TLOCRT PODRUMA - IZVEDBENI PROJEKT

STR 25

- PRILIKOM IZRADE PALIRSKIH NACRTA PODRUMA, KROVIŠTA I KARAKTERISTIČNOG PRESJEKA U SKLOPU PREDMETA ELEMENTI

ZGRADA 2, OBAVEZNO JE NA VJEŽBAMA IMATI FOTOKOPIJU TLOCRTA PRIZEMLJA M 1:50 IZRAĐENU U SKLOPU PREDMETA

ELEMENTI ZGRADA 1

1 POZICIONIRANJE CRTEŽA NA PAPIRU


- NACRT SE RIŠE NA PAPIRU FORMATA A3, A CRTEŽ NA PAPIRU POSTAVLJAMO NA ISTI NAČIN KAKO JE POSTAVLJEN

TLOCRT PRIZEMLJA.

- TLOCRT PODRUMA CRTAMO U MJERILU 1:50 ŠTO ZNAČI DA JE JEDAN cm NA PAPIRU JEDNAK 50 cm U PRIRODI

2 SASTAVNICA
- SE NALAZI U DONJEM DESNOM UGLU PAPIRA

9 cm

1 cm 6 cm 2 cm
0,5 0,5

TLOCRT PODRUMA IZVEDBENI PROJEKT


1 cm

EZ IME I PREZIME (VAŠE)


M 1:50

3 ZIDOVI
- PODRUMSKI ZIDOVI SU LIJEVANI, NEARMIRANI, BETONSKI ZIDOVI DEBLJINE: 40 cm UKOLIKO SU U PRIZEMLJU DEBLJINE 38 cm

35 cm UKOLIKO SU U PRIZEMLJU DEBLJINE 30 cm

- BETONSKI ZIDOVI OZNAČAVAJU SE, U TLOCRTU I POGLEDU, ŠRAFIRANJEM TANKOM LINIJOM POD KUTEM OD 45 STUPNJEVA

- ZIDOVI SE ZADEBLJAVAJU PREMA UNUTRAŠNJEM PROSTORU, ŠTO ZNAČI DA VANJSKA DIMENZIJA GABARITA ZGRADE

OSTAJE ISTA KAO U PRIZEMLJU, DOK JE DIMENZIJA UNUTRAŠNJEG PROSTORA PODRUMA NEŠTO MANJA.

- PODRUM OBJEKTA NALAZI SE SAMO ISPOD ZGRADE, ISPOD TERASE

OPEKA I ULAZNOG PODESTA, U TLOCRTU PODRUMA, VIDLJIVI SU TEMELJI.

- TEMELJE U TLOCRTU PODRUMA NE ŠRAFIRAMO


ARMIRANI BETON
- RAZLOG TOME JE ŠTO SE TEMELJI U OVOM SLUČAJU NALAZE

IZNAD RAVNINE PRESJEKA KROZ ZGRADU, KAO I DA JE JASNO VIDLJIVA

BETON RAZLIKA IZMEĐU NOSIVOG ZIDA I TEMELJA.

PRIMJER POVEĆANJA DEBLJINE ZIDA U PODRUMU

NA DETALJU PREVALJENOG PRESJEKA


TLOCRT PODRUMA - IZVEDBENI PROJEKT

STR 26

- PREGRADNI ZIDOVI PODRUMA IZVODE SE IZ OPEKE I DEBLJINE SU 12 cm.

- POPREČNI PREGRADNI ZIDOVI MORAJU SE NALAZITI TOČNO ISPOD POPREČNIH PEGRADNIH ZIDOVA PRIZEMLJA

3 TLOCRTNA DISPOZICIJA PROSTORA

1 3

100
60 60

100

1/2 1/2
1/2 1/2

2 4

1/2 1/2 kuh.


