Drawing Index Vicinity Map General Construction Notes: Jobsite Location
Drawing Index Vicinity Map General Construction Notes: Jobsite Location
T1 TITLE SHEET
THIS PROJECT SHALL COMPLY WITH 2016 CALIFORNIA RESIDENTIAL CODE (CRC), CALIFORNIA G1 2016 CALIFORNIA GREEN BUILDING STANDARDS
MECHANICAL CODE (CMC), CALIFORNIA PLUMBING CODE (CPC), CALIFORNIA ELECTRICAL CODE (CEC),
G2 CMC CONSTRUCTION BEST MANAGEMENT PRACTICES & GEN. NOTES
CALIFORNIA FIRE CODE (CFC), CALIFORNIA ENERGY CODE (CENC) & CALIFORNIA GREEN BUILDING CODE
(CALGREEN).
ARCHITECTURAL
THESE DRAWINGS ARE PREPARED FOR USE BY A PROPERLY LICENSED AND CERTIFIED CONTRACTOR. A1 SITE & ROOF PLANS
ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE CODE AND ORDINANCE REQUIREMENTS A1.2 DRAINAGE PLAN
SET FORTH BY THE PREVAILING GOVERNING BODY. A1.3 EROSION & SEDIMENT CONTROL PLAN
PROJECT DATA
OWNER DESIGNER
Peter & Susan Loewy Angie Phares
SYMBOL KEY APN MAP 1 Oak Meadow Lane Hastings Construction, Inc.
Carmle, CA 93924 316 Mid Valley Center, Space 161
650-464-6862 Carmel, CA 93923
JOBSITE ploewy@peterloewy.com 831-620-0920
SECTION TAG PLAN CHECK LOCATION zakanaka@comcast.net design@hastingsconstruction.com
SECTION NUMBER/LETTER 1 REVISION NUMBER
a
BUILDING DATA:
a1 SHEET NUMBER Construction Type: VB
Fire Sprinklers: YES
LOT DATA:
APN: 010-121-021
C.M.U.
C.O.
CONCRETE MASONRY UNIT
CLEAN OUT
HVAC HEATING VENTILATION &
AIR CONDITIONING
R/W
RWD.
RIGHT OF WAY
REDWOOD
Total 542.1 sq. ft.
COL.
CONN.
COLUMN
CONNECTION
HW HOT WATER R.W.L. RAINWATER LEADER Total Allowed 556 sq. ft.
TITLE SHEET
CSMT. CASEMENT INS. INSULATION S.C. SOLID CORE
C.W. COLD WATER INT. INTERIOR SECT. SECTION
S.F. SQUARE FOOT/FEET
DBL. DOUBLE J.B. JUNCTION BOX SH SINGLE HUNG FLOOR AREA:
Drawing Title:
DET.
DF.
DETAIL
DOUGLAS FIR
JST. JOIST SHT.
SHWR.
SHEET
SHOWER Previously Approved:
KIT. KITCHEN SIM. SIMILAR
Entry Level 784 sq. ft.
Job Title:
DIA. OR Ø DIAMETER
DIM. DIMENSION KP KICKER POST SLD SLIDER
D.S.
DRY
DOWNSPOUT
DRYER
KS KING STUD SLD. GL. DR.SLIDING GLASS DOOR
SPECS. SPECIFICATIONS
Lower Level/Garage 748 sq. ft.
DW
DWG
DISHWASHER
DRAWING
LAV
LIN.
LAVATORIES
LINEN
SQ.
SQ.FT.
SQUARE
SQUARE FEET
Total 1,532 sq. ft.
LT. LIGHT STD. STANDARD
EA. EACH STL. STEEL
ELEC. ELECTRICAL MAT.
MAX.
MATERIAL
MAXIMUM
STOR. STORAGE Proposed: Sheet
ELEV. ELEVATION STRUCT. STRUCTURAL Project:
ENCL. ENCLOSURE M.B.
MECH.
