You are on page 1of 5

See discussions, stats, and author profiles for this publication at: https://www.researchgate.

net/publication/277106024

Selection of measuring method for waste water flow measurement

Article · January 2007

CITATIONS READS

0 170

2 authors:

Siniša Bikić Masa Bukurov


University of Novi Sad University of Novi Sad
24 PUBLICATIONS   47 CITATIONS    21 PUBLICATIONS   45 CITATIONS   

SEE PROFILE SEE PROFILE

Some of the authors of this publication are also working on these related projects:

CEEPUS CIII-RS-1012 Building Knowledge and Experience Exchange in CFD View project

Combine drying technology View project

All content following this page was uploaded by Masa Bukurov on 14 April 2016.

The user has requested enhancement of the downloaded file.


Biblid: 1450-5029 (2007) 11; 1-2; p.45-48 Prgledni rad
UDK: 628.311 Review

IZBOR METODE ZA KONTINUALNO MERENJE PROTOKA


OTPADNIH VODA
SELECTION OF MEASURING METOD FOR WASTE WATER
FLOW MEASURMENT
Mr Siniša BIKI, dr Maša BUKUROV
Fakultet tehnikih nauka, 21000 Novi Sad, Trg Dositeja Obradovia 6
REZIME
Postoje razliite metode i merila za merenje protoka otpadnih voda, pri emu se ne može govoriti o “najboljoj” mernoj metodi,
niti o najboljem “merilu”. Izbor pojedine merne metode pri projektovanju mernih sistema za kontinualno merenje protoka otpadnih
voda zavisi od konkretnog sluaja i ima veliki uticaj ne samo na tanost mernog sistema, ve i na njegovu funkcionalnost. Stoga se
izboru merne metode mora posvetiti posebna pažnja. U radu je prikazan pregled verifikovanih mernih metoda koje se naješe
koriste u sistemima za kontinualno merenje protoka otpadnih voda. S obzirom da zakonska regulativa u Republici Srbiji propisuje
nadoknadnu za koliinu i kvalitet izbaene otpadne vode u vodotoke, u radu je pored primene poseban akcent stavljen na tanost
mernih metoda. Nakon izmene zakonske regulative, tanost mernih sistema, pa samim tim i mernih metoda je osnovni zahtev potenci-
jalnih investitora.
Kljuen rei: merenje protoka otpadnih voda, merila protoka u otvorenim kanalima, merenje protoka u otvorenim kanalima.
SUMMARY
There are different measuring methods and different flow meters of waste water flow measurement and it is not possible to tell
which method or which flow meter is the best. The selection of certain measuring method for continual flow system designing is dif-
ferent for each case and influences not only accuracy of measuring system but its functionality too. Because of that selection of meas-
uring method requires special attention.In this paper are reviewed verified measuring methods which are most often used in systems
for continual waste water flow measurement. Since the legislative in Serbia issue compensation for quantity and quality of released