1/2 1/2
TLOCRT PODRUMA - IZVEDBENI PROJEKT

STR 27

4 SERKLAŽI I DIMOVODNI KANALI


- POZICIJE VERTIKALNIH SERKLAŽA I DIMOVODNIH KANALA IDENTIČNE SU ONIMA U PRIZEMLJU

- SERKLAŽI SE U PODRUMU RIŠU BEZ TERMOIZOLACIJE

- DIMOVODNI KANALI SU ZIDANI ŠTO TREBA BITI VIDLJIVO U NACRTU

DK U ZIDU DEBLJINE 40 cm DK U ZIDU DEBLJINE 35 cm

12 14 12 14 12 14 12 14 12 12 14 12 14 12 14 12 14 12
14 14 12

12 14 12
35
40

38
3

5 VRATA I PROZORI
- PROZORI SE POSTAVLJAJU NA ISTE POZICIJE NA KOJIMA SE NALAZE U PRIZEMLJU, ILI PREMA DISPOZICIJI PROSTORA

VIDI Br. 3, UKUPNO 2-3 PROZORA. PROZORI SU BEZ ROLETA SA POLUPROVIDNIM STAKLOM.

- SVIJETLA ŠIRINA PROZORA JE 70 cm ILI 120 cm ZIDARSKA ŠIRINA PROZORA JE 90 cm ODNOSNO 140 cm

- SVIJETLA VISINA PROZORA JE 60 cm, A ZIDARSKA VISINA PROZORA JE 80 cm

- PROZORI SU IZVANA POLUUKOPANI, DOK SU IZNUTRA SA VISOKIM PARAPETOM. TO ZNAČI DA IM JE GORNJI BRID

PRISLONJEN UZ HORIZONTALNI SERKLAŽ. VISINU PARAPETA POTREBNO JE IZRAČUNATI

OKVIRNA VISINA PARAPETA IZNOSI: ZA PREDLOŠKE 1 i 3 cca 160 cm

ZA PREDLOŠKE 2 i 4 cca 140 cm

- SVA VRATA U PODRUMU SVIJETLE SU ŠIRINE 80 cm ODNOSNO 90cm ZIDARSKE ŠIRINE

6 VISINA PROSTORA I STUBA


- DUBINA PODRUMA NA KOTI GOTOVOG PODA JE : ZA PREDLOŠKE 1 i 3 2,80 m

ZA PREDLOŠKE 2 i 4 2,60 m

- STUBIŠTE SE NALAZI NA ISTOJ POZICIJI KAO U PRIZEMLJU A DIMENZIJE STUBA SU:

ZA PREDLOŠKE 1 i 3 13 ŠIRINA PO 25 cm ODNOSNO 14 VISINA PO 20 cm - U DVA KRAKA I TO 8V + 6V

ZA PREDLOŠKE 2 i 4 12 ŠIRINA PO 25 cm ODNOSNO 13 VISINA PO 20 cm

- KOD CRTANJA STUBIŠTA KONZULTIRATI SKRIPTA STR 5. EZ 1


TLOCRT PODRUMA - IZVEDBENI PROJEKT

STR 28

7 PODZIDANO STUBIŠTE
- JE SISTEM IZVEDBE STUBIŠTA KOJI SE DANAS VIŠE NE IZVODI. U PROJEKTU JE ZADAN U SVRHU VJEŽBANJA PERCEPCIJE

I PRIKAZIVANJA KOMPLEKSNIH SITUACIJA U NACRTIMA.

- RADI SE O STUBIŠTU KOJE JE NASTUPNIM PLOHAMA OSLONJENO NA BOČNE ZIDOVE IZ OPEKE, KOJI GA

PRIDRŽAVAJU ILI U CIJELOSTI NOSE.

- U TLOCRTU I PRESJEKU PRIKAZANA JE SHEMA ZIDOVA I PODZIDOVA.

KAKO U TLOCRTNOM PRIKAZU PRIKAZUJEMO ZGRADU PRESJEČENU ZAMIŠLJENOM RAVNINOM KOJA SE NALAZI

NA VISINI 100 cm OD PODA, TAKO SREDIŠNJU PREGRADU VIDIMO KAO ZID DEBLJINE 36 cm.

CRTKANOM LINIJOM OZNAČENA JE RAZLIKA U VISINI ZIDOVA, TE ODVAJANJE SREDIŠNJEG PREGRADNOG ZIDA

OD BOČNIH PODZIDOVA U VIŠIM SLOJEVIMA PREGRADE.

