You are on page 1of 2

Supported by the advanced technologies Technical data Specifications

of Toray, Type: TR-8000 offers Monitor section


Display temperature indicator: 0.0 to 99.9 °C
Power supply:
Max. power consumption:
110-120 / 220-240 V 50/60 Hz
1.5 kVA

comfortable dialysis treatment to patients Dialysate flow meter:


Venous pressure indicator:
300 to 800 mL/min
-200 to +400 mmHg
Dimensions (W x H x D):
main body only
322 x 1,378×375 mm

and easy operation to medical staff. Arterial pressure indicator:


Dialysate pressure indicator:
-400 to +500 mmHg
-400 to +400 mmHg
Weight:
Pressure of supplied water:
Max. 85 kg
0.1 to 0.3 Mpa Single Patient
Dialysis Machine
UF rate indicator: 0.00 to 5.00 L/h Flow rate of supplied water: 800 mL/min or greater
UF goal-setting device: 0.00 to 40.00 L Temperature of supplied water: 5 to 30 °C
Syringe pump flow-rate indicator: 0.0 to 9.9 mL/h Quality of supplied water: equivalent to or better than
ISO13959 Guidance
Safety design Range of dialysate temperature regulation:
Status lamp (4 colors) 33 to 40 °C
Self-test of hydraulic line Range of dialysate flow rate regulation:
TMP monitor/ TMP alarm 300 to 700 mL/min
Compliance with IEC60601-1, IEC60601-2-16 requirements Range of UF rate regulation: 0.00 to 5.00 L/h
Range of dialysate conductivity regulation
Options Acetate dialysate and Bicarbonate dialysate:
Automatic Blood Pressure Monitor 13.0 to 16.0 mS/cm in 1-9 steps
Bicarbonate Cartridge Holder (in increments of 0.3 mS/cm)
On-Line HDF Substitution pump rate setting range:
On-Line HDF and Substitution shortage sensor 0.0 to 18.0 L/h Offer a Reliable and
Data communications
Endotoxin Retentive Filter Leak Test Function
(On-Line HDF option)
Substitution goal amount setting range:
Safety Treatment
Kt/V Indication
Blood Volume Monitor


0.01 to 99.99 L
(On-Line HDF option)
by Japanese Technology
Range of blood flow rate regulation:
Accessories Inner Diameter 8.0 mm 0, 30 to 600 mL/min
Priming funnel Inner Diameter 6.5 mm 0, 20 to 400 mL/min
Holder for ETRF Range of syringe flow regulation:
ETRF cover 0.0 to 9.9 mL/h
Handle (with rapid function)
Concentrate tray Available syringe size: 10 mL/ 20 mL/ 30 mL
Disinfectant bottles Air bubble detector: Ultrasonic detection system
Disinfectant bracket Sensitivity Greater than 0.020 mL
Concentrate centralized piping bracket Greater than 0.3 μL
Holder for BVM (Continuous air bubbles)
Nurse call cable (Under conditions of blood flow rate 200 mL/min)
Baskets for blood pressure monitor cuff Blood leak detector: Photoelectric detection system
Sensitivity Greater than 300 ppm
(Ht. 32 % ±2 %, 37 °C condition)
Disinfection: Hot water disinfection
or chemicals

Type: TR-8000 standard Type: TR-8000 Exporter/Manufacturer: Type: TR-8000


with On-Line HDF and Bicarbonate Toray Medical Co., Ltd.
4-1, Nihonbashi-Honcho 2-chome, Chuo-ku, Tokyo 103-0023, JAPAN
Cartridge Holder Options Tel: +81-3-6262-3830
Printed in Japan 1808 (G1)
TORAY’s Reliable and Safety Volumetric UF Control Simple and Clean Treatment based on
(Closed circuit system) advanced technology
Useful function for comfortable dialysis treatment
UPS (Uninterruptible Power System)
The backup power supply allows automatically the
operation of blood pump, syringe pump, LCD touch
Bicarbonate On-Line HDF
panel, clamp of blood tubing line, displaying alarm Cartridge Holder On-Line HDF treatment
Bicarbonate is performed by putting
message, alarm sound and status lamp at time of
concentrated solution an additional substitution
power failure.
is supplied by using pump, and making the
NaHCO3 powder in a purifier dialysate through
Air bubble detector cartridge type container. 2 pcs of ETRF (Endotoxin
The detector is integrated with venous clamp. 760mm
Position of the holder Retentive Filter)
In order to avoid misfitting of blood tube. is 760 mm from the connected in series.
caster to set bicarbonate
cartridge easily.
clamp
Kt/V indication
Kt/V indicated on the
The UF control of the TR-8000 is supported by a “Closed circuit
Drip chamber level display.
system” to ensure the accurate removal of excessive fluid.
Originally invented and developed by Toray, this system has been Bypass nozzle cover Drip chamber fluid
accepted worldwide as the reliable technology for UF control. The cover is designed for level adjustment of
dialyzer coupler nozzle to arteriovenous drip
The primary characteristic of each chamber has a silicone prevent contamination. chamber can be adjusted
membrane to separate fresh and used dialysate. These two conveniently by screen
chambers alternately prepare fresh dialysate and discharge the used operation.
one, continuously keeping the dialysate circuit closed. As the pre-
determined quantity of UF will be drawn from such closed circuit,
the targeted removal of excessive fluid is accomplished. Various profile (chart) Automatic Blood
The various profiles, such as UF, Pressure Monitor
Easy Maintenance Mode Dialysate, Bicarbonate, Blood
flow rate and Syringe can be
BVM (Blood Blood pressure is mea-
sured automatically, and
Volume Monitor)
programmed. the monitor indication
During hemodialysis, this
monitor is capable of screen summarizes and
continuous noninvasive displays the latest blood
monitoring percent pressure measurement
changes in blood volume result.
(ΔBV), the graph of ΔBV
is indicated to know the
Caster base cover
event of decreased ΔBV
Non-painted plastic cover
or abnormal changes in
is equipped to improve
chemical resistance. ΔBV.
Maintenance Window
Operation of each compo-
nent and indication value is
displayed on maintenance
window.