You are on page 1of 10

INTERACTIVE SCHEMATIC

Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.

Click here to save a copy of


EC-C2 E-C60 this interactive schematic
EC-C3
to your desktop
E-C61

VIEW ALL CALLOUTS

EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.

ELECTRICAL SYMBOLS BASIC HYDRAULIC


HOTKEYS (Keyboard Shortcuts) COMPONENT SYMBOLS
T

Pressure Temperature Level Flow


Pump

FUNCTION KEYS
Switch Switch Switch Switch Circuit Breaker
or Motor Variability

Click here to view the


Zoom In “CTRL” / “+” Schematic Symbols
Fluid
Conditioner
Spring
(Adjustable)

Zoom Out “CTRL” / “-” and Definitions page

Fit to Page “CTRL” / “0” (zero)


Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
SCHEMATIC SYMBOLS AND DEFINITIONS

VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC


ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

MAIN AUX.
Line Restriction
PILOT CONTROL 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump

Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated

Internal Hydraulic Pneumatic


Simplified Complete Supply Pressure Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)

Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
a normally open reed switch; it opens the contacts of a normally closed reed switch.
harness (C1, C2, C3, ...)
L-C12
Sender: A component that is used with a temperature or pressure gauge. 3E-5179
The sender measures the temperature or pressure.
T Its resistance changes to give an indication to the gauge of the temperature or pressure. 5A
Component
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. Fuse (5 Amps) 9X-1123 Part Number
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close the switch part of the relay. 325-AG135 PK-14
Harness identification code:
This example indicates wire group 325, Wire Gauge
Solenoid: A solenoid is an electrical component that is activated by electricity. wire 135 in harness "AG". Wire Color
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.
KENR9688
July 2013

336D and 336D2 Excavator


Hydraulic System
336D: 336D2:
WRK1-UP WDC1-UP
EFT1-UP YCF1-UP
PGW1-UP XBH1-UP
FAR1-UP
ZCT1-UP
TLY1-UP

Quick Coupler

© 2013 Caterpillar, All Rights Reserved Printed in U.S.A.


COMPONENT TABLE

Component Locations
Part Machine Schematic
Description
Number Location Location
Accumulator Gp 164-6981 1 A-5
Filter Gp - Oil (Case Drian) 126-2075 2 A-6
Filter Gp - Oil (Hydraulic Return)) 188-4140 3 A-7
Filter Gp - Oil (Pilot) 158-8987 4 A-4
Manifold Gp - Control (Pilot Oil) 215-5037 5 A-6
Motor Gp - Piston (Fan) 234-4638 6 A-8
Motor Gp - Swing 200-3373 7 F-6
Motor Gp - Travel (LH) 271-6376 8 F-6
Motor Gp - Travel (RH) 271-6376 9 F-3
Pump Gp - Piston (Hydraulic Fan) 259-0815 10 B-3
Pump Gp - Piston (Main) 283-6116 11 B-2
Swivel Gp 234-4440 12 E-4
Valve Gp - Check (Oil Cooler Bypass) 190-7745 13 A-8
Valve Gp - Load Control (Boom) 255-5683 14 D-2
Valve Gp - Load Control (Stick) 255-5680 15 D-6
Valve Gp - Main Control 285-1536 16 C-2
Valve Gp - Pilot (Travel) 270-5947 17 E-8
Valve Gp - Pilot Control (Left Joystick) 270-5951 18 C-8
Valve Gp - Pilot Control (Right Joystick) 270-5952 19 C-7
Valve Gp - Pressure Reducing (Boom, Swing Priority) 232-4102 20 B-4
Valve Gp - Shuttle 259-7732 21 B-4
Valve Gp - Shuttle (Cab) 185-0462 22 D-8
Valve Gp - Swing Cushion 158-9085 23 F-6
Valve Gp - Travel Counterbalance (LH) 204-2819 24 E-5
Valve Gp - Travel Counterbalance (RH) 204-2819 25 E-3
Attachments: Quick Coupler
Valve Gp - Solenoid & Manifold (Quick Coupler) 328-2035 26 E-3
Note: Check Part Number In The Part Manual For Your Specific Machine.
TAP TABLE

