03 Rebar Inspection

This reinforcement inspection sheet documents an inspection of the rebar installation at the Kefita Apartments project located in Addis Ababa, Ethiopia. It lists parameters like approved shop drawings, grade and spacing of rebar, concrete cover, splices, chair placement, and more. For each parameter it indicates whether the criteria was met as yes/good, no/poor, or has notes. The sheet requires signatures from the contractor, consultant, and project manager to approve proceeding with works after inspection. It also notes the contractor must provide internal approval documents if requested by the consultant and must report daily on work progress.

Uploaded by

Dawit Solomon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views1 page

03 Rebar Inspection

This reinforcement inspection sheet documents an inspection of the rebar installation at the Kefita Apartments project located in Addis Ababa, Ethiopia. It lists parameters like approved shop drawings, grade and spacing of rebar, concrete cover, splices, chair placement, and more. For each parameter it indicates whether the criteria was met as yes/good, no/poor, or has notes. The sheet requires signatures from the contractor, consultant, and project manager to approve proceeding with works after inspection. It also notes the contractor must provide internal approval documents if requested by the consultant and must report daily on work progress.

Uploaded by

Dawit Solomon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Reinforcement Inspection Sheet

Reinforcement Inspection Sheet

Date: Sheet No.:


Project: KEFITA APARTMENTS PLC Location: ADDIS ABEBA, YEKA SUBCITY, ETHIOPIA
Employer: ROCKSTONE ETHIOPIA REAL ESTATE PLC
Contractor: HUA HONG CONSTRUCTION PLC
Consultant: BIGAR BUILDERS AND DEVELOPERS PLC
Structure type and level:
Structure label:
Rebar type used:
Parameters Yes/Good No/Poor Notes
Shop drawings approved
Grade of steel as per spec.
Spacing as per drawing
Required clearance from formwork
Length of splices (lap length)
Bars at openings provided
Bars are clean
Bars tied adequately
Chairs placed properly
Conduits in place
Rebar clearance for concrete pour
Coordination of pipes and sleeves
Setting-out
Support systems in place
Bars are staggered as per dwg.

NB: The contractor must issue internal approval


documents if and when such a document is requested by
the consultant
Additional Items/Comments:

Following the request for inspection, the works as per the above listed items and supportive documents have
been evaluated and permission to proceed is hereby Granted / Refused 

Contractor Consultant Project Manager


Name

Signature

After performing the works the contractor is to report on a daily bases the progress and performance of works.

Date:
Project:
Employer:
Contractor:
Consultant:
Yes/Good
No/Poor
Name 
Signature
Project Manager