Dead Tank Circuit Breaker 145PM40-C

Compact design with enhanced reliability


ABB innovations for changing demands

ABB (www.abb.com) is a leader in power and automation A complete range of high voltage circuit breakers
technologies that enables utility and industry customers to ABB offers the widest range of high voltage circuit breakers on
improve their performance while lowering environmental the market. Our portfolio of dead tank circuit breakers ranges
impact. from 72.5 kV to 800 kV.

The ABB Group of companies operates in approximately ABB has a long history of developing innovative technologies
100 countries and employs around 145,000 people. to address the changing demands of power systems. As
these systems continue to evolve, switching solutions must be
designed to meet present-day applications as well as anticipate
the future state of the grid.

2 | 145PM40-C Dead Tank Circuit Breaker


Compact design with enhanced reliability

ABB is proud to offer the Type 145PM40-C SF6 Dead Tank Benefits of ABB’s advanced technology
Circuit Breaker, based on well-established interrupter and
operating mechanism platforms. Common platform
– The design shares common features and existing technology
Standards with other ABB switchgear platforms, ensuring established
The 145PM40-C Dead Tank Circuit Breaker is tested for high and time-tested reliability.
transient recovery voltage (TRV) performance and is certified – The 145PM40-C offers the most commonly purchased
for class C2 capacitive switching and class M2 mechanical features as standard or available options.
endurance.
High performance and long life for all applications
– ANSI/IEEE C37.09 – The 145PM40-C dead tank circuit breaker is certified for
– ANSI/IEEE C37.04 Class C2 capacitive switching and Class M2 mechanical
– ANSI/IEEE C37.06 endurance (10,000 operations).
– ANSI/IEEE C37.06.1 – Our high performance, dual-motion self-blast interrupter
– IEC 62271-1 achieves full ratings up to 145 kV, 40 kA.
– IEC 62271-100 – The breaker is designed for a design life of a minimum of
thirty (30) years under normal operating environments.
Certifications
– ISO 9001 Environmental awareness
– ISO 14001 – The type PM uses SF6 as the insulating medium. ABB
– OHSAS 18001 has invested a great deal to reduce SF 6 leaks through
design, manufacturing techniques and innovative monitoring
Applications technologies. The 145PM40-C also utilizes 20% less SF6
The 145PM40-C was designed for: than other state-of-the-art designs.
– overhead transmission lines
– transformer applications Ease of installation and maintenance
– capacitive switching applications – The type 145PM40-C is shipped completely assembled
and filled with positive SF6 pressure, allowing for the quickest
Type PM circuit breaker family installation time in the industry.
With just under 50,000 breakers delivered to date, spanning – Only standard tools are required for installation, inspection
voltages up to 800 kV, the ABB type PM dead tank circuit and normal maintenance and repair tasks.
breakers remain the most purchased brand in the industry. This
is due to their low cost of ownership and strong performance, MSD mechanism
backed by industry-leading service and support. The MSD mechanism incorporates proven design principles from
ABB’s earlier spring operating mechanisms, including stable,
reliable, low power operating latches and cam disc operation
for closing operation control.

The MSD torsion spring operating mechanism is designed with a


minimum of components, ensuring a high degree of total reliability
and minimal need for maintenance.

An important innovation of the MSD design is the use of the


torsion springs for opening and closing energy storage. This
allows for a very compact design, with both closing and opening
springs contained within the operating mechanism.

145PM40-C Dead Tank Circuit Breaker | 3


Features

Tanks Bushings
Single-piece tanks are ultrasonically cleaned. Each tank is ABB offers a variety of bushing options, including silicone and
ASME pressure vessel tested and certified, and receives a UM porcelain insulators, to meet customer application needs and
stamp. environmental conditions. ABB utilizes tapered designs, where
feasible, to reduce the SF6 volume and therefore installed
Control cubicle inventory in our customer’s fleet.
ABB prides itself on offering generously sized control cubicles
at workable heights to vastly improve access to the equipment Bushing current transformers
over its lifetime. ABB utilizes slipover bushing current transformer (BCT) designs
for our dead tank product line which allow for cost effective,
Insulating medium efficient and safe removal or exchange without removing the
The Type 145PM40-C uses SF6 as the insulating medium. bushings.
ABB has invested in monitoring technology, manufacturing
techniques, and innovative designs to reduce SF 6 gas leaks. MSD1 mechanism
The closing springs in the MSD1 mechanism generate the required
Single-piece interrupter driving force to close the circuit breaker and charge the opening
Our single-piece high-performance modular interrupters employ spring. Immediately after each closing operation, a motor drives the
state-of-the-art technology that minimizes line-ground insulation spring charging gear to automatically charge the closing springs.
components. After recharging the closing springs, the circuit breaker is capable
of a rapid reclosing with a dead time interval of 0.3 s (i.e. O - 0.3 s -
CO stored energy).

4 | 145PM40-C Dead Tank Circuit Breaker


Technical data

Rated per ANSI and IEC standards


Maximum continuous voltage kV 145
Operating frequency Hz 50 / 60
Interrupting time 3 cycles (50 ms)
Impulse withstand voltage
2 µ-sec chopped wave kV Peak 838
Full wave lightning impulse (BIL) kV Peak 650
Power frequency withstand voltage
60 Hz 1 minute dry withstand kV 310
60 Hz 1 minute wet withstand kV 275
Continuous current A 2000, 3000, 3150 (2)
Close and latch current kA 104
Short circuit breaking current kA 40
Minimum operating gas pressure @ 20° C psig / MPa, abs 72 / 0.60
Normal operating gas pressure @ 20° C psig / MPa, abs 87 / 0.70
Permissible ambient temperature °C -40 to +55 (1)
Interrupter enclosure dead tank
Configuration 3 pole units on single frame
Design outdoor
Expected lifetime yrs ≥30
Dimensions (H x W x L) ft / mm 14.8 x 11.6 x 8.2 / 4330 x 3540 x 2500
Weight, SF6 gas lbs / kg 46 / 21
Operating mechanism
Type spring-spring, type MSD1
Quantity per breaker 1
Energy storage torsion spring
Standard operating duty O-0.3s-CO-15s-CO
Seismic rating 0.5g value per IEEE 693
Charging source universal motor
48 VDC
Available voltages 110 - 125 VAC or VDC
220 - 250 VAC or VDC
Power 900 W
16 A @ 48 V
Charging motor Operating current 12 A @ 110 V
6 A @ 220 V
125 A @ 48 V
Peak starting current 50 A @ 110 V
25 A @ 220 V
Max recharge time 15 seconds
48 VDC
Available voltages 110-125 VDC
220-250 VDC
10 A @ 48 V
2.1 A @ 110 V
Trip
Trip and close coils 4.4 A @ 110 V
2.0 A @ 220 V
Current
10 A @ 48 V
2.1 A @ 110 V
Close
4.4 A @ 110 V
2.0 A @ 220 V
Above are not necessarily limiting values; further information available upon request.

Notes
(1)
Requires tank heaters on applications with ambient temperatures less than -30º C
(2)
Limited continuous current ratings at greater than +40 C
145PM40-C Dead Tank Circuit Breaker | 5
Dimensions and specifications

139.64” (3547) 95.70” (2431)


SHIPPING AND INSTALLED WIDTH SHIPPING AND INSTALLED LENGTH

61.37” (1559)
69.13” (1756) PHASE SPACING
PHASE SPACING
49.61” (1260)
55.86” (1419) METAL TO METAL
METAL TO METAL

168.19”
(4272)
INSTALLED
HEIGHT

158.35”
(4022)
TOP OF
TERMINAL
PAD
106.77” (2712)
MIN DISTANCE TO
UNDERGROUND PARTS 92.91”
MIN BUSHING HEIGHT 147.36” (2360)
(3743) q OF
HEIGHT BREAKER
TO LIVE
51.54”
PARTS
(1309)
HEIGHT TO
BOTTOM OF
CONTROL
CABINET
44.25”
(1124)
HEIGHT OF
EXTENSION
LEGS

