You are on page 1of 73

E L

M I L B A N K
E C T R I C A L
METER MOUNTING EQUIPMENT
Q
STANDARD CATALOG
U General Office
MILBANK MANUFACTURING COMPANY
P.O. Box 419028

I Kansas City, MO
64141-0028
Tel (816) 483-5314
Fax (816) 483-6357

P Shipping Address
4801 Deramus
Kansas City, MO
M 64120-9990

E
Manufacturing Plants Located in
Kansas City, MO

N A
N
UF
ACT U RI
N
G
El Dorado, AR
M

MADE
C
K

IN
M IL BA N

USA
MP

Concordia, MO
AN Y

Kokomo, IN
T K
A
NS
A S C I T Y, M
O
Anaheim, CA
SMC 8/97 (10K) All products made in America
ilbank Manufacturing Company was established in 1927 by

M Charles A. Milbank. Originally, the company manufactured high


voltage switches; however, by 1941 Milbank devoted itself pri-
marily to the manufacture of sheet metal enclosures and related equip-
ment for the electrical generating and distribution industry.

As metering standards have changed, Milbank has been successful in


adapting its product line to meet these changes. Our full scale
Engineering Department designs enclosures to meet customer specifica-
tions and satisfy all utility requirements. Our five manufacturing facilities
gives us the flexibility to schedule and produce orders quickly. Currently,
Milbank manufactures over 6,000 different catalog items, and this list is
still growing. If you don’t find a unit in this catalog to service your needs,
Robert F. Waldrop
Chairman of the Board
send us your specifications and we will be happy to work with you.

Milbank has been serving the electric utility industry for over 70 years with
innovative, quality-engineered products. So remember us for all of your
meter mounting and related requirements, and we will be happy to serve you as we have in the past —with
dependable service and quality products!

EL DORADO, ARKANSAS KOKOMO, INDIANA

KANSAS CITY, MISSOURI

ANAHEIM, CALIFORNIA CONCORDIA, MISSOURI

1
INDEX
DISCONNECTS (30-200 AMP)

30 & 60 AMP—FUSIBLE / NON-FUSIBLE A/C DISCONNECTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6


30,60, 100 & 200 AMP—NON-FUSIBLE—SINGLE THROW—TYPE 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
30, 60 & 100 AMP—NON-FUSIBLE—DOUBLE THROW—TYPE 1 INDOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
100 & 200 AMP—NON-FUSIBLE—DOUBLE THROW—TYPE 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

SINGLE POSITION (NO BYPASS)

125-200 AMP—4 & 5 TERMINAL—RINGLESS/RING TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10,11,12


200 AMP—4 & 5 TERMINAL—SIDE WIREWAY—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
125 & 200 AMP—7 TERMINAL—NON JAW CLAMPING—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
200 AMP—4 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
200 AMP—5 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
200 AMP—7 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
320 AMP—4 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

SINGLE POSITION (LEVER BYPASS)

200 AMP—4 & 5 TERMINAL—SIDE WIREWAY—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13


200 AMP—4 & 5 TERMINAL—LEVER BYPASS—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
125 & 200 AMP—7 TERMINAL—NON JAW CLAMPING—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
200 AMP—4 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
200 AMP—5 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
200 AMP—7 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
320 AMP—4 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19,20
320 AMP—7 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

CT RATED

20 AMP—4,5,6,7,8 &13 TERMINAL—WITH PLUNGER TYPE BYPASS—RINGLESS/RING TYPE . . . . . . . . . . . . . .22


20 AMP—5,6,8 & 13 TERMINAL—WITH TEST SWITCH PROVISION—RINGLESS/RING TYPE . . . . . . . . . . . . .23,24
400 AMP—6,8 & 13 TERMINAL—TRANS-S-PACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
600 AMP—6,8,13 & 14 TERMINAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
1600 AMP—MAXI-TRANSOCKET WITH P.T’S & BAR TYPE C.T.’S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

TEST SWITCHES

TEST SWITCHES—4,7, & 10 POLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

OUTDOOR TRANSFORMER CABINETS

OUTDOOR TRANSFORMER CABINETS—TYPE 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29


BACKBOARDS AND PANELS FOR TRANSFORMER CABINETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

MULTIPLE POSITION (VERTICAL GANGS)

