You are on page 1of 1

One 

Za'abeel | 4597‐AAB‐SC‐07 Addendum 2
Structural Design Criteria.xmct
Section Page 2 of 5 
Design and Engineering Dept.
______________________________________________________________________________________________________________________________

Part 2 - Serviceability Requirements

Vertical Façade Types and Similar Structures

Element Loading Type Condition Limit Reference Remarks


AS 1288 / 
Short Duration  Shorter length of panel is in 
Glazing 4‐Edge Supported Lu/60 Appendix CW 
Out‐of‐Plane consideration
(Inhabit)
AS 1288 / 
Short Duration  Unsupported length measured 
Glazing 2‐Edge Supported Lu/60 Appendix CW 
Out‐of‐Plane from support to support
(Inhabit)
AS 1288 / 
Short Duration  Height of panel is in 
Glazing 1 Edge Supported h/30 Appendix CW 
Out‐of‐Plane consideration
(Inhabit)
Brittle  Short Duration  Appendix CW  Shorter length of panel is in 
4‐Edge Supported Lu/360
Panels Out‐of‐Plane (Inhabit) consideration
Unsupported length measured 
Flexible  Short Duration  Appendix CW 
4‐Edge Supported Lu/60 from support to support; For wall 
Panels Out‐of‐Plane (Inhabit)
cladding panel or ACP
Unsupported length measured 
Flexible  Short Duration  Appendix CW 
2‐Edge Supported Lu/60 from support to support; For wall 
Panels Out‐of‐Plane (Inhabit)
cladding panel or ACP
Vertical and  Unsupported length measured 
Short Duration  Appendix CW 
Horizontal  2‐End Supported Lu/200 from support to support 
Out‐of‐Plane (Inhabit)
Members (General)
Vertical and  Unsupported length measured 
Short Duration  Appendix CW 
Horizontal  2‐End Supported Lu/180 from member to member and for 
Out‐of‐Plane (Inhabit)
Members single glazing (Monolithic)
Vertical and  Unsupported length measured 
Short Duration  Appendix CW 
Horizontal  2‐End Supported Lu/200 from member to member and for 
Out‐of‐Plane (Inhabit)
Members double glazing (IGU)
Vertical and  Unsupported length measured 
Short Duration  Appendix CW 
Horizontal  2‐End Supported Lu/90 from support to support and for 
Out‐of‐Plane (Inhabit)
Members flexible panels
Vertical and  Unsupported length measured 
Short Duration  Appendix CW 
Horizontal  2‐End Supported Lu/360 from support to support and for 
Out‐of‐Plane (Inhabit)
Members brittle panels
Vertical and 
Short Duration  1 End Supported  Appendix CW  * Denominator varies with 
Horizontal  *2Lu
Out‐of‐Plane (Cantilever) (Inhabit) element type
Members
Unsupported length measured 
Horizontal  Long Duration In‐  Appendix CW 
2‐End Supported Lu/360 from support to support (Non‐ 
Members Plane (Inhabit)
trafficable)
Unsupported length measured 
Horizontal  Long Duration In‐  Appendix CW 
2‐End Supported Lu/1000 from support to support 
Members Plane (Inhabit)
(Trafficable)

Notes:
Short Duration Load includes but is not limited to wind loads, live loads
Long Duration Load includes but is not limited to selfweight, superimposed permanent loads
Brittle Panels includes but is not limited to glazing
Flexible Panels includes but is not limited to metal panels
Vertical and Horizontal Members are independent of material type as long as they are considered as façade elements
Vertical Façade and Similar Structures includes but is not limited to storefronts, vestibules, continuous curtain walls, etc.

Legend:
b ‐ s horter l ength of a  uni t pa nel
Lu ‐ Uns upported Length

8 of 100
TempVer20.0_012018 | Engineer: S.M.LomboyJr.