wateruseefficiency landscapeordinance
Note: On and after anuary 1, 2014, residential buildings undergoing permitted Cove base adhesives 50 Association, the Australian AS N S 226 , European 636 3S, and Canadian CSA O121, CSA O151, CSA
discharges all flue gases to the outside atmosphere.
alterations, additions or improvements shall replace noncompliant plumbing Multipurpose construction adhesives 70 O153 and CSA O325 standards.
fixtures with water-conserving plumbing fixtures. Plumbing fixture Division 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY MAXIMUM INCREMENTAL REACTIVITY (MIR): The maximum change in Structural gla ing adhesives 100 5. Other methods acceptable to the enforcing agency.
replacement is required prior to issuance of a certificate of final completion, Single-ply roof membrane adhesives 250

316 MID VALLEY CENTER SPACE 161


weight of o one formed by adding a compound to the Base Reactive Organic

CARMEL, CA 3 23 (831) 620-0 20


certificate of occupancy or final permit approval by the local building SECTION 4.401 GENERAL Gas (ROG) Mixture per weight of compound added, expressed to hundredths Other adhesives not specifically listed 50 TABLE 4.504.5
department. See Civil Code Section 1101.1, et seq., for the definition of a 4.401.1 Scope. The provisions of this chapter shall outline means of achieving material FORMALDEHYDE LIMITS 1
of a gram (g O3 g ROC). Note: MIR values for individual compounds and
noncompliant plumbing fixture, types of residential buildings affected and conservation and resource efficiency through protection of buildings from exterior SPECIALTY APPLICATIONS Maximum Formaldehyde Emissions in Parts per Million
hydrocarbon solvents are specified in CCR, Title 17, Sections 4700 and 4701.
other important enactment dates. moisture construction waste diversion employment of techniques to reduce
pollution through recycling of materials and building commissioning or testing, MOISTURE CONTENT: The weight of the water in wood expressed in PVC welding 510 PRODUCT CURRENT LIMIT
301.2 Low-rise and high-rise residential buildings. [HCD] The provisions of individual ad usting and balancing. CPVC welding 4 0
percentage of the weight of the oven-dry wood.
sections of CALGreen may apply to either low-rise residential buildings, high-rise ABS welding 325 Hardwood plywood veneer core 0.05
residential buildings, or both. Individual sections will be designated by banners to SECTION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE Plastic cement welding 250 Hardwood plywood composite core 0.05
PRODUCT-WEIGHTED MIR (PWMIR): The sum of all weighted-MIR for all
indicate where the section applies specifically to low-rise only (LR) or high-rise only 4.406.1 Rodent proofing. Annular spaces around pipes, electric cables, conduits or Adhesive primer for plastic 550 Particleboard 0.0
ingredients in a product sub ect to this article. The PWMIR is the total product
(HR). When the section applies to both low-rise and high-rise buildings, no banner other openings in sole bottom plates at exterior walls shall be protected against the reactivity expressed to hundredths of a gram of o one formed per gram of Contact adhesive 80 Medium density fiberboard 0.11
will be used. passage of rodents by closing such openings with cement mortar, concrete masonry product (excluding container and packaging). Note: PWMIR is calculated Special purpose contact adhesive 250 Thin medium density fiberboard2 0.13
or a similar method acceptable to the enforcing agency. according to equations found in CCR, Title 17, Section 4521(a). Structural wood member adhesive 140
CHAPTER 4 Top and trim adhesive 250
1. Values in this table are derived from those specified by the California Air Resources
Board, Air Toxics Control Measure for Composite Wood as tested in accordance with
RESIDENTIAL MANDATORY MEASURES SECTION 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING REACTIVE ORGANIC COMPOUND (ROC): Any compound that has the ASTM E1333. For additional information, see California Code of Regulations, Title 17,
Division 4.1 PLANNING AND DESIGN 4.408.1 Construction waste management . Recycle and or salvage for reuse a minimum potential, once emitted, to contribute to o one formation in the troposphere. SUBSTRATE SPECIFIC APPLICATIONS Sections 3120 through 3120.12.
of 65 percent of the nonha ardous construction and demolition waste in accordance 2. Thin medium density fiberboard has a maximum thickness of 5 16 inch (8 mm).
SECTION 4.101 GENERAL with either Section 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local VOC: A volatile organic compound (VOC) broadly defined as a chemical Metal to metal 30
construction and demolition waste management ordinance. SECTION 4.505
4.101.1 Scope. The provisions of this division outline planning, design and development compound based on carbon chains or rings with vapor pressures greater than Plastic foams 50 INTERIOR MOISTURE CONTROL
methods that include environmentally responsible site selection, building design, Exceptions: 0.1 millimeters of mercury at room temperature. These compounds typically Porous material (except wood) 50
1. Excavated soil and land-clearing debris. 4.505.1 General. Buildings shall meet or exceed the provisions of the California Building Standards Code.
building siting and development to protect, restore and enhance the environmental contain hydrogen and may contain oxygen, nitrogen and other elements. See Wood 30
quality of the site and respect the integrity of ad acent properties. 2. Alternate waste reduction methods developed by working with local agencies CCR Title 17, Section 4508(a). Fiberglass 80 4.505.2 Concrete slab foundations. Concrete slab foundations required to have a vapor retarder by the
if diversion or recycle facilities capable of compliance with this item do not Note: Where specific regulations are cited from different agencies, such as
exist or are not located reasonably close to the obsite. California Building Code, Chapter 1 or concrete slab-on-ground floors required to have a vapor retarder by
SECTION 4.102 DEFINITIONS South Coast Air Quality Management District (SCAQMD), California Air 1. If an adhesive is used to bond dissimilar substrates together, the adhesive with the highest the California Residential Code, Chapter 5, shall also comply with this section.
4.102.1 Definitions. 3. The enforcing agency may make exceptions to the requirements of this section Resources Board (ARB or CARB), etc., the VOC definition included in that VOC content shall be allowed.
when isolated obsites are located in areas beyond the haul boundaries of the specific regulation is the one that prevails for the specific measure in 2. For additional information regarding methods to measure the VOC content specified in this
diversion facility. 4.505.2.1 Capillary break. A capillary break shall be installed in compliance with at least one of the
FRENCH DRAIN: A trench, hole or other depressed area loosely filled with rock, question. table, see South Coast Air Quality Management District Rule 1168.
following:
gravel, fragments of brick or similar pervious material used to collect or
4.408.2 Construction waste management plan. Submit a construction waste 1. A 4-inch-thick (101.6 mm) base of 1 2 inch (12.7 mm) or larger clean aggregate shall be provided with a
channel drainage or runoff water. SECTION 4.503 FIREPLACES TABLE 4.504.3
management plan in conformance with Items 1 through 5. The construction waste vapor retarder in direct contact with concrete and a concrete mix design, which will address bleeding,
4.503.1 General. Any installed gas fireplace shall be a directvent sealed-combustion VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS 2, 3
shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, ACI
WATTLES: Wattles are used to reduce sediment in runoff. Wattles are often management plan shall be updated as necessary and shall be available during type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source
construction for examination by the enforcing agency. Grams of VOC per Liter of Coating, 302.2R-06.
constructed of natural plant materials such as hay, straw or similar material Performance Standards (NSPS) emission limits as applicable, and shall have a
1. Identify the construction and demolition waste materials to be diverted from Less Water and Less Exempt Compounds 2. Other equivalent methods approved by the enforcing agency.
shaped in the form of tubes and placed on a downflow slope. Wattles are also permanent label indicating they are certified to meet the emission limits.
disposal by recycling, reuse on the pro ect or salvage for future use or sale. 3. A slab design specified by a licensed design professional.
used for perimeter and inlet controls. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local
2. Specify if construction and demolition waste materials will be sorted on-site COATING CATEGORY VOC LIMIT
ordinances. 4.505.3 Moisture content of building materials. Building materials with visible signs of water damage shall
SECTION 4.106 SITE DEVELOPMENT (source-separated) or bulk mixed (single stream).
Flat coatings 50 not be installed. Wall and floor framing shall not be enclosed when the framing members exceed
4.106.1 General. Preservation and use of available natural resources shall be 3. Identify diversion facilities where the construction and demolition waste SECTION 4.504 POLLUTANT CONTROL
Nonflat coatings 100 1 -percent moisture content. Moisture content shall be verified in compliance with the following:
accomplished through evaluation and careful planning to minimi e negative effects material will be taken. 4.504.1 Covering of duct openings and protection of mechanical equipment during
Nonflat-high gloss coatings 150 1. Moisture content shall be determined with either a probe-type or contact-type moisture meter.
on the site and ad acent areas. Preservation of slopes, management of storm water 4. Identify construction methods employed to reduce the amount of construction construction. At the time of rough installation, during storage on the construction Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy
drainage and erosion controls shall comply with this section. and demolition waste generated. site and until final startup of the heating, cooling and ventilating equipment, all duct
SPECIALTY COATINGS requirements found in Section 101.8 of this code.
5. Specify that the amount of construction and demolition waste materials and other related air distribution component openings shall be covered with tape,
diverted shall be calculated by weight or volume, but not by both. 2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (121 mm) from the grade
4.106.2 Storm water drainage and retention during construction. Pro ects which plastic, sheetmetal or other methods acceptable to the enforcing agency to reduce
disturb less than one acre of soil and are not part of a larger common plan of Aluminum roof coatings 400 stamped end of each piece to be verified.
the amount of water, dust and debris, which may enter the system. 3. At least three random moisture readings shall be performed on wall and floor framing with
development which in total disturbs one acre or more, shall manage storm water 4.408.3 Waste management company. Utili e a waste management company, Basement specialty coatings 400
drainage during construction. In order to manage storm water drainage during approved by the enforcing agency, which can provide verifiable documentation that Bituminous roof coatings 50 documentation acceptable to the enforcing agency provided at the time of approval to enclose the
4.504.2 Finish material pollutant control. Finish materials shall comply with this wall and floor framing.
construction, one or more of the following measures shall be implemented to the percentage of construction and demolition waste material diverted from the section. Bituminous roof primers 350
prevent flooding of ad acent property, prevent erosion and retain soil runoff on the landfill complies with Section 4.408.1. Bond breakers 350
Note: The owner or contractor may make the determination if the construction and Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to
site. 4.504.2.1 Adhesives, sealants and caulks. Adhesives, sealants and caulks used on Concrete curing compounds 350
demolition waste materials will be diverted by a waste management company. dry prior to enclosure in wall or floor cavities. Wet-applied insulation products shall follow the
1. Retention basins of sufficient si e shall be utili ed to retain storm water on the the pro ect shall meet the requirements of the following standards unless more Concrete masonry sealers 100
site. manufacturers drying recommendations prior to enclosure.
stringent local or regional air pollution or air quality management district rules Driveway sealers 50
2. Where storm water is conveyed to a public drainage system, collection point, 4.408.4 Waste stream reduction alternative [LR]. Pro ects that generate a total apply: Dry fog coatings 150 SECTION 4.506
gutter or similar disposal method, water shall be filtered by use of a barrier combined weight of construction and demolition waste disposed of in landfills, which 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant Faux finishing coatings 350 INDOOR AIR QUALITY AND EXHAUST
system, wattle or other method approved by the enforcing agency. do not exceed 3.4 pounds per square foot of the building area shall meet the primers, and caulks shall comply with local or regional air pollution control or Fire resistive coatings 350 4.506.1 Bathroom exhaust fans. Each bathroom shall be mechanically ventilated and shall comply with the
3. Compliance with a lawfully enacted storm water management ordinance. minimum 65 percent construction waste reduction requirement in Section 4.408.1 air quality management district rules where applicable or SCAQMD Rule 1168 Floor coatings 100 following:
VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. Such products Form-release compounds 250 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building.
Division 4.2 ENERGY EFFICIENCY 4.408.4.1 Waste stream reduction alternative. Pro ects that generate a total combined also shall comply with the Rule 1168 prohibition on the use of certain toxic Graphic arts coatings (sign paints) 500
weight of construction and demolition waste disposed of in landfills, which do not 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a
compounds (chloroform, ethylene dichloride, methylene chloride, High temperature coatings 420 humidity control.
SECTION 4.201 GENERAL exceed 2 pounds per square foot of the building area, shall meet the minimum perchloroethylene and trichloroethylene), except for aerosol products, as Industrial maintenance coatings 250 a. Humidity controls shall be capable of ad ustment between a relative humidity range of 50 percent

