You are on page 1of 45

SYSTEM TROUBLESHOOTING

2S BET LOURENÇO
 
Ø   MULTÍMETRO  0-­‐32  VDC  
 
Ø   CHAVE  PHILIPS  NÃO  MAGNÉTICA    

Ø   CHAVE  HEX  3/32  pol  

Ø   NÍVEL  DIGITAL  0.25  GRAUS  DE  PRECISÃO    

Ø   VHF  NAV/COM/ILS  RAMP  TEST    

Ø   TRANSPONDER  MODE  S  RAMP  TEST  

Ø   AIR  DATA  TEST  SET  

Ø   GPS  SIGNAL  AVAILABLE  

Ø   HEADSET  /  MICROPHONE    

Ø   SLIP-­‐CLUTCH  ADJUSTMENT  FIXTURE    (Garmin  P/N  


T10-­‐00110-­‐01)    
System Troubleshooting

Line  Maintenance  Manual,  Sec.on  2  


MFD AUX – SYSTEM STATUS
MFD AUX – SYSTEM STATUS
COM 2 failure

COM 2 failure but no Alert


Com  2  on  AUX  7  -­‐  System  Status  page  
COM 2 failure troubleshooting

Page 2-2
AFCS  TroubleshooUng  

AnnunciaUons  and  Alerts   SecUon  2  


AFCS  AnnunciaUons  

SecUon  2  
AFCS  AnnunciaUons  

SecUon  2  
SET>ACTIVE Feature

1.4.14 SET>ACTV / ACTV>SET


Throughout various configuration mode pages, there are SET and ACTIVE columns for input/
output settings and other parameters.
SET: Refers to a setting or group of settings that reside in the PFD’s internal memory and/or master
configuration module (See Figure 1-11).
ACTIVE: Refers to a current setting stored and used in a LRU. LRUs store the ‘active’ settings
within internal memory.

Data can be manually copied from one column to the other by using the following two softkeys:
• SET>ACTV (read ‘Set to Active’) softkey: Allows the installer to send the information in the
SET column (data stored in the master configuration module) to the ACTV column (data used by
LRU).
• ACTV>SET (read ‘Active to Set’) softkey: Causes the LRUs current settings to be copied to the
master configuration module as SET items.
In the first example shown in Figure 1-11, the SET columns do not match the ACTIVE columns.
The inequality between SET and ACTIVE indicates a configuration mismatch. By pressing the
SET>ACTV softkey, this copies the SET column to the LRU unit’s configuration memory. The
settings then become the ACTIVE settings for the LRU being configured.
SET/ACTIVE Feature
Configuration Mismatch

Master Configuration Module LRU Memory Master Configuration Module LRU Memory
“SET” “ACTIVE” “SET” “ACTIVE”

Note how the “SET” and “ACTIVE” Columns do not match,


this is something that you would see with a new unit install.
SET>ACTIVE Feature

Figure 1-11. SET/ACTV Feature


In most cases, when a setting is changed, the newer setting will automatically be
transferred to the appropriate LRU. The technician receives on-screen confirmation that
the configuration is successful, as depicted in Figure 1-12. Likewise, if a configuration
error is detected, it too is shown in similar fashion.

Figure 1-12. Configuration Status


SET>ACTIVE Feature

Press the SET >ACTIVE Soft key to update the configuration for the LRU. In
this case we have selected the GIA1 from the GIA page group
SET>ACTIVE Feature

Configuration Correct

Master Configuration Module LRU Memory Master Configuration Module LRU Memory
“SET” “ACTIVE” “SET” “ACTIVE”

After pressing the SET>ACTIVE Soft Key, the two columns should match.
ACTIVE > SET Feature

1.4.13 ACTV>SET Interface


The only time ACTV>SET should be used is when the master configuration module fails and must
be replaced. In this circumstance the ACTV>SET softkey may be used to reload correct
configuration settings from previously installed LRUs. Should a LRU be replaced along with the
master configuration module, the LRU needs to be reconfigured using the G1000 SW Loader Card.

WARNING
The ACTV>SET softkey must be used with caution! If an improperly configured unit is installed,
this softkey causes the wrong configuration to replace the correct aircraft configuration!
FIOS EXPOSTOS FORAS DOS
CONECTOR E PINOS CORRETOS
PINOS