95.70” (2431)
SHIPPING AND INSTALLED LENGTH
Physical data
61.37” (1559)
PHASE SPACING
Height - installed 168.19 in (4272 mm)
49.61” (1260)
METAL TO METAL Width - installed 139.64 in (3547 mm)
Length - installed 95.70 in (2431 mm)
Footprint of frame 60.23 in x 46.14 in
(1530 mm x 1172 mm)
Phase spacing 69.13 in (1756 mm)
Minimum height to 106.77 in (2712 mm)
ungrounded parts
Shipping weight 5860 lbs (2658 kg)
Typical installed weight 6070 lbs (2753 kg)
with porcelain bushings and
maximum BCT’s

92.91”
(2360)
q OF
BREAKER

6 | 145PM40-C Dead Tank Circuit Breaker


Protection and control interfaces

Typical electrical drawings


21 1 5A
(+) (+)

/
52X1 52X1

9A 5B
23-1 52Y1

42-1 11A
52Y1
52B
CABINET CABINET 52A
120 / 240 88-1 HEATER 125 / 250 VDC 125 / 250 VDC 52B
HEATER
VA C 75 W 52Y1
75 W
52B
42-1 52A

52Y1 52X1 52CC-1

52TC1

63 (LOW GAS)

63 (LOW SPRING)

(-) (-)
22 2

AC schematic Primary DC trip DC close - pole 1


42-1 Motor contactor 9A – 11A Remote trip pole 1 52X1 X relay, closing
88-1 Motor 52A Auxiliary switch contact 52Y1 Y relay, anti pump
23-1 Non-adjustable thermostat 52TC1 Trip coil 52B Auxiliary switch contact
5A – 5B Remote close and reclose
52CC-1 Close coil
Notes: 63 Permissive contact / alarm contact
1) Secondary trip is same as primary

Typical controls features Popular CT options

Accessory Accuracy
Dual trip coils ANSI

125 VDC Ratio Relaying Metering IEC

AC / DC transfer 600:5 MR C-400 / C-800 0.3B-0.5 5P10@15VA

Mini-monitor 1200:5 MR C-400 / C-800 0.3B-1.0 CLASS 0.5@30VA

EB-27 CT terminal blocks 2000:5 MR C-400 / C-800 0.3B-1.0 10P20@50VA


3000:5 MR C-400 / C-800 0.3B-1.8 CLASS 0.5@30VA
Cabinet light - door activated
4000:5 MR C-400 / C-800 0.3B-2.0 CLASS 0.2@15VA
20 A GFI (cabinet exterior)
Non-insulated wire terminals
Fused knife switches
Open/close push buttons
Undervoltage relays
Local remote switch
Screw down device nameplates

145PM40-C Dead Tank Circuit Breaker | 7


Shipping and installation

With the exception of the high voltage terminals and extension Installation and commissioning
legs, the type 145PM40-C ships fully assembled with positive The compact design is ideal for new or existing substation
gas pressure. For domestic deliveries, all components are layouts for voltages up to 145 kV. The breaker fits within most
transported to the customer on a single-drop, air ride trailer. existing footprints and can be used to quickly address the need
Weight of gas at shipping pressure is provided with test report. for greater protection for minimal cost.

Those familiar with the PM line of breakers can typically install


and commission the breaker within 2 days given a prepared
foundation.

ABB offers supervision, installation, commissioning, and


maintenance service on all ABB breakers.

Representative installation of a 145 kV PM breaker in the United States.

8 | 145PM40-C Dead Tank Circuit Breaker


Notes

145PM40-C Dead Tank Circuit Breaker | 9


Contact us

ABB Inc. Note:


We reserve the right to make technical changes or modify the contents of this
High Voltage Products - Dead Tank Breakers document without prior notice. With regard to purchase orders, the agreed
100 Distribution Circle particulars shall prevail. ABB does not accept any responsibility whatsoever for

Document Number: 2GNM110151 / April 2016


potential errors or possible lack of information in this document. We reserve
Mount Pleasant, Pennsylvania 15666, USA all rights in this document and in the subject matter and illustrations contained
Phone: +1 (724) 696-1500 therein. Any reproduction–in whole or in parts–is forbidden without ABB’s prior
written consent.
Fax: +1 (724) 696-1502
Copyright 2016 ABB.
www.abb.us/highvoltage
All rights reserved.