Professional Documents
Culture Documents
DESIGN CODE: AASHTO LRFD - INDIRECT DESIGN METHOD (CLAUSE 12.10.4.3), AASHTO M 242M/M & AASHTO M 170M-04
A'si
A'so
Aso
Q2
Ase
Q1
Indicative Diagram
INPUT
No of cells = 1
Clear Span = 900 mm
2
Grade of Concrete = 30 N/mm Table 3 - Class III Reinforced Pipe
3
Unit Weight of reinforcement = 7850 kg/m
Barrel thickness = 100 mm Table 3 - Class III Reinforced Pipe
Circumferential Reinforcement
Reqd. Reinf. In Outer Hoop Aso = 220 mm2/linear mt. Table 3 - Class III Reinforced Pipe
2
Reqd. Reinf. In Inner Hoop Asi = 360 mm /linear mt. Table 3 - Class III Reinforced Pipe
Reqd. Reinf. In Eliptical Hoop Ase = 400 mm2/linear mt. Table 3 - Class III Reinforced Pipe
Total C/S area of Longitudinal bars = 1608 mm2/linear mt. As per Figure-1 of AASHTO M170M-04
2
Required Total C/S Area of Longitudinal Bar's = 245 mm /linear mt. OK
Total No of Hoops = 10
Maximum Vertical Rise from Center b = 496 mm (Approx., assuming 5mm gap from inner hoop long. bars)
Maximum horizontal dist. from Center a = 504 mm (Approx., assuming 5mm gap from Outer hoop long. bars)
Total No of Hoops = 10