MISSION 2 SW FIRST, CARMEL-BY-THE-SEA, CALIFORNIA


4.201.1 Scope. For the purposes of mandatory energy efficiency standards in this code, the 65-percent construction waste reduction requirement in Section 4.408.1. specified in Subsection 2 below. Low solids coatings1 120 to a maximum of 80 percent. A humidity control may utili e manual or automatic means of
California Energy Commission will continue to adopt mandatory standards. 2. Aerosol adhesives, and smaller unit si es of adhesives, and sealant or caulking Magnesite cement coatings 450 ad ustment.
4.408.5 Documentation. Documentation shall be provided to the enforcing agency compounds (in units of product, less packaging, which do not weigh more than
Division 4.3 WATER EFFICIENCY AND CONSERVATION which demonstrates compliance with Section 4.408.2, Items 1 through 5, Section Mastic texture coatings 100 b. A humidity control may be a separate component to the exhaust fan and is not required to be
1 pound and do not consist of more than 16 fluid ounces) shall comply with Metallic pigmented coatings 500 integral (i.e., built-in).
4.408.3 or Section 4.408.4. statewide VOC standards and other requirements, including prohibitions on
SECTION 4.301 GENERAL Notes: Multicolor coatings 250 Notes:
use of certain toxic compounds, of California Code of Regulations, Title 17, Pretreatment wash primers 420 1. For the purposes of this section, a bathroom is a room which contains a bathtub, shower, or tub shower
4.301.1 Scope. The provisions of this chapter shall establish the means of conserving 1. Sample forms found in A Guide to the California Green Building Standards Code commencing with Section 4507. Primers, sealers, and undercoaters 100 combination.
water used indoors, outdoors and in wastewater conveyance. (Residential) located at www.hcd.ca.gov CALGreen.html may be used to assist in
documenting compliance with this section. Reactive penetrating sealers 350 2. Lighting integral to bathroom exhaust fans shall comply with the California Energy Code.
4.504.2.2 Paints and coatings. Architectural paints and coatings shall comply with
SECTION 4.303 INDOOR WATER USE 2. Mixed construction and demolition debris (C D) processors can be located at the Recycled coatings 250
VOC limits in Table 1 of the ARB Architectural Suggested Control Measure, as SECTION 4.507 ENVIRONMENTAL COMFORT
4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures (water California Department of Resources Recycling and Recovery (CalRecycle). Roof coatings 50
shown in Table 4.504.3, unless more stringent local limits apply. The VOC content 4.507.2 Heating and air-conditioning system design. Heating and air-conditioning systems shall be si ed,
closets and urinals) and fittings (faucets and showerheads) shall comply with the Rust preventative coatings 250
limit for coatings that do not meet the definitions for the specialty coatings designed and have their equipment selected using the following methods:
following: SECTION 4.410 BUILDING MAINTENANCE AND OPERATION Shellacs
categories listed in Table 4.504.3 shall be determined by classifying the coating as 1. The heat loss and heat gain is established according to ANSI ACCA 2 Manual 2011 (Residential Load
4.410.1 Operation and maintenance manual. At the time of final inspection, a manual, Clear 730
a Flat, Nonflat or Nonflat-high Gloss coating, based on its gloss, as defined in Calculation), ASHRAE handbooks or other equivalent design software or methods.
4.303.1.1 Water closets. The effective flush volume of all water closets shall not compact disc, web-based reference or other media acceptable to the enforcing Opaque 550
subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources Board,