waste water in water currents, in this paper is emphasized not only application , but accuracy of measuring methods as well. The
most common requirement of potential investors is accuracy of measuring methods.
Key words: waste water flow measurment, flow meters in open canals, flow measurment in open canals.
Razmatranje e se ograniiti na ustaljeno, ravnomerno stru-
UVOD
janje otpadne vode pri uobiajnim temperaturama od 5 do 30 qC.
Generalno, sledei faktori utiu na izbor metode za merenje Takoe, posmatrae se stalne merne stanice, kod kojih se konti-
protoka u otvorenim tokovima: nualno meri protok otpadne vode.
- Tip mernog sistema (stanice): stalna, privremena, kratkorona; MATERIJAL
- Geometrijski uslovi: razlika u nivoima vode, dimenzije i oblik
korita otvorenog toka, mogunost pristupa mernom objektu, na- Pregled mernih objekata
gib dna itd; Merni prelivi sa oštrim ivicama
- Hidrauliki uslovi: opseg protoka koji se meri (maksimalni i
minimalni protok), vrednost osnovnog protoka koji se meri
(podzemne vode i voda ispuštena iz procesa), režim strujanja
(burni ili mirni), kvalitet otpadne vode (otpadna voda sa suspen-
dovanim ili vuenim nanosom), uslovi strujanja u prilaznom i
izlaznom kanalu;
- Tanost merenja koja se želi postii;
- Raspoloživost prikljuka za snabdevanje elektrinom energi-
jom;
Sl. 1. Tompsonov oštroivini preliv [4]
- Raspoloživost pouzdane opreme na lokalnom tržištu;
1 – rešetka, 2 – tankozidni oštroivini preliv, 3 – ovazdušavanje,
- Iskustvo i predrasude donosioca odluke; 4 – merilo nivoa
- Ekonomski faktori: cena izgradnje i opreme, rada, održavanja i Fig 1. Thompson's weir, 1- bars, 2 – weir, 3 – aeration, 4 – level
obrade podataka i meter
- Ostali faktori [3].
Merni objekti koji se ugrauju u merne sisteme za kontinual- Za merenje protoka otpadnih voda mogu se koristiti pregrade
no merenje protoka otpadne vode mogu da se sa stanovišta zah- sa prelivnom ivicom (sl.1). Fluid ispred pregrade mora biti pot-
tevane tanosti i kvaliteta otpadne vode svrstati u tri grupe: puno smiren, što se postiže odreenom dužinom pravouglog ka-
1.Merni prelivi sa oštrim ivicama; nala glatkih ivica i ugraenim rešetkama za smirivanje toka is-
2.Merni pragovi i merna suženja i pred preliva. Na pregradnoj ivici stvara se mlaz koji mora biti
3.Brane, ustave i kaskade. potpuno ventilisan (ubacivanje vazduha ispod mlaza preliva).
Za svaku od predhodno navedenih grupa mernih objekata, Oštroivini preliv obezbeuje pouzdanu liniju odvajanja vode,
prikazae se pregled mernih objekata i dae se osnovne smernice dozvoljavajui da vazduh aeriše donju stranu mlaza [4].
za izbor merne metode, po predhodno navedenim kriterijumima. Prelivi sa oštrom ivicom mogu prema geometriji biti: trouga-
oni Tomsonov (sl.1); pravougaoni Bazenov, trapezni ipoletijev.

