Professional Documents
Culture Documents
Cal 2
Cal 2
Total Building Surface Area = 28,242 300 Total Opening Area = 300
Results 1
1
Clauses Ao>1.1Aoi Ao>4 or 0.01 Ag Aoi/Agi<0.2 Building 1
Area 1 = NO NO OK Enclosed 1
Area 2 = NO NO OK Enclosed 1
Area 3 = NO OK OK Enclosed 1
Area 4 = NO OK OK Enclosed
Area 5 = NO NO OK Enclosed
Area 6 = NO NO OK Enclosed
1 3/16/2021 11:39 PM
INPUT &
OUTPUT SHEET
Input Data:
Wind
B
Load Data:
Roof Dead Load:
Purlin Load = 1 Psf L= 168.00
Roof Sheeting = 1 Psf
Plan
Collateral Load = 4.3 Psf
Accessories = 1 Psf
Roof Live Load:
Area = 2,205 Sft
Roof Live Load = 12 12 PSF :-MBMA-2006
2 3/16/2021 11:39 PM
Main Frame Design Loads:
First Second
Conditions: h <= 60' h <= Min(L,B)
Yes, O.K. Yes, O.K.
I
II If h < 15 then: Kh = 2.01*(15/zg)^(2/a) (Table 6-3, Case 1b)
III If h >= 15 then: Kh = 2.01*(z/zg)^(2/a) (Table 6-3, Case 1b) (Note: z not < 30' for Exp. B, Case 1)
IV a= 7.00 (Table 6-2)
B zg = 1200 (Table 6-2)
C Kh = 0.70 (Kh = Kz evaluated at z = h)
D I= 1.00 (Table 6-1) (Importance factor)
Gable Velocity Pressure: qz = 0.00256*Kz*Kzt*Kd*V^2*I (Sect. 6.5.10, Eq. 6-15)
Monoslope qh = 11.01 psf qh = 0.00256*Kh*Kzt*Kd*V^2*I (qz evaluated at z = h)
Y
N qh = 11.01 Psf
Part. Closed
Closed Load Transverse Dir. PLF (For Staad)
Open Internal Frame
Wind Load Roof Dead Roof Live Floor Dead Floor Live
Surface Co-efficients Loads (PLF) Load Load MB MB
(w/ +GCpi) (w/ -GCpi) (w/ +GCpi) (w/ -GCpi) Plf Plf Plf Plf
Zone 1 0.23 0.59 61 158 -1838 -2450
Zone 2 -0.87 -0.51 235 138 0 0
Zone 3 -0.56 -0.20 150 53 0 0
Zone 4 -0.48 -0.12 129 31 -179 -294 0 0
Zone 5 -0.63 -0.27 170 73 0 0
Zone 6 -0.63 -0.27 170 73
Status 45.00 ft Half of Building
End Wall
Zone 1E 0.44 0.80 73 121 -919 -1225
Zone 2E -1.25 -0.89 193 144 0 0
Zone 3E -0.72 -0.36 107 59 -89 -147 0 0
Zone 4E -0.62 -0.26 93 44 0 0
Status 61.25 ft Use 45 0 0
a= 9.0 ft
Total Horizontal Force = 3668 Lbs X- Dir.
3668 Lbs Opposite
Joist Loads
3 3/16/2021 11:39 PM
As a Wall Member
Internal Girts Contributory Area
a. The Average of Two Adjacent Tributory Widths 4.50 0.00 2.25 ft
b. Span (Bay Spacing) divided by 3 24.50 3.00 8.17 ft
Inward Pressure
All Zones = 21.64 Plf
4 3/16/2021 11:39 PM
Girts (Wall Components) Design Loads:
5 3/16/2021 11:39 PM
End Wall Column Design Loads:
Zone 4 = Interior
Zone 5 = Corner a= 9.0 ft
Columns
Wind Load Tabulation for Wall Components & Cladding
Corner to z Area qh p = Net Design Load (plf)
Ridge (ft.) Sft (psf) Zone 4 (+) Zone 4 (-) Zone 5 (+) Zone 5 (-)
Corner 24.50 200.08 11.01 72 -80 72 -85
1 26.00 390.00 11.01 137 -152 137 -154
2 27.50 412.50 11.01 136 -151 136 -153
3 29.00 435.00 11.01 135 -150 135 -152
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
6 3/16/2021 11:39 PM
X-Bracings
X-Bracing Data
No. of Wind Column Bays = 6 Nos. Wind Column Spacing = 15.00 ft
Steel Rope Yeild Strength = 50 ksi Length of Cable = 28.8 ft
Dia Of Rope = 12 mm Braced Bays = 3 Nos.
Horizontal Component = 1,487 Lbs
Vertical Reaction = 1,487 Lbs
Forces in Roof Nos. of Ropes Dia of Rope Used
SR.<=1
Lbs Nos. mm
1,487 1 12 0.41
1,234 1 12 0.38
704 1 12 0.28
144 1 12 0.13
0 1 12 0.00
0 1 12 0.00
0 1 12 0.00
0 1 12 0.00
0 1 12 0.00
0 1 12 0.00
0 1 12 0.00
0 1 12 0.00
0 1 12 0.00
0 1 12 0.00
0 1 12 0.00
0 1 12 0.00
7 3/16/2021 11:39 PM
Cranes Data & Load Calculation
Pv1 = - - Lbs
Pv2 = - - Lbs
8 3/16/2021 11:39 PM