100 AMP / POSITION—4 & 5 TERMINAL—VERTICAL GANGS—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

MULTIPLE POSITION (HORIZONTAL GANGS)

100, 125 AMP / POSITION—4 TERMINAL—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31,32


150 & 200 AMP / POSITION—4 TERMINAL—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
200 AMP / POSITION—5 & 7 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . .34
100 & 200 AMP / POSITION—4 TERMINAL—C/B’S—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

CONDOMINIUM METERING BANKS


125,200 AMP / POSITION—VERTICAL & RECTANGULAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

2
INDEX
METER MAINS

100,150 & 200 AMP—4 TERMINAL—RINGLESS/RING TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38,41


100,150 & 200 AMP—4 TERMINAL—METER SOCKET C/B COMBO—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . .39
100, 150 & 200 AMP—4 TERMINAL—WITH LOAD SIDE DISTRIBUTION—RINGLESS . . . . . . . . . . . . . . . . . . . . . .40
200 AMP—4 TERMINAL—SERVICE ENTRANCE MAIN COMO—METERED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
200 AMP—SERVICE ENTRANCE—MAIN COMBO—BREAKER ENCLOSURE . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
100 AMP—4 & 7 TERMINAL—RING TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
100 & 200 AMP—4,5 & 7 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
320 AMP—4 TERMINAL—RINGLESS/RING TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
320 AMP—4 TERMINAL—JAW CLAMPING LEVER—2/200 AMP C/B—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . .46

POWER OUTLETS

20,30 & 50 AMP—RECEPTACLE BOX—TYPE 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48


100 AMP—METERED & UNMETERED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

PEDESTALS

100 AMP POWER OUTLET PEDESTALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50


100 AMP—RECREATIONAL VEHICLE PEDESTALS—RING TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
200 AMP—ALL PURPOSE METERED PEDESTALS—RING TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
100-200 AMP—4 TERMINAL—METERED & UNMETERED POWER OUTLET . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
125 & 200 AMP—4 TERMINAL—METERED & UNMETERED RV/MH PEDESTALS . . . . . . . . . . . . . . . . . . . . . . . . .55
200 AMP—4 TERMINAL—MOBILE HOME PEDESTALS—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
POWER OUTLET FITTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
ACCESSORIES FOR MOBILE HOME PEDESTAL HARDWIRED UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
ACCESSORIES FOR MOBILE HOME PEDESTALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58

POLYPHASE ENCLOSURES

POLYPHASE ENCLOSURES FOR “A” BASE METERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59

CABLE TELEVISION

CABLE TELEVISION PEDESTALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60

SECONDARY SERVICE PEDESTALS

SECONDARY SERVICE PEDESTALS FOR UNDERGROUND USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61

ACCESSORIES

METER SOCKET ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62,63

BREAKERS

MILBANK WEST BREAKERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64

REPLACEMENT PARTS

REPLACEMENT PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65

GENERAL ENGINEERING

MATERIALS & FINISHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66


CONDUIT & AMPACITY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
ENERGIZATION OF ELECTRICAL EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
WATTHOUR METERS—STANDARD FORMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
METER FORMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
PRODUCT SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71

