You are on page 1of 2

CONNECTION DESIGN AS PER BS EN 1993-1-8:2005

DESIGN DATA

Structural steel grade = S275


Yeid Strength = 275 N/mm²
Ultimate Tensile Strength = 360 N/mm²
Modulus of elasticity of steel , E = 210000 N/mm²

Max tension = 4.71 KN Refer Attahed staad out put


Max Shear = 7.7 KN
Max MZ = 0.62 KNm
BOLT CHECK FOR SHEAR
Design Criteria = Fv,Ed < Fv,Rd
Total Design Shear Force = 7.7 KN
Shear Due To moment = 0
= 0.00 KN
Number Bolt provided = 2
Dia of Bolt = 16 mm
Area of rod = 201.0619 mm²
Design Shear per Bolt (Fv,Ed) = 3.85 KN

Design shear resistance per bolt ( Fv,Rd) =

fub = 800 N/mm² Refer Table 3.1 BS EN 1993-1-8:2005


ƳM2 = 1.25 Refer Table 2.1 BS EN 1993-1-8:2005
Fv,Rd = (0.6 x 800 x 0.75 x A )/1.25
= 57.91 KN
(Fv,Ed) 3.85 KN < 57.91 KN ( Fv,Rd)
HENCE BOLT SAFE SHEAR
BOLT CHECK FOR BEARING
Design Criteria = Fv,Ed < Fb,Rd
Plate thickness (t) = 12 mm
Design Bearing Resistance per bolt ( Fb,Rd) =

Ultimate Tensile Strength (fu) = 510 N/mm²


ɑb = 1 Refer Table 3.4 BS EN 1993-1-8:2005
( Fb,Rd) = 109.6704 KN
(Fv,Ed) 3.85 KN < 109.67 KN ( Fb,Rd)
HENCE BOLT SAFE BEARING

BOLT CHECK FOR TENSION


Design Criteria = Ft,Ed < Ft,Rd

Design Tension Resistance per bolt ( Ft,Rd) =

K2 = 0.63 Refer Table 3.4 BS EN 1993-1-8:2005


Design Tension Resistance per bolt ( Ft,Rd) 60.80 KN
Design of Tensile force per rod ( Ft,Ed)
Direct Tension = 4.71 KN
Direct Tension Per bolt = 4.00
= 1.18 KN
Tension Due To moment = 0.271/(0.05X1)
= 5.42 KN
Total Tension per rod = 6.60 KN
( Ft,Ed) = 6.60 KN
( Ft,Ed) 6.60 KN > 60.80 KN ( Ft,Rd)
HENCE BOLT SAFE TENSION

BOLT COMBINE SHEAR AND TENSION CHECK


Fv,Ed + Ft,Ed <1
Fv,Rd 1.4x Ft,Rd
3.85 + 6.60 = 0.14
57.91 85.12
HENCE BOLT SAFE IN COMBINE SHEAR AND TENSION

WELD CAPACITY CHECK


Design Criteria = Fw,Ed < Fw,Rd
Design weld resistance per unit length (Fw,Rd) = fvw.d x a
fvw.d = 220 0 Refer clause 4.5.3.3 BS EN 1993-1-8:2005
a = 6 mm
Fw,Rd = 1320 N/mm
Length of the weld = 150 mm
Total weld resistance (Fw,Rd) = 198 KN
> 4.71 KN
HENCE OK