SUMMARY TABLE FOR DIMENSIONS AND EXTERNAL LOADS DOC N°: ST_GE1432_19

Client : RELIANCE INDUSTRIES LTD


PIPING CLASS : SSP01N Project : RELIANCE MJ FPSO
10000 psi System – HUB: ASTM A182 F51 Date : 11/11/2019
CLAMP: up to 14" AISI 4140 ; 16" and above AISI 4140M Rev. : 2
SEAL RING: ASTM A182 F51 PTFE COATED GALPERTI ENGINEERING
BOLTING: ASTM A193 Gr. B7M / A194 Gr. 2HM H.D.G. and FLOW CONTROL

NOMINAL PIPE PIPE HUB LENGTH HUB SEAL CLAMP BOLT CLAMP SEAL SEAL BW HUB BL HUB S.RING CLAMP Max. Loads
G-LOK®
+ SCHEDULE O.D. I.D. B.W. BLIND O.D. RIB THK WIDTH SIZE CLEAR. I.D. WIDTH Bending Axial Torque
SIZE WEIGHT (kg)
or W.T. (mm) A B ØQ C D GxE F ØJ K (KNm) (KN) (KNm)
X8GR67 8''-160 219.1 173.1 136.5 88.9 292.1 9.53 152.4 1-3/8"x357 259.6 177.1 34.93 24.7 33.5 1.70 59 29.21 656.59 30.69
X10H84 10''-160 273.0 215.8 152.4 108.0 346.1 9.53 190.5 1-3/4"x495,3 321.5 218.4 34.93 40.6 58.0 2.70 145 55.42 999.45 61.79
X12M102 12''-160 323.9 257.3 168.3 133.4 406.4 9.53 216 2"x571,5 373.3 262.9 34.93 63.0 103 2.30 225 69.82 1057.3 98.56
A-P112 14''-160 355.6 284.2 184.2 152.4 469.9 15.88 209.5 2"x520,7 389.6 288.3 41.28 93.0 162 5.50 175 87.30 1198.5 114.99
S130 16''-160 406.4 325.4 200.0 178.0 533.4 12.70 266.7 2-1/2"x685,8 473.5 332.2 38.10 144 254 3.90 440 103.51 1241.6 212.38
U144 18''-160 457.2 366.8 222.2 184.0 635.0 12.70 279.4 2-1/2"x685,8 526.3 370.3 38.10 239 384 5.20 450 116.87 1244.1 254.86
3V160 20''-160 508.0 408.2 228.6 178.0 660.4 12.70 235 2-1/4"x723,9 525.2 408.4 38.10 252 397 5.70 440 138.71 1327.3 220.16
Dimensions are in mm

Notes : 1) Design in accordance with ASME VIII Div.2 8) The maximum torsional moment refers to the dry friction coefficient between the hub-clamp,
2) This report is automatically generated by the Calculation Software coated seal ring and the maximum residual bolt load
3) Max. external loads refer to the rated pressure 69 MPa @ 130 °C 9) Min./ Max Design Temperature : -29/+130 °C
and calculated based on ASTM A694 Gr. F60 properties. 10) Design Max. Pressure : 69 MPa
4) The bending moment has been considered without the axial force 11) BW ends in accordance to ASME B16.25
5) The axial force has been considered without the bending moment 12) Bolt length for size ≥ 1.1/4" is suitable for tensioning tool equipment
6) See graph for linear interpolation of load acting simultaneously 13) All the hubs are of Non-Recessed type
7) Corrosion Allowance = 0 mm

Page 1 of 2
SUMMARY TABLE FOR DIMENSIONS AND EXTERNAL LOADS DOC N°: ST_GE1432_19
Client: RELIANCE INDUSTRIES LTD
Proj.: RELIANCE MJ FPSO
GRAPH OF THE ALLOWABLE AXIAL FORCE AND BENDING MOMENTS Date: 11/11/2019
IN COINCIDENTAL CONDITIONS REV.: 2
GALPERTI ENGINEERING
and FLOW CONTROL
The maximum values of bending moment and axial force that are provided for each size of each piping class are calculated
as the loads that the clamped connection can withstand separately, but in conjunction with internal pressure and torsion at
maximum design temperature. The bending moment has been therefore determined without the axial force, and vice versa.

When the two external loads act at the same time, linear interpolation between the maximum values is used
for intermediate loads as shown in the graph here below.

Bending
Moment Max Bending Moment and zero Axial Force
POINT A = axial force with bending moment
POINT B = bending moment with axial force
POINT A + B = axial and bending loads acting simultaneously

A+B
B

Max Axial Force and zero Bending Moment

Axial
A Force

Page 2 of 2