3
NUMERIC INDEX
105J . . . . . . . . . . .53,62 K4212 . . . . . . . . . . . . .65 S2777-4X . . . . . . . . . .28 U1211 . . . . . . . . . . . . .14
243210-CT3R . . . . . . .29 K4213 . . . . . . . . . . . . .65 S2811-4X . . . . . . . . . .28 U1252 . . . . . . . . . . . .33
243610-CT3R . . . . . . .29 M-5 . . . . . . . . . . . . . . .62 S3310-O . . . . . . . . . . .58 U1253 . . . . . . . . . . . .33
303610-CT3R . . . . . . .29 M400-APS . . . . . . . . .45 S3831 . . . . . . . . . . . . .27 U1254 . . . . . . . . . . . .33
303612-CT3R . . . . . . .29 M400-PAR . . . . . . . . .45 S3912 . . . . . . . . . . . . .27 U1255 . . . . . . . . . . . .33
304010-CT3R . . . . . . .29 M400-UG-APS-LC . . .45 S4017 . . . . . . . . . . . . .29 U1256 . . . . . . . . . . . .33
323610-CT3R . . . . . . .29 M400-UG-APS-P . . . .45 S4019 . . . . . . . . . . . . .29 U1431 . . . . . . . . . . . .19
363016-CT3R . . . . . . .29 M400-UG-PAR . . . . . .45 S4020 . . . . . . . . . . . . .29 U1432 . . . . . . . . . . . .19
363612-CT3R . . . . . . .29 M400-UG-PAR-P . . . .45 S7860 . . . . . . . . . . . . .29 U1797 . . . . . . . . . . . .19
423012-CT3R . . . . . . .29 MHD . . . . . . . . . . . . . .53 S8032-CB . . . . . . . . . .35 U1819 . . . . . . . . . . . .19
423616-CT3R . . . . . . .29 MPAP . . . . . . . . . . . . .52 S8033-CB . . . . . . . . . .35 U1980 . . . . . . . . . . . .13
443010-CT3R . . . . . . .29 MPAP-200 . . . . . . . . .52 S8034-CB . . . . . . . . . .35 U2120 . . . . . . . . . . . .21
483612-CT3R . . . . . . .29 MPAPD . . . . . . . . . . . .52 S8035-CB . . . . . . . . . .35 U2124 . . . . . . . . . . . .20
484812-CT3R . . . . . . .29 MPRV . . . . . . . . . . . . .51 S8036-CB . . . . . . . . . .35 U2161 . . . . . . . . . . . .26
5T8K2 . . . . . . . . . . . .62 MPRV-100 . . . . . . . . .51 S8180 . . . . . . . . . . . . .62 U2228 . . . . . . . . . . . .26
6003 . . . . . . . . . . . . . .63 MPRVD . . . . . . . . . . .51 S8324 . . . . . . . . . . . . .63 U2229 . . . . . . . . . . . .26
6116 . . . . . . . . . . . . . .63 MR-2 . . . . . . . . . . . . .62 S9064 . . . . . . . . . . . . .63 U2288 . . . . . . . . . . . .36
703865 . . . . . . . . . . . .62 MR-4 . . . . . . . . . . . . .62 S9617 . . . . . . . . . . . . .61 U2351 . . . . . . . . . . . .36
A7514 . . . . . . . . . . . . .63 MUPO . . . . . . . . . . . .49 S9618 . . . . . . . . . . . . .61 U2448 . . . . . . . . . . . .20
A7515 . . . . . . . . . . . . .63 MUSE-20 . . . . . . . . . .42 S9647-RL-100 . . . . . .40 U2569 . . . . . . . . . . . .13
A7516 . . . . . . . . . . . . .63 MUSE-AP-200-MB . . .42 S9647-RL-150 . . . . . .40 U2594 . . . . . . . . . . . .21
A7517 . . . . . . . . . . . . .63 MUSE-AP-200-ML . . .42 S9647-RL-200 . . . . . .40 U2692 . . . . . . . . . . . .30
A7518 . . . . . . . . . . . . .63 P-10 . . . . . . . . . . . . . .49 S9648-RL-100 . . . . . .40 U2693 . . . . . . . . . . . .30
A7551 . . . . . . . . . . . . .63 P-13 . . . . . . . . . . . . . .49 S9690 . . . . . . . . . . . . .29 U2732 . . . . . . . . . . . .34
A8110 . . . . . . . . . . . . .63 P-54 . . . . . . . . . . . . . .49 S9691 . . . . . . . . . . . . .29 U2733 . . . . . . . . . . . .34
A8111 . . . . . . . . . . . . .63 PD-RW . . . . . . . . . . . .53 S9692 . . . . . . . . . . . . .29 U2734 . . . . . . . . . . . .34
A8112 . . . . . . . . . . . . .63 PF-KR . . . . . . . . . . . .53 S9693 . . . . . . . . . . . . .29 U2735 . . . . . . . . . . . .34
CP-21 . . . . . . . . . . . . .63 PS-104 . . . . . . . . . . . .53 S9694 . . . . . . . . . . . . .29 U2736 . . . . . . . . . . . .34
EK-6 . . . . . . . . . . . . . .53 R27S . . . . . . . . . . . . . .7 S9695 . . . . . . . . . . . . .29 U2852 . . . . . . . . . . . .36