2016 CAL GREEN BUILDING STANDARDS


exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the agency which includes all of the following shall be placed in the building: Specialty primers, sealers undercoaters 100 2. Duct systems are si ed according to ANSI ACCA 1 Manual D 2014 (Residential Duct Systems),
Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-high ASHRAE handbooks or other equivalent design software or methods.
performance criteria of the U.S. EPA WaterSense Specification for Tank-type 1. Directions to the owner or occupant that the manual shall remain with the Stains 250
Gloss VOC limit in Table 4.504.3 shall apply. 3. Select heating and cooling equipment according to ANSI ACCA 3 Manual S 2014 (Residential
Toilets. building throughout the life cycle of the structure. Stone consolidants 450
Note: The effective flush volume of dual flush toilets is defined as the 2. Operation and maintenance instructions for the following: Swimming pool coatings 340 Equipment Selection) or other equivalent design software or methods. Exception: Use of alternate
4.504.2.3 Aerosol paints and coatings. Aerosol paints and coatings shall meet the design temperatures necessary to ensure the systems function are acceptable.
composite, average flush volume of two reduced flushes and one full flush. a. Equipment and appliances, including water-saving devices and systems, Traffic marking coatings 100
Product-weighted MIR Limits for ROC in Section 4522(a)(2) and other
HVAC systems, photovoltaic systems, electric vehicle chargers, requirements, including prohibitions on use of certain toxic compounds and o one Tub and tile refinish coatings 420
4.303.1.2 Urinals. The effective flush volume of wallmounted urinals shall not exceed water-heating systems and other ma or appliances and equipment. depleting substances, in Sections 4522(e)(1) and (f)(1) of California Code of Waterproofing membranes 250 CHAPTER 7
0.125 gallons per flush. The effective flush volume of all other urinals shall not INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS SECTION

MISSION STREET RESIDENCE


b. Roof and yard drainage, including gutters and downspouts. Regulations, Title 17, commencing with Section 4520 and in areas under the Wood coatings 275
exceed 0.5 gallons per flush. c. Space conditioning systems, including condensers and air filters. Wood preservatives 350
urisdiction of the Bay Area Air Quality Management District additionally comply SECTION 702 QUALIFICATIONS
4.303.1.3 Showerheads. d. Landscape irrigation systems. inc-rich primers 340
with the percent VOC by weight of product limits of Regulation 8, Rule 4 . 702.1 Installer training. HVAC system installers shall be trained and certified in the proper installation of HVAC
e. Water reuse systems.
4.303.1.3.1 Single showerhead. Showerheads shall have a maximum flow rate of 3. Information from local utility, water and waste recovery providers on methods systems including ducts and equipment by a nationally or regionally recogni ed training or certification
not more than 2.0 gallons per minute at 80 psi. Showerheads shall be 4.504.2.4 Verification. Verification of compliance with this section shall be provided 1. Grams of VOC per liter of coating, including water and including exempt compounds. program. Uncertified persons may perform HVAC installations when under the direct supervision and
to further reduce resource consumption, including recycle programs and at the request of the enforcing agency. Documentation may include, but is not 2. The specified limits remain in effect unless revised limits are listed in subsequent columns
certified to the performance criteria of the U.S. EPA WaterSense Specification locations. responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC
limited to, the following: in the table.
for Showerheads. 4. Public transportation and or carpool options available in the area. 3. Values in this table are derived from those specified by the California Air Resources Board, systems. Examples of acceptable HVAC training and certification programs include but are not limited to the
1. Manufacturer s product specification. following:
5. Educational material on the positive impacts of an interior relative humidity 2. Field verification of on-site product containers.
Architectural Coatings Suggested Control Measure, February 1, 2008. More information is
4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served between 30 60 percent and what methods an occupant may use to maintain available from the Air Resources Board. 1. State certified apprenticeship programs.

APN: 010-121-021
by more than one showerhead, the combined flow rate of all showerheads the relative humidity level in that range. 2. Public utility training programs.
and or other shower outlets controlled by a single valve shall not exceed 2.0 6. Information about water-conserving landscape and irrigation design and 4.504.3 Carpet systems. All carpet installed in the building interior shall meet the 3. Training programs sponsored by trade, labor or statewide energy consulting or verification
gallons per minute at 80 psi, or the shower shall be designed to allow only controllers which conserve water. 7. Instructions for maintaining gutters and testing and product requirements of one of the following: organi ations.

APN:
one shower outlet to be in operation at a time. downspouts and the importance of diverting water at least 5 feet away from 1. Carpet and Rug Institute s Green Label Plus Program. 4. Programs sponsored by manufacturing organi ations.
Note: A hand-held shower shall be considered a showerhead. 2. California Department of Public Health, Standard Method for the Testing 5. Other programs acceptable to the enforcing agency.
the foundation. 8. Information on required routine maintenance measures, TABLE 4.504.2 and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources
including, but not limited to, caulking, painting, grading around the building, SEALANT VOC LIMIT
4.303.1.4 Faucets. Using Environmental Chambers, Version 1.1, February 2010 (also known as 702.2 Special inspection. [HCD] When required by the enforcing agency, the owner or the responsible entity

Pro ect Address


etc.
Less Water and Less Exempt Compounds in Grams per Liter

Drawing Title:
4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of residential Specification 01350.) acting as the owner s agent shall employ one or more special inspectors to provide inspection or other duties
. Information about state solar energy and incentive programs available.
lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi. The 3. NSF ANSI 140 at the Gold level. necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to
10. A copy of all special inspection verifications required by the enforcing agency or
SEALANTS VOC LIMIT the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In

ob Title:
minimum flow rate of residential lavatory faucets shall not be less than 0.8 this code. 4. Scientific Certifications Systems Indoor Advantage Gold.
gallons per minute at 20 psi. addition to other certifications or qualifications acceptable to the enforcing agency, the following
Architectural 250 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall certifications or education may be considered by the enforcing agency when evaluating the qualifications of
4.410.2 Recycling by occupants. Where 5 or more multifamily dwelling units are
4.303.1.4.2 Lavatory faucets in common and public use areas. The maximum Marine deck 760 meet the requirements of the Carpet and Rug Institute s Green Label program. a special inspector:
constructed on a building site, provide readily accessible area(s) that serves all
flow rate of lavatory faucets installed in common and public use areas Nonmembrane roof 300 1. Certification by a national or regional green building program or standard publisher.
buildings on the site and is identified for the depositing, storage and collection of
(outside of dwellings or sleeping units) in residential buildings shall not Roadway 250 4.504.3.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 2. Certification by a statewide energy consulting or verification organi ation, such as HERS raters, building
non-ha ardous materials for recycling, including (at a minimum) paper, corrugated
exceed 0.5 gallons per minute at 60 psi. Single-ply roof membrane 450 4.504.1. performance contractors, and home energy auditors.
cardboard, glass, plastics, organic waste, and metals, or meet a lawfully enacted local
Other 420 3. Successful completion of a third party apprentice training program in the appropriate trade. Pro ect: Sheet
recycling ordinance, if more restrictive.
4.303.1.4.3 Metering faucets. Metering faucets when installed in residential 4.504.4 Resilient flooring systems. Where resilient flooring is installed, at least 80 4. Other programs acceptable to the enforcing agency.
Exception: Rural urisdictions that meet and apply for the exemption in Public
Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the pro ect
HC1754
buildings shall not deliver more than 0.25 gallons per cycle. SEALANT PRIMERS percent of floor area receiving resilient flooring shall comply with one or more of
Resources Code Section 4264 .82 (a)(2)(A) et seq. are not required to comply with
the following: they are inspecting for compliance with this code.