MACHINE BOLT
MECHANICAL
SS STAINLESS STEEL Entry Level 996 sq. ft. HC1754
EQ EQUAL SYM. SYMMETRICAL
EXH. EXHAUST M.A. MEDICINE CABINET Lower Level/Garage 748 sq. ft. (reduced) Date:
MFR. MANUFACTURER
T1
EXP. EXPANSION TB TOWEL BAR
EXIST. OR (E) EXISTING MIN. MINIMUM TEL. TELEPHONE Total 1,744 sq. ft. 12/12/2019
EXT. EXTERIOR MISC. MISCELLANEOUS TEMP. TEMPERED
MTD. MOUNTED THRSH. THRESHOLD Total Allowed 1800 sq. ft. Drawn By:
FBRGL. FIBERGLASS T&G TONGUE & GROOVE
FD FLOOR DRAIN (N) NEW T.O.F. TOP OF FOOTING
FND. FOUNDATION N.I.C. NOT N CONTRACT T.O. TOP OF AAP
F.F. FINISH FLOOR NO. OR # NUMBER T.O.P. TOP OF PLATE Scale:
F.G. FINISH GRADE N.T.S. NOT TO SCALE T.O.S. TOP OF SLAB
FLR. FLOOR T.O.W. TOP OF WALL 1/8"=1'-0"
FL. FLUORESCENT O/ OVER TP TOILET PAPER
2016 GREEN BUILDING STANDARDS CODE
Revision Issue Date
4. Meet the California Department of Public Health, Standard Method for the Testing and Evaluation
CHAPTER 3 referenced in Table 1701.1 of the California Plumbing Code. 4.502.1 Definitions. TABLE 4.504.1 of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,
GREEN BUILDING ADHESIVE VOC LIMIT 1, 2 Version 1.1, February 2010 (also known as Specification 01350).
SECTION 4.304 OUTDOOR WATER USE AGRIFIBER PRODUCTS: Agrifiber products include wheatboard, strawboard, Less Water and Less Exempt Compounds in Grams per Liter
4.304.1 Outdoor potable water use in landscape areas. After December 1, 2015, new panel substrates and door cores, not including furniture, fixtures and
SECTION 301 GENERAL 4.504.5 Composite wood products. Hardwood plywood, particleboard and medium density fiberboard
residential developments with an aggregate landscape area equal to or greater than equipment (FF E) not considered base building elements. ARCHITECTURAL APPLICATIONS VOC LIMIT
301.1 Scope. Buildings shall be designed to include the green building measures specified composite wood products used on the interior or exterior of the building shall meet the requirements for
500 square feet shall comply with one of the following options:
as mandatory in the application checklists contained in this code. Voluntary green formaldehyde as specified in ARB s Air Toxics Control Measure for Composite Wood (17 CCR 3120 et seq.),
1. A local water efficient landscape ordinance or the current California COMPOSITE WOOD PRODUCTS: Composite wood products include hardwood Indoor carpet adhesives 50
building measures are also included in the application checklists and may be included by or before the dates specified in those sections, as shown in Table 4.504.5.
Department of Water Resources Model Water Efficient Landscape Ordinance plywood, particleboard and medium density fiberboard. Composite wood Carpet pad adhesives 50
in the design and construction of structures covered by this code, but are not required
(MWELO), whichever is more stringent or 2. Pro ects with aggregate landscape products does not include hardboard, structural plywood, structural panels, Outdoor carpet adhesives 150
unless adopted by a city, county, or city and county as specified in Section 101.7. 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the
areas less than 2,500 square feet may comply with the MWELO s Appendix D structural composite lumber, oriented strand board, glued laminated timber, Wood flooring adhesive 100 enforcing agency. Documentation shall include at least one of the following:
Prescriptive Compliance Option. prefabricated wood I- oists or finger ointed lumber, all as specified in California Rubber floor adhesives 60
301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 1. Product certifications and specifications.
Notes: 1. The Model Water Efficient Landscape Ordinance (MWELO) and Code of Regulations (CCR), Title 17, Section 3120.1(a). Note: See CCR, Title 17,
shall be applied to additions or alterations of existing residential buildings where Subfloor adhesives 50 2. Chain of custody certifications.
supporting documents are available at: Section 3120.1
the addition or alteration increases the building s conditioned area, volume, or Ceramic tile adhesives 65 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17,
http: www.water.ca.gov wateruseefficiency landscapeordinance
si e. The requirements shall apply only to and or within the specific area of the VCT and asphalt tile adhesives 50 Section 3120, et seq.).
2. A water budget calculator is available at: http: DIRECT-VENT APPLIANCE: A fuel-burning appliance with a sealed combustion
addition or alteration. Drywall and panel adhesives 50 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood
APN: 010-121-021
by more than one showerhead, the combined flow rate of all showerheads the relative humidity level in that range. 2. Public utility training programs.
and or other shower outlets controlled by a single valve shall not exceed 2.0 6. Information about water-conserving landscape and irrigation design and 4.504.3 Carpet systems. All carpet installed in the building interior shall meet the 3. Training programs sponsored by trade, labor or statewide energy consulting or verification
gallons per minute at 80 psi, or the shower shall be designed to allow only controllers which conserve water. 7. Instructions for maintaining gutters and testing and product requirements of one of the following: organi ations.
