You are on page 1of 1

PROJECT : Zapata de Futuro Hospital de Nueco Chimbote PAGE :

CLIENT : Ministerio de Salud -Peru DESIGN BY :


JOB NO. : DATE : 11/17/2020 REVIEW BY :
Concrete Diaphragm in-plane Shear Design Based on ACI 318-19

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH (ACI 318 19.2.1.1) fc' = 4 ksi, (28 MPa)
LIGHTWEIGHT CONCRETE ? (ACI 318 19.2.4) Yes (Lightweight Concrete)

REBAR YIELD STRESS fy = 60 ksi, (414 MPa)


THE DIAPHRAGM DESIGN IS ADEQUATE.
THICKNESS OF DIAPHRAGM t = 6 in, (152 mm)

DIAPHRAGM REINFORCING 2 # 5 @ 12 in. (305 mm) o.c.


(at Middle, Each Way)
FACTORED IN-PLANE SHEAR LOAD Vu = 25 kips/ft, (364.8 kN/m), (37.2 Tn/m)

ANALYSIS

CHECK MINIMUM REINFORCEMENT RATIOS (ACI 318 18.12.7 & 24.4)


(r t )provd. 0.0086 > (r t )min. = 0.0018 [Satisfactory]
=
CHECK SHEAR CAPACITY (ACI 318 12.5.3)
fVn =MIN [ f Acv (2 l (fc')0.5 + rt fy), f 8 Acv (fc')0.5 ] = 27.32 kips/ft > Vu [Satisfactory]
where f = 0.75 (ACI 318 21.2)
Acv = 72 in2
l = 0.75 (ACI 318 19.2.4)

You might also like