9 AirBASIC Electronic Controller


9.1 Introduction 9.3.1 Display
The AirBASIC Controller is designed a) When the compressor is powered, the display
specifically for use in CompAir rotary screw air on the controller shows the “OFF” message.
compressors. These instructions will enable b) If a remote control is connected to the remote
you to operate the AirBASIC controller START/STOP input and its contact is open,
correctly and safely. that is, in a STOP condition, the display
shows the “---” message.
9.2 Safety
c) In normal operation, the controller display
Always read the safety instructions in shows the oil temperature value.
section 2 of this manual before starting work.
Note: The AirBASIC controller display can
In addition to these instructions, the local only show up to 3 digits. Numbers with 4 or 5
regulations in your country may impose digits are indicated by the illumination of LEDs
additional requirements that must be x10 or x100, which are termed "10 multiplying
observed. factor" and "100 multiplying factor"
respectively. The following examples show
how the LEDs work.
9.3 Description
1 2 Value to
Example Display LED LED
be
No. shows x10 x100
displayed

ON 3 1 697 697 OFF OFF


x10 x100
2 6970 697 ON OFF
OFF
3 69700 697 OFF ON

Reset
9.3.2 Button Functions
• ON: Switches on the compressor.
a03 A01 A03 A04 S. • OFF: Switches off the compressor.
• RESET: Resets alarms and displays hour
meter.
SM 1588 9.3.3 Indicator Functions
• x10 LED (green): indicates that the 10
Fig. 9.1 - AirBASIC Control Panel
multiplying factor is active.
1. LCD Display (3 Digits/7 Segments)
• x100 LED (green): indicates that the 100
2. LED Status Indicators (3 Green)
multiplying factor is active.
3. Control Pushbuttons (3)
• LED (green), steadily on: indicates load
The Control Panel is mounted on the operation mode.
compressor. It is used to operate the
compressor and observe system status using • LED (green), flashing: indicates unload
the LCD display, LED status indicators and operation mode.
buttons.
The Control Panel displays a comprehensive
9.4 Compressor Operation with the
overview of the compressor status and allows AirBASIC Controller
access to operational parameters such as 9.4.1 Starting The Compressor
alarm set points.
The starting procedure depends on the
current status of the compressor.
a) Starting the compressor in “OFF” status

DL105AA 41
9 AirBASIC Electronic Controller CompAir

The “OFF” message on the controller display When the compressor is started (either locally
indicates that the compressor is properly via the ON button or from a remote location),
powered, waiting to be started, and that the the controller performs a number of checks at
last switch-off was caused by pressing the the inputs to make sure that there are no
“OFF” push button on the controller (local conditions likely to pose hazards to the
switch-off). machine and/or the operators.
To start the compressor, use local controls, If abnormalities are found, the compressor
that is, press the “ON” button on the control start-up is inhibited and an error message
unit. appears on the controller display. If no
abnormality is found, the compressor is
Note: In this condition, opening and closing
allowed to start.
the remote contact will produce no effect
whatsoever. When start-up is initialised (and no alarms are
active), the controller checks the status of the
b) Starting the compressor in “---” status
line pressure switch contact. If the pressure
The “---” message on the controller display switch contact is closed, the motor is started
indicates that the compressor is properly according to the star/delta start-up sequence.
powered, waiting to be started, and that the If the pressure switch contact is open
remote START/STOP contact is in the OPEN (pressure in the network ), the compressor
position (STOP position). goes into stand-by mode and the motor is not
started until the network pressure drops to the
To start the compressor, use the relevant
load value level.
procedure described below, depending on
how the last switchoff occurred. When the load value level is reached, the
pressure switch contact closes. The relay
- If the compressor was running (no matter
outputs relating to the line and star contactors
whether loaded, unloaded or in stand-by) and
are energised for the equivalent of the star
was then switched off remotely, the “---”
time (parameter P06 - default 5 s). When the
message appears. To restart the compressor,
star time has elapsed, the controller switches
close the remote contact again.
from star to delta with a ‘safety’ delay (applied
- If the compressor was switched off locally, between the release of the star contactor and
that is, by pressing the OFF button on the the coming into operation of the delta
controller, and the remote contact was then contactor). This delay is equivalent to the time
opened AFTER the switch-off, the “---” value set up on the star/delta switching timer
message appears. (parameter P07 - default 20 ms). When the
switching timer has elapsed, the outputs
1. To restart the compressor, close the remote relating to the line and delta contactors are
contact. energised.
2. Press the ON button on the controller. In order to stabilise the motor’s rotation
This feature allows the operation of the speed, the load solenoid valve is energised
compressor to be disabled from a remote with a delay that is equivalent to the time
position in order to prevent unauthorised value set up on the “launch timer” parameter
personnel from starting the compressor with (parameter P08 - default 2s). The delay is in
the push buttons on the controller. relation to the closure of the delta contactor.
Once the solenoid valve has been energised,
Warning: If the remote control feature is to the compressor enters into load-operation
be used with the START/STOP contact stage.
connected to the controller, it is strongly
advisable to affix a sign by the machine 9.4.2 Controlling The Compressor Load/Unload
warning that the compressor may be Operation
started at any time from a remote location.
When the compressor is on load, the LED
Note: Machine start and machine restart on the right hand side of the display lights
operations can be performed via a control steadily. When the pressure reaches the set
device other than the one provided, as long as value of the pressure switch, the pressure
this does not pose any hazards. switch contact opens and the compressor
switches to unload operation for a period of
c) Compressor Start-up Process
time that is equivalent to the time value set up

