98MU018-D
98MU018-D
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
IND. Author Date Description
A JCN 1998 Initial Version
B
C EE 11/04/06 Addition of Index modification – Anthea Sdt/Blind version p°4 – Sensor current p°10 – Sensor resistance
value p°11 & 12.
D IQ 12/10/07 Change name of i2e into Amesys International
98MU018-D
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
CONTENTS
1/ AFTER SALES SUPPORT 3
1.1/ Service Request 3
1.2/ Request for after-sales support form 4
2/ TYPE OF MALFUNCTIONS 5
2.1/ Error Message List 5
2.2/ Possible other malfunctions 5
5/ WARRANTY CONDITIONS 14
5.1/ Warranty Card 15
5.2/ Log Installation Report 16
5.3/ Log Calibration Report 17
6/ DRAWINGS
ANTHEA (Standard) Set DWG N°5844-M 18
ANTHEA (Standard) Part list 19
ANTHEA (Standard) Mounting DWG N°6932-M 20
ANTHEA (Blind) Set DWG N°6640-M 21
ANTHEA (Blind) Part list 22
ANTHEA (Blind) Mounting DWG N° 6631-M 23
Main Log Board (Equipment) DWG N° 6655-I 24
Main Log Board (Electrical dwg) DWG N° 6255-E 25
Display Board (Equipment) DWG N° 7180-I 28
Display Board (Electrical dwg) DWG N° 7180-E 30
Probe and Hullfitting DWG N° D0343 31
98MU018-D - Page 2
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
1/ AFTER-SALES SUPPORT
- Perform, or have performed, the simple test procedure described in the relevant form
(refer to page 4)
♦ Cause of failure, if assessable based on your initial information, or instruction for further
testing.
♦ Service instructions if repairs can be performed outside our factory. Labour is not covered
in this case. Spares are supplied free-of-charge ex-works Marseille, if unit is still under
warranty. If no longer under warranty, spares are invoiced on spare parts price list basis.
♦ If repair is not possible outside our factory or if further investigation is necessary in house,
we will ask you to return unit to us for additional testing.
98MU018-D – Page 3
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
1.2/ Request for After-sales support form
Please, specify cable type used for installation : Two shielded pairs One shielded pair
Is there one or more junction boxes used for this installation : ………………………….
1/ Anthea Standard (with display) : Is there an error message displayed on the right hand screen and
what is it (please, check p°5) : …………………………………………………………
Anthea Blind : use a PC with BLASS software to visualize the error message (check p°5) :
………………………………………………………………………………………………
Please, forward the corrections points (refer to Log calibration report : see page 16)
98MU018-D – Page 4
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
2/ TYPE OF MALFUNCTION
Any possible fault of log is detected by a permanent self test and displayed on the 2 x 16-digit
lines LCD screen (located on the right hand side of the Anthea).
Measure fault :
This message appears in the event of a faulty analog component, or when sensor is out of
water (refer to page 6).
This message appears after a transmission fault between the display board and the measuring
board (refer to page 7).
Defect memory :
This message appears if the EPROM memory happens to be erased (Put in place strap E11 :
defect will disappear. Then, remove strap E11).
Sensor current :
This message appears when there is no more current on sensor. Check the sensor (inductor)
connections (refer to § sensor checking procedure 11 & 12).
98MU018-D – Page 5
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
3/ PRACTICAL SOLUTIONS TO MALFUNCTIONS
Check sensor’s
connections
Existing Short-circuit
Cable clamping on the
98MU018-D – Page 6
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
3.2/ Anthea displays « Defect Liaison Log »
98MU018-D – Page 7
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
3.3/ Anthea displays systematically « 0 knot »
98MU018-D – Page 8
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
3.4/ Anthea displays fluctuating speed
98MU018-D – Page 9
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
3.5/ Anthea displays lower speed
98MU018-D – Page 10
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
4/ SENSOR CHECKING PROCEDURE
This measurement is compulsory. To proceed with this measurement, do not use an auto ranging Ohmmeter.
Use an Ohmmeter with fix calibration values.
98MU018-D - Page 11 - 11 -
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
Resistance between E1 and E2 must be approximately equal to the double of the electrode shield’s resistance
Use a measure instrument in Ohmmeter position : Value to be obtained Measured value Calibre
Disconnect the sensor from the electronics
Measure the inductor resistance (blue and black wires) 2 K Ohms
SENSOR TYPE 48.1 About 200 Ohms ± 5% …………………..
SENSOR TYPE 65.2 About 150 Ohms ± 5% ……………………
LENS SENSOR About 150 Ohms ± 5%
Measure insulation between joint inductors and Electrode E2 > 5M ohms ……………………. 20 M Ohms
(white wire)
Measure insulation between joint inductors and Electrode E1 > 5M ohms …………………… 20 M Ohms
(red wire)
Measure insulation between joint inductors and inductor > 5M ohms …………………… 20 M Ohms
shield
Measure insulation between inductor shield and E1 > 5M ohms …………………… 20 M Ohms
Measure insulation between inductor shield and E2 > 5M ohms ……………………. 20 M Ohms
98MU018-D – Page 12
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
4.3/ Replacing the sensor.
(Please refer to drawing D0343 Page 31)
Tools required:
Pipe key N° 19 (9)
Grease.
Spares
Sensors
O-rings
Flat seal
Circlips
Work level:
INT
Time required:
2 hours
Personnel:
1 technician
Procedure
Dismantling
- Disconnect the 220 V power supply
- Disconnect the sensor
- Unscrew the screw (9)
- Remove the sensor up to the full extension of the link
- Close the valve
- Disconnect the link
- Remove the sensor
- Remove the circlips and the probe flange
Assembly
- Grease the 0-ring (6)
- Place the new sensor in the probe flange
- Insert the new circlips (15) and the new flat seal (7)
- Degrease the electrodes
- Place the sensor on the hull fitting
- Attach the link (10)
- Open the valve (4)
- Push the sensor and tighten the screw (9) and washer (20)
- Connect the sensor to the main cabinet (see Chapter 3.4)
- Restore the power supply
98MU018-D - Page 13
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
5/ WARRANTY CONDITIONS
• Procedure :
The warranty is valid during a period of twelve (12) months after installation with a
maximum of eighteen (18) months after the dispatching date from our factory, whichever
occurs first.
The warranty covers parts and labour for any item returned to our factory and used under
nominal conditions.
BEN provides a ten (10) years procurement warranty for above equipments and spares.
- Dismantling and transport of defective equipment to and from our factory, or transport
of warranty spares.
98MU018-D – Page 14
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
O/REF :
WARRANTY CARD
The Amesys/Ben equipment described below is guaranteed against • Equipment modification not in compliance with Amesys/BEN
faults and defects, under the following conditions : instructions, or by unauthorized parties.
• Improper equipment installation, or not in compliance with
Warranty coverage includes repair or replacement of defective parts at Amesys/BEN installation manual.
Amesys/BEN‘s discretion. • Improper use of equipment.
• Failure to return filled-out original of present warranty card, +
Warranty applies to Amesys/BEN instruments only, and not to their installation report
installation. Any equipment interfaced with or functioning along side + calibration report to Amesys/BEN, within 15 days of installation of
BEN instruments are not covered by the present warranty terms. equipment.
The present warranty does not cover risks resulting from the use or Dismantling and transport of equipment is not covered by the present
possession of Amesys/BEN equipment. warranty terms. Defective equipment can be returned to a certified
Amesys/BEN after sales service station, or to Amesys/BEN.
Warranty coverage is applicable for a period of 12 months from date of
installation of equipment, or maximum 18 months from date of dispatch A current list of certified Amesys/BEN After Sales Service Stations is
from Amesys/BEN premises. available from BEN or from any member of the Amesys/BEN
International Network.
The present warranty coverage is automatically cancelled in case of :
Serial number :
Sensor type : Start-up date :
Serial number :
Accessories : Stamp and signature
of Dealer :
Amesys/BEN
delivery note
date :
Amesys/BEN
delivery note N°
:
1st copy : To be filled-out and returned to BEN 2nd copy : SHIP : To be imperatively attached with the
instrument in case of return for repair to BEN.
98MU018-D – Page 15
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
LOG INSTALLATION REPORT
If on bulbe thickness :…….. Have the sensor and hullfitting been inspected before launching or
Dock drawning ? yes No
Draught : …………………………..m
Height above keel………………….m Distance : ……m
Date :……………………
The original report must be mailed to AMESYS/BEN. This is mandatory. AMESYS/BEN will not accept any
copy.
First copy : SHIP – Second copy : Servicing agent.
98MU018-D – Page 16
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
LOG CALIBRATION REPORT
REF : JOB N° Inter. Ref. :
Ship’s name : Log type : Scale : Cabinet S/N :
Type of vessel : Sensor type : Sensor S/N :
New Building n° : Shipyard : Accessories :
Length : Owner Date started
Distance sensor/cabinet : Flag : Working hours
Normal Overtime
Max. speed If trouble encountered during calibration, please issue separate service report
Actual speed (with ref to the earth) Indicated speed (with ref. to the water) Remarks
1 2 3 4 5 6 7 8 9 10 11 12
Trial Run Length Time Calculated Speed Start Stop Display (1)
N° Ref. Measured Sec. Speed On the Distance Time Speed Error (3) = x3600
mile Knots Indic. Counter Chrono Counter Chrono
(2)
1st run (9) = (7) – (5)
rd
3 run (9)
(11) = x3600
(10)
Averaged For average
value see
values formula hereafter
1st run (12)=(11)-(3)
Return
3rd run
Return
3rd run
if any
Averaged For average
value see
values formula hereafter
Formulas : 2 RUNS average speed = 1st.run.speed + return.run.speed 3 RUNS average speed = 1st .run.speed = 3rd .speed + return .speed
2 4 2
CORRECTIONS ADJUSTMENTS : Full scale Operations
……………………………………………………….
(indicate plus + or minus -) Mid scale details (if any)……………………………………………………
AFTER CALIBRATION :
Position of the potentiometer (after zero adjustment) : ………………………………………………………….
The original report must be mailed to AMESYS/BEN. This is mandatory. AMESYS/BEN will not accept any
copy.
First copy : SHIP – Second copy : Servicing agent.
98MU018-D – Page 17
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent
98MU018-D – Page 18
SERVICE MANUAL FOR ANTHEA STANDARD & BLIND VERSION
This document is the property of Amesys International. It shall not be reproduced nor communicated without its prior consent