Check Figures
Total Building Supply Air (based on a 20° TD): 209 CFM
Total Building Vent. Air (28.76% of Supply): 60 CFM
Total Conditioned Air Space: 72 Sq.ft
Supply Air Per Unit Area: 2.9082 CFM/Sq.ft
Area Per Cooling Capacity: 94.5 Sq.ft/Ton
Cooling Capacity Per Area: 0.0106 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 0.76 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 783 CFM
Total Building Vent. Air (1.92% of Supply): 15 CFM
Total Conditioned Air Space: 183 Sq.ft
Supply Air Per Unit Area: 4.2794 CFM/Sq.ft
Area Per Cooling Capacity: 114.2 Sq.ft/Ton
Cooling Capacity Per Area: 0.0088 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 1.60 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 259 CFM
Total Building Vent. Air (23.18% of Supply): 60 CFM
Total Conditioned Air Space: 156 Sq.ft
Supply Air Per Unit Area: 1.6616 CFM/Sq.ft
Area Per Cooling Capacity: 175.0 Sq.ft/Ton
Cooling Capacity Per Area: 0.0057 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 0.89 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 259 CFM
Total Building Vent. Air (23.14% of Supply): 60 CFM
Total Conditioned Air Space: 156 Sq.ft
Supply Air Per Unit Area: 1.6642 CFM/Sq.ft
Area Per Cooling Capacity: 174.9 Sq.ft/Ton
Cooling Capacity Per Area: 0.0057 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 0.89 Tons
Check Figures
Total Building Supply Air (based on a 19° TD): 4,518 CFM
Total Building Vent. Air (1.11% of Supply): 50 CFM
Total Conditioned Air Space: 138 Sq.ft
Supply Air Per Unit Area: 32.7683 CFM/Sq.ft
Area Per Cooling Capacity: 16.8 Sq.ft/Ton
Cooling Capacity Per Area: 0.0596 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 8.22 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 792 CFM
Total Building Vent. Air (22.72% of Supply): 180 CFM
Total Conditioned Air Space: 13 Sq.ft
Supply Air Per Unit Area: 59.4097 CFM/Sq.ft
Area Per Cooling Capacity: 5.1 Sq.ft/Ton
Cooling Capacity Per Area: 0.1959 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 2.61 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 346 CFM
Total Building Vent. Air (17.33% of Supply): 60 CFM
Total Conditioned Air Space: 87 Sq.ft
Supply Air Per Unit Area: 3.9840 CFM/Sq.ft
Area Per Cooling Capacity: 85.2 Sq.ft/Ton
Cooling Capacity Per Area: 0.0117 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 1.02 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 685 CFM
Total Building Vent. Air (72.94% of Supply): 500 CFM
Total Conditioned Air Space: 45 Sq.ft
Supply Air Per Unit Area: 15.1395 CFM/Sq.ft
Area Per Cooling Capacity: 9.4 Sq.ft/Ton
Cooling Capacity Per Area: 0.1061 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 4.80 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 500 CFM
Total Building Vent. Air (100.07% of Supply): 500 CFM
Total Conditioned Air Space: 24 Sq.ft
Supply Air Per Unit Area: 20.7594 CFM/Sq.ft
Area Per Cooling Capacity: 5.8 Sq.ft/Ton
Cooling Capacity Per Area: 0.1738 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 4.18 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 1,283 CFM
Total Building Vent. Air (49.88% of Supply): 640 CFM
Total Conditioned Air Space: 183 Sq.ft
Supply Air Per Unit Area: 7.0146 CFM/Sq.ft
Area Per Cooling Capacity: 21.8 Sq.ft/Ton
Cooling Capacity Per Area: 0.0458 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 8.38 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 271 CFM
Total Building Vent. Air (3.69% of Supply): 10 CFM
Total Conditioned Air Space: 113 Sq.ft
Supply Air Per Unit Area: 2.4041 CFM/Sq.ft
Area Per Cooling Capacity: 192.5 Sq.ft/Ton
Cooling Capacity Per Area: 0.0052 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 0.59 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 189 CFM