42 DL105AA
CompAir AirBASIC Electronic Controller 9

on the “unload time” timer (parameter P09 - 9.4.3 Switching Off The Compressor
default 3 min).
The compressor can be switched off locally or
During the unload phase, the LED flashes remotely (if a remote contact is connected to
to indicate that the compressor is running in the appropriate terminals). In both cases,
unload mode. When the timer has elapsed, when the machine is commanded OFF, the
the motor is stopped. As soon as the pressure controller de-energises all the relay outputs
drops to the load value that is set up on the controlling the contactors as well as the
pressure switch, the motor is restarted solenoid valve, thereby causing the
automatically via a star/delta sequence. When compressor to stop immediately.
the motor is stopped, the LED is turned off The control unit activates a safety (“blowdown
and if no alarms are active, the value of the oil time”) timer (parameter P10 - default 20 s) to
temperature appears on the display. prevent the compressor from restarting with
If the pressure drops to the load value level pressure in the inner tank when the OFF
before the unload timer has elapsed, the button is pressed (or when the remote
compressor immediately switches back to start/stop contact is opened). Compressor
load mode without any stopping of the motor. restart is inhibited throughout the count down
When the “Unload time” timer elapses, the of the blowdown time. Pressing the ON button
motor stops. The oil temperature remains or closing back the remote start/stop contact
steady on the display to indicate that the during blow-down produces no effect
machine is not OFF but is still in stand-by whatsoever.
condition. The blow-down stage is indicated by the
Warning: Be very careful, as in this flashing of LED x10. When the count down of
condition, the compressor will restart the “blow-down time” is over, LED x10 is
without prior notice as soon as the turned off. At that point, you can restart the
pressure drops to the load value level. compressor.
See fig. 9.2 for an example of the operating
cycle.