G1
the organic waste portion of this section. Date:
4.303.1.4.4 Kitchen faucets. The maximum flow rate of kitchen faucets shall not Architectural 1. Products compliant with the California Department of Public Health, 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in
exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily Nonporous 250 Standard Method for the Testing and Evaluation of Volatile Organic California according to the Home Energy Rating System (HERS). 12/12/2019
Division 4.5 ENVIRONMENTAL QUALITY
increase the flow above the maximum rate, but not to exceed 2.2 gallons per Porous 775 Chemical Emissions from Indoor Sources Using Environmental Chambers, Drawn By:
minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per Version 1.1, February 2010 (also known as Specification 01350), certified as a SECTION 703 VERIFICATIONS
SECTION 4.501 GENERAL Modified bituminous 500
minute at 60 psi. CHPS Low-Emitting Material in the Collaborative for High Performance 703.1 Documentation. Documentation used to show compliance with this code shall include but is not limited
4.501.1 Scope. The provisions of this chapter shall outline means of reducing the Marine deck 760 AAP
Note: Where complying faucets are unavailable, aerators or other means Schools (CHPS) High Performance Products Database. to, construction documents, plans, specifications, builder or installer certification, inspection reports, or
quantity of air contaminants that are odorous, irritating and or harmful to the Other 750 other methods acceptable to the enforcing agency which demonstrate substantial conformance. When Scale:
may be used to achieve reduction. 4.303.2 Standards for plumbing fixtures comfort and wellbeing of a building s installers, occupants and neighbors. 2. Products certified under UL GREENGUARD Gold (formerly the Greenguard
and fittings. Plumbing fixtures and fittings shall be installed in accordance specific documentation or special inspection is necessary to verify compliance, that method of compliance 1/8"=1'-0"
Children Schools program).
with the California Plumbing Code, and shall meet the applicable standards will be specified in the appropriate section or identified in the application checklist.
SECTION 4.502 DEFINITIONS 3. Certification under the Resilient Floor Covering Institute (RFCI) FloorScore
program.
Revision/Issue Date

DESIGN@HASTINGSCONSTRUCTION.COM | LIC#: 791539


HASTINGS CONSTRUCTION, INC.
316 MID VALLEY CENTER | SPACE 161
CARMEL, CA 93923 | (831) 620-0920
CMC CONSTRUCTION BEST MANAGEMENT PRACTICES & GEN. NOTES

MISSION 2 SW FIRST, CARMEL-BY-THE-SEA, CALIFORNIA


fiber rolls notes: of sediment accumulation, and fill and compact
STABILIZED CONSTRUCTION ENTRANCE notes: Limitations: holes, trenches, depressions or any other ground Silt fence notes: a minimum width of 36 in. and a minimum tensile - Posts should be spaced a maximum of 6 ft apart
- Construct on level ground where possible. - Runoff and erosion may occur if fiber roll is not disturbance to blend with adjacent ground. - The fence should be supported by a plastic or strength of 100 lb force. The fabric should and driven securely into the ground a
INSPECTION & MAINTENANCE:
- Select 3 to 6 in. diameter stones. adequately trenched in. wire mesh if the fabric selected does not have conform to the requirements in ASTM designation - minimum of 18 in. or 12 in. below the bottom of the
- Inspect and verify that activity–based BMPs are in
- Use minimum depth of stones of 12 in. or as - Fiber rolls at the toe of slopes greater than 1:5 Maintenance and Inspection: sufficient strength and bursting strength D4632 and should have an integral reinforcement trench.
place prior to the commencement of associated
recommended by soils engineer. may require the use of 20” diameter or - Repair or replace split, torn, unraveling, or characteristics for the planned application (as layer. The reinforcement layer should be a - When standard strength geotextile is used, a
activities. While activities associated with the BMPs
- Construct length of 50 ft or maximum site will allow, installations achieving the same protection (i.e., slumping fiber rolls. polypropylene, or equivalent, net provided by plastic or wire mesh support fence should be
are under way, inspect BMPs in accordance with recommended by the fabric manufacturer). Woven

MISSION STREET RESIDENCE


and 10 ft minimum width or to accommodate traffic. - Inspect fiber rolls when rain is forecast. Perform the manufacturer. The permittivity of the fabric fastened securely to the upslope side of posts
General Permit requirements for the associated stacked smaller diameter fiber rolls, etc.). geotextile material should contain ultraviolet
- Rumble racks constructed of steel panels with maintenance as needed or as required by the RE. should be between 0.1 sec-1 and 0.15 sec-1 in using heavy–duty wire staples at least 1 in.long. The
project type and risk level. It is recommended that - Fiber rolls may be used for drainage inlet inhibitors and stabilizers to provide a minimum of
ridges and installed in the stabilized entrance/exit - Inspect fiber rolls following rainfall events and conformance with the requirements in ASTM mesh should extend into the trench.
at a minimum, BMPs be inspected weekly, prior to protection if they can be properly anchored. six months of expected usable construction
will help remove additional sediment and to keep a least daily during prolonged rainfall. Perform designation D4491. - When extra-strength geotextile and closer post
forecasted rain events, daily during extended rain - Difficult to move once saturated. life at a temperature range of 0 °F to 120 °F.
adjacent streets clean. maintenance as needed or as required by the RE. - Wood stakes should be commercial quality lumber spacing are used, the mesh support fence
events, and after the conclusion of rain events. - Fiber rolls could be transported by high flows if - Layout in accordance with attached figures.
- Provide ample turning radii as part of the entrance. - Maintain fiber rolls to provide an adequate of the size and shape shown on the plans. - may be eliminated.
- Inspect local roads adjacent to the site daily. not properly staked and trenched in. - For slopes steeper than 2:1 (H:V) and that contain a
- Limit the points of entrance/exit to the construction sediment holding capacity. Sediment shall be - Each stake should be free from decay, splits or - Woven geotextile should be purchased in a long
Sweep or vacuum to remove visible accumulated - Fiber rolls have limited sediment capture zone. high number of rocks or large dirt clods
site. removed when the sediment accumulation reaches cracks longer than the thickness of the stake or roll, then cut to the length of the barrier.
sediment. - Do not use fiber rolls on slopes subject to creep, that tend to dislodge, it may be necessary to
- Limit speed of vehicles to control dust. three quarters (3/4) of the barrier height. other defects that would weaken the stakes and - When joints are necessary, geotextile should be
- Remove aggregate, separate and dispose of slumping, or landslide. install additional protection immediately
- Properly grade each construction entrance/exit to Removed sediment shall be incorporated in the cause the stakes to be structurally unsuitable. spliced together only at a support post, with

APN: 010-121-021
sediment if construction entrance/exit is clogged adjacent to the bottom of the slope, prior to
prevent runoff from leaving the construction site. project at locations designated by the RE or - Staples used to fasten the fence fabric to the - a minimum 6 in. overlap and both ends securely
with sediment. Standards and Specifications: installing silt fence. Additional protection may
- Route runoff from stabilized entrances/exits through disposed of outside the highway right-of-way in stakes should be not less than 1.75 in. long and fastened to the post.
- Keep all temporary roadway ditches clear. Fiber Roll Materials: be a chain link fence or a cable fence.
a sediment trapping device before discharge. conformance with the Standard Specifications. should be fabricated from 15 gauge or heavier - The trench should be backfilled with native
- Check for damage and repair as needed. Fiber rolls shall be either: - For slopes adjacent to sensitive receiving waters
wire. The wire used to fasten the tops of the stakes material and compacted.

Project Address & APN:


- Design stabilized entrance/exit to support heaviest - Replace gravel material when surface voids are 1. Prefabricated rolls. or Environmentally Sensitive Areas (ESAs), together when joining two sections of fence should
vehicles and equipment that will use it. from: Caltrans Storm Water Quality Handbooks Section - Construct silt fences with a setback of at least 3
visible. 2. Rolled tubes of erosion control blanket. silt fence should be used in conjunction with
- Select construction access stabilization (aggregate, 4; Construction Site Best Management Practices Manual be 9 gauge or heavier wire. ft from the toe of a slope. Where, due to specific
- Remove all sediment deposited on paved roadways erosion control BMPs.
Fiber Rolls SC-5 - Galvanizing of the fastening wire will not be site conditions, a 3 ft setback is not available, the
asphaltic concrete, concrete) based on longevity, within 24 hours. Assembly of Field Rolled Fiber Roll:
required. silt fence may be constructed at the toe of the

Drawing Title:
required performance, and site conditions. Do not - Remove gravel and filter fabric at completion of - Roll length of erosion control blanket into a Standard vs. Heavy Duty Silt Fence Heavy-Duty Silt Fence: slope, but should be constructed as far from the
use asphalt concrete (AC) grindings for stabilized construction tube of minimum 8 in diameter. Standard Silt Fence: - Some silt fence has a wire backing to provide toe of the slope as practicable. Silt fences close
- Bind roll at each end and every 4 ft along length

