You are on page 1of 13

Project 1

Partner for Contact:


Order No.:
Company:
Customer No.:

Date: 22.02.2019
Operator:
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Table of contents

Project 1
Project Cover 1
Table of contents 2
V-TAC 5726 V-TAC 600W LED Floodlight PREMIUM Black 6000K
Luminaire Data Sheet 3
Room 1
Summary 4
Input Protocol 5
Luminaire parts list 6
Luminaires (layout plan) 7
3D Rendering 8
Room Surfaces
Workplane
Isolines (E) 9
Value Chart (E) 10
Floor
Isolines (E) 11
Greyscale (E) 12
Calculation Grid 1
Value Chart (E, Perpendicular) 13

Page 2
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

V-TAC 5726 V-TAC 600W LED Floodlight PREMIUM Black 6000K / Luminaire Data
Sheet

Luminous emittance 1:

Luminaire classification according to CIE: 100 Luminous emittance 1:


CIE flux code: 57 90 99 100 100
600W LED Floodlight
V-TAC Classic PREMIUM
Black Body
SMD
6000K

Page 3
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Room 1 / Summary

Height of Room: 9.000 m, Light loss factor: 0.57 Values in Lux, Scale 1:1413

Surface  [%] Eav [lx] Emin [lx] Emax [lx] u0


Workplane / 30 7.11 159 0.240
Floor 20 30 7.09 160 0.239
Ceiling 70 23 3.75 335 0.163
Walls (4) 50 33 19 199 /

Workplane:
Height: 0.000 m
Grid: 128 x 128 Points
Boundary Zone: 0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 1.127, Ceiling / Working Plane: 0.776.

Luminaire Parts List

No. Pieces Designation (Correction Factor)  (Luminaire) [lm]  (Lamps) [lm] P [W]
V-TAC 5726 V-TAC 600W LED Floodlight
1 26 48000 48000 600.0
PREMIUM Black 6000K (1.000)
Total: 1248000 Total: 1248000 15600.0

Specific connected load: 0.77 W/m² = 2.61 W/m²/100 lx (Ground area: 20130.00 m²)

Page 4
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Room 1 / Input Protocol

Height of working plane: 0.000 m


Boundary Zone: 0.000 m

Light loss factor: 0.57

Height of Room: 9.000 m


Ground area: 20130.00 m²

Surface Rho [%] from ( [m] | [m] ) towards ( [m] | [m] ) Length [m]
Floor 20 / / /
Ceiling 70 / / /
Wall 1 50 ( 0.000 | 0.000 ) ( 183.000 | 0.000 ) 183.000
Wall 2 50 ( 183.000 | 0.000 ) ( 183.000 | 110.000 ) 110.000
Wall 3 50 ( 183.000 | 110.000 ) ( 0.000 | 110.000 ) 183.000
Wall 4 50 ( 0.000 | 110.000 ) ( 0.000 | 0.000 ) 110.000

Page 5
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Room 1 / Luminaire parts list

26 Pieces V-TAC 5726 V-TAC 600W LED Floodlight


PREMIUM Black 6000K
Article No.: 5726
Luminous flux (Luminaire): 48000 lm
Luminous flux (Lamps): 48000 lm
Luminaire Wattage: 600.0 W
Luminaire classification according to CIE: 100
CIE flux code: 57 90 99 100 100
Fitting: 1 x V-TAC 600W LED Floodlight PREMIUM
Black 6000K (Correction Factor 1.000).

Page 6
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Room 1 / Luminaires (layout plan)

Scale 1 : 1309

Luminaire Parts List

No. Pieces Designation


1 26 V-TAC 5726 V-TAC 600W LED Floodlight PREMIUM Black 6000K

Page 7
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Room 1 / 3D Rendering

Page 8
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Room 1 / Workplane / Isolines (E)

Values in Lux, Scale 1 : 1309


Position of surface in room:
Marked point:
(0.000 m, 0.000 m, 0.000 m)

Grid: 128 x 128 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


30 7.11 159 0.240 0.045

Page 9
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Room 1 / Workplane / Value Chart (E)

Values in Lux, Scale 1 : 1309


Not all calculated values could be displayed.

Position of surface in room:


Marked point:
(0.000 m, 0.000 m, 0.000 m)

Grid: 128 x 128 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


30 7.11 159 0.240 0.045

Page 10
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Room 1 / Floor / Isolines (E)

Values in Lux, Scale 1 : 1309


Position of surface in room:
Marked point:
(0.000 m, 0.000 m, 0.000 m)

Grid: 128 x 128 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


30 7.09 160 0.239 0.044

Page 11
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Room 1 / Floor / Greyscale (E)

Scale 1 : 1309
Position of surface in room:
Marked point:
(0.000 m, 0.000 m, 0.000 m)

Grid: 128 x 128 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


30 7.09 160 0.239 0.044

Page 12
Project 1
22.02.2019

Operator
Telephone
Fax
e-Mail

Room 1 / Calculation Grid 1 / Value Chart (E, Perpendicular)

Values in Lux, Scale 1 : 1388


Not all calculated values could be displayed.

Position of surface in room:


Marked point: (0.000 m, 0.000 m,
0.000 m)

Grid: 299 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


29 7.04 109 0.24 0.06

Page 13

You might also like