GC-2 . . . . . . . . . . . . .53 R8993 . . . . . . . . . . . . .7 S9995 . . . . . . . . . . . . .59 U2853 . . . . . . . . . . . .36
HP-UPO4 . . . . . . . . . .50 RMK-100 . . . . . . . . . .53 S9997 . . . . . . . . . . . . .59 U2854 . . . . . . . . . . . .36
HPDUPO4 . . . . . . . . .50 RW27 . . . . . . . . . . . . . .7 S9999 . . . . . . . . . . . . .59 U2855 . . . . . . . . . . . .36
K1179 . . . . . . . . . . . . .62 RW9012NX . . . . . . . . .9 SCRCW . . . . . . . . . . .59 U2856 . . . . . . . . . . . .36
K1190 . . . . . . . . . . . . .62 RW9013X . . . . . . . . . . .9 SDRC . . . . . . . . . . . . .59 U2862 . . . . . . . . . . . .36
K1190 . . . . . . . . . . . . .65 RW9022NX . . . . . . . . .9 TPAP . . . . . . . . . . . . .52 U2863 . . . . . . . . . . . .36
K1350 . . . . . . . . . . . . .63 RW9023X . . . . . . . . . . .9 TS04-0101 . . . . . . . . .25 U2864 . . . . . . . . . . . .36
K1539 . . . . . . . . . . . . .63 S111526 . . . . . . . . . . .59 TS04-0102 . . . . . . . . .25 U2865 . . . . . . . . . . . .36
K1540 . . . . . . . . . . . . .63 S112730 . . . . . . . . . . .59 TS04-0103 . . . . . . . . .25 U2866 . . . . . . . . . . . .36
K1541 . . . . . . . . . . . . .63 S113830 . . . . . . . . . . .59 TS04-0104 . . . . . . . . .25 U2872 . . . . . . . . . . . .34
K2381 . . . . . . . . . . . . .62 S1252-CB . . . . . . . . . .35 TS07-0018 . . . . . . . . .25 U2873 . . . . . . . . . . . .34
K3082 . . . . . . . . . . . . .63 S1253-CB . . . . . . . . . .35 TS07-0022 . . . . . . . . .25 U2874 . . . . . . . . . . . .34
K3083 . . . . . . . . . . . . .63 S1254-CB . . . . . . . . . .35 TS07-0049 . . . . . . . . .25 U2875 . . . . . . . . . . . .34
K3188 . . . . . . . . . . . . .58 S1255-CB . . . . . . . . . .35 TS07-0059 . . . . . . . . .25 U2876 . . . . . . . . . . . .34
K3235 . . . . . . . . . . . . .58 S1256-CB . . . . . . . . . .35 TS07-0105 . . . . . . . . .25 U2986 . . . . . . . . . . . .13
K3236 . . . . . . . . . . . . .58 S1890 . . . . . . . . . . . . .27 TS07-0106 . . . . . . . . .25 U3136 . . . . . . . . . . . .57
K3237 . . . . . . . . . . . . .58 S1891 . . . . . . . . . . . . .27 TS07-0107 . . . . . . . . .25 U3137 . . . . . . . . . . . .57
K3308 . . . . . . . . . . . . .58 S2068 . . . . . . . . . . . . .13 TS07-0108 . . . . . . . . .25 U3138 . . . . . . . . . . . .57
K3309 . . . . . . . . . . . . .58 S2096-LP . . . . . . . . . .60 TS10-0109 . . . . . . . . .25 U3139 . . . . . . . . . . . .55
K3439 . . . . . . . . . . . . .58 S2096-O . . . . . . . . . . .60 TS10-0110 . . . . . . . . .25 U3140 . . . . . . . . . . . .55
K3441 . . . . . . . . . . . . .63 S2097-O . . . . . . . . . . .60 TS10-0111 . . . . . . . . .25 U3142 . . . . . . . . . . . .55
K3442 . . . . . . . . . . . . .63 S2098-O . . . . . . . . . . .60 TS10-0112 . . . . . . . . .25 U3143 . . . . . . . . . . . .55
K3450 . . . . . . . . . . . . .58 S2099-O . . . . . . . . . . .60 TT350 . . . . . . . . . . . . .53 U3144 . . . . . . . . . . . .56
K3515 . . . . . . . . . . . . .58 S2100 . . . . . . . . . . . . .60 TV-835 . . . . . . . . . . . .53 U3200 . . . . . . . . . . . .38
K3778 . . . . . . . . . . . . .58 S2100-32 . . . . . . . . . .60 U-HUB . . . . . . . . . . . .53 U3221 . . . . . . . . . . . .57
K3785 . . . . . . . . . . . . .63 S2101 . . . . . . . . . . . . .60 U1079 . . . . . . . . . . . .19 U3240 . . . . . . . . . . . .55
K3865 . . . . . . . . . . . . .62 S2674 . . . . . . . . . . . . .27 U1129 . . . . . . . . . . . . .19 U3241 . . . . . . . . . . . .55
K3866 . . . . . . . . . . . . .62 S2690 . . . . . . . . . . . . .27 U1207 . . . . . . . . . . . .14 U3249 . . . . . . . . . . . .55