Total Building Vent. Air (10.57% of Supply): 20 CFM
Total Conditioned Air Space: 41 Sq.ft
Supply Air Per Unit Area: 4.5761 CFM/Sq.ft
Area Per Cooling Capacity: 83.3 Sq.ft/Ton
Cooling Capacity Per Area: 0.0120 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 0.50 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 494 CFM
Total Building Vent. Air (4.05% of Supply): 20 CFM
Total Conditioned Air Space: 84 Sq.ft
Supply Air Per Unit Area: 5.8780 CFM/Sq.ft
Area Per Cooling Capacity: 78.1 Sq.ft/Ton
Cooling Capacity Per Area: 0.0128 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 1.08 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 674 CFM
Total Building Vent. Air (2.97% of Supply): 20 CFM
Total Conditioned Air Space: 84 Sq.ft
Supply Air Per Unit Area: 8.0105 CFM/Sq.ft
Area Per Cooling Capacity: 59.8 Sq.ft/Ton
Cooling Capacity Per Area: 0.0167 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 1.41 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 1,370 CFM
Total Building Vent. Air (10.22% of Supply): 140 CFM
Total Conditioned Air Space: 64 Sq.ft
Supply Air Per Unit Area: 21.3991 CFM/Sq.ft
Area Per Cooling Capacity: 15.6 Sq.ft/Ton
Cooling Capacity Per Area: 0.0642 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 4.11 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 259 CFM
Total Building Vent. Air (11.56% of Supply): 30 CFM
Total Conditioned Air Space: 156 Sq.ft
Supply Air Per Unit Area: 1.6634 CFM/Sq.ft
Area Per Cooling Capacity: 223.5 Sq.ft/Ton
Cooling Capacity Per Area: 0.0045 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 0.70 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 784 CFM
Total Building Vent. Air (15.30% of Supply): 120 CFM
Total Conditioned Air Space: 111 Sq.ft
Supply Air Per Unit Area: 7.0717 CFM/Sq.ft
Area Per Cooling Capacity: 49.1 Sq.ft/Ton
Cooling Capacity Per Area: 0.0204 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 2.26 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 811 CFM
Total Building Vent. Air (9.25% of Supply): 75 CFM
Total Conditioned Air Space: 77 Sq.ft
Supply Air Per Unit Area: 10.5464 CFM/Sq.ft
Area Per Cooling Capacity: 38.1 Sq.ft/Ton
Cooling Capacity Per Area: 0.0262 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 2.02 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 259 CFM
Total Building Vent. Air (23.15% of Supply): 60 CFM
Total Conditioned Air Space: 156 Sq.ft
Supply Air Per Unit Area: 1.6636 CFM/Sq.ft
Area Per Cooling Capacity: 174.9 Sq.ft/Ton
Cooling Capacity Per Area: 0.0057 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 0.89 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 295 CFM
Total Building Vent. Air (10.18% of Supply): 30 CFM
Total Conditioned Air Space: 156 Sq.ft
Supply Air Per Unit Area: 1.8869 CFM/Sq.ft
Area Per Cooling Capacity: 204.8 Sq.ft/Ton
Cooling Capacity Per Area: 0.0049 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 0.76 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 290 CFM
Total Building Vent. Air (10.34% of Supply): 30 CFM
Total Conditioned Air Space: 156 Sq.ft
Supply Air Per Unit Area: 1.8570 CFM/Sq.ft
Area Per Cooling Capacity: 207.1 Sq.ft/Ton
Cooling Capacity Per Area: 0.0048 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 0.75 Tons
Check Figures
Total Building Supply Air (based on a 20° TD): 340 CFM
Total Building Vent. Air (17.63% of Supply): 60 CFM
Total Conditioned Air Space: 114 Sq.ft
Supply Air Per Unit Area: 2.9828 CFM/Sq.ft
Area Per Cooling Capacity: 111.3 Sq.ft/Ton
Cooling Capacity Per Area: 0.0090 Tons/Sq.ft
Heating Capacity Per Area: 0.00 Btuh/Sq.ft
Total Heating Required With Outside Air: 0 Btuh
Total Cooling Required With Outside Air: 1.03 Tons