- NA PRIKAZU "POGLED X" OSJENČANO SU PRIKAZANI ZIDOVI, DOK SU NEOSJENČANI PODZIDOVI

TLOCRT POGLED X - SAMO ZIDOVI, BEZ STUBA

P P

PRESJEK P X
TLOCRT PODRUMA - IZVEDBENI PROJEKT

STR 29

8 ULAZNI PODEST
- U TLOCRTU PODRUMA VIDLJIVI SU TEMELJI ULAZNOG PODESTA

- TEREN OKO ZGRADE NALAZI SE NA KOTI -0,45 m ILI -0,60 m U ODNOSU NA POD PRIZEMLJA Tj. KOTU + 0,00

NA PODEST SE STOGA USPINJEMO PO STUBAMA VISINE 3 X 15 cm ILI 4 X 15 cm, DOK JE ŠIRINA STUBE 30 cm.

- TEMELJE ULAZNOG PODESTA CRTAMO KAO PRSTEN PO UBODU PODESTA I STUBA, DEBLJINE 30 cm, S TIM DA JE

PRSTEN OTVOREN PREMA ZGRADI, TE DA POSTOJI DILATACIJSKI PROSTOR IZMEĐU TEMELJA PODESTA

I ZIDA ZGRADE ŠIRINE cca 3-5 cm.

- NA TLOCRTU TEMELJA UCRTAVAMO PREVALJENE PRESJEKE SA SVE ČETIRI STRANE, NA KOJIMA MORAJU

BITI VIDLJIVE STUBE I OSLANJANJE PLOČE PODESTA NA TEMELJE, KAO I VISINSKE KOTE.

- TEMELJE U PREVALJENIM PRESJECIMA PRIKAZUJEMO U PRIKRATI (NIJE NACRTANA STVARNA VISINA TEMELJA I TEMELJNOG ZIDA)

A DONJI BRID TEMELJA DEFINIRAMO VISINSKOM KOTOM.

- MINIMALNA DUBINA TEMELJA U ZONI U KOJOJ ŽIVIMO JE 80 cm ISPOD POVRŠINE ZEMLJE (UKOLIKO SE RADI O NORMALNOM,

ČVRSTOM TLU). S OBZIROM NA NAVEDENI PODATAK, DUBINE TEMELJA ULAZNOG PODESTA BITI ĆE:

ZAŠTITA OD VODE 0,05 m + STUBE 0,45 m + DUBINA TEMELJENJA 0,80 m = - 1,30 m

ZAŠTITA OD VODE 0,05 m + STUBE 0,60 m + DUBINA TEMELJENJA 0,80 m = - 1,45 m

TLOCRT POGLED

TLOCRT TEMELJA

TLOCRT TEMELJA PRESJEK SA PREVALJENIM PRESJECIMA PRIKRATA


- 0,05

- 0,05

- 1,30
- 1,30

5 cm DILATACIJA
TLOCRT PODRUMA - IZVEDBENI PROJEKT

STR 30

9 PREVALJENI PRESJECI
- PREVALJENE PRESJEKE POTREBNO JE PRIKAZATI NA ISTIM MJESTIMA KAO U PRIZEMLJU, I UGLAVNOM SU ISTI.

U PODRUMU NE POSTOJE PREVALJENI PRESJECI SA KUTIJOM ZA ROLETU, A NOVI SU PRESJECI DANI PRIMJEROM U NASTAVKU.

- NA PREVALJENIM PRESJECIMA MORA BITI VIDLJIVA RAZLIKA MATERIJALA OPEKA - BETON.


20
30
10

30

20

UZLAZNI KRAK PRIZEMLJE - KAT OBODNA GREDA JEDNOKRAKOG STUBIŠTA

10
NEMA SUSJEDA

20

40
30

SPOJ PLOČE I VANJSKOG NOSIVOG ZIDA KRAJ DOLAZNOG KRAKA IZ PODRUMA

(SAMO ZA DVOKRAKO STUBIŠTE)

+ 0,10
- 0,10
KULIR PLOČE 4 cm
- 0,10
PIJESAK 5 cm

PE FOLIJA

BET. PODLOGA 10 cm

ŠLJUNAK 15 cm

NABIJENA ZEMLJA

- 1,30 - 1,30

OBOD TERASE SA OGRADOM OBOD TERASE BEZ OGRADE