2. Service conductors between the street main and the first of connection to the service entrance run underground is known
as the service _______.
a. drop b. loop c. lateral d. cable
3. EMT installed in a wet location, shall have its coupling and connectors _______.
a. protected against corrosion c. raintight type
b. corrosion resistant d. none of these
4. Dual – voltage motors that have different locked – rotor kva per horsepower on the two voltages shall be marked with the
code letter for the voltage giving the _____ locked – rotor kva per horsepower.
a. Highest b. average c. lowest d. normal
6. Outdoor electrical installations over 600 volts that are open to unqualified persons shall comply with _____.
a. Chapter 9 b. Article 225 c. Chapter 7 d. Article 110
9. Receptacles installed on _____ ampere branch circuits, shall be of the grounding type.
a. 15 and 20 b. 25 c. 30 d. 40
10. Class I locations are those that are hazardous because of ______.
a. the presence of combustible dust
b. over 8’ depth of water
c. flammable gases or vapors are or may be present in the air
d. the presence of easily ignitable fibers or flyings
11. Which of the following about the equipment grounding conductor is/ are true?
I. Does not count as a current – carrying conductor
II. Bare, covered or insulated shall be permitted
III. Count one for each grounding conductor in conduit fill
a. I only b. II and III only c. I and III only d. I, II and III
12. When a controller is not within sight from the motor location, the disconnect shall be capable of being _____ in the open
position.
a. down b. up c. locked d. shut – off
13. A green wire with yellow stripes used in a branch – circuit would be the ______ conductor.
a. grounded b. grounding c. neutral d. ungrounded
14. In a dwelling, a 20 ampere rated living room branch circuit can be loaded to a maximum of _____ amperes.
a. 10 b. 15 c. 16 d. 20
HABILIS EE TRAINING CENTER, INC.
61st Isabel Ramiro Road, Purok 6A, Tambo-Hinaplanon,
Iligan City, 9200 Tel No. (063) 2250809 Refresher Day 7
16. Where the number of current – carrying conductor in a raceway is seven, the individual ampacity of each conductor shall
be reduced ______.
a. To 70% due to the number of conductors
b. To 80% if they are continuous loads
c. To both (a) and (b) if the conditions exist
d. Neither apply if the ambient temperature is below 30°C or 86°F
17. Insulated bushings are required on conduit entering boxes, gutters, etc. if the conduit contains conductors as large as
_____.
a. 30 sq mm b. 22 sq mm c. 14 sq mm d. 38 sq mm
18. Plug - in - type over current protection devices or plug - in - type main lug assemblies that are _____ shall be secured in
place by an additional fastener that requires other than pull to release the device from the mounting means on the panel.
a. Three – phase only b. 480v c. back fed d. none of these
20. Which of the following is the maximum allowable rating of a permanently connected appliance where the branch circuit
over current device is used as appliance disconnecting means?
a. 1/8 hp b. ¼ hp c. ½ hp d. 1 hp
21. When connections are made in the white wire in a multiwire circuit ate receptacles, they are considered to be made
_______.
a. Connected to the silver terminal on the duplex
b. To the brass colored terminal
c. With a pigtail to the silver terminal
d. None of these
24. The frame of a clothes dryers shall be permitted to be grounded to the grounded circuit conductor if ______.
I. The grounded conductor is insulated
II. The grounded conductor is not smaller than #10 copper
III. The supply circuit is 120/240v single – phase
a. I only b. II only c. III only d. I, II and III
25. A 20 ampere rated branch circuit serves four receptacles. The rating of the receptacles must not be less than _____
amperes.
a. 20 b. 15 c. 25 d. none of these
HABILIS EE TRAINING CENTER, INC.
61st Isabel Ramiro Road, Purok 6A, Tambo-Hinaplanon,
Iligan City, 9200 Tel No. (063) 2250809 Refresher Day 7
26. The ampacity of a feeder conductor supplying two or more 2 – wire branch circuits shall not be less than _____ amps.
a. 20 b. 25 c. 30 d. 40
27. Where the calculated number of conductors, all of the same size, includes a decimal fraction, the next higher whole
number shall be used if _____.
a. .5 and larger b. .6 and larger c. .7 and larger d. .8 and larger
29. Type SE service – entrance cables shall be permitted in interior wiring systems where all of the circuit conductors of the
cable are of the ______ type.
