SAFETY VALVE DISCHARGE FORCE


CALCULATION CONTRACT NO: C17058

SYSTEM NO.: 1
DOC. NO.:

PROJECT: FPSO Carioca MV30

CLIENT:

LINE PARAMETERS

LINE NO.: xxxx

SOD: D

ORIFICE AREA: 0.0018406 m2

FLUID DENSITY: 800 Kg/m3

FLUID VELOCITY: 7.275 m/s

CALCULATIONS

RATIO OF MOLECULAR WT.


FLOW RATE TEMPERATURE FORCE
SL.NO. NODE NO. DAF SPECIFIC HEAT OF FLUID
(Wg) (T) (F)
(K) (M)

1 2120 2 10.71229 1.173 168.70 34.8 7234.280


2 2120 2 10.71229 1.178 324.40 18.4 11581.625
3 2120 2 10.71229 1.178 324.40 18.4 11581.625
4 2120 2 10.71229 1.178 324.40 18.4 11581.625
5 2120 2 10.71229 1.178 324.40 18.4 11581.625
6 2120 2 10.71229 1.178 324.40 18.4 11581.625
7 2120 2 10.71229 1.178 324.40 18.4 11581.625
8 2120 2 10.71229 1.178 324.40 18.4 11581.625
9 2120 2 10.71229 1.178 324.40 18.4 11581.625
10 2120 2 10.71229 1.178 324.40 18.4 11581.625
11 2120 2 10.71229 1.178 324.40 18.4 11581.625
12 2120 2 10.71229 1.178 324.40 18.4 11581.625
13 2120 2 10.71229 1.178 324.40 18.4 11581.625
14 2120 2 10.71229 1.178 324.40 18.4 11581.625
15 2120 2 10.71229 1.178 324.40 18.4 11581.625

Formula:-

Where DAF=Dynamic Amplification Factor ( 2 )


Wg=Flow rate Kg/s
K=Ratio of specific heat = Cp/Cv
T=Temperature (OC)
M= Molecular Wt. of the fluid.
SOD= Standard Orifice Designation

0 10/10/2013 ISSUED FOR REVIEW XX YY ZZ


REV DATE DESCRIPTION PREPARED BY CHECKED BY APPROVED BY