PTEP 11(2007) 1-2 45


Prema postojanju suženja mogu biti: bez bonog suženja i sa bo- vima kanala. Prelivni mlaz mora biti dovoljno provetren da osi-
nim suženjem. gura atmosferski pritisak na donjoj površini mlaza.
Kod neogranienog prelivnog mlaza zidovi kanala završava-
Merni pragovi i merna suženja ju se sa ivicom kaskade, te se prelivni mlaz širi i dovoljno je
Merni pragovi mogu biti: provetren da osigura atmosferski pritisak na donjoj površini pre-
- Prelivi sa širokim pravougaonim pragom (oštra uzvodna ivi- livnog mlaza [6], [9].
ca);
- Prelivi sa širokim pravougaonim pragom (zaobljena uzvodna
ivica);
- Prelivi sa pravougaonim pragom i krunom u obliku latininog
slova V;
- Prelivi sa trougaonim pragom i
- Prelivi sa trougaonim pragom i krunom u obliku latininog
slova V [10].
Sl. 3. Izgled i funkcija hidrodinamiki oblikovanog preliva [1]
Na slici (sl.2), prikazani su osnova, preseci i linija nivoa stru-
Fig 3. Hydrodinamic shaped weirs [4]
janju otpadne vode kroz merni objekat sa suženjem, gde su: bk -
širina dna u kritinom preseku (m); b - širina dna u preseku is-
pred i iza suženja (m); L1 - rastojanje od mernog mesta do poet-
DISKUSIJA
ka mernog suženja (m); L2 - dužina ulaznog dela suženja (m); L3 Izbor mernog objekta za kontinualno
- dužina grla suženja (m); L4- dužina izlaznog dela mernog suže- merenje protoka otpadnih voda
nja (m); EM - linija ukupne energije bez postojanja gubitaka (m).
Kod kontinualnog merenja protoka otpadnih voda izbor mer-
ne metode vezuje se za izbor mernog objekta. U narednom
tekstu dati su opšti kriterijumima za izbor mernog objekta.
Raspoloživa razlika u nivoima vode: Najvea razlika iz-
meu nivoa vode uzvodno i nizvodno od mernog objekta, koja
obezbeuje slobodno, potpuno aerisano strujanje u uslovima
maksimalnog protoka vode, zahteva se kod tankozidnih oštroivi-
nih i kaskadnih preliva.
Merni prelivi sa oštrim pragom mogu se koristiti sa manjim
razlikama u nivoima otpadne vode ispred i iza objekta u odnosu
na oštroivine i kaskadne prelive, dok se merni prelivi sa trouga-
onim žljebom i merna suženja mogu koristiti i pri još manjim
razlikama gornje i donje vode.
Tanost merenja: Tanost merenja odreenog mernog sis-
tema za kontinualno merenje protoka otpadnih voda zavisi od
procene pojedinih komponenata nesigurnosti, dok su procene
približnih opsega nesigurnosti (u granicama verovatnoe 95%)
za merne prelive i objekte sledei:
- Pravougaoni prelivi sa oštrim ivicama od 1 do 4 %;
- Trougaoni prag sa žlebom (ugao žleba izmeu S/9 i 5S/9 rad)
1 do 2 %;
Sl. 2. Osnova, preseci i linija nivoa strujanju otpadne vode kroz - Prelivi sa širokim pravougaonim pragom 3 do 5 %;
merni objekat sa suženjem - Merna suženja od 2 do 5 % i
Fig 2. Basis, crossections and level line of waste water flow - Kaskadni prelivi od 5 do 10 %.
through flume [2] Detaljni prikaz tanosti mernih objekata dat je tabelarno
(tab.2).
Brane, ustave i kaskade Gornje granice merne nesigurnosti postižu se ugradnjom sta-
Merni prelivi praktinog profila mogu biti prizmatini i hid- ndardnih mernih objekata u skladu sa preporukama. Donje gra-
rodinamiki oblikovani. nice merne nesigurnosti postižu se ugradnjom standardnih mer-
Kruna hidrodinamiki oblikovanog preliva prilagoava se nih objekata u skladu sa preporukama u laboratorijskim uslovi-
donjoj konturi prelivnog mlaza (sl. 3), tako da pritisak na leima ma. Ugradnja nestandardnih mernih objekata, kao i ugradnja sta-
preliva bude nešto vei od atmosferskog, tj. sada je pb > pa ndardnih mernih objekata koja nije u skladu sa preporukama
može rezultirati velikim greškama merenja.
[5].
Veliina i oblik korita otvorenog toka: Pravougaoni merni
Kada se dno ravnog kanala naglo prekine nastaje slobodni
prelivi sa pragom i merni prelivi sa žlebom (i pravougaoni i tro-
kaskadni preliv. Na mestu prekida kanala strujanje je krivolinij-
ugaonim) velikih dimenzija u odnosu na veliinu kanala treba da
sko, pa stoga dubina na njegovom kraju nije jednaka kritinoj
budu postavljeni na ravno dno sa vertikalnim zidovima ili u pre-
dubini kako se to rauna kod ostalih mernih objekata na osnovu
livne komore pravougaonog preseka, koji se protežu uzvodno na
pretpostavke o paralelnom strujanju. Merenjem dubine na ivici
rastojanju ne manjem od 10 širina prelivnog mlaza pri maksi-
kaskade h1 može se odrediti protok vode Q.
malnom protoku.
Razlikuju se kaskade sa ogranienim i sa neogranienim pre-
Merni prelivi sa širokom krunom najbolje se koriste u pravo-
livnim mlazom.
ugaonim koritima tokova, ali se mogu koristiti i u nepravougao-
Kod ogranienog prelivnog mlaza zidovi kanala nastavljaju nim koritima sa dobrom tanošu ako se gladak, pravougaoni
se na dužini l t 6h1 od kaskade, te je strujanje ogranieno zido- prilazni kanala proteže uzvodno od preliva na udaljenosti ne ma-