I. Rubber – covered II. thermoplastic III. metal
a. I and II only b. II only c. II and III only d. I,II and III
30. Elevator traveling cables for operating _____ circuits shall contain nonmetallic fillers as necessary to maintain
concentricity
I. Signal II. control
a. I only b. II only c. both I and II d. neither I nor II
31. Where devices containing a disconnecting means are mounted out of reach, suitable means shall be provided to operate
the disconnecting means from the floor. Which of the following is permitted?
a. Devices cannot be mounted out of reach
b. Ladders
c. Sticks
d. No method is permitted
32. Ground – fault circuit – interrupters shall be installed in the branch circuit supplying underwater pool lighting fixture
operating at more than ______ volts.
a. 12 b. 15 c. 24 d. 50
33. Each transformer shall be provided with a nameplate giving the name of the manufacturer; rated kv; frequency; primary
and secondary voltage; impedance of transformers _____ kva and larger.
a. 112 ½ b. 25 c. 33 d. 50
34. _____ is defined as properly localizing a fault condition to restrict outages to the equipment affected, accomplished by
choice of selective fault protective devices.
a. Monitoring b. Coordinating c. Choice selection d. Fault device
35. Two – wire DC circuits and AC circuits of two or more ungrounded conductors shall be permitted to be tapped from the
ungrounded conductors of circuits having ______.
a. A properly sized tap conductor
b. Less than 50 volts
c. A balance neutral system
d. A grounded neutral conductor
36. Application of demand factors to small appliance and laundry loads in dwelling are permitted in Table ______.
a. 220 – 3 b. 220 – 11 c. 220 – 11 d. 220 – 20
38. FCC cable can have individual branch circuits with a rating not exceeding ____ amperes.
a. 15 b. 20 c. 25 d. 30
39. Auxiliary equipment for electric – discharge lamps shall be _____and treated as sources of heat.
a. Enclosed in noncombustible cases
HABILIS EE TRAINING CENTER, INC.
61st Isabel Ramiro Road, Purok 6A, Tambo-Hinaplanon,
Iligan City, 9200 Tel No. (063) 2250809 Refresher Day 7
b. Thermally protected
c. Weatherproof
d. Ventilated
40. A receptacle outlet installed outdoors shall be located so that ____ is likely to touch the outlet cover or plate.
a. Persons b. water accumulation c. metal d. none of these
41. The feeder conductor ampacity shall not be lower than that of the service – entrance conductors where the feeder
conductors carry the total load supplied by service – entrance conductors with an ampacity of ______ amperes or less
a. 50 b. 55 c. 100 d. 125
42. To qualify as a lighting and appliance branch circuit panelboard the number of circuits rated 30 amperes or less with
neutrals must be _____.
a. More than 10% b. 42 or less c. 24 or less d. 10%
43. Metal enclosures used to protect ______from physical damage shall not be required to be grounded.
a. Service conductors b. feeders c. cable assemblies d. none of these
44. Connection devices or fittings must not connecting grounding conductors to equipment by means of ______.
a. Pressure connections b. solder c. lugs d. approved clamps
45. Which of the following is not a standard classification for a branch circuit supplying several loads?
a. 20 amp b. 25 amp c. 30 amp d. 50amp
47. Finished ceilings heating cables shall be permitted to covered with _____.
I. Wallpaper II. plastic III. paint IV. wood
48. Metal – enclosed busways shall be installed so that _____ from induced circulating currents in any adjacent metallic parts
will not hazardous to personnel or constitute a fire hazard.
a. Stray currents b. magnetic flux c. the impedance d. temperature rise
49. AC – DC general use snap switches may be used for control of inductive loads not exceeding ______ of the rating at the
voltage.
a. 50% b. 80% c. 100% d. 70%
50. No point along the floor line in any useable wall space in a swelling may be more than ____ feet from the outlet.
a. 6 b. 6 ½ c. 8 d. 10