Tap Locations
Pressure, Sampling, and Sensor
Tap Schematic
Description
Number Location
AA Pilot Filter Pressure A-5
BB Drive Pump Pressure D-2
CC Power Shift Pressure A-2
DD Idler Pimp Pressure A-2
SOS Oil Sampling Port A-4
8 7 6 5 4 3 2 1
SWING MOTOR TRAVEL MOTOR (LEFT) TRAVEL MOTOR (RIGHT)
BUCKET CYLINDER STICK CYLINDER (7) MOTOR GP
SWING
PG 200-3373

DR (9) MOTOR GP
(8) MOTOR GP TRAVEL (RH)
R.C.V-C TRAVEL (LH) 271-6376
271-6376
F F
MU

BG AG
AL3 BL3 Pp3 Pp3
AR3 BR3 UNLOCK LOCK

B1 DR A1 (23) VALVE GP T1 T1
BOOM CYLINDER SWING CUSHION T2 T2
158-9085
C1 C2

BG BG
AG AG

B A P T
TRAVEL BRAKE TRAVEL BRAKE
(25) VALVE GP
A B B A TRAVEL COUNTERBALANCE (RH) (26) VALVE GP
AR4 BR4 BL2 AL2 (24) VALVE GP 204-2819 SOLENOID & MANIFOLD
TRAVEL COUNTERBALANCE (LH) (QUICK COUPLER)
E E
204-2819 328-2035

(17) VALVE GP BL1 AL1 BR1 AR1


PILOT (TRAVEL)
270-5947
TP TT (12) SWIVEL GP
234-4440
TRAVEL(L) TRAVEL(R)

(15) VALVE GP AR4


LOAD CONTROL
(STICK) aL2 aL1 aR4 (14) VALVE GP
255-5680 LOAD CONTROL
(BOOM)
255-5683
BACK FWD FWD BACK
T1 T5 T2 T4 T6 T3 AR1 aR3 R.C.V-B
AL2 AL1
aL1 bL1 bR1 aR1 R.C.V-A
BL3 AL3 BL2 BL1 BR4
aR1 BR1 BR3 AR3
D PRESSURE SWITCH PRESSURE SWITCH
SDr SPi BR2 AR2 BPi BR5 AR5
D
T AL4 SP3 aL3 Di4 Pi4 aR2 Pi1 BP3 aR5 R3
aL4 (UP) (IN) (L) (REV) (REV) (CLOSE) (DOWN) BDr BP2 (IN)

STICK DRIFT REDUCTION BOOM DRIFT REDUCTION BP1 BT

(18) VALVE GP (19) VALVE GP


PILOT CONTROL PILOT CONTROL
(LEFT JOYSTICK) (RIGHT JOYSTICK)
(Dimensions: 39 inches x 28 inches)

270-5951 270-5952
JLP JLT JRP JRT
STICK SWING BUCKET BOOM
KENR9688

C C
OUT IN R L OPEN CLOSE DOWN UP
(16) VALVE GP

TRAVEL(R)
JL1 JL3 JL2 JL4 JR4 JR2 JR3 JR1

BOOM(1)
TRAVEL(L)
MAIN CONTROL

STICK(2)
BUCKET
BOOM(2)

STICK(1)
285-1536

ATCH
SWING
MAIN
RELIEF

(OUT) (R) (FWD) (OPEN) (UP) (OUT)

A1 A2 A3 A4 A5 A6 A7 A8 Di2 Pi2 Pi3 Di3 DST bR2 Di1 bR5


bR1
bL2 bL1 bR3 bR4 HR
HL bL4 bL3 PL PR
(22) VALVE GP
SHUTTLE
185-0462
30 Page,

B1 B2 B3 B4 B5 B6 B7 B8
Pi1 (11) PUMP GP
PISTON (MAIN)
HR 283-6116
(21) VALVE GP (10) PUMP GP PR
B aR3 aR4 bR3 bR4 bL3 bL2 bL4 aL2 SHUTTLE B
A1 B2 A2 PISTON PRESSURE
P2 Pi1 P-IN PSA2 DR1 PSA1 259-7732 HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
(HYDRAULIC FAN) SENSOR
TRAVEL SPEED SWING L1 259-0815 PILOT PUMP OUTPUT
IMPLEMENT & LEFT TRAVEL PUMP OUTPUT
PRIORITY T-OUT2 DR2 (20) VALVE GP L FAN PUMP OUTPIT
R.C.V-C POWER SHIFT CONTROL CIRCUIT
PRESSURE REDUCING
(TRAVEL)

D0 Ps1
(SWING)

PRESSURE SWITCH SUPPLY LINE


R.C.V-B a4
(BOOM, SWING STICK CONTROL & STICK CYLINDER CIRCUIT
C T
ACTIVATION

LEFT TRAVEL CONTROL & LEFT TRAVEL MOTOR CIRCUIT


B a1
NO.1

NO.2

HYDRAULIC

PRIORITY)
(LOCK)

ATTACHMENT CONTROL CIRCUIT

BB
NO.3

232-4102 SWING CONTROL & SWING MOTOR CIRCUIT

P1 P2 M1 DRAIN / RETURN LINE


B G SWING BRAKE CIRCUIT
IMPLEMENT & RIGHT TRAVEL PUMP OUTPUT
A SLOW RETURN BYPASS RIGHT
TRAVEL SPEED CONTROL CIRCUIT
BUCKET CONTROL & BUCKET CYLINDER CIRCUIT
S PUMP Psv RIGHT TRAVEL CONTROL & RIGHT TRAVEL MOTOR CIRCUIT
R.C.V-A D E F P1 BOOM CONTROL & BOOM CYLINDER CIRCUIT
(13) VALVE GP
CHECK (OIL (1) ACCUMULATOR GP LINE PATTERNS
PAC a3
COOLER BYPASS) 164-6981 CC Pressure Line
190-7745 OIL COOLER
DR3 DR4 Pi2 DR5 T-OUT1 DR6 (4) FILTER GP LEFT M2
OIL (PILOT) PUMP DD Pilot / Load Sensing Pressure

Drain / Return Lines


158-8987 a2
DR1 DR L3 L2 A4 S1 D1 Ps2 a5 Component Group
(5) MANIFOLD GP OUT IN
Dr1 CALLOUTS
CONTROL (PILOT OIL)
A 215-5037
A
PRESSURE
YY Taps (Pressure, Sampling, Sensor - by letter)
(6) MOTOR GP SENSOR Callout Number
PISTON (FAN) (2) FILTER GP T (52) VALVE GP - CONTROL
Component

(3) FILTER GP PC PL (Machine Location from Name


RETURN PG
Component LocationsTable)
138-1234
234-4638 OIL Part Number

OIL
(CASE DRAIN)
B A (HYDRAULIC THIS SCHEMATIC IS FOR THE 336D AND 336D2 EXCAVATOR HYDRAULIC SYSTEM
RETURN)
126-2075 AA SOS HL
ATTACHMENT: QUICK COUPLER
188-4140
DRAIN Pi2 MEDIA NUMBER: KENR9688
SCHEMATIC PART NUMBER: 344-4216, CHANGE: 00, VERSION: HE
Components are shown installed on a fully operable machine with the key and engine off, with parking brake set.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.

8 7 6 5 4 3 2 1
MAIN PUMP - RIGHT SIDE VIEW
VIEW ALL CALLOUTS

11 CC 2 3 4

BB 10 DD AA SOS
MAIN CONTROL VALVE - REAR VIEW
VIEW ALL CALLOUTS
16

21 13 5 1 20
MACHINE - TOP VIEW (WITH ATTACHMENT)
VIEW ALL CALLOUTS

15 22 18

17

19

14 7 23 12 26
MACHINE - TOP RIGHT VIEW
VIEW ALL CALLOUTS

24

25

You might also like