16

24

4 × No.9 bars
24 2 legs × No.4 @ 8" c
4 × No.8 bars
16
202.000
21.5

3.142
1.216

0.80
2.772
3.465
0.01561

0.90
315.950
284.355

3.667
40000
2.000
10.000

265.500
21.436

3.997
1.213

0.80
3.527
4.409
0.01159

0.90
393.185
353.867

3.624
40000
2.000
10.000

2.496
1.000
2.667
1.000

0.000
1.00
36.378
0.000
145.512
0.000
0.170

0.000

0.589

10.718
RC beam deRectangular section detailsSection width; b = inSection depth;
h = inPositive moment. Rectangular section in flexure (Section 9.5.2)Factored bending moment at
section; Mu = Mpos_s1 = kip_ftEffective depth to tension
reinforcement; d = inTension reinforcement provided; 4  No.8
barsArea of tension reinforcement provided; As,prov = in2Minimum area of reinforcement
(cl.9.6.1.2); As,min = max(3 psi  (f'c / 1 psi), 200 psi)  b  d / fy =
in2PASS - Area of reinforcement provided is greater than minimum area of reinforcement requiredStress
block depth factor (cl.22.2.2.4.3); 1 = min(max(0.85 - 0.05  (f'c - 4 ksi) / 1 ksi, 0.65), 0.85)
= Depth of equivalent rectangular stress block; a = As,prov  fy / (0.85  f'c  b) = inDepth to neutral
axis; c = a / 1 = inNet tensile strain in extreme tension
fibers; t = 0.003  (do - c) / max(c, 0.001 in) = Net tensile
strain in tension controlled zoneStrength reduction factor (cl.21.2.1); f = min(max(0.65 +
(t - 0.002)  (250 / 3), 0.65), 0.9) = Nominal moment strength; Mn = As,prov  fy  (d
- a / 2) = kip_ftDesign moment strength; Mn = Mn  f = kip_ftPASS - Required moment
strength is less than design moment strengthFlexural crackingMax. center to center spacing of tension
reinf.; sb,max = sbot + s1_b_L1 = inService load stress in
reinforcement (cl.24.3.2); fs = 2/3  fy = psiClear cover of reinforcement; cc =
cnom_b + v = inMaximum allowable bot bar spacing (Table 24.3.2); smax = min(15in 
40000psi / fs - 2.5  cc, 12in  40000psi / fs) = inPASS - Maximum allowable tension reinforcement
spacing exceeds actual spacingNegative moment. Rectangular section in flexure (Section 9.5.2)Factored
bending moment at section; Mu = Mneg_s1 = kip_ftEffective depth to tension
reinforcement; d = inTension reinforcement provided; 4  No.9
barsArea of tension reinforcement provided; As,prov = in2Minimum area of reinforcement
(cl.9.6.1.2); As,min = max(3 psi  (f'c / 1 psi), 200 psi)  b  d / fy =
in2PASS - Area of reinforcement provided is greater than minimum area of reinforcement requiredStress
block depth factor (cl.22.2.2.4.3); 1 = min(max(0.85 - 0.05  (f'c - 4 ksi) / 1 ksi, 0.65), 0.85)
= Depth of equivalent rectangular stress block; a = As,prov  fy / (0.85  f'c  b) = inDepth to neutral
axis; c = a / 1 = inNet tensile strain in extreme tension
fibers; t = 0.003  (do - c) / max(c, 0.001 in) = Net tensile
strain in tension controlled zoneStrength reduction factor (cl.21.2.1); f = min(max(0.65 +
(t - 0.002)  (250 / 3), 0.65), 0.9) = Nominal moment strength; Mn = As,prov  fy  (d
- a / 2) = kip_ftDesign moment strength; Mn = Mn  f = kip_ftPASS - Required moment
strength is less than design moment strengthFlexural crackingMax. center to center spacing of tension
reinf.; st,max = stop + s1_t_L1 = inService load stress in
reinforcement (cl.24.3.2); fs = 2/3  fy = psiClear cover of reinforcement; cc =
cnom_t + v = inMaximum allowable top bar spacing (Table 24.3.2); smax = min(15in 
40000psi / fs - 2.5  cc, 12in  40000psi / fs) = inPASS - Maximum allowable tension reinforcement
spacing exceeds actual spacingSpacing limits for reinforcementTop bar clear spacing; stop = (b - (2 
(cnom_s + s1_v) + s1_t_L1  Ns1_t_L1)) / (Ns1_t_L1 - 1) = inMin. allowable top bar clear spacing
(cl.25.2.1); stop,min = inBottom bar clear spacing; sbot =
(b - (2  (cnom_s + s1_v) + s1_b_L1  Ns1_b_L1)) / (Ns1_b_L1 - 1) = inMin. allowable bottom bar
clear spacing (cl.25.2.1); sbot,min = inPASS - Actual bar spacing exceeds
minimum allowableRectangular section in shearDesign shear force; Vu = kipsConcrete
weight modification factor;  = Concrete shear strength (eqn. 22.5.5.1); Vc =
s    2 psi  (f'c / 1 psi)  b  d = kipsReinforcement shear strength (eqn. 22.5.1.1); Vs =
max(Vu - Vc, 0 kips) = kipsMaximum reinforcement shear strength; Vs,max = s  8 psi
 (min(f'c, 10000psi) / 1 psi)  b  d = kipsArea of design shear reinf. required (eqn. 22.5.10.5.3);
Asv,des = Vs / (s  min(fy, 60000 psi)  d) = in2/ftMinimum area of shear reinforcement (Table
9.6.3.3); Asv,min = max(50 psi, 0.75 psi  (f'c / 1 psi))  b /
min(fy, 60000 psi) = in2/ftVc/2 >= Vu - no reinforcement requiredArea of shear reinforcement required;
Asv,req = in2/ftShear reinforcement provided; 2 legs  No.4 @ 8" c/cArea of shear reinforcement
provided; Asv,prov = in2/ftPASS - No shear reinforcement
required (Vc/2 >= Vu)Maximum longitudinal spacing (Table 9.7.6.2.2); svl,max = min(d / 2, 24
in) = inPASS - longitudinal spacing of stirrups is less than the maximum allowable