Motor running
pressure
Network pressure

UNLOAD UNLOAD STOP

Unload pressure

Load pressure

LOAD LOAD

START
UNLOAD TIME
Motor running

Motor OFF

SM 1575 time

Fig. 9.2 - Example Of The Operating Cycle

DL105AA 43
9 AirBASIC Electronic Controller CompAir

9.5 Timers Note: When a maintenance pre-alarm


message is manually reset, it will no longer
The AirBASIC Controller has two kinds of appear as long as the compressor is ON.
control information: timers and parameters.
There are two kinds of timers: maintenance Maintenance timers can only be reset when
timers (for viewing and resetting) and the compressor is OFF. When the compressor
operation timers (for viewing only). is OFF, the display shows an “OFF” or “---”
message, depending on the conditions
9.5.1 Viewing maintenance timers described in section 11.7.1 a) - "Display".
Maintenance timers count the time until the a) To view the first maintenance code (S01),
next maintenance operation on the following press and hold RESET button for about 3
items (maintenance code number and seconds.
meaning):
b) To reset the first maintenance code, press
• S01 = oil change and hold the RESET button for about 3
• S02 = air filter replacement seconds. The value is replaced by the default
value and the second maintenance code will
• S03 = oil filter replacement be displayed.
• S04 = separator filter replacement c) If you do not wish to reset the first hour meter,
• S06 = general maintenance. but want to switch immediately to the second
one instead, press and release the RESET
The maintenance timers can be viewed when button. The second maintenance code
the compressor is ON. When the compressor appears on the display, and its timer value will
is ON, the display will normally show the oil be visible after 1 second. To reset the value,
temperature value, unless an alarm is ON. press and hold the RESET button for about 3
a) To view the first maintenance code, S01 (oil seconds.
change), press and release the RESET d) Scroll through all maintenance timers as
button. The value for remaining hours will be described above, resetting their values if
displayed automatically after about 1 second. necessary, until the “OFF” or “---” message is
b) To view the second maintenance code, S02 displayed again.
(air filter replacement), press and release the 9.5.3 Viewing operating timers
RESET button again. The value for remaining
hours will be displayed automatically after Operating timers count the total operating
about 1 second. hours (h-t) and total hours on load (h-L) of the
compressor. The operating timers are
c) To view the rest of the maintenance codes, available for viewing when the compressor is
press and release the RESET button again. ON.
d) To return to the oil temperature display, scroll a) To view the “h-t” message, press and hold the
through the remaining maintenance codes RESET button for 3 seconds. Total operating
(S03, S04, S06). hours will be displayed.
Notes: b) To view the “h-L” message, press and release
(i) Maintenance timer counting (parameters the RESET button again. Total hours on load
P12 - P 16) is based on motor running hours. will be displayed.
It works like a countdown; when the
countdown is at 0, it will continue with the Notes:
negative sign, and the first display will show (i) The counting of hours on load is based on
the “-” symbol. the length of time for which the relay
supplying the load/unload solenoid valve is
(ii) Maintenance hours are stored to the closed; the counting of total operating hours is
memory every 15 minutes; if a power failure based on the length of time for which the line
occurs during compressor operation, the contactor supplying the motor is closed.
entire 15 minute fraction will be lost.
(ii) Operating time is stored to the memory
9.5.2 Resetting maintenance timers every 15 minutes; if a power failure occurs
during compressor operation, the entire 15
minute fraction will be lost.

44 DL105AA
CompAir AirBASIC Electronic Controller 9

9.6 Parameters e) To edit the value of another parameter, scroll


up or down the list until the ID Code of the
The parameters allow the user to change the desired parameter is displayed, and repeat
operating parameters of the compressor, such step d).
as the maintenance pre-alarm hours or
maximum restarts per hour. The default f) To exit the programming mode after adjusting
values for the adjustable parameters are listed all the desired parameters, press and hold the
in the table on the next page. RESET button for about 3 seconds. At this
stage, the OFF or “---” message appears on
The parameters can only be adjusted when the display and all the changes made to the
the compressor is stopped. parameters are activated.
a) To enter the parameter programming mode, Notes:
simultaneously press and hold the OFF and (i) If no button is pressed for 60 seconds
RESET buttons for 3 seconds. After 3 during the programming procedure, the
seconds, the code of the first parameter, P01, controller will automatically exit the
will appear on the display. programming mode, switch back to OFF and
b) To scroll up or down the parameter list, press store all the changes.
ON or OFF buttons respectively. (ii) If the upper or lower threshold of a
c) To view the current value of a parameter, parameter is reached when editing a
press the RESET button. parameter, the value that appears on the
display will flash to warn that the min. or max.
d) To edit the displayed value, press ON value for that parameter has been reached.
(increase) or OFF (decrease) buttons. Once
the desired value has been entered, press The following table (fig. 9.3) contains all the
RESET button to store the value and to return available parameters with their respective
to the parameter list. codes, descriptions, units of measurement,
possible values and default values.