46 PTEP 11(2007) 1-2


njoj od dvostruke merne dubine pri maksimalnom protoku.Za Tabela 1. Simboli koji se radi preglednosti podataka koriste
oštroivine merne prelive malih dimenzija u odnosu na veliinu u tabeli 2. [7]
kanala, naroito ako je prilazna brzina zanemarljiva, veliina i Table 1 Symbols used in Table 2 [7]
oblik korita imaju veliki znaaj.
Simbol Definicija
Merna suženja mogu se koristiti u koritima bilo kakvog obli- Symbol Definition
ka, pod uslovom da je strujanje u prilaznom kanalu ustaljeno i Režim strujanja bi trebalo da bude miran
ravnomerno. Za merna suženja svih tipova, veliina i oblik niz- a
Flow regime should be still
vodnog kanala imaju znaaja ukoliko istim može da se utie na Ne bi trebalo da bude poprenih struja
potopljenost mernog suženja. b
Lateral streams shouldn't exist
Za merne prelive, veliina i oblik nizvodnog kanala su od Deonica bi trebalo da je približno prava i simetrinog pop-
znaaja ako se mora omoguiti slobodno i aerisano strujanje u renog preseka na dužini od oko 10 širina korita uzvodno
svim uslovima. od mernog objekta
c
Detaljniji prikaz preporuka za veliinu i oblik korita, kao i Flow section should be almost strait and symmetrical
mernih nesigurnosti dat je tabelarno (tab.2) gde su prikazane crossection at about 10 length of canal width upstream from
preporuke ISO standarda. measuring object
Uslovi strujanja u prilaznom kanalu: Za prelive svih tipo- Korito bi trebalo da ima vertikalne strane i ravno dno, uz-
va strujanje u prilaznom kanalu treba da bude mirno, ustaljeno, i vodno na dužini ne manjoj od 10-struke širine prelivnog
ravnomerno. U idealnom sluaju, naroito za relativno velike d mlaza pri maksimalnoj dubini vode
prilazne brzine, raspodela brzine treba da se približava raspodeli Canal should have vertical sides and flat bottom, upstream
brzine pri strujanju u pravim, glatkim kanalima. U kratkim kana- not less than 10 width of weir during maximal water level
Korito bi trebalo da je pravougaono uzvodno na dužini od
lima i prelivnim komorama mogu se koristiti umirivai i usmeri-
najmanje dvostruke dubine vode
vai toka za ostvarivanje normalne raspodele brzine. e
Canal should be rectangular at length of at least two water
Mirno strujanje obezbeuje se ako je Frudov broj Fr<1, tj. depths upstream
kada je srednja brzina strujanja u prilaznom kanalu: Raspodela brzine treba da je približno jednolika
f
v< gA B , Velocity distribution should be uniform
Korito bi trebalo da je približno u obliku latininog slova U
gde su: v -srednja brzina u prilaznom kanalu (m/s); g - g
Canal should be shaped as letter U
gravitaciono ubrzanje (m2/s); A -površina poprenog preseka ka-
Metoda koja je pogodna za eša merenja protoka
nala (m2); B - širina vodenog ogledala kanala (m). A
Method suitable for more often measuring
Kvalitet otpadne vode: Kod otpadnih voda sa suspendova- Krupne estice nanosa nisu dozvoljene
nim nanosom treba izbegavati upotrebu oštroivinih preliva, jer B
Coarse particles of deposits are not alowed
se ivice krune mogu oštetiti ili pohabati suspendovanim materi- Brza metoda (manje od 1 h)
jalima, dok se kod otpadnih voda sa vuenim nanosom oštroivi- C
Quick method (less than 1 h)
ni merni prelivi iskljuuju iz razmatranja. Srednja širina (izmeu 5 m i 50 m) ili srednja brzina (izme-
Kod pojave plivajuih predmeta u otpadnoj vodi, merni pre- u 1 m/s i 3 m/s) ili srednja dubina (izmeu 1 m i 5 m)