Job Title:
construction access/roadway. - Generally applicable in cases where the slope of additional support, and there are products that
of roll with jute-type twine. to the toe of the slope will be less effective and
- If aggregate is selected, place crushed aggregate area draining to the silt fence is 4:1 (H:V) or less. may use prefabricated plastic holders for the more difficult to maintain.
over geotextile fabric to at least 12 in. depth, or - Used for shorter durations, typically 5 months or silt fence and use metal posts or bar
Installation: - Construct the length of each reach so that the
place aggregate to a depth recommended by a less reinforcement instead of wood stakes. If bar
- Slope inclination of 1:4 or flatter: fiber rolls change in base elevation along the reach does
geotechnical engineer. A crushed aggregate - Area draining to fence produces moderate reinforcement is used in lieu of wood stakes, use
shall be placed on slopes 6.0 m apart. not exceed 1/3 the height of the barrier; in no case
greater than 3 in. but smaller than 6 in. should be sediment loads. number four or greater bar. Provide end
- Slope inclination of 1:4 to 1:2: fiber rolls shall be should the reach exceed 500 ft.
used. Heavy Duty Silt Fence: protection for any exposed bar reinforcement
placed on slopes 4.5 m apart. - Cross barriers should be a minimum of 1/3 and a
- Designate combination or single purpose entrances - Use is generally limited to 8 months or less. for health and safety purposes.
and exits to the construction site. - Slope inclination 1:2 or greater: fiber rolls shall maximum of ½ the height of the linear barrier. Project: Sheet
- Area draining to fence produces moderate
- Require that all employees, subcontractors, and be placed on slopes 3.0 m apart. sediment loads. Installation Guidelines – Traditional Method: HC1754
suppliers utilize the stabilized construction access. - Stake fiber rolls into a 50 to 2 to 4 in trench. - Heavy duty silt fence usually has 1 or more of the - Silt fences are to be constructed on a level

G2
- Implement SE-7, Street Sweeping and Vacuuming, as - drive stakes at the end of each fiber roll and following characteristics, not Date:
contour. Sufficient area should exist behind the
needed. spaced space stakes 4 ft maximum on center if possessed by standard silt fence.
- All exit locations intended to be used for more than installed as shown on Pages 1.3 of this set.
fence for ponding to occur without flooding or 12/12/2019
- Fence fabric has higher tensile strength. overtopping the fence.
a two-week period should have stabilized - Use wood stakes with a nominal classification of 19 - Fabric is reinforced with wire backing or Drawn By:
- A trench should be excavated approximately 6 in.
construction entrance/exit BMPs. by 19 mm (43" by 43" and minimum length of 24 in. additional support. wide and 6 in. deep along the line of the
- If more than one fiber roll is placed in a row, the - Posts are spaced closer than pre-manufactured, - proposed silt fence (trenches should not be AAP
rolls shall be overlapped; not abutted. standard silt fence products. excavated wider or deeper than necessary for Scale:
- Posts are metal (steel or aluminum) - proper silt fence installation).
Removal:
- Bottom of the silt fence should be keyed-in a
1/8"=1'-0"
- Fiber rolls are typically left in place. Materials: minimum of 12 in.
- If fiber rolls are removed, collect and dispose Standard Silt Fence:
- Silt fence material should be woven geotextile with
9x9 catch basin downspout w/ Revision/Issue Date
PROPERTY LINE at downspout splash block

4" solid pipe; 2% SLOPE TOWARDS RAIN GARDEN - TYPICAL 4" solid pipe (permeable)
(permeable)

ds

7'-6"
ds ds
(permeable)
ds
rain
garden

DESIGN@HASTINGSCONSTRUCTION.COM | LIC#: 791539


HASTINGS CONSTRUCTION, INC.
dn

316 MID VALLEY CENTER | SPACE 161


CARMEL, CA 93923 | (831) 620-0920
8'-1"
CONTRIBUTING AREA: 653 sq. FT.
CONTRIBUTING
AREA: 78.5 SQ. FT.

60 SQ. FT rain 15'-3"

PROPERTY LINE
garden

driveway
(permeable)

permeable deck ds
PROPERTY LINE

CONTRIBUTING AREA: 355 sq. FT.

DECK EL. 90'-0"

12'
6'

ds ds
35 SQ. FT rain 4" solid pipe; 2% SLOPE TOWARDS RAIN GARDEN - TYPICAL
garden

SETBACK
3'
PROPERTY LINE

MISSION 2 SW FIRST, CARMEL-BY-THE-SEA, CALIFORNIA


DRAINAGE PLAN

NOTES:
ALL INFILTRATION SYSTEM(S) SHALL BE DESIGNED IN ACCORDANCE WITH
CARMEL municipal code (cmc) standard operating guidance
(sog) 17-07 for private STORMWATER DRAINAGE SYSTEMS.

Drainage from downspouts and paved areas shall be


directed to landscaped areas, or collected in
French drains or subgrade perforated pipe collectors, and
conveyed to infiltration Best
Management Practices (BMP) such as rain gardens or
infiltration trenches.

MISSION STREET RESIDENCE


Rain gardens shall be designed in accordance with the Bay
Area Stormwater Management Agencies
Association (BASMAA) publication Rain Gardens, Stormwater
Control for Small Projects.

DRAINAGE PLAN

APN: 010-121-021
refer to https://ci.carmel.ca.us/pod/private-drainage-systems
for approved list of rain garden plants.

Project Address & APN:


The landscaped areas used for infiltration shall be at least
50% of the size of the contributing impervious surface.

Drawing Title:

Job Title:
Runoff shall be directed away from building foundations.

Overflow must be directed away from neighboring properties.


Overflow to the street requires an Encroachment Permit
approved by the Public Works Director.
Project: Sheet
HC1754
Date:

A1.2
12/12/2019
Drawn By:

AAP
Scale:
1/8"=1'-0"
PROPERTY LINE
Revision/Issue Date

EQUIPMENT STORAGE,
BUILDING
MATERIALS/STAGING,
WASHOUT AREAS

DESIGN@HASTINGSCONSTRUCTION.COM | LIC#: 791539


HASTINGS CONSTRUCTION, INC.
316 MID VALLEY CENTER | SPACE 161
CARMEL, CA 93923 | (831) 620-0920
proposed
addition
originally approved RESIDENCE

10'
STABILIZED CONSTRUCTION ENTRANCE
(see detail tc-1)
PROPERTY LINE

PROPERTY LINE
CONCRETE
PUMP AREA

fiber rolls - typical

SC-5

SETBACK
3'
silt fence to surround entire site
PROPERTY LINE

EROSION & SEDIMENT CONTROL PLAN SE-1

MISSION 2 SW FIRST, CARMEL-BY-THE-SEA, CALIFORNIA


note: see general notes sheet G2
"
48
note: see general notes sheet G2

"
48

EROSION & SEDIMENT CONTROL PLAN


"
48

MISSION STREET RESIDENCE


"
48

APN: 010-121-021
Project Address & APN:
Drawing Title:

Job Title:
Project: Sheet
HC1754
Date:

A1.3
12/12/2019
Drawn By:

AAP
Scale:
1/8"=1'-0"
ADDITION PREVIOUSLY APPROVED
ELECTRICAL NOTES: 56'-1"
ELECTRICAL, LIGHTING & MECHANICAL DEVISES
SHOWN ON DRAWINGS INDICATES ARCHITECTURAL 16'-3" 9'-8" 12'-10" 7'-2" 3' 4'-9" 1'-4" 1' Revision/Issue Date
DESIGN INTENT ONLY. ELECTRICAL & MECHANICAL
12'-11" 3'-4"
SUBCONTRACTOR TO MEET WITH OWNER'S FINAL = NEW WALL
APPROVAL AND/OR REVISIONS.
= EXISTING WALL TO REMAIN
VERIFY PHONE & TV JACK LOCATIONS WITH OWNER
= EXISTING RETAINING
PRIOR TO INSTALLATION - TYPICAL.
WALL TO REMAIN

ALL ELECTRICAL FIXTURES selected PER = EXISTING WALL/ELEMENT


OWNER'S SPECIFICATIONS SHALL BE INSTALLED ROOF OVERHANG TO BE REMOVED
PER MANUFACTURER'S SPECS AND SHALL - TYPICAL adjust steps
as shown
COMPLY WITH 2016 CA ENERGY CODE.