Param.code Description Unit Range Default


P01 MAX probe temperature range °C 130 - (P02+2) 130
P02 High oil temperature alarm threshold °C (P01-2) - (P03+2) 110
P03 High oil temperature pre-alarm threshold °C (P02-2) - (P04+2) 105
P04 Low oil temperature alarm threshold °C (P03-2) - -10 -10
P05 Oil temperature probe calibration °C -10 - +10 0
P06 Star time s 2 - 10 5
P07 Star-delta switch timer ms 10 - 50 20
P08 Launch timer s 1-5 2
P09 Unload time min 0 - 10 0
P10 Blow-down time s 1 - 60 20
P11 Max restarts per hour / 1 - 60 60
P12 Air filter maintenance pre-alarm hours h 100 - 3000 1500
P13 Oil filter maintenance pre-alarm hours h 100 - 9900 1500
P14 Separator filter maintenance pre-alarm hours h 100 - 9900 1500
P15 Oil maintenance pre-alarm hours h 100 - 9900 1500
P16 General maintenance pre-alarm hours h 100 - 1000 500
P17 Automatic restart status / 0-1 0
P18 Alarm relay function / 0-2 0

Fig. 9.3 - Table of Parameters

DL105AA 45
9 AirBASIC Electronic Controller CompAir

9.6.1 Parameter descriptions the motor’s rotation speed subsequent to


the star-delta switching.
P01 - MAX probe temperature range
– In normal conditions, this parameter needs
– Provides the highest value for oil
no adjustment.
temperature reading.
P09 - Unload time
– No adjustment is necessary.
– Defines the duration of the unload operation
P02 - High oil temperature alarm threshold
interval, at the end of which the controller
– Defines the high oil temperature alarm will power off the motor.
value. As soon as this value is reached, a
– Unload operation is identified by a flashing
dedicated alarm message (A01) appears on
LED.
the display.
P10 - Blow-down time
P03 - High oil temperature pre-alarm
threshold – Defines the duration of the blow-down
interval after the compressor has been
– Defines the high oil temperature pre-alarm
powered off. Its purpose is to prevent any
value. As soon as this value is reached, the
restarts of the compressor while pressure is
compressor stops and a dedicated alarm
still in the tank.
message (a03) appears on the display, but
the normal operation of the compressor is – The blow-down condition is identified by a
not interrupted. flashing x10 LED. In this condition, motor
start-up is inhibited for the set time interval.
P04 - Low oil temperature alarm threshold
P11 - Max restarts/hour
– Defines the low oil temperature alarm value.
Under this value, compressor start-up is – Defines the maximum number of permitted
inhibited and a dedicated alarm message start-ups per hour. Its purpose is to protect
(A34) appears on the display. the motor from damage. When the set
number of restarts is reached, the motor will
P05 - Oil temperature probe calibration
not stop for the rest of the following hour
– Compensates for possible reading errors and the compressor will work without
(either by excess or by defect) of the interruption, switching from load to unload
temperatureprobe due to a defective probe. and vice versa.
– In normal conditions, this parameter needs – This condition is identified by the
no adjustment. simultaneous flashing of LEDs x10, x100
and .
P06 - Star time
– At the end of the hour period, the counter is
– Defines how long the system should run in
reset and the motor will be able to stop at
star configuration during motor start-up.
the end of the unload phase.
– In normal conditions, this parameters needs
P12 - Air filter maintenance pre-alarm
no adjustment.
hours
P07 - Star-delta switch timer
– Defines the air filter change countdown
– Defines the delay between the release of timer value.
the star contactor and the coming into
– When the set timer has elapsed, the
operation of the delta contactor, during the
controller will warn the operator that
switching stage.
maintenance is needed by showing a
– In normal conditions, this parameter needs dedicated warning message (S02) on the
no adjustment. display.
P08 - Launch timer P13 - Oil filter maintenance pre-alarm
hours
– Defines the delay between the coming into
operation of the delta contactor and the – Defines the oil filter change countdown
energisingof the load/unload solenoid valve; timer value.
such delay stabilises as much as possible
– When the set timer has elapsed, the
controller will warn the operator that

46 DL105AA
CompAir AirBASIC Electronic Controller 9

maintenance is needed by showing a restart automatically after a delay that is


dedicated warning message (S03) on the equivalent to blow down time delay.
display.
P18 - Alarm relay function
P14 - Separator filter maintenance
– Defines which function is to be assigned to
pre-alarm hours
the alarm remoting relay contact, in
– Defines the separator filter change accordance with the following arrangement:
countdown timer value.
P18=0
– When the set timer has elapsed, the Relay is energised in any alarm condition and
controller will warn the operator that in any pre-alarm condition.
maintenance is needed by showing a
P18=1
dedicated warning message (S04) on the
Relay is energised only in alarm conditions
display.
that will stop the compressor.
P15 - Oil maintenance pre-alarm hours
P18=2
– Defines the oil change countdown timer Relay is energised only when one of the
value. maintenance timers has elapsed.
– When the set timer has elapsed, the
controller will warn the operator that
maintenance is needed by showing a
dedicated warning message (S01) on the
display.
P16 - Overall maintenance pre-alarm hours
– Defines the general maintenance
countdown timer value.
– When the set timer has elapsed, the
controller will warn the operator that
maintenance is needed by showing a
dedicated warning message (S06) on the
display.
P17 - Automatic restart status
Warning: If the automatic restart feature is
to be used, it is strongly adviced to affix a
warning sign by the machine to alert
bystanders that the compressor may come
back into operation automatically and
without prior notice. It is also mandatory to
check that the automatic re-start of the
compressor will not pose any hazards
whatsoever.
– Enables or disables the automatic restart of
the compressor as soon as current is back
after a power failure.
P17=0 automatic restart is disabled.
When current is back after a power failure has
halted the compressor, the compressor will
NOT restart automatically and the controller
will display a dedicated alarm message (A33).
P17=1 automatic restart is enabled.
When current is back after a power failure has
halted the compressor, the compressor will

DL105AA 47
9 AirBASIC Electronic Controller CompAir

9.7 Error Management 9.7.2 Shutdown Faults

9.7.1 Advisory Alarms The shutdown faults in the controller are


designed to protect the compressor from
The advisory alarms alert the user that component failure or extreme environmental
maintenance is needed, or that certain conditions. These alarms will stop the
parameters may be approaching their compressor and/or inhibit its start-up. To reset
shutdown level. Advisory alarms can be reset an alarm message, eliminate the cause of the
while the compressor is running or stopped by concern and press RESET.
pressing the RESET button. If the error
condition still exists after resetting the See the following table for shutdown faults
advisory alarm, the advisory alarm will occur that can occur in the AirBASIC Controller
again after the compressor is powered ON
Shutdown Faults
again after it has been powered OFF.
Code Meaning
See the following tables for advisory alarms
that can occur in the controller. A01 high oil temperature
A03 motor thermal overload relay trip
Pre-Alarms
A04 phase inversion/phase loss
Code Meaning
A07 temperature probe is faulty
a03 High oil temperature pre-alarm (message
alternates with temperature display). set data loss and acquisition of default
A26
data
Alarm automatically resets when
temperature drops below the set value power failure (only applicable if automatic
A33
of -2 °C. restart is disabled)
A34 low oil temperature
Maintenance Alarms
Code Meaning
S01 Oil change
S02 Air filter replacement
S03 Oil filter replacement
S04 Separator filter replacement
S06 General maintenance

Note: It is recommended that maintenance be


performed as soon as possible after a
maintenance message appears.

48 DL105AA
CompAir AirBASIC Electronic Controller 9

9.8 Transducer Locations


9.8.1 See fig. 9.4





 

  
 
 



     
Fig. 9.4 - Wiring Diagram

9.8.2 Key to codes in fig. 9.4

Input
Pin Function Status
connector
M1 power supply connector 24 Vac
M2 digital input connector, type: 5 poles Combicon 5 mm
C3 1 Common digital inputs
l1 2 Line pressure switch Closed=loaded Open=unloaded
l2 3 Motor thermal relay Alarm if open
l3 4 Phase-sequence relay Alarm if open
l4 5 Remote Start/Stop Closed=start Open=stop
M3 alarm relay connector, type: 2 poles Combicon 5 mm
C2 1 Common relay
R 2 Auxiliary alarm relay Energised=closed De-energised=open
M4 output relay connector, type: 5 poles Combicon 5 mm
C1 1 Common relay
K1 2 Line contactor Energised=closed De-energised=open
K2 3 Star contactor Energised=closed De-energised=open
K3 4 Delta contactor Energised=closed De-energised=open
EV 5 Solenoid valve Energised=closed De-energised=open
M5 temperature probe connector, type: screw terminals welded on the I.C.
1 Temperature probe
2 Temperature probe

DL105AA 49