DESIGN CODE: AASHTO LRFD - INDIRECT DESIGN METHOD (CLAUSE 12.10.4.3), AASHTO M 242M/M & AASHTO M 170M-04
A'so
Asi
Q2
Aso A'si
A'so Asi
Reqd. Reinf. In Inner Hoop Asi = 360 mm2/linear mt. Table 3 - Class III Reinforced Pipe
Reqd. Reinf. In Eliptical Hoop Ase = 400 mm2/linear mt. Table 3 - Class III Reinforced Pipe
2
Total C/S area of Longitudinal bars = 804 mm /linear mt. As per Figure-1 of AASHTO M170M-04
2
Required Total C/S Area of Longitudinal Bar's = 245 mm /linear mt. OK
Reqd. Reinf. In Outer Hoop Aso = 620 mm2/linear mt. As per Figure-1 of AASHTO M170M-04
2
Reqd. Reinf. In Inner Hoop Asi = 760 mm /linear mt. As per Figure-1 of AASHTO M170M-04
Proivided Spacing S1 = 75 mm OK
Total No of Hoops = 14
Total No of Hoops = 10