Design of Two-Way Slab by ACI Moment Coefficient

JOB INFORMATION
PROJECT ENGR K.L.L.A JOB NO 3
SUBJECT Design of Slab, S15 DATE 10/10/2020 SHT NO 15

DESIGN PARAMETERS SUPPORT CONDITIONS

CASE 1 CASE 2 CASE 3


f'c = 28 MPa Compressive strength of concrete
fy = 414 MPa Yield strength of steel bar
fb = 12 mm Bar diameter CASE 4 CASE 5 CASE 6
t= 100 mm Thickness of slab
L= 5.68 m Longer dimension of slab
B= 5.10 m Shorter dimension of slab CASE 7 CASE 8 CASE 9
CASE = 8 See support conditions
s max = 300 Maximum spacing of reinforcement Ratio(B/L) = 0.90
b= 1000 mm-strip Width of slab m = 0.90
d= 74 mm-strip Effective depth of slab

DESIGN LOADS DUCTILITY REQUIREMENTS


Live Load = 2.40 KPa 0.75 [ 510b1f'c ]
rmax =
Ceiling = 0.48 KPa fy(600 + fy)
Utilities = 0.15 KPa 1.73 = 0.02169
Topping = 0.00 KPa rmin = 1.4/fy
Flr Fin = 1.10 KPa = 0.0034
Mov. Part = 0.50 KPa rmin = (f'c)0.5/4fy
Others = 0.00 KPa = 0.0032
Slab = 2.76 KPa rmin = 0.0034 governs
Total DL = 4.99 KPa

MOMENT COEFFICIENTS
-CaDL = 0.043 Negative moment coefficient along the shorter dimension due to dead load
-CaLL = 0.043 Negative moment coefficient along the shorter dimension due to live load
-CbDL = 0.052 Negative moment coefficient along the longer dimension due to dead load
-CbLL = 0.052 Negative moment coefficient along the longer dimension due to live load
+CaDL = 0.025 Positive moment coefficient along the shorter dimension due to dead load
+CaLL = 0.035 Positive moment coefficient along the shorter dimension due to live load
+CbDL = 0.019 Positive moment coefficient along the longer dimension due to dead load
+CbLL = 0.024 Positive moment coefficient along the longer dimension due to live load

LOCATION EQUATIONS MOMENT MTOTAL rreqd Ductility rused Spacing suse Rebar spacing, mm
-CaDLWuDLLa2 6.70
Negative Moment, Ma 10.99 0.0057 ok 0.0057 270 270 12 mm diameter @ 250 mm
-CaLLWuLLLa2 4.29
-C W L 2 10.03
Negative Moment, Mb bDL uDL b2 16.46 0.0087 ok 0.0087 175 175 12 mm diameter @ 150 mm
-CbLLWuLLLb 6.43
+CaDLWuDLLa2 3.89
Positive Moment, Ma 7.39 0.0037 ok 0.0037 408 300 12 mm diameter @ 300 mm
+CaLLWuLLLa2 3.50
+CbDLWuDLLb2 3.66
Positive Moment, Mb 6.63 0.0033 ok 0.0034 452 300 12 mm diameter @ 300 mm
+CbLLWuLLLb2 2.97

SLAB DIMENSIONS
L SLAB REACTIONS
300 mm - 12 mm diameter WaDL = 0.5CaDLWDLLa
= 5.472 kN/m
150 mm - 12 mm diameter WaLL = 0.5CaLLWLLLa
= 2.632 kN/m

300 mm - 12 mm diameter WbDL = 0.5CbDLWDLLb


= 8.071 kN/m
250 mm - 12 mm diameter WbLL = 0.5CbLLWLLLb
B
= 3.882 kN/m