4
NUMERIC INDEX
U3250 . . . . . . . . . . . .55 U8143 . . . . . . . . . . . .41 UC3423 . . . . . . . . . . .24 Z902134-SC . . . . . . . .66
U3278 . . . . . . . . . . . .14 U8144 . . . . . . . . . . . .41 UC3425 . . . . . . . . . . .24 Z902198-SC . . . . . . . .66
U3348 . . . . . . . . . . . .54 U8212 . . . . . . . . . . . .31 UC3426 . . . . . . . . . . .24 Z902201-SC . . . . . . . .66
U3350 . . . . . . . . . . . .54 U8213 . . . . . . . . . . . .31 UC3428 . . . . . . . . . . .24 Z902210-SC . . . . . . . .66
U3424 . . . . . . . . . . . .43 U8214 . . . . . . . . . . . .31 UC3433 . . . . . . . . . . .24 Z902231-SC . . . . . . . .66
U3427 . . . . . . . . . . . .43 U8215 . . . . . . . . . . . .31 UC3434 . . . . . . . . . . .24 Z903273-AO . . . . . . . .66
U3479 . . . . . . . . . . . .14 U8216 . . . . . . . . . . . .31 UC3435 . . . . . . . . . . .24 Z903274-AO . . . . . . . .66
U3491 . . . . . . . . . . . .41 U9318 . . . . . . . . . . . .14 UC3436 . . . . . . . . . . .24 Z903303-AC . . . . . . . .66
U3499 . . . . . . . . . . . .41 U9319 . . . . . . . . . . . .14 UC3438 . . . . . . . . . . .24 Z903323-AC . . . . . . . .66
U3564 . . . . . . . . . . . .43 U9320 . . . . . . . . . . . .15 UC7233 . . . . . . . . . . .22 Z903603-AC . . . . . . . .66
U3567 . . . . . . . . . . . .43 U9321 . . . . . . . . . . . .15 UC7235 . . . . . . . . . . .22 Z904485-AO . . . . . . . .66
U3575 . . . . . . . . . . . .43 U9352 . . . . . . . . . . . .33 UC7237 . . . . . . . . . . .22 Z904486-AO . . . . . . . .66
U3585 . . . . . . . . . . . .43 U9353 . . . . . . . . . . . .33 UC7442 . . . . . . . . . . .23 Z904529-AC . . . . . . . .66
U3598 . . . . . . . . . . . .14 U9354 . . . . . . . . . . . .33 UC7444 . . . . . . . . . . .23 Z905524-AO . . . . . . . .66
U3741 . . . . . . . . . . . .44 U9355 . . . . . . . . . . . .33 UC7445 . . . . . . . . . . .23 Z905553-AO . . . . . . . .66
U3769 . . . . . . . . . . . .48 U9356 . . . . . . . . . . . .33 UC7446 . . . . . . . . . . .23 Z906203-AC . . . . . . . .66
U3771 . . . . . . . . . . . .44 U9550 . . . . . . . . . . . .17 UC7448 . . . . . . . . . . .23 Z909408-SC . . . . . . . .66
U3781 . . . . . . . . . . . .44 U9551 . . . . . . . . . . . .17 UC7449 . . . . . . . . . . .23 Z909745-SC . . . . . . . .66
U3784 . . . . . . . . . . . .54 U9556 . . . . . . . . . . . .17 UC7450 . . . . . . . . . . .23 Z910889-SC . . . . . . . .66
U3791 . . . . . . . . . . . .44 U9557 . . . . . . . . . . . .17 UC7460 . . . . . . . . . . .23 Z911163-AC . . . . . . . .66
U3800 . . . . . . . . . . . . .6 U9564 . . . . . . . . . . . .17 UC7461 . . . . . . . . . . .23 Z911194-AC . . . . . . . .66
U3803 . . . . . . . . . . . . .6 U9565 . . . . . . . . . . . .17 UC7478 . . . . . . . . . . .23 Z911500-AC . . . . . . . .66
U3806 . . . . . . . . . . . . .6 U9566 . . . . . . . . . . . .17 UC7532 . . . . . . . . . . .23 Z911531-AC . . . . . . . .66
U3849 . . . . . . . . . . . .46 U9567 . . . . . . . . . . . .17 UC7544 . . . . . . . . . . .22 Z911639-SC . . . . . . . .66
U3900 . . . . . . . . . . . .38 U9652 . . . . . . . . . . . .32 UC7545 . . . . . . . . . . .22 Z912015-SC . . . . . . . .66
U3924 . . . . . . . . . . . .13 U9653 . . . . . . . . . . . .32 UC7546 . . . . . . . . . . .22 Z912040-SC . . . . . . . .66
U4031 . . . . . . . . . . . .46 U9654 . . . . . . . . . . . .32 UC7636 . . . . . . . . . . .23 Z912173-SC . . . . . . . .66
U4210 . . . . . . . . . . . .12 U9655 . . . . . . . . . . . .32 UCB-2100 . . . . . . . . .65 Z912197-SC . . . . . . . .66
U4215 . . . . . . . . . . . .14 U9656 . . . . . . . . . . . .32 UCFP-100 . . . . . . . . .65 Z912269-SC . . . . . . . .66
U7017 . . . . . . . . . . . .12 U9700 . . . . . . . . . . . .18 UCFP-PA . . . . . . . . . .65 Z912291-SC . . . . . . . .66
U7018 . . . . . . . . . . . .12 U9701 . . . . . . . . . . . .18 UCP-2100 . . . . . . . . .65
U7021 . . . . . . . . . . . .12 U9706 . . . . . . . . . . . .18 UPO . . . . . . . . . . . . . .49
U7040 . . . . . . . . . . . .12 U9707 . . . . . . . . . . . .18 UQFB-100 . . . . . . . . .65
U7262 . . . . . . . . . . . . .11 U9760 . . . . . . . . . . . .18 UQFB-125 . . . . . . . . .65
U7310 . . . . . . . . . . . . .11 U9761 . . . . . . . . . . . .18 UQFB-150 . . . . . . . . .65
U7362 . . . . . . . . . . . .31 U9762 . . . . . . . . . . . .18 UQFB-175 . . . . . . . . .65
U7363 . . . . . . . . . . . .31 U9763 . . . . . . . . . . . .18 UQFB-200 . . . . . . . . .65
U7364 . . . . . . . . . . . .31 U9800 . . . . . . . . . . . .16 UQFB-PA . . . . . . . . . .65
U7365 . . . . . . . . . . . .31 U9801 . . . . . . . . . . . .16 UQFP-125 . . . . . . . . .65
U7366 . . . . . . . . . . . .31 U9806 . . . . . . . . . . . .16 UQFP-150 . . . . . . . . .65
U7420 . . . . . . . . . . . .15 U9807 . . . . . . . . . . . .16 UQFP-175 . . . . . . . . .65
U7421 . . . . . . . . . . . .15 U9864 . . . . . . . . . . . .16 UQFP-200 . . . . . . . . .65
U7422 . . . . . . . . . . . .15 U9865 . . . . . . . . . . . .16 USE-20 . . . . . . . . . . .47
U7423 . . . . . . . . . . . .15 U9866 . . . . . . . . . . . .16 USE-22-200-MB . . . . .47
U7487 . . . . . . . . . . . .10 U9867 . . . . . . . . . . . .16 USE-AP-200-MB . . . . .47
U7490 . . . . . . . . . . . .10 UAP9270 . . . . . . . . . .39 USE-AP-200-ML . . . . .47
U7573 . . . . . . . . . . . .15 UAP9271 . . . . . . . . . .39 USE-M-200-MB . . . . .42
U7588 . . . . . . . . . . . .10 UAP9274 . . . . . . . . . .39 USE-M-200-ML . . . . