You are on page 1of 1

Electricfor Insulation thickness Date 20-10-2020

Design Sheet 1 of 1
1.0 Heat transfer from insulation outer surface to air
Insulation outer surface temp. Ts °C 50
Ambient air temperature Ta °C 30
Average temperature °C 40

Gr=gβ/ѵ^2(Ts-Ta)D^3
gβ/ѵ^2 101000000
Outer diameter of pipe Dis mm 60.3
Insulation thickness mm 150
Outer diameter of insulation Dos mm 360.3
m 0.3603

Grashof number Gr 94480929.2

Prandtl number Pr 0.71

GrPr 67081459.7

Nu=(0.6+0.387(GrPr)^(1/6)/(1+(0.559/Pr)^(9/16))8/27)^2

Nusselt number Nu 50.1

Thermal conductivity of air ka W/m-K 0.0265

Heat transfer coefficient h W/m2-K 3.7

Length of pipe L m 1.0


Π 3.14
Area of insulation outer surface A m2 1.13
A=Π*Dos*L
Rate of heat transfer q1 W 83.45
q1=h*(Ts-Ta)*A

2.0 Heat transfer from pipe outer surface to insulation outer surface
Rate of heat transfer q2
q2=2Πk(Ti-Ts)/(2.3*Log(Dos/Dis)

Thermal conductivity of Rockwool k W/m.°K 0.07

Pipe inside temperature Ti °C 400

Rate of heat transfer q2 W 86.13

Remarks: q1=q2 Insulation thickness is 150 mm.


Prepared: DRS Rev 0
Checked: DRS Date 20-10-2020