You are on page 1of 1

Proyek 

6 Ruas Toll Paket 1A, Ruas Kelapa Gading ‐ Pulogebang
Jakarta
Checking Maximum Stress on Span Jack and Stabilizer Jack
A. Check of Maximum Stress Span Jack 260T
1. Span Data
Span  : 50m (PS‐PS)
Berat Span : 597 T
Berat Pier Segment : 80 T (Estimasi)
2. Pembebanan
Asumsi PS‐A memikul 1/2 W span PN‐1 + 1/2 W span PN

A B

Beban at PS‐A = 677 T
Qty span jack on pier PS = 4 nos Capacity: 260 T
P per span jack 260T = 169,3 T < 260T  Ok!
3. fc' concrete = 40 Mpa
SLS on span jack (1,4P) = 236,95 T
Minimum Stress Area = 59237,5 mm2
Dimension of bearing area = 243,387551 mm
4. Shim plate on Span Jack  = 400
Area shim plate = 160000 mm2
Max Stress occurred = 14,8 Mpa < 0,4 Fc' 16 Mpa OK!

(BS 5400 Clause 4.2.3)
B Check of Maximum Stress Stabilizer Jack
1. Weight of Segment (Pier Segment as assumed)
PS Weight = 80 T
SLS (1,4 Wps) = 112 T
2 fc' concrete = 40 Mpa
Minimum Stress Area = 28000 mm2
Dimension of bearing area = 167,3 mm
3 Shim plate on stabilizer jack = 300 mm
shim plate area = 90000 mm2
Max stress occurred = 12,4 Mpa < 0,4 Fc' 16 Mpa OK!