You are on page 1of 1

ANALYSIS WIND LOAD [ UNIFORM BUILDING CLODE (UBC)] BY เพจวิศวกรจับฉ่าย

ANALYSIS WIND LOAD [ UNIFORM BUILDING CLODE (UBC)]


Project : MASTER PROJECT Purlin No. :
Building: ><" Location :
By : MR. KITTIKUN PHONSUWAN Date : 3 AUGUST 2014

A. Important Factor
Important Factor ( I ) Uniform Building Clode P=C e Cq Qs I
2 Type Building Important Factor
1= Public Buildings 1.5 Important Building ( I ) 1.25
2= Residential more than 300 persor 1.25
3= etc 1
B. Table Ce x Qs
1 2 3 2
3 Hight (m) Location A Location B Location C Location of Building : Location B
1 0-10 140 95 75 Hight Building : 20-40 m.
2 10-20 155 105 75 Ce X Qs : 115 kg/m2
3 20-40 177 115 80 Structure Type : Gable roof
4 40-80 185 135 100 Slope : 36.87 degree
5 80-120 200 160 120 FRONT 1 : Cq 0.8 in
6 120-160 210 175 140 BLACK 2 : Cq 0.5 out
7 160-200 220 190 160 TOP WINDWARD 4 : Cq 0.7 out
8 200-250 230 210 180 TOP LEEWARD 3 : Cq 0.7 out
9 250-300 240 225 200

C. Table Cq
Structure Type Cq A
A Gable roof TOP WINDWARD out
1 Wall windward side 0.8 in 100.63 kg/m2 TOP LEEWARD out
2 Wall leeward side 0.5 out 100.625 kg/m2
3 Roof leeward side or Roof plane 0.7 out
Roof windward side
4 Slope < 9 :12 0.7 out
5 Slope 9 :12 - 12:12 0.4 in FRONT in BLACK out
6 Slope > 12 :12 0.7 out 115 kg/m2 71.88 kg/m2
B Wind Parallel Roof
7 Open Structure 1.2 in
8 Closer Structure 0.7 out

ANALYSIS WIND LOAD [ UNIFORM BUILDING CLODE (UBC)] BY เพจวิศวกรจับฉ่าย