You are on page 1of 2

RA12-200(12V200Ah)

Specification
Cells Per Unit 6
Voltage Per Unit 12
Nominal Capacity 200Ah@10hour-rate to 1.80V per cell @25℃
Weight Approx. 60.0 Kg (Tolerance±1.5%)
Internal Resistance Approx. 4 mΩ
Terminal F16(M8)/F10(M8)
Max. Discharge Current 2000A (5 sec)
Short Circuit Current 3430A RA series is a general purpose battery with
12 years design life in float service. It meets
Design Life 12 years (Float charging)
with IEC, JIS, BS and YDT standards. With
Recommended Maximum Charging 60 A advanced AGM valve regulated technology
Current and high purity raw material, the RA series
C3 155.1AH battery maintains high consistency for better
C5 178.5AH performance and reliable standby service
Reference Capacity C10 200.0AH life. It is suitable for UPS/EPS, Telecom,
C20 212.0AH power grid, medical equipment, emergency
Standby Use Voltage
13.6 V~13.8 V @ 25℃ light and security system applications.
Temperature Compensation: -3mV/℃/Cell
14.6 V~14.8 V @ 25℃
Cycle Use Voltage
Temperature Compensation: -4mV/℃/Cell
Discharge: -20℃~60℃
Operating Temperature Range Charge: 0℃~50℃
Storage: -20℃~60℃
Normal Operating Temperature Range 25℃±5℃
RITAR Valve Regulated Lead Acid (VRLA) batteries can
be stored for up to 6 months at 25℃ and then recharging
Self Discharge is recommended. Monthly Self-discharge ratio is less
than 3% at 25℃.Please charge batteries before using.

Container Material A.B.S. UL94-HB, UL94-V0 Optional.

Dimensions
Φ20 Length 522±2mm (20.6 inches)
205 M8 Width 240±2mm (9.45 inches)
522 240
Height 219±2mm (8.62 inches)
5

Total Height 224±2mm (8.82 inches)


Terminal Value
140
224
219

M5 6~7 N*m
M6 8~10 N*m
M8 10~12 N*m
F10 Terminal
Unit: mm

Constant Current Discharge Characteristics : A (25℃)


F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 442.2 347.9 209.8 123.1 73.8 54.7 44.4 37.5 25.1 21.3 10.9
1.65V 429.0 338.8 205.2 120.9 72.7 54.0 43.9 37.1 24.8 21.1 10.8
1.70V 411.7 326.8 199.1 117.8 71.3 53.0 43.2 36.5 24.5 20.8 10.7
1.75V 389.3 311.2 191.2 113.9 69.4 51.7 42.2 35.7 24.0 20.5 10.6
1.80V 360.8 291.2 180.8 108.7 66.9 50.0 40.9 34.7 23.4 20.0 10.4
1.85V 325.0 265.8 167.6 102.0 63.6 47.8 39.2 33.4 22.7 19.4 10.1
Constant Power Discharge Characteristics : WPC (25℃)
F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 763 617 387 234 142 106 86.6 73.4 49.7 42.5 21.9
1.65V 760 614 384 232 141 105 86.0 72.9 49.3 42.2 21.7
1.70V 737 597 375 227 139 104 84.7 71.9 48.7 41.7 21.5
1.75V 710 577 363 220 135 102 83.1 70.7 47.9 41.0 21.2
1.80V 669 547 347 211 131 98.7 80.9 68.9 46.9 40.1 20.8
1.85V 614 507 325 200 126 94.7 77.8 66.5 45.4 38.9 20.3
(Note) The above characteristics data are average values obtained within three charge/discharge cycle not the minimum values.
RA12-200(12V200Ah)
Discharge Characteristics Curve Charge Characteristic Curve For Standby Use
Temperature:25℃(77℉) Temperature:25℃(77℉)
(V/cell)
120 0.14 2.40
2.16 Charge Volume

Charge Voltage (VPC)


Charge Current (CA)
Terminal Voltage (v )

100 0.12 Charge Voltage 2.30

Charge Volume (%)


2.00

80 0.10 2.20
1.84
0.1C 0.05C
1.68
0.25C 0.17C 60 0.06 2.10
0.55C After 50% Discharge
3C 2C 1C After 100% Discharge
1.52 40 0.04 2.00

1.36 20 0.02 1.90


Charge Current
0
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 0 0.00 1.80
min h 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Discharge Time Charging Time(h)

Cycle Life In Relation To Depth Of Discharge Relationship Between Charging Voltage And Temperature
2.70
120

100 2.60

Charge Voltage (v )
Cycle use
80 2.43~2.47VPC@25℃
Capacity(%)

2.50

60
100% 50% 30%
DOD DOD DOD 2.40
40

2.30
20
Float charging
2.27~2.30VPC@25℃
0 2.20
200 400 600 800 1000 1200 1400
-20 -10 0 10 20 30 40 50

Number of Cycles Temperature (℃)

Temperature Effects On Capacity Storage Characteristics


120 100

100 0℃
0 .1 C A 80
Capacity (% )

Capacity (% )

80 0 .2 C A
60
10℃
60
20℃
1 .0 C A 40
40℃ 30℃
40
2 .0 C A
3 .0 C A 20
20

0 0
-20 -10 0 10 20 30 40 50 0 2 4 6 8 10 12 14 16 18 20 22 24
Temperature (℃) Storage Time(months)

Effect Of Temperature On Long Term Life Life Characteristics Of Standby Use


Testing conditions: float charging Temperature: 25℃(77℉)
20
120
Lift Expectancy (y ears)

16 100

80
12
Capacity(%)

60
8
40

4
20

0 0
0 10 20 30 40 50 0 2 4 6 8 10 12
Temperature(℃) Life expectancy (years)

(Note) All above information shall be changed without prior notice, Ritar reserves the right to explain and update the latest information.

SHENZHEN RITAR POWER CO.,LTD. Add: 10th Floor, Tower C, 1st Building, Software Industry Base, No.81, Xuefu Road, Nanshan District, Shenzhen,
Guangdong, China 518057
URL: www.ritarpower.com Tel: +86-755-33981668/83475380 Fax: +86-755-83475180 E-mail: sales@ritarpower.com Version 17A-0

You might also like