You are on page 1of 1

ANALYSIS AND DESIGN OF REINFORCED CONCRETE CORBEL

ASpectrum Designs Plus Engineering Services Project Title: Proposed Two Store Residential Building
Address: 8487 Sandoval Avenue, Pinagbuhatan, Pasig City 1602 Project Location: Villa Cuana Phase 1, Pinagbuhata, Pasig City 1602
Contact: 09982028893 Structural Engineer: Engr. Andro S Rebuyas, RCE, ME-1, RMP, M.Eng-SE
Gmail add: asrebuyas.wvc@gmail.com Membership: M.PICE, M.ASCE, M.PAMEA, M.FPEA, M.PSUMP, M.NAMPAP, M.SEAD

INPUT DATA

MATERIAL PROPERTIES CORBEL GEOMETRY

fy = 415.00  Mpa Yield strength of reinforcement bw = 302 mm Width of Corbel


f'c = 35.00 Mpa Compressive strength of concrete h= 505 mm Total Thickness of Corbel
Cv = 55 mm Cover of Corbel
COEFFICIENT OF CONCRETE, λ Loc = 401 mm Length of Corbel
bc = 395 mm Width of Column
λ Concrete d= 450 mm Depth to main reinforcement
1.00 Normal weight concrete
0.85 Sand light weight concrete DESIGN LOAD DATA
0.75 All light weight concrete
Vu = 380 kN Factored vertical load
λ = 1.00 Normal weight concrete a= 200 mm Distance from face to column
Nu = 80 kN Horizontal force
COEFFICIENT OF FRICTION, μ ϕ= 0.75 Strength reduction factor

μc Application Method CHECK


1.4λ Concrete cast monolithic
1.0λ Concrete placed against roughened hardened concrete 0.44 a/d ≤ 1
0.6λ Concrete placed against unroughened hardened concrete 0.95 0.2 Vu/Nu ≤ 1
0.7λ Concrete anchored to structural steel 0.53 Vn/(0.2 fc' b d) ≤ 1
0.67 Vn/(5.55b d) ≤ 1
μc= 1.4λ μc 0.99 Asc/Asel ≤ 1
0.72 Ah/Ah_sel ≤ 1
μ= 1.40 Coefficient friction

CORBEL DIAGRAM

380
20
0 80
5
5

50
h

5
45
0

39 401
5
Elevation
bw
30
2

Section

DETAILED CALCULATION

Find factored shear Vu and tensile force Nuc Reinforcement to carry tensile force (ACI 11.9.3.4)

Nuc min = 76.00 kN Nuc_min     = 0.2 x Vu An = 257.03 mm2 An = Nuc / ϕfy
Nuc act = 80.00 kN Nuc_act
Required main flexural steel (Asc) is given by (ACI 11.9.3.5 and 11.9.5)
Compute nominal value of shear and tensile force
932.36 mm2 Af + An 
Vn = 506.67 kN Vn   = Vu / 0.75 838.40 mm2 2Avf/3 + An 
Nnc = 106.67 kN Nnc  = Nuc / 0.75 Asc = 932.36 mm2 Asc 
Ascsc = 942.48 mm2 Asc_sc
Check section Asc prov = 942.48 mm2 Asc_prov 

951.30 kN 0.2 x fc’x b x d  ( kN) > Vn Provide closed horizontal stirrups (ACI 11.9.4)
747.45 kN 5.5 x b x d    ( kN) > Vn
Ah = 337.66 2
            
mm Ah = 0.5 (Asc – An)
Compute shear-friction reinforcement (ACI 11.7.4.1) Ahsc = 471.24 mm2 Ah_sc
Ahprov = 471.24 mm2 Ah_prov
Avf = 872.06 mm2 Avf = Vn /μ fy Sh = 100 mm Sh 

Calculate required flexural reinforcement (11.9.3.3)

Mu = 80400000 Mu = Vu av + Nuc (h – d)


Af = 675.33 mm2 Af = Mu / ϕ fy (0.85d)

CORBEL DESIGN SUMMARY

REINFORCEMENT DESIGN CORBEL DIMENSION


380
#= 1 pcs Number of Rebars 200
Φ= Φ20 mm Diameter of Rebars 80
As = 314.2 mm2 Area of Rebar
55

L= 2574.0 mm
505
h
450

#= 2 pcs Number of Rebars


Φ= Φ20 mm Diameter of Rebars
As = 628.3 mm 2
Area of Rebar
L= 2486.0 mm

#= 3 pcs Number of Rebars 395 401


Φ= Φ10 mm Diameter of Rebars
As = 471.2 mm2 Area of Rebar Elevation
Sh = 100.0 mm
L= 2136.0 mm
302
bw

Section

This Spreadsheets is licensed only to Engr. Andro S. Rebuyas, RCE, ME-1, RMP, M.Eng-SE