You are on page 1of 3

Design of Column -C1 for confining reinforcement

Data

Pedestal Size 800 mm x 800 mm


Gross area of pedestal A g = 800 x 800 = 640000 mm2
Clear cover to rebar = 75 mm
Details of reinforcement provided
Diameter of bar = 25 mm
No. of bars provided = 20 Nos.
Diameter of ties = 10 mm
Spacing of ties S= 75 mm c/c
Concrete Grade = M-30
Comp. strength fck = 30 N/mm2
Steel Grade Fe 500D
500 N/mm
2
Yield strength ; fy =
Length of column 9650 mm

Area of reinforcement required from STAAD = 8793 mm2


\ Pt Required = 8793 x 100 / 640000 = 1.38 %
\ Pt Provided = ( π /4 x 252 ) x 100 / x 20 x 640000 = 1.54 %
No. of bars on one face = 6 Nos.
No. of bars on second face = 4 Nos.

\ Maximum spacing = (800 - 2 x 75 - 2 x 10 - 25 ) = 121 mm


5
Check for spacing between vertical bars

As per Cl. 7.4.8 of IS 13920 : 1993


The area of cross section, Ash of the bar forming rectangular hoop, to be used as special confining reinforce-
ment shall not be less than

Ash = 0.18S.h.fck /fy [ Ag / Ak - 1.0]


Where;
h = Longer dimension of the rectangular confining hoop measured to its outer face. ≤ 300 mm
Ak = Area of confined concrete core in the rectangular hoop measured to its outside dimensions.
The size of concrete core = 630 mm x 630 mm
Therefore; Ak = 630 x 630 = 396900 mm2
Ash = π /4 x10 ^2 = 78.54 mm2

\h= Ash / [0.18S.fck /fy (Ag / Ak - 1.0)]


h= 78.54 = 158.31 mm
0.18 x 75 x 30 / 500 ( 640000 / 396900 - 1.0 )
> 121 mm Therefore, O.K.
Special confining reinforcement shall be provided over a length L0 from each joint face,
As per Cl. 7.4.1 of IS 13920:1993
Length L0 shall not be less than,
a) large lateral dimension of member = 800 mm
b) 1/6 of clear span of the member = 1/6 x 9650 = 1608.34 mm
c) 450 mm
\ Minimum length of special confining reinforcement is 1608 mm
Provided length of special confining reinforcement is 1800 mm Therefore, O.K.
Design of Column - C1, for confining reinforcement
Data

Pedestal Size 850 mm x 850 mm


Gross area of pedestal A g = 850 x 850 = 722500 mm2
Clear cover to rebar = 50 mm
Details of reinforcement provided
Diameter of bar = 25 mm
No. of bars provided = 24 Nos.
Diameter of ties = 8 mm
Spacing of ties S= 100 mm c/c
Concrete Grade =
Comp. strength fck = 30 N/mm2
Steel Grade Fe 500D
500 N/mm
2
Yield strength ; fy =
Length of column 4500 mm

Area of reinforcement required from STAAD = 6142 mm2


\ Pt Required = 6142 x 100 / 722500 = 0.86 %
\ Pt Provided = ( π /4 x 252 ) x 100 / x 24 x 722500 = 1.64 %
No. of bars on one face = 8 Nos.
No. of bars on second face = 6 Nos.

\ Maximum spacing = (850 - 2 x 50 - 2 x 8 - 25 ) = 101.29 mm


7
Check for spacing between vertical bars

As per Cl. 7.4.8 of IS 13920 : 1993


The area of cross section, Ash of the bar forming rectangular hoop, to be used as special confining reinforce-
ment shall not be less than

Ash = 0.18S.h.fck /fy [ Ag / Ak - 1.0]


Where;
h = Longer dimension of the rectangular confining hoop measured to its outer face. ≤ 300 mm
Ak = Area of confined concrete core in the rectangular hoop measured to its outside dimensions.
The size of concrete core = 734 mm x 734 mm
Therefore; Ak = 734 x 734 = 538756 mm2
Ash = π /4 x8 ^2 = 50.27 mm2

\h= Ash / [0.18S.fck /fy (Ag / Ak - 1.0)]


h= 50.27 = 136.48 mm
0.18 x 100 x 30 / 500 ( 722500 / 538756 - 1.0 )
> 101.29 mm Therefore, O.K.
Special confining reinforcement shall be provided over a length L0 from each joint face,
As per Cl. 7.4.1 of IS 13920:1993
Length L0 shall not be less than,
a) large lateral dimension of member = 850 mm
b) 1/6 of clear span of the member = 1/6 x 4500 = 750 mm
c) 450 mm
\ Minimum length of special confining reinforcement is 850 mm
Provided length of special confining reinforcement is 900 mm Therefore, O.K.
Design of Column - C3 for confining reinforcement
Data

Pedestal Size 800 mm x 800 mm


Gross area of pedestal A g = 800 x 800 = 640000 mm2
Clear cover to rebar = 75 mm
Details of reinforcement provided
Diameter of bar = 25 mm
No. of bars provided = 20 Nos.
Diameter of ties = 10 mm
Spacing of ties S= 75 mm c/c
Concrete Grade = M-30
Comp. strength fck = 30 N/mm2
Steel Grade Fe 500D
500 N/mm
2
Yield strength ; fy =
Length of column 9650 mm

Area of reinforcement required from STAAD = 8736 mm2


\ Pt Required = 8736 x 100 / 640000 = 1.37 %
\ Pt Provided = ( π /4 x 252 ) x 100 / x 20 x 640000 = 1.54 %
No. of bars on one face = 6 Nos.
No. of bars on second face = 4 Nos.

\ Maximum spacing = (800 - 2 x 75 - 2 x 10 - 25 ) = 121 mm


5
Check for spacing between vertical bars

As per Cl. 7.4.8 of IS 13920 : 1993


The area of cross section, Ash of the bar forming rectangular hoop, to be used as special confining reinforce-
ment shall not be less than

Ash = 0.18S.h.fck /fy [ Ag / Ak - 1.0]


Where;
h = Longer dimension of the rectangular confining hoop measured to its outer face. ≤ 300 mm
Ak = Area of confined concrete core in the rectangular hoop measured to its outside dimensions.
The size of concrete core = 630 mm x 630 mm
Therefore; Ak = 630 x 630 = 396900 mm2
Ash = π /4 x10 ^2 = 78.54 mm2

\h= Ash / [0.18S.fck /fy (Ag / Ak - 1.0)]


h= 78.54 = 158.31 mm
0.18 x 75 x 30 / 500 ( 640000 / 396900 - 1.0 )
> 121 mm Therefore, O.K.
Special confining reinforcement shall be provided over a length L0 from each joint face,
As per Cl. 7.4.1 of IS 13920:1993
Length L0 shall not be less than,
a) large lateral dimension of member = 800 mm
b) 1/6 of clear span of the member = 1/6 x 9650 = 1608.34 mm
c) 450 mm
\ Minimum length of special confining reinforcement is 1608 mm
Provided length of special confining reinforcement is 1800 mm Therefore, O.K.