You are on page 1of 7

29-Nov-2019 20:58 HolcimHeat ThermoCal v.2.0.

0 Page 1 of 7

HolcimHeat ThermoCal Report

Summary Table

Mix PCW Old EXTRA PCW New EXTRA Access Tokyo PPC Tokyo low heat Tokyo ppc old
ID Y19 W Y19 W Y19 W
Tmax 34.2 32.7 35.5 30.8 32.1
°C
Time@Tmax 14:08 12:04 11:42 10:45 18:20
hh:mm
Init Set 05:26 04:16 04:46 05:17 06:32
hh:mm
Final Set 07:22 05:56 06:34 06:49 08:38
hh:mm
CT@6 -14.0 -13.0 -9.0 -15.0 -16.0
°C*hrs
CT@12 3.0 6.0 20.0 -6.0 -13.0
°C*hrs
CT@18 36.0 30.0 52.0 1.0 8.0
°C*hrs
CT@24 51.0 39.0 60.0 -4.0 24.0
°C*hrs
29-Nov-2019 20:58 HolcimHeat ThermoCal v.2.0.0 Page 2 of 7

Temperature Graphs
29-Nov-2019 20:58 HolcimHeat ThermoCal v.2.0.0 Page 3 of 7

Sample 1

Filename TCLog_2019-11-25_15-09_A3_PCW Old EXTRA Y19 W.txt


Logger 1 SN AQ866/495
Logger 2 SN
Sample Channel A3
Start Date, Time 25-Nov-2019, 15:09
Stop Date, Time 26-Nov-2019, 15:08

Department Name I & A Centre


Line Frequency 50 Hz
Thermocouple Type K

Mix ID PCW Old EXTRA Y19 W


Mix Date, Time 25-Nov-2019, 14:55
Mix Type mortar
Technician Danidu
Sample Mass 1300.0 g
Water/Cement Ratio 0.50
Sand/Mortar Ratio 0.96
Reference Cell A1
Additional Info 1 Fingerprint for Mannar Project
Additional Info 2 Access RMX
Additional Info 3 QAE Adhikari
Additional Info 4

1-Day Comp Strength 0.0 MPa


Baseline Temperature 28.0 °C
29-Nov-2019 20:58 HolcimHeat ThermoCal v.2.0.0 Page 4 of 7

Sample 2

Filename TCLog_2019-11-25_15-25_A5_PCW New EXTRA Y19 W.txt


Logger 1 SN AQ866/495
Logger 2 SN
Sample Channel A5
Start Date, Time 25-Nov-2019, 15:25
Stop Date, Time 26-Nov-2019, 15:24

Department Name I & A Centre


Line Frequency 50 Hz
Thermocouple Type K

Mix ID PCW New EXTRA Y19 W


Mix Date, Time 25-Nov-2019, 15:13
Mix Type mortar
Technician Danidu
Sample Mass 1300.0 g
Water/Cement Ratio 0.50
Sand/Mortar Ratio 0.96
Reference Cell A1
Additional Info 1 Fingerprint for Mannar Project
Additional Info 2 Access RMX
Additional Info 3 QAE Adhikari
Additional Info 4

1-Day Comp Strength 0.0 MPa


Baseline Temperature 28.0 °C
29-Nov-2019 20:58 HolcimHeat ThermoCal v.2.0.0 Page 5 of 7

Sample 3

Filename TCLog_2019-11-25_15-44_A7_Access Tokyo PPC Y19 W.txt


Logger 1 SN AQ866/495
Logger 2 SN
Sample Channel A7
Start Date, Time 25-Nov-2019, 15:44
Stop Date, Time 26-Nov-2019, 15:43

Department Name I & A Centre


Line Frequency 50 Hz
Thermocouple Type K

Mix ID Access Tokyo PPC Y19 W


Mix Date, Time 25-Nov-2019, 15:31
Mix Type mortar
Technician Danidu
Sample Mass 1300.0 g
Water/Cement Ratio 0.50
Sand/Mortar Ratio 0.00
Reference Cell A1
Additional Info 1 Fingerprint for Mannar Project
Additional Info 2 Access RMX
Additional Info 3 QAE Adhikari
Additional Info 4

1-Day Comp Strength 0.0 MPa


Baseline Temperature 28.0 °C
29-Nov-2019 20:58 HolcimHeat ThermoCal v.2.0.0 Page 6 of 7

Sample 4

Filename TCLog_2019-11-28_20-45_A5_Tokyo low heat.txt


Logger 1 SN AQ866/495
Logger 2 SN
Sample Channel A5
Start Date, Time 28-Nov-2019, 20:45
Stop Date, Time 29-Nov-2019, 20:51

Department Name I & A Centre


Line Frequency 50 Hz
Thermocouple Type K

Mix ID Tokyo low heat


Mix Date, Time 28-Nov-2019, 20:08
Mix Type mortar
Technician Adhi
Sample Mass 1300.0 g
Water/Cement Ratio 0.50
Sand/Mortar Ratio 0.67
Reference Cell A1
Additional Info 1 Mannar project
Additional Info 2
Additional Info 3
Additional Info 4

1-Day Comp Strength 0.0 MPa


Baseline Temperature 28.0 °C
29-Nov-2019 20:58 HolcimHeat ThermoCal v.2.0.0 Page 7 of 7

Sample 5

Filename TCLog_2019-11-28_20-46_A7_Tokyo ppc old.txt


Logger 1 SN AQ866/495
Logger 2 SN
Sample Channel A7
Start Date, Time 28-Nov-2019, 20:46
Stop Date, Time 29-Nov-2019, 20:51

Department Name I & A Centre


Line Frequency 50 Hz
Thermocouple Type K

Mix ID Tokyo ppc old


Mix Date, Time 28-Nov-2019, 20:28
Mix Type mortar
Technician Adhi
Sample Mass 1300.0 g
Water/Cement Ratio 0.50
Sand/Mortar Ratio 0.67
Reference Cell A1
Additional Info 1 Mannar project
Additional Info 2
Additional Info 3
Additional Info 4

1-Day Comp Strength 0.0 MPa


Baseline Temperature 28.0 °C

DISCLAIMER: ThermoCal results are only applicable to the samples tested. ThermoCal results are only indicative of
concrete performance. Actual concrete tests according to relevant standards and practices are required to validate
any results generated by ThermoCal. ThermoCal results do not guarantee any concrete performance whatsoever.