Installed luminaries shall be classified as ELECTRICAL SYMBOLS LIST


high-efficacy or low-efficacy for

DESIGN@HASTINGSCONSTRUCTION.COM | LIC#: 791539


3'-1"
new 2840

3'-6"
compliance with Section 150.0(k) in dn 110V DUPLEX OUTLET

HASTINGS CONSTRUCTION, INC.


accordance with TABLE 150.0-A or TABLE csmt.

ENTRY DECK
7' hdr. ht. 110V gfi DUPLEX OUTLET
150.0-B, as applicable.
single switch

1'-4"

316 MID VALLEY CENTER | SPACE 161


No controls shall bypass a dimmer or

1'-1"

CARMEL, CA 93923 | (831) 620-0920


new 2840

7' hdr. ht.


vacancy sensor function where that dimmer 3-way switch
NEW WOOD STEPS
MASTER

csmt.
or vacancy sensor has been installed to
TO GRADE
comply with Section 150.0(k). RISE: 7.5" BATH dimmer switch

LIVING
6:12 SLOPE

3'
TREAD: 12"

6'-6"
3-way dimmer switch
Lighting controls shall comply with the
applicable requirements of Section 110.9.
NEW FAMILY ROOM dn RECESSED can LIGHT FIXTURE
NEW 36" HIGH metal
Luminaries recessed into ceilings shall meet
all of the following requirements:
RAILING - BALUSTERS
SPACED SO THAT A 4"
dn
slopped ceiling
door to be replaced
dn ENTRY P.R. wall mounted light fixture
GAS

13'-1"
SPHERE CANNOT PASS w/cased opening FUEL GAS
THROUGH - TYP.
A. Be Listed, as defined in Section 100.1,
for zero clearance insulation new gas fireplace DATA JACK (VERIFY CABLE TYPE)
PROVIDE BLOCKING & PANTRY
contact (IC) by Underwriters

23'-10"

23'-10"
ELECT. FOR TV 6:12 SLOPE TV JACK/CABLE
Laboratories or other nationally REF
recognized testing/rating

7' hdr. ht.


new 2840
laboratory; and NOTE: ALL EXISTING ELECTRICAL TO REMAIN

csmt.
previously approved

(n) shelves
remove windows UNLESS NOTED OTHERWISE. CONTRACTOR TO
to remain unchanged
B. Have a label that certifies that the VERIFY EXISTING ELECTRICAL CONDITIONS.
luminaire is airtight with air leakage 14'-6"
(n) 2x6 wall
MASTER BEDROOM
less than 2.0 CFM at 75 Pascals when
tested in accordance with ASTM E283.
NEW IPE DECK NEW 10070 BI-FOLD door SYSTEM KITCHEN DINING

12'
An exhaust fan housing shall not be DW GENERAL NOTES:
required to be certified airtight; and

C. Be sealed with a gasket or caulk THIS PROJECT SHALL COMPLY WITH 2016 CALIFORNIA

4'-8"
between the luminaire housing and RESIDENTIAL CODE (CRC), CALIFORNIA MECHANICAL CODE

MODELNUMBER
TRADENAME
MATERIAL
PRODUCT
ceiling, and shall have all air leak (CMC), CALIFORNIA PLUMBING CODE (CPC), CALIFORNIA
paths between conditioned and ELECTRICAL CODE (CEC), & CALIFORNIA ENERGY CODE
unconditioned spaces sealed with a (CENC), CALIFORNIA FIRE CODE (CFC).
gasket or caulk; and

1'-1"
CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS,
D. For recessed compact fluorescent MATERIALS, AND CONDITIONS PRIOR TO STARTING

1'-10"
luminaries with ballasts to qualify as CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE

1'-11"
high efficacy for compliance with DESIGNER OR OWNER PRIOR TO ORDERING MATERIALS.
Section 150.0(k), the ballasts shall
be certified to the Commission to CONTRACTOR TO PROTECT EXISTING CONDITIONS FROM
comply with the applicable DAMAGE, DUST, AND DEBRIS.
requirements in Section 110.9; and
MATERIALS PLANNED TO BE REUSED ARE TO BE
E. Allow ballast maintenance and PROTECTED FROM DAMAGE THROUGHOUT THE DEMOLITION
replacement to be readily PROCESS.
accessible to building occupants 10'-3" 12'-11" 1'-10" 1'-6" 9'-8" 12'-11" 17'-3"
from below the ceiling without CONTRACTOR IS RESPONSIBLE FOR COMPLETE FINAL
requiring the cutting of holes in the 25' 41'-4" DISPOSAL OF ALL CONSTRUCTION DEBRIS IN A MANNER
ceiling. CONSISTENT WITH ALL APPLICABLE FEDERAL, STATE AND
LOCAL LAWS.
RESIDENTIAL OUTDOOR LIGHTING PERMANENTLY
MOUNTED TO THE DWELLING shall follow the where new work adjoins existing, elements are to be

ENTRY LEVEL FLOOR PLAN


lighting requirements: attached in alignment with tight fit, secure
- Wall-mounted lighting shall be no construction so that there is no change in the
higher than 10 feet above the ground visual appearance- patches, changes in paint
and shall not exceed 25 watts per and/or wall covering, etc. if necessary, remove
fixture (approximately 375 lumens). surface of existing elements and install new for
- Landscape lighting shall not exceed smooth integration.
18 inches above the ground nor more 4. Smoke alarms shall receive their
than 15 watts per fixture primary power from the building wiring BASEBOARDS ARE TO BE PRIMER GRADE WOOD IN ALL
(approximately 225 lumens). provided that such wiring is served 40'-3" ROOMS u.N.O. - SELECTION BY OWNER OR DESIGNER.

MISSION 2 SW FIRST, CARMEL-BY-THE-SEA, CALIFORNIA


- Landscape lights shall be spaced at from a commercial source and shall be
least 10 feet apart. No lighting may be equipped with a battery backup. Smoke 9'-8" 28'-7" 2' GYPSUM WALL BOARD PANELS SHALL BE TAPED AND
used to accent trees, walls, fences, alarms shall emit a signal when the FINISHED TO MATCH EXISTING. ALL JOINT & TAPE SHALL BE
etc. batteries are low. Wiring shall be APPLIED PER MANUFACTURER SPECIFICATIONS. METAL
- No lighting is permitted upon City permanent and without a disconnecting BEAD SHALL BE USED AT ALL CORNERS (U.N.0.) AND
property or directed towards City switch other than as required for CEMENT BOARD SHALL BE USED UNDER ALL TILE
property, including the Right of Way. over-current protection (CRC R314.4). APPLICATIONS.
exceptions:
RESIDENTIAL OUTDOOR LIGHTING PERMANENTLY 1. Smoke alarms are permitted to be NOTE:
MOUNTED TO THE DWELLING OR TO OTHER solely battery operated in buildings water-resistant gypsum backing board should not

ENTRY LEVEL & LOWER LEVEL FLOOR PLANS


BUILDINGS ON THE SAME LOT SHALL BE that are not served from a be used in the following locations per cbc 2512:
CONTROLLED BY A MANUAL ON AND OFF SWITCH wash dry
commercial power source. 1) over vapor retarder
AND CONTROLLED BY A PHOTOCELL AND MOTION
SENSOR OR BY PHOTO-CONTROL AND AUTOMATIC
2. Smoke alarms are permitted to be
solely battery operated in existing
BATH 2) in areas subject to continuous high humidity

2
3) on ceiling where frame spacing exceeds 12" on
TIME SWITCH CONTROL OR BY ASTRONOMICAL TIME areas of buildings undergoing center.
CLOCK CONTROL THAT AUTOMATICALLY TURNS alterations or repairs that do not