APN:
one shower outlet to be in operation at a time. downspouts and the importance of diverting water at least 5 feet away from 1. Carpet and Rug Institute s Green Label Plus Program. 4. Programs sponsored by manufacturing organi ations.
Note: A hand-held shower shall be considered a showerhead. 2. California Department of Public Health, Standard Method for the Testing 5. Other programs acceptable to the enforcing agency.
the foundation. 8. Information on required routine maintenance measures, TABLE 4.504.2 and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources
including, but not limited to, caulking, painting, grading around the building, SEALANT VOC LIMIT
4.303.1.4 Faucets. Using Environmental Chambers, Version 1.1, February 2010 (also known as 702.2 Special inspection. [HCD] When required by the enforcing agency, the owner or the responsible entity
Drawing Title:
4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of residential Specification 01350.) acting as the owner s agent shall employ one or more special inspectors to provide inspection or other duties
. Information about state solar energy and incentive programs available.
lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi. The 3. NSF ANSI 140 at the Gold level. necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to
10. A copy of all special inspection verifications required by the enforcing agency or
SEALANTS VOC LIMIT the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In
ob Title:
minimum flow rate of residential lavatory faucets shall not be less than 0.8 this code. 4. Scientific Certifications Systems Indoor Advantage Gold.
gallons per minute at 20 psi. addition to other certifications or qualifications acceptable to the enforcing agency, the following
Architectural 250 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall certifications or education may be considered by the enforcing agency when evaluating the qualifications of
4.410.2 Recycling by occupants. Where 5 or more multifamily dwelling units are
4.303.1.4.2 Lavatory faucets in common and public use areas. The maximum Marine deck 760 meet the requirements of the Carpet and Rug Institute s Green Label program. a special inspector:
constructed on a building site, provide readily accessible area(s) that serves all
flow rate of lavatory faucets installed in common and public use areas Nonmembrane roof 300 1. Certification by a national or regional green building program or standard publisher.
buildings on the site and is identified for the depositing, storage and collection of
(outside of dwellings or sleeping units) in residential buildings shall not Roadway 250 4.504.3.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 2. Certification by a statewide energy consulting or verification organi ation, such as HERS raters, building
non-ha ardous materials for recycling, including (at a minimum) paper, corrugated
exceed 0.5 gallons per minute at 60 psi. Single-ply roof membrane 450 4.504.1. performance contractors, and home energy auditors.
cardboard, glass, plastics, organic waste, and metals, or meet a lawfully enacted local
Other 420 3. Successful completion of a third party apprentice training program in the appropriate trade. Pro ect: Sheet
recycling ordinance, if more restrictive.
4.303.1.4.3 Metering faucets. Metering faucets when installed in residential 4.504.4 Resilient flooring systems. Where resilient flooring is installed, at least 80 4. Other programs acceptable to the enforcing agency.
Exception: Rural urisdictions that meet and apply for the exemption in Public
Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the pro ect
HC1754
buildings shall not deliver more than 0.25 gallons per cycle. SEALANT PRIMERS percent of floor area receiving resilient flooring shall comply with one or more of
Resources Code Section 4264 .82 (a)(2)(A) et seq. are not required to comply with
the following: they are inspecting for compliance with this code.