livi sa pragom, merni prelivi trougaonog preseka, merna suženja D
Meadium width (between 5 and 50 m) or meadium velocity
i kaskade propuštaju plivajue predmete efikasnije od mernih (between 1 and 3 m/s)
preliva sa oštrim ivicama. Upotreba preliva sa trougaonim žle- Mala širina (manje od 5 m) ili mala dubina (manje od 1 m)
bom treba izbegavati, osim ako uzvodno nisu postavljeni hvatai ili mala brzina (manje od 1 m/s)
E
plivajuih predmeta. Small width (less than 5 m) or small depth (less than 1 m)
Veliina protoka koji se meri: Sa stanovišta funkcionalnos- or small velocity (less than 1 m/s)
ti i tanosti, merni prelivi sa oštrim ivicama su pogodni za mere-
ZAKLJUAK
nje relativno malih protoka otpadne vode, dok su merni prelivi
sa pragom, merni prelivi trougaonog preseka i merna suženja Sveobuhvatni pregled mernih objekata koji se potencijalno
pogodni za velike protoke vode. mogu ugraditi u merne sisteme za kontinualno merenje protoka
Opseg protoka vode koji se meri: Za postizanje više tano- otpadnih voda, ukazuje na ozbiljnost izbora adekvatnog mernog
sti u širokom opsegu malih protoka otpadne vode treba koristiti objekta, tj. metode.
merni preliv sa trougaonim žlebom, pre nego sa pravougaonim Analiziranjem mernih objekata nekim od predhodno defini-
žlebom ili prvougaoni preliv bez kontrakcije. Za široki opseg sanih kriterijuma za izbor merne metode, uoava se svrsishod-
velikih protoka otpadne vode treba koristiti merna suženja sa nost razvrstavanja mernih objekata u navedene tri grupe.
trapeznim ili U – poprenim presekom, pre nego merni preliv sa Prva grupa mernih objekata u koju spadaju oštroivini merni
širokom pragom, kaskadni preliv, merno suženje pravougaonog prelivi može se koristiti za kontinualno merenje protoka otpadne
poprenog preseka ili merni preliv trougaonog preseka. vode, gde se zahteva visoka tanost (za naplatu ispuštene kolii-
Gradnja: Oštroivini merni prelivi izrauju se u radionica- ne otpadne vode) i gde otpadna voda ne sadrži suspendovani ili
ma. Merna suženja, merni prelivi sa pragom, merni prelivi trou- vueni nanos, kao ni grube predmete koji bi oštetili ivicu preliva.
gaonog preseka i kaskadni prelivi mogu se zadovoljavajue gra- Druga grupa mernih objekata gde spadaju merni pragovi i
diti na terenu. U svim sluajevima, velika pažnja mora se posve- merna suženja, mogu se koristiti za kontinualno merenje protoka
titi ugradnji mernih objekata prema standardnim preporukama. otpadne vode, gde se zahteva nešto niža tanost u odnosu na pr-
vu grupu (za naplatu ispuštene koliine otpadne vode), i gde ot-
Merni prelivi sa pragom, prelivi trougaonog preseka, kaska-
padna voda može da sadrži suspendovani ili vueni nanos, kao i
dni prelivi i merna suženja mnogo su otpornija i lakše se održa-
grube predmete. Na primer merenje protoka otpadnih voda koje
vaju pri velikim protocima.
se sistemom drenažnih cevi i kanala ispuštaju u vodotok.
Iso standardi za pojedine merne objekte Trea grupa mernih objekata gde spadaju merne brane, kas-
U tabeli (tab.1) dati su simboli koji se koriste u tabeli (tab.2) kade i ustave, mogu se koristiti za bilansiranje otpadne vode.
gde su date preporuke i oekivane minimalne tanosti meuna- Npr. za merenje protoka u kanalima u koje se na više mesta is-
rodnog ISO standarda za pojedine merne objekte. pušta otpadna iz raznih procesa.

PTEP 11(2007) 1-2 47


Tabela 2. Preporuke i oekivane minimalne tanosti meunarodnog ISO standarda za pojedine merne objekte
Table 2. Recommendation and expected minimal accuraces of international ISO standard for certain measuring objects
Metoda Kriterijum / Criterion Tanost / Accuracy
Hidrauliki Faktor
Odgovarajui Minimalna
Br. Opis Širina Dubina Brzina uslovi vreme Komentar
meunarodni standard Minimal
No. Description Width Depth Velocity Hydraulic Factor Notes
International standard (%)
conditions time
Oštroivini trougaoni prelivi
1. ISO 1438-1 E E E a, b, c, f C, A r1 B
Weirs
Oštroivini pravougaoni prelivi
2. (bez bone kontrakcije) ISO 1438-1 D, E E E a, b, c, d, f C, A r3 B
Rectangular Weir (without contraction)
Oštroivini pravougaoni prelivi
3. (sa bonom kontrakcijom) ISO 1438-1 D, E E E a, b, c, d, f C, A r3 B
Rectangular Weir (with contraction)
Prelivi sa pravougaonim širokim pragom
(oštra uzvodna ivica)
4. ISO 3846 D, E E D, E a, b, c, d, f C, A r5 B
Weirs with rectangular threshold (sharp
upstream edge)
Prelivi sa zaobljenim širokim pragom
(zaobljena uzvodna ivica)
5. ISO 4374 D, E E D, E a, b, c, e, f C, A r5 B
Weirs with threshold (shaped upstream
edge)
Prelivi sa trougaonim pragom
6. ISO 4360 D, E D, E D, E a, b, c, e, f C, A r5 B
Weirs with triangular threshold
Prelivi sa pragom praktinog profila
7. ISO 9827 D, E D, E D, E a, b, c, f C, A r5 B
Weirs with practical shaped threshold
Prelivi sa trougaonim pragom i krunom u
obliku širokog latininog slova V
8. ISO 4377 D, E D, E D, E a, b, c, f C, A r5 B
Weirs with triangular threshold and V
notch
Prelivi sa širokim pravougaonim pragom i
krunom u obliku širokog lat. slova V
9. ISO 8333 D, E D, E D, E a, b, g C, A r5 B
Weirs with rectangular threshold and V
notch
Prelivi sa prizmatinim pragom
10. ISO 4362 D, E D, E D, E a, b, c C, A r5 B
Weirs with prismatical threshold
Merni kanali-pravougaono suženje
11. ISO 4359 D, E D, E D, E a, b C, A r5 B
Rectangular Flumes
Merni kanali-prizmatino suženje
12. ISO 4359 D, E D, E D, E a, b C, A r5 B
Trapezoidal Flumes
Merni kanali-suženje u obliku slova U
13. ISO 4359 D, E D, E D, E a, b, g C, A r5 B
U Shape (Palmer - Bowles) Flumes
Merni kanali – “Parshall” i “Saniri”
14. ISO 9826 D, E D, E D, E a, b, c, f C, A r10 B
Parshall’s Flumes
Kaskade, pravoug.i nepravougaoni kanali
(metoda merenja dubine na kraju toka)
15. ISO 3847 i 4371 D, E D, E D, E a, b, c, f C, A r10 B
Cascades (depth measuring at the end of
stream)

[7] Jugoslovenski standard za merenje protoka vode u otvore-


LITERATURA nim tokovima, prelivima i mernim objektima, Metoda pro-
[1] P, Ackers, J, A, Perkins and A, J, M, Harrison, “Weirs and rauna protoka vode odreivanjem dubine na kraju pravou-
flumes for flow measurement”, John Wiley and Sons, 1978 gaonog kanala sa slobodnom kaskadom, JUS U.C5.092,
[2] Prodanovi, D, Merenja u hidrotehnici, skripta, Graevinski 1994
fakultet, Beograd, 2006 [8] Jugoslovenski standard za merenje protoka vode u otvore-
[3] Maksimovi, , Merenja u hidrotehnici, Graevinski fakul- nim tokovima, prelivima i mernim objektima, Pravougaoni
tet, Beograd, 1993 preliv sa širokom krunom, JUS U.C5.090, 1994
[4] Hajdin, G, Mehanika fluida, knjiga druga, Graevinski fa- [9] Biki, S, Bukurov, Maša, Proper Selection Of Ultrasound
kultet, Beograd, 2002 Level Meter For The Flow Rate Measurment In Open Ca-
[5] Graevinski prirunik, peta knjiga, Graevinska knjiga, Be- nals, The 8th International Symposium Young People Mul-
ograd, 1980 tidisciplinary Research, Resita, Romania, 2006
[6] Biki, S, Bukurov, Maša, Importance Of Open Channel Ca- [10] Miller R.W, Flow Measurement Engineering Handbook,
libration In Flow Rate Measuring, Scintific conference 2, McGraw-Hill, New York, 1983
2006, Rousse. (proceedings, volume 45, book 1, ISSN 1311-
3321). Primljeno: 12.3.2007. Prihvaeno: 19.3.2007

48 PTEP 11(2007) 1-2

View publication stats