10'-3"
THE OUTDOOR LIGHTING OFF DURING DAYLIGHT result in the removal of interior
DOOR & WINDOW NOTES:
BEDROOM 3/DEN
HOURS OR BY AN ENERGY MANAGEMENT UP
walls or ceiling finishes exposing the
CONTROL SYSTEM. structure, unless there is an attic,
1. all GLAZING subject to human impact SHALL
crawl space or basement available
ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. which could provide access for CONFORM to crc SECTIONS R308.3 & R308.4.
ALL 1220-VOLT 15 AND 20 AMPERE OR BRANCH building wiring without the removal of 1.1. GLAZING ADJACENT TO STAIRWAYS, LANDINGS
CIRCUITS SUPPLYING OUTLETS INSTALLED IN AND RAMPS WITHIN 36 INCHES HORIZONTALLY

MISSION STREET RESIDENCE


interior finishes.
DWELLING UNIT FAMILY Rooms, kitchens, DINING furn OF A WALKING SURFACE WHEN SURFACE OF THE
ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, GLAZING IS LESS THAN 60 INCHES ABOVE THE
DENS, BEDROOMS, SUNROOMS, RECREATION CO2 DETECTORS/ALARMS: PLANE OF THE ADJACENT WALKING SURFACE.
ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS Carbon monoxide alarms shall be listed as
OR AREA SHALL BE PROTECTED BY A LISTED complying with UL 2034 and be installed and 2. all windows, doors & hardware selections

24'-2"
ARC-FAULT CIRCUIT INTERRUPTER maintained in accordance with NFPA 720 and shall be verified by owner.
19'-5"

COMBINATION-TYPE. GUESTROOMS (210-18) AND the manufacturer’s instructions R315.1.


GUEST SUITES THAT ARE PROVIDED WITH 3. All exterior door & window trim shall match
PERMANENT PROVISIONS FOR COOKING SHALL Carbon monoxide alarms required by existing.

APN: 010-121-021
HAVE AFCI [210-12(B)] Section R315.1 shall be installed Outside of
each separate dwelling unit sleeping area in 4. window and door sizes shown for design
tamper resistant receptacles are required the immediate vicinity of the bedroom(s) (crc purposes only. actual window and door sizes

Project Address & APN:


BEDROOM 2
in all locations except at outlets located
GARAGE
R315.1.4). shall be framed & set per manufacturer's

12'-4"
more than 5'-6" above the floor, outlets specifications. CONTRACTOR TO FIELD VERIFY
that are a part of a luminaire, outlets Carbon monoxide alarms shall receive SIZES AND SELECT NEAREST MANUFACTURER'S SIZES
dedicated to appliances that cannot be their primary power from the building PRIOR TO ORDERING.

Drawing Title:
easily moved and at outlets located in wiring where such wiring is served from a
attics. commercial source and shall be equipped

Job Title:
with a battery back-up. Alarm wiring shall
SMOKE DETECTORS: be directly connected to the permanent
verify existing smoke detectors or install building wiring without a disconnecting switch
new per below: other than as required for over-current
1. A smoke detector, approved and protection. (crc R315.1.2)
listed by the State Fire Marshal Exceptions:
pursuant to Section 13114, shall be 1. In dwelling units where there is no WINDOW SEAT

1'-7"
installed, in accordance with the Sheet
commercial power supply carbon Project:
manufacturer's instructions.
2. Smoke alarms shall be installed in
monoxide alarms may be solely HC1754
battery operated
each sleeping room and outside each 2. Other power sources recognized for 10' 12'-10" 17'-5" Date:

A2
separate sleeping area in the immediate use by NFPA 720 Where more than one
12/12/2019
LOWER LEVEL FLOOR PLAN
vicinity of the bedrooms (crc R314.3). carbon monoxide alarm is required
3. smoke alarms shall be interconnected to be installed within the dwelling unit Drawn By:
in such a manner that the activation of or within a sleeping unit the alarm
one alarm will activate all alarms. The shall be interconnected in a manner AAP
alarm shall be clearly audible in all that activation of one alarm shall Scale:
bedrooms over background noise
levels with all intervening doors
activate all of the alarms in the previously approved 1/8"=1'-0"
individual (crc R315.1.3).
closed (CRC R314.5). to remain unchanged
new class 'a' comp.
shingle roof w/2x fascia &
copper gutter - to match
previously approved Revision/Issue Date
ridge 104'-6" permitted structure - typ.

family rm. ridge 103'-6"


12
6 SLOPE
SLOPE CHANGE SLOPE CHANGE
new chimney w/stone
veneer

8'-1" PLATE ht.


abv. FAMILY RM. f.f.

NEW EXTERIOR LIGHT

DESIGN@HASTINGSCONSTRUCTION.COM | LIC#: 791539


FIXTURE

HASTINGS CONSTRUCTION, INC.


new ipe deck and
powder coated metal railing

7'

316 MID VALLEY CENTER | SPACE 161


CARMEL, CA 93923 | (831) 620-0920
ENTRY LEVEL
ENTRY f.f. (92.0')

3'
FAMILY RM. 90'-2" f.f. FAMILY RM. f.f. (90.16')

new board & batten


siding spaced as shown
- to match previously
approved permitted
structure - typ

new 1" stucco siding - to


match prev. approved
- typical

GARAGE SLAB F.F.(83.0')

previously approved
to remain unchanged
PREVIOUSLY APPROVED UNDER PERMIT #17011 RV 01 PROPOSED DECK AND FAMILY ROOM ADDITION

EAST (MISSION STREET) ELEVATION (FRONT) NORTH ELEVATION (RIGHT SIDE)

12
6 SLOPE

8'-1" PLATE ht.


abv. FAMILY RM. f.f.

3
A4

4
A4

7'
new class 'a' comp.
shingle roof w/2x fascia &
copper gutter - to match family rm. ridge 103'-6"

3'
previously approved
permitted structure - typ.
FAMILY RM. f.f.

MISSION 2 SW FIRST, CARMEL-BY-THE-SEA, CALIFORNIA


new chimney w/stone
veneer

8'-1" PLATE ht.


abv. FAMILY RM. f.f.
NEW EXTERIOR LIGHT OUTLINE OF PROPOSED
FIXTURE DECK

new door trim to match


prev. approved

EXTERIOR ELEVATIONS & CROSS SECTION


GARAGE SLAB F.F.(83.0')

WEST ELEVATION (REAR)


FAMILY RM. f.f.

MAIN ELECTRIC
PANEL LOCATION

MISSION STREET RESIDENCE


new board & batten
siding spaced as shown GAS METER
- to match previously LOCATION
FINISH GRAD
approved permitted E 12
structure - typ class 'a' comp. shingle
6 SLOPE
thinwall plaster roof w/ copper gutter
new 1" stucco siding - to o/2x fascia - to match
GARAGE SLAB F.F. (to match existing)
match prev. approved existing

APN: 010-121-021
- typical
r-30 insulation
8'-1" PLATE ht. 8

Project Address & APN:


abv. FAMILY RM. f.f. a4

2x8 pt df#2 ledger


PROPOSED DECK AND FAMILY ROOM ADDITION PREVIOUSLY APPROVED UNDER PERMIT #17011 RV 01

Drawing Title:
with 1/2" lag @
(NO CHANGED PROPOSED) 16" o.c. staggered

Job Title:
PROPOSED SOUTH ELEVATION (LEFT SIDE)
5
board & batten siding -
copper flashing a4 to match existing
as req'd

1x6 IPE belly band trim


decking

FAMILY RM. f.f.90'-2" Project: Sheet


deck f.f.90'-0" 1" stucco below belly
band - typ. HC1754
2x8 PT DF#2 deck
Date:

A3
JOISTS @ 16" o.c. w/ r-19 insulation 4" min. weep screed
2x blocking
12/12/2019
Drawn By:
7 AAP
a4 Scale:

CROSS SECTION 1/8"=1'-0"

A
FOUNDATION & FRAMING NOTES: REQUIRED. diaphragm & and the shear shall be MAKE ANGLED CUTS @ CORNERS, FOLD Revision/Issue Date
wood framing shall be in accordance w/ Cbc 2016 transferred according to cbc chapter 23. UP AND TEMPORARILY SECURE FLAP
chapter 23. PROVIDE G.I. FLASHING or copper AS REQUIRED. WITH FLASHING TAPE. TACK FLAP
PROVIDE WEATHERPROOFING FOR ALL EXPOSED provide 1
TEMPORARILY WITH SHEATHING TAPE
2" gypsum board at ceilings w/ 16" o.c.
STRUCTURAL ITEMS. AND FOLD OVER HEAD FLASHING
all framing lumber shall be douglas fir (u.n.o.) spacing & 58" gypsum board @ 24" o.c. spacing.
and shall have a 19% max moisture content at time
of install. DOUBLE ALL FLOOR JOISTS BELOW PARALLEL
Door & window headers are to be #2 material -
PARTITIONS W/ 16D NAILS @ 12" STAGGERED - TYPICAL. CAULK BACKSIDE OD FLANGE -
blocking shall be placed between bearing walls typically 4x12 df @ 6'-8" (u.n.o.).
ALL MUDSILLS TO BE 2X6 PT/DF W/ 58"X10" A.B. @ 4'-0" TOP & SIDES ONLY - WITH 100% 1.
which are not parallel to the joists. SILICONE OR POLYURETHANE
O.C. MAX. 12" FROM ENDS OR MUDSILL, MIN. 4 83" FROM cripple walls to be braced min. 4'-0" wide
ENDS TYP. bracing per 25 linear ft. of wall SEALANT. INSTALL WINDOW PER EXTERIOR
5
SUBFLOOR TO BE 8" CDX T&G PLYWOOD W/ FACE GRAIN MANUFACTURER'S SPECS. SHEATHING
ALL SOLE/SILL NAILING TO BE 16D @ 6" O.C. LAID PERPENDICULAR TO FLOOR JOISTS W/ STAGGERED
Rafters to be 2x8 df#2 @ 16" o.c.; ridge to be 2x10.
JOINTS; GLUE & NAIL W/ 16D NAILS @ 6" O.C.E. - TYPICAL. 2. WATER RESISTIVE
All metal connectors shall be simpson or eq. BARRIER
roof sheathing to be 58" cdx plywood; nailing: 8d @

DESIGN@HASTINGSCONSTRUCTION.COM | LIC#: 791539


Wood-frame shear walls shall be designed and 6" o.c.e. and @ 12" o.c.f.

HASTINGS CONSTRUCTION, INC.


INSTALL G.I. HANGERS BY SIMPSON (OR EQ.) AS constructed in accordance with AWC SDPWS.
plywood shearwalls shall continue to the roof 3.

CORNER PATCH

316 MID VALLEY CENTER | SPACE 161


CARMEL, CA 93923 | (831) 620-0920
SILL FLASHING -
USE MOLDABLE
DBL. top plate with 16d FIRE BLOCKING CUT PLATE TIED 4.
FLASHING OR CUT
@ 16" o.c. staggered AROUND PIPE W/16 GAGE STEEL & FOLD TO FORM
STRAP SILL PAN

HEAD FLASHING:
ROUGH OPENING + 2X
4-16d @ corner laps WIDTH OF FLASHING + 2"
& cross wall laps
CRIPPLE STUDS
top plate
FLASHING: R.O. + 2X WIDTH
OF FLASHING - 1"
2X DF#2 studs HEADER HEADER

where studs are over


1 TYPICAL WINDOW FLASHING DETAIL
9'-0" long, provide 2x
blocking midspan with BOARD & BATTEN SIDING O/
TRIMMER BUILDING WRAP (TYVEX OR EQ.)
2-10d t.n. or 2-16d e.n.
@ ea. end or ea. block SHEATHING & 2X STUD WALL
KING STUD
HEAD FLASHING 1/2" GYP. BD.
w/ plaster finish
DOOR ROUGH WINDOW ROUGH
OPENING OPENING
SELF-ADHERED MEMBRANE HEAD FLASHING
SILL 1X3 FLAT PAINT GRADE
EXTERIOR WINDOW TRIM
dbl. king studs with
a34 clip @ top & bott. bullnose
at exterior openings 16d @ 12" o.c. BLOCKING
where studs are over staggered - typ.
10'-0" long
LIQUID-APPLIED OR SHEET FLASHING
CRIPPLE STUDS BACKER ROD & SEALANT
SEALANT

2x sill DUAL PANE WINDOW


screen
5/8" DIA. X 10"
ANCHOR BOLTS FOUNDATION
EMBEDDED 7" MIN. 2-8d t.n. ea. side
6 F.T. O.C. MAX - TYPICAL

TYPICAL WALL FRAMING DETAIL 2 WINDOW HEAD DETAIL

1x3 FLAT PAINT GRADE INTERIOR WINDOW TRIM bullnose


T&G PLYWOOD
SEALANT
EXTERIOR sheathing
floor sheathing nailing
1X IPE DECKING TO BE @ 6" max. o.c. to joist w/
8"
ATTACHED TO JSTS. W/SIMPSON hold-down

MISSION 2 SW FIRST, CARMEL-BY-THE-SEA, CALIFORNIA


EB-TY PREMIUM FASTENING LIQUID-APPLIED OR SHEET FLASHING
SYSTEM
g.i. flashing
as req'd DUAL PANE WINDOW

min.
3"
BLOCKING
8"

SHEATHING AND STUD WALL


1'-4"

8"

2x p.t. df. ledger w/(2) SEALANT


sdw22330 @ 24" o.c.
CONC. footing w/ 2 #4 SELF-ADHERED MEMBRANE HEAD FLASHING
SIMPSON LU210 JOIST
bars ea. way w/ g.i. HANGER 1X3 FLAT PAINT GRADE EXTERIOR WINDOW TRIM
simpson 4X4 post base
- typical simpson DTT2Z DECK SEALANT
TENSION TIE W/ 1/2" DIA. ROD
24" SIDING
@ 48" O.C

MISSION STREET RESIDENCE


7 DECK FOOTING DETAIL 5 DECK CONNECTION DETAIL 3 WINDOW JAMB DETAIL (SIM.)

ARCHITECTURAL DETAILS
CLASS 'A' ASPHALT ROOF SHINGLES (CERTAINTEED
OR EQ.); INSTALL PER MANUF. SPECS. stud
5/8" cdx plywood sheathing
2 LAYERS 30# FELT (OR SYNTHETIC
UNDERLAYMENT EQUIVLANT) building wrap (tyvex or eq) DUAL PANE WINDOW

APN: 010-121-021
screen
3/8" CDX PLYWOOD SHEATHING

2X BLOCKING between rafters BACKER ROD & SEALANT

Project Address & APN:


w/3 -2" dia. screened vents every other bay

batten overlap 1/2" min. 1X2 SILL TRIM


copper gutter (install O/1X FLAT PAINT
per manuf. specs.)

Drawing Title:
SEALANT GRADE INTERIOR
WINDOW TRIM

Job Title:
insulation 1x16 board

gypsum bd.
16d ga. nails 24" o.c. vertical;
DOUBLE TOP PLATE min. 3" apart horizontal LIQUID APPLIED OR SHEET
MEMBRANE PAN FLASHING
SEALANT
BOARD & BATTEN SIDING
1X3 FLAT PAINT GRADE
Project: Sheet
EXTERIOR WINDOW TRIM
TYvek building paper (or eq.) 1.5"x2.25" vertical batten w/ HC1754
METAL FLASHING INSULATION
30d ga. nails @ 24" o.c. centered on batten

A4
Date:
5/8" PLYWOOD SHEATHING BOARD & BATTEN SIDING O/NEW 1/2" GYP. BD.
BUILDING WRAP (TYVEX OR EQ.) 12/12/2019
2x4 df STUD note: nails must penetrate solid SHEATHING & STUD Drawn By:
wood 1 1/2" min.; add blocking as needed
GENERAL NOTES - DECK AAP
NOTE: ALL WORK SHALL COMPLY WITH CARMEL MUNICIPAL CODE TITLE 15, 2016 CALIFORNIA BUILDING CODE (CBC) Scale:

8 TYPICAL EAVE DETAIL 6 siding detail 4 WINDOW SILL DETAIL (SIM.)


2016 CALIFORNIA RESIDENTIAL CODE (CRC), AND 17-14 OF THE CITY OF CARMEL'S STANDARD OPERATING GUIDANCE (SOG)
APPLICABLE 17-14 (SOG) PRESCRIPTIVE RESIDENTIAL DECKS & STAIRS REQUIREMENTS 1/8"=1'-0"