G1
the organic waste portion of this section. Date:
4.303.1.4.4 Kitchen faucets. The maximum flow rate of kitchen faucets shall not Architectural 1. Products compliant with the California Department of Public Health, 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in
exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily Nonporous 250 Standard Method for the Testing and Evaluation of Volatile Organic California according to the Home Energy Rating System (HERS). 12/12/2019
Division 4.5 ENVIRONMENTAL QUALITY
increase the flow above the maximum rate, but not to exceed 2.2 gallons per Porous 775 Chemical Emissions from Indoor Sources Using Environmental Chambers, Drawn By:
minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per Version 1.1, February 2010 (also known as Specification 01350), certified as a SECTION 703 VERIFICATIONS
SECTION 4.501 GENERAL Modified bituminous 500
minute at 60 psi. CHPS Low-Emitting Material in the Collaborative for High Performance 703.1 Documentation. Documentation used to show compliance with this code shall include but is not limited
4.501.1 Scope. The provisions of this chapter shall outline means of reducing the Marine deck 760 AAP
Note: Where complying faucets are unavailable, aerators or other means Schools (CHPS) High Performance Products Database. to, construction documents, plans, specifications, builder or installer certification, inspection reports, or
quantity of air contaminants that are odorous, irritating and or harmful to the Other 750 other methods acceptable to the enforcing agency which demonstrate substantial conformance. When Scale:
may be used to achieve reduction. 4.303.2 Standards for plumbing fixtures comfort and wellbeing of a building s installers, occupants and neighbors. 2. Products certified under UL GREENGUARD Gold (formerly the Greenguard
and fittings. Plumbing fixtures and fittings shall be installed in accordance specific documentation or special inspection is necessary to verify compliance, that method of compliance 1/8"=1'-0"
Children Schools program).
with the California Plumbing Code, and shall meet the applicable standards will be specified in the appropriate section or identified in the application checklist.
SECTION 4.502 DEFINITIONS 3. Certification under the Resilient Floor Covering Institute (RFCI) FloorScore
program.
Revision/Issue Date
APN: 010-121-021
sediment if construction entrance/exit is clogged adjacent to the bottom of the slope, prior to
prevent runoff from leaving the construction site. project at locations designated by the RE or - Staples used to fasten the fence fabric to the - a minimum 6 in. overlap and both ends securely
with sediment. Standards and Specifications: installing silt fence. Additional protection may
- Route runoff from stabilized entrances/exits through disposed of outside the highway right-of-way in stakes should be not less than 1.75 in. long and fastened to the post.
- Keep all temporary roadway ditches clear. Fiber Roll Materials: be a chain link fence or a cable fence.
a sediment trapping device before discharge. conformance with the Standard Specifications. should be fabricated from 15 gauge or heavier - The trench should be backfilled with native
- Check for damage and repair as needed. Fiber rolls shall be either: - For slopes adjacent to sensitive receiving waters
wire. The wire used to fasten the tops of the stakes material and compacted.
Drawing Title:
required performance, and site conditions. Do not - Remove gravel and filter fabric at completion of - Roll length of erosion control blanket into a Standard vs. Heavy Duty Silt Fence Heavy-Duty Silt Fence: slope, but should be constructed as far from the
use asphalt concrete (AC) grindings for stabilized construction tube of minimum 8 in diameter. Standard Silt Fence: - Some silt fence has a wire backing to provide toe of the slope as practicable. Silt fences close
- Bind roll at each end and every 4 ft along length
Job Title:
construction access/roadway. - Generally applicable in cases where the slope of additional support, and there are products that
of roll with jute-type twine. to the toe of the slope will be less effective and
- If aggregate is selected, place crushed aggregate area draining to the silt fence is 4:1 (H:V) or less. may use prefabricated plastic holders for the more difficult to maintain.
over geotextile fabric to at least 12 in. depth, or - Used for shorter durations, typically 5 months or silt fence and use metal posts or bar
Installation: - Construct the length of each reach so that the
place aggregate to a depth recommended by a less reinforcement instead of wood stakes. If bar
- Slope inclination of 1:4 or flatter: fiber rolls change in base elevation along the reach does
geotechnical engineer. A crushed aggregate - Area draining to fence produces moderate reinforcement is used in lieu of wood stakes, use
shall be placed on slopes 6.0 m apart. not exceed 1/3 the height of the barrier; in no case
greater than 3 in. but smaller than 6 in. should be sediment loads. number four or greater bar. Provide end
- Slope inclination of 1:4 to 1:2: fiber rolls shall be should the reach exceed 500 ft.
used. Heavy Duty Silt Fence: protection for any exposed bar reinforcement
placed on slopes 4.5 m apart. - Cross barriers should be a minimum of 1/3 and a
- Designate combination or single purpose entrances - Use is generally limited to 8 months or less. for health and safety purposes.
and exits to the construction site. - Slope inclination 1:2 or greater: fiber rolls shall maximum of ½ the height of the linear barrier. Project: Sheet
- Area draining to fence produces moderate
- Require that all employees, subcontractors, and be placed on slopes 3.0 m apart. sediment loads. Installation Guidelines – Traditional Method: HC1754
suppliers utilize the stabilized construction access. - Stake fiber rolls into a 50 to 2 to 4 in trench. - Heavy duty silt fence usually has 1 or more of the - Silt fences are to be constructed on a level
G2
- Implement SE-7, Street Sweeping and Vacuuming, as - drive stakes at the end of each fiber roll and following characteristics, not Date:
contour. Sufficient area should exist behind the
needed. spaced space stakes 4 ft maximum on center if possessed by standard silt fence.
- All exit locations intended to be used for more than installed as shown on Pages 1.3 of this set.
fence for ponding to occur without flooding or 12/12/2019
- Fence fabric has higher tensile strength. overtopping the fence.
a two-week period should have stabilized - Use wood stakes with a nominal classification of 19 - Fabric is reinforced with wire backing or Drawn By:
- A trench should be excavated approximately 6 in.
construction entrance/exit BMPs. by 19 mm (43" by 43" and minimum length of 24 in. additional support. wide and 6 in. deep along the line of the
- If more than one fiber roll is placed in a row, the - Posts are spaced closer than pre-manufactured, - proposed silt fence (trenches should not be AAP
rolls shall be overlapped; not abutted. standard silt fence products. excavated wider or deeper than necessary for Scale:
- Posts are metal (steel or aluminum) - proper silt fence installation).
Removal:
- Bottom of the silt fence should be keyed-in a
1/8"=1'-0"
- Fiber rolls are typically left in place. Materials: minimum of 12 in.
- If fiber rolls are removed, collect and dispose Standard Silt Fence:
- Silt fence material should be woven geotextile with
9x9 catch basin downspout w/ Revision/Issue Date
PROPERTY LINE at downspout splash block
4" solid pipe; 2% SLOPE TOWARDS RAIN GARDEN - TYPICAL 4" solid pipe (permeable)
(permeable)
ds
7'-6"
ds ds
(permeable)
ds
rain
garden
PROPERTY LINE
garden
driveway
(permeable)
permeable deck ds
PROPERTY LINE
12'
6'
ds ds
35 SQ. FT rain 4" solid pipe; 2% SLOPE TOWARDS RAIN GARDEN - TYPICAL
garden
SETBACK
3'
PROPERTY LINE
NOTES:
ALL INFILTRATION SYSTEM(S) SHALL BE DESIGNED IN ACCORDANCE WITH
CARMEL municipal code (cmc) standard operating guidance
(sog) 17-07 for private STORMWATER DRAINAGE SYSTEMS.
DRAINAGE PLAN
APN: 010-121-021
refer to https://ci.carmel.ca.us/pod/private-drainage-systems
for approved list of rain garden plants.
Drawing Title:
Job Title:
Runoff shall be directed away from building foundations.
A1.2
12/12/2019
Drawn By:
AAP
Scale:
1/8"=1'-0"
PROPERTY LINE
Revision/Issue Date
EQUIPMENT STORAGE,
BUILDING
MATERIALS/STAGING,
WASHOUT AREAS
10'
STABILIZED CONSTRUCTION ENTRANCE
(see detail tc-1)
PROPERTY LINE
PROPERTY LINE
CONCRETE
PUMP AREA
SC-5
SETBACK
3'
silt fence to surround entire site
PROPERTY LINE
"
48
APN: 010-121-021
Project Address & APN:
Drawing Title:
Job Title:
Project: Sheet
HC1754
Date:
A1.3
12/12/2019
Drawn By:
AAP
Scale:
1/8"=1'-0"
ADDITION PREVIOUSLY APPROVED
ELECTRICAL NOTES: 56'-1"
ELECTRICAL, LIGHTING & MECHANICAL DEVISES
SHOWN ON DRAWINGS INDICATES ARCHITECTURAL 16'-3" 9'-8" 12'-10" 7'-2" 3' 4'-9" 1'-4" 1' Revision/Issue Date
DESIGN INTENT ONLY. ELECTRICAL & MECHANICAL
12'-11" 3'-4"
SUBCONTRACTOR TO MEET WITH OWNER'S FINAL = NEW WALL
APPROVAL AND/OR REVISIONS.
= EXISTING WALL TO REMAIN
VERIFY PHONE & TV JACK LOCATIONS WITH OWNER
= EXISTING RETAINING
PRIOR TO INSTALLATION - TYPICAL.
WALL TO REMAIN
3'-6"
compliance with Section 150.0(k) in dn 110V DUPLEX OUTLET
ENTRY DECK
7' hdr. ht. 110V gfi DUPLEX OUTLET
150.0-B, as applicable.
single switch
1'-4"
1'-1"
csmt.
or vacancy sensor has been installed to
TO GRADE
comply with Section 150.0(k). RISE: 7.5" BATH dimmer switch
LIVING
6:12 SLOPE
3'
TREAD: 12"
6'-6"
3-way dimmer switch
Lighting controls shall comply with the
applicable requirements of Section 110.9.
NEW FAMILY ROOM dn RECESSED can LIGHT FIXTURE
NEW 36" HIGH metal
Luminaries recessed into ceilings shall meet
all of the following requirements:
RAILING - BALUSTERS
SPACED SO THAT A 4"
dn
slopped ceiling
door to be replaced
dn ENTRY P.R. wall mounted light fixture
GAS
13'-1"
SPHERE CANNOT PASS w/cased opening FUEL GAS
THROUGH - TYP.
A. Be Listed, as defined in Section 100.1,
for zero clearance insulation new gas fireplace DATA JACK (VERIFY CABLE TYPE)
PROVIDE BLOCKING & PANTRY
contact (IC) by Underwriters
23'-10"
23'-10"
ELECT. FOR TV 6:12 SLOPE TV JACK/CABLE
Laboratories or other nationally REF
recognized testing/rating
csmt.
previously approved
(n) shelves
remove windows UNLESS NOTED OTHERWISE. CONTRACTOR TO
to remain unchanged
B. Have a label that certifies that the VERIFY EXISTING ELECTRICAL CONDITIONS.
luminaire is airtight with air leakage 14'-6"
(n) 2x6 wall
MASTER BEDROOM
less than 2.0 CFM at 75 Pascals when
tested in accordance with ASTM E283.
NEW IPE DECK NEW 10070 BI-FOLD door SYSTEM KITCHEN DINING
12'
An exhaust fan housing shall not be DW GENERAL NOTES:
required to be certified airtight; and
C. Be sealed with a gasket or caulk THIS PROJECT SHALL COMPLY WITH 2016 CALIFORNIA
4'-8"
between the luminaire housing and RESIDENTIAL CODE (CRC), CALIFORNIA MECHANICAL CODE
MODELNUMBER
TRADENAME
MATERIAL
PRODUCT
ceiling, and shall have all air leak (CMC), CALIFORNIA PLUMBING CODE (CPC), CALIFORNIA
paths between conditioned and ELECTRICAL CODE (CEC), & CALIFORNIA ENERGY CODE
unconditioned spaces sealed with a (CENC), CALIFORNIA FIRE CODE (CFC).
gasket or caulk; and
1'-1"
CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS,
D. For recessed compact fluorescent MATERIALS, AND CONDITIONS PRIOR TO STARTING
1'-10"
luminaries with ballasts to qualify as CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE
1'-11"
high efficacy for compliance with DESIGNER OR OWNER PRIOR TO ORDERING MATERIALS.
Section 150.0(k), the ballasts shall
be certified to the Commission to CONTRACTOR TO PROTECT EXISTING CONDITIONS FROM
comply with the applicable DAMAGE, DUST, AND DEBRIS.
requirements in Section 110.9; and
MATERIALS PLANNED TO BE REUSED ARE TO BE
E. Allow ballast maintenance and PROTECTED FROM DAMAGE THROUGHOUT THE DEMOLITION
replacement to be readily PROCESS.
accessible to building occupants 10'-3" 12'-11" 1'-10" 1'-6" 9'-8" 12'-11" 17'-3"
from below the ceiling without CONTRACTOR IS RESPONSIBLE FOR COMPLETE FINAL
requiring the cutting of holes in the 25' 41'-4" DISPOSAL OF ALL CONSTRUCTION DEBRIS IN A MANNER
ceiling. CONSISTENT WITH ALL APPLICABLE FEDERAL, STATE AND
LOCAL LAWS.
RESIDENTIAL OUTDOOR LIGHTING PERMANENTLY
MOUNTED TO THE DWELLING shall follow the where new work adjoins existing, elements are to be
2
3) on ceiling where frame spacing exceeds 12" on
TIME SWITCH CONTROL OR BY ASTRONOMICAL TIME areas of buildings undergoing center.
CLOCK CONTROL THAT AUTOMATICALLY TURNS alterations or repairs that do not
10'-3"
THE OUTDOOR LIGHTING OFF DURING DAYLIGHT result in the removal of interior
DOOR & WINDOW NOTES:
BEDROOM 3/DEN
HOURS OR BY AN ENERGY MANAGEMENT UP
walls or ceiling finishes exposing the
CONTROL SYSTEM. structure, unless there is an attic,
1. all GLAZING subject to human impact SHALL
crawl space or basement available
ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. which could provide access for CONFORM to crc SECTIONS R308.3 & R308.4.
ALL 1220-VOLT 15 AND 20 AMPERE OR BRANCH building wiring without the removal of 1.1. GLAZING ADJACENT TO STAIRWAYS, LANDINGS
CIRCUITS SUPPLYING OUTLETS INSTALLED IN AND RAMPS WITHIN 36 INCHES HORIZONTALLY
24'-2"
ARC-FAULT CIRCUIT INTERRUPTER maintained in accordance with NFPA 720 and shall be verified by owner.
19'-5"
APN: 010-121-021
HAVE AFCI [210-12(B)] Section R315.1 shall be installed Outside of
each separate dwelling unit sleeping area in 4. window and door sizes shown for design
tamper resistant receptacles are required the immediate vicinity of the bedroom(s) (crc purposes only. actual window and door sizes
12'-4"
more than 5'-6" above the floor, outlets specifications. CONTRACTOR TO FIELD VERIFY
that are a part of a luminaire, outlets Carbon monoxide alarms shall receive SIZES AND SELECT NEAREST MANUFACTURER'S SIZES
dedicated to appliances that cannot be their primary power from the building PRIOR TO ORDERING.
Drawing Title:
easily moved and at outlets located in wiring where such wiring is served from a
attics. commercial source and shall be equipped
Job Title:
with a battery back-up. Alarm wiring shall
SMOKE DETECTORS: be directly connected to the permanent
verify existing smoke detectors or install building wiring without a disconnecting switch
new per below: other than as required for over-current
1. A smoke detector, approved and protection. (crc R315.1.2)
listed by the State Fire Marshal Exceptions:
pursuant to Section 13114, shall be 1. In dwelling units where there is no WINDOW SEAT
1'-7"
installed, in accordance with the Sheet
commercial power supply carbon Project:
manufacturer's instructions.
2. Smoke alarms shall be installed in
monoxide alarms may be solely HC1754
battery operated
each sleeping room and outside each 2. Other power sources recognized for 10' 12'-10" 17'-5" Date:
A2
separate sleeping area in the immediate use by NFPA 720 Where more than one
12/12/2019
LOWER LEVEL FLOOR PLAN
vicinity of the bedrooms (crc R314.3). carbon monoxide alarm is required
3. smoke alarms shall be interconnected to be installed within the dwelling unit Drawn By:
in such a manner that the activation of or within a sleeping unit the alarm
one alarm will activate all alarms. The shall be interconnected in a manner AAP
alarm shall be clearly audible in all that activation of one alarm shall Scale:
bedrooms over background noise
levels with all intervening doors
activate all of the alarms in the previously approved 1/8"=1'-0"
individual (crc R315.1.3).
closed (CRC R314.5). to remain unchanged
new class 'a' comp.
shingle roof w/2x fascia &
copper gutter - to match
previously approved Revision/Issue Date
ridge 104'-6" permitted structure - typ.
7'
3'
FAMILY RM. 90'-2" f.f. FAMILY RM. f.f. (90.16')
previously approved
to remain unchanged
PREVIOUSLY APPROVED UNDER PERMIT #17011 RV 01 PROPOSED DECK AND FAMILY ROOM ADDITION
12
6 SLOPE
3
A4
4
A4
7'
new class 'a' comp.
shingle roof w/2x fascia &
copper gutter - to match family rm. ridge 103'-6"
3'
previously approved
permitted structure - typ.
FAMILY RM. f.f.
MAIN ELECTRIC
PANEL LOCATION
APN: 010-121-021
- typical
r-30 insulation
8'-1" PLATE ht. 8
Drawing Title:
with 1/2" lag @
(NO CHANGED PROPOSED) 16" o.c. staggered
Job Title:
PROPOSED SOUTH ELEVATION (LEFT SIDE)
5
board & batten siding -
copper flashing a4 to match existing
as req'd
A3
JOISTS @ 16" o.c. w/ r-19 insulation 4" min. weep screed
2x blocking
12/12/2019
Drawn By:
7 AAP
a4 Scale:
A
FOUNDATION & FRAMING NOTES: REQUIRED. diaphragm & and the shear shall be MAKE ANGLED CUTS @ CORNERS, FOLD Revision/Issue Date
wood framing shall be in accordance w/ Cbc 2016 transferred according to cbc chapter 23. UP AND TEMPORARILY SECURE FLAP
chapter 23. PROVIDE G.I. FLASHING or copper AS REQUIRED. WITH FLASHING TAPE. TACK FLAP
PROVIDE WEATHERPROOFING FOR ALL EXPOSED provide 1
TEMPORARILY WITH SHEATHING TAPE
2" gypsum board at ceilings w/ 16" o.c.
STRUCTURAL ITEMS. AND FOLD OVER HEAD FLASHING
all framing lumber shall be douglas fir (u.n.o.) spacing & 58" gypsum board @ 24" o.c. spacing.
and shall have a 19% max moisture content at time
of install. DOUBLE ALL FLOOR JOISTS BELOW PARALLEL
Door & window headers are to be #2 material -
PARTITIONS W/ 16D NAILS @ 12" STAGGERED - TYPICAL. CAULK BACKSIDE OD FLANGE -
blocking shall be placed between bearing walls typically 4x12 df @ 6'-8" (u.n.o.).
ALL MUDSILLS TO BE 2X6 PT/DF W/ 58"X10" A.B. @ 4'-0" TOP & SIDES ONLY - WITH 100% 1.
which are not parallel to the joists. SILICONE OR POLYURETHANE
O.C. MAX. 12" FROM ENDS OR MUDSILL, MIN. 4 83" FROM cripple walls to be braced min. 4'-0" wide
ENDS TYP. bracing per 25 linear ft. of wall SEALANT. INSTALL WINDOW PER EXTERIOR
5
SUBFLOOR TO BE 8" CDX T&G PLYWOOD W/ FACE GRAIN MANUFACTURER'S SPECS. SHEATHING
ALL SOLE/SILL NAILING TO BE 16D @ 6" O.C. LAID PERPENDICULAR TO FLOOR JOISTS W/ STAGGERED
Rafters to be 2x8 df#2 @ 16" o.c.; ridge to be 2x10.
JOINTS; GLUE & NAIL W/ 16D NAILS @ 6" O.C.E. - TYPICAL. 2. WATER RESISTIVE
All metal connectors shall be simpson or eq. BARRIER
roof sheathing to be 58" cdx plywood; nailing: 8d @
CORNER PATCH
HEAD FLASHING:
ROUGH OPENING + 2X
4-16d @ corner laps WIDTH OF FLASHING + 2"
& cross wall laps
CRIPPLE STUDS
top plate
FLASHING: R.O. + 2X WIDTH
OF FLASHING - 1"
2X DF#2 studs HEADER HEADER
min.
3"
BLOCKING
8"
8"
ARCHITECTURAL DETAILS
CLASS 'A' ASPHALT ROOF SHINGLES (CERTAINTEED
OR EQ.); INSTALL PER MANUF. SPECS. stud
5/8" cdx plywood sheathing
2 LAYERS 30# FELT (OR SYNTHETIC
UNDERLAYMENT EQUIVLANT) building wrap (tyvex or eq) DUAL PANE WINDOW
APN: 010-121-021
screen
3/8" CDX PLYWOOD SHEATHING
Drawing Title:
SEALANT GRADE INTERIOR
WINDOW TRIM
Job Title:
insulation 1x16 board
gypsum bd.
16d ga. nails 24" o.c. vertical;
DOUBLE TOP PLATE min. 3" apart horizontal LIQUID APPLIED OR SHEET
MEMBRANE PAN FLASHING
SEALANT
BOARD & BATTEN SIDING
1X3 FLAT PAINT GRADE
Project: Sheet
EXTERIOR WINDOW TRIM
TYvek building paper (or eq.) 1.5"x2.25" vertical batten w/ HC1754
METAL FLASHING INSULATION
30d ga. nails @ 24" o.c. centered on batten
A4
Date:
5/8" PLYWOOD SHEATHING BOARD & BATTEN SIDING O/NEW 1/2" GYP. BD.
BUILDING WRAP (TYVEX OR EQ.) 12/12/2019
2x4 df STUD note: nails must penetrate solid SHEATHING & STUD Drawn By:
wood 1 1/2" min.; add blocking as needed
GENERAL NOTES - DECK AAP
NOTE: ALL WORK SHALL COMPLY WITH CARMEL MUNICIPAL CODE TITLE 15, 2016 CALIFORNIA BUILDING CODE (CBC) Scale: