You are on page 1of 12

PROJECT :

CLIENT :
JOB NO. : DATE :
Bridge Design for Prestressed Concrete Box Section Based on AASHTO 17th Edition & ACI 318

INPUT DATA & DESIGN SUMMARY


BRIDGE SPAN L= 120 ft
SECTION DIMENSIONS SECTION PROPERTIES
T= 280 in, within [B , 300"] , (7112 mm) A= 15529.0 in2
B= 240 in, within [200", 280"] , (6096 mm) yt = 41.82 in
C= 110 in, within [80",180"] , (2794 mm) yb = 54.18 in
D= 96 in, within [L/15 , L/25] , (2438 mm) I= 19766329 in4
Tt = 12 in, within [8",18"] & >T/30 , (305 mm) St = 472656 in3
Tb = 24 in, within [8", 24"] & >B/30 , (610 mm) Sb = 364825 in3
W= 24 in, within [8", 24"] & >D/15 , (610 mm)
Tc = 24 in, within [14", 24"] & >C/12 , (610 mm)
Te = 6 in, (152 mm)
CONCRETE STRENGTH f 'c = 6 ksi, (41 MPa)
REBAR STRENGTH fy* = f y = 60 ksi, (414 MPa)
TENDON TENSILE STRENGTH fsu* = fpu = 270 ksi, (1862 MPa)
TENDON YIELD STRENGTH fpy = 243 ksi, (1675 MPa)
DISTANCE TO CENTROID OF COMPRESSION d' = 6 in, (152 mm)
DIST. TO CENTROID OF BOT. PRESTRESSED dp,b = 84 in, (2134 mm)
DIST. TO CENTROID OF WEB. PRESTRESSED dp,w = 76 in, (1930 mm)
DISTANCE TO CENTROID OF TENSION d= 80 in, (2032 mm)
TOP COMPRESSION REINF. 2 # 8 @ 12 in o.c., (305 mm)
BOTTOM TENSION REINF. 2 # 8 @ 12 in o.c., (305 mm)
WEB HORIZONTAL REINF. 2 # 8 @ 12 in o.c., (305 mm)
SHEAR STIRRUP REINF. 2 legs, # 10 @ 8 in o.c., (203 mm)
BOTTOM PRESTRESSING TENDONS
16 x 36 strands (each 0.5 in diameter & 0.153 in2 area )
EACH WEB PRESTRESSING TENDONS (13 mm) ( 99 mm2)
4 x 36 strands (each 0.5 in diameter & 0.153 in2 area )
TOTAL TENDON FORCE IMMEDIATELY AFTER PRESTRESS TRANSFER 0.8 fpy, (ACI 318-14
TOTAL TENDON FORCE AT SERVICE LOAD AFTER ALLOWANCE LOSSES 0.64 fpy, (ACI 318-14
MOMENT DUE TO SELF-WEIGHT MG = 29116.963 ft-kips, (39477 kN-m) VERTICAL SHEAR FORCE
MOMENT DUE TO DEAD LOAD MD = 37500 ft-kips, (50843 kN-m) TORSIONAL MOMENT
MOMENT DUE TO LIVE LOAD ML = 52500 ft-kips, (71180 kN-m) LATERAL BENDING MOME
SECTION LOCATION ( 0, 1 or 2 ) 0 at midspan (Seismic/Wind Hori
PRESTRESSING METHOD ( 0, 1 or 2 ) 2 post-tensioned & bonded
EXPOSURE ( 0 OR 1 ) 0 mild exposure THE DESIGN IS

CHECK TRANSFER LOAD CONDITION (AASHTO 9.15.1 & 9.15.2.1)


ENTIRE SECTION PRESTRESSED ECCENTRICITY
e= 38.18 in
MIN. TOP FIBER STRESS
- Fti = -0.581 ksi
MAX. BOT. FIBER STRESS
Fbi = 3.300 ksi
MAX. ALLOWABLE STRESS
Fsi = 189.000 ksi

fsi = 194.400 ksi


> Fsi
[Unsatisfactory]
0.318 ksi > - Fti
[Satisfactory]
(As')reqd =
3.387 ksi > Fbi (ACI 318-14 24.4 &
[Unsatisfactory]

CHECK SERVICEABILITY LOAD CONDITION (AASHTO 9.15.1 & 9.15.2.2)


CONCRETE DECK THICKNESS
t= 4 in
(0 for non-composite)
COMPOSITE SECTION PROPERTIES
b= 500 in
Ac = 17529.0 in2
yct = 40.82 in
ycb = 59.18 in
Ic = 23171159 in4
Sct = 567642 in3
Scb = 391537 in3
MIN. TOP FIBER STRESS MAX. BOT. FIBER STRESS
Fte = 0.6fc' = 3.600 ksi, for total loads -Fbe = -(0, 3, or 6)(
Fte, G+D = 0.4fc' = 2.400 ksi, for sustained loads only MAX. ALLOWABLE STRES
Fte, 0.5(G+D)+L = 0.4fc' = 2.400 ksi, for live + 50% sustained loads Fse = 0.8fy =
fse = 155.520 ksi < Fse
[Satisfactory]

2.181 ksi < Fte [Satisfactory]

1.071 ksi < Fte, G+D [Satisfactory]

1.646 kis < Fte, 0.5(G+D)+L


[Satisfactory]

-0.175 ksi > -Fbe [Satisfactory]

CHECK ULTIMATE LOAD CONDITION (AASHTO 9.15.1 & 9.17 ACI 318-14 20.3)
FACTORED ULTIMATE MOMENT
Mu,x = g ( bD MD + bL ML ) = 1.3 [ 1.0 ( MG + MD) + 1.67 ML]
(AASHTO Eq. 3-10)
= 200579.551 ft-k
Mu,y = 41320.410 ft-k

Mu = (Mu,x2 + Mu,y2)0.5
= 204791.437 ft-k

q= 11.6 deg

COMPRESSION ZONE FACTOR


b1 = 0.75 , (ACI 318-14 22.2.2)
TENDON TYPE FACTOR
gp = 0.280 , (ACI 318-14 20.3.2.3.1)
RATIO OF TENSION REINF. r = 0.001 , (ACI 318-14 Chapter 2)
RATIO OF COMPR. REINF. r' = 0.002 , (ACI 318-14 Chapter 2)
RATIO OF PRESTR. REINF. rp = 0.006 , (ACI 318-14 Chapter 2)
INDEX OF TENSION REINF. w = 0.013 , (ACI 318-14 20.3.2.3.1)
INDEX OF COMPR. REINF. w' = 0.016 , (ACI 318-14 20.3.2.3.1)
INDEX OF PRESTR. REINF. w p= 0.237 , (ACI 318-14 20.3.2.3.1)
STRESS IN BONDED TENDONS :

243.940 ksi

STRESS IN UNBOUNDED TENDONS :

Not applicable

Not applicable
145854 ft-k <
(AASHTO 9.18.2 & ACI 318-11 18.8.2, bu

CHECK SHEAR CAPACITY (AASHTO 9.20, ACI 318-14 9 & 22)

84.00 in

3200.40 kips

24.00 in
4.434 in2

CHECK TORSIONAL CAPACITY (AASHTO 9.21, ACI 318-14 22.7)

Acp = 26880 in2


Pcp = 752 in Tu >
fpc = 0.765 ksi
Aoh = 25293 in2 Thus, Torsiona
Ph = 735 in

0.020 in2/in

0.595 in2/in < 0.635 in2/in

[Satisfactory]

LICENSE NUMBER: Package License Including N

www.Engineering-International.com
130
PAGE :
DESIGN BY : dr youssf hamida
REVIEW BY :
Edition & ACI 318-14

<== Tips: 1. Input T = B for rectangular box section.


2. Input actual dp,w values to check midspan section a

fpy, (ACI 318-14 20.3) Pi = 25698.1 kips


fpy, (ACI 318-14 20.3) Pe = 20558.5 kips
ICAL SHEAR FORCE Vu = 6886.735 kips, (30632.2 kN)
IONAL MOMENT Tu = 35868.412 ft-kips, (48631 kN-m)
RAL BENDING MOMENT Mu,y = 41320.41 ft-kips, (56023 kN-m)
(Seismic/Wind Horizontal Bending Load)

THE DESIGN IS INADEQUATE, SEE ANALYSIS


0.000 in2 < (As')provd
(ACI 318-14 24.4 & 24.5) [Satisfactory]
(Cont'd)
BOT. FIBER STRESS
-Fbe = -(0, 3, or 6)(fc')0.5 = -0.465 ksi
ALLOWABLE STRESS
194.400 ksi, after all losses

es,max = 0.0021 , (ACI 318-14 7.3.3 or R21.2.2)


c= 98.2 in, by pure math method
Fc = 32282.5 kips
dc = 47.3 in
f Mn = 2603343 ft-k
> Mu
[Satisfactory]
f Mn [Satisfactory]
ACI 318-11 18.8.2, but ACI 318-14 waived)

77.46 psi

5441.73 kips

1.867 in2
(Cont'd)

[Satisfactory], Case 3 applicable

5278.243 ft-kips

Thus, Torsional Reinf. Reqd.

87.77 in2

cense Including New Software Based on ASCE 41-17, ASCE 7-16, AISC 360/341/358-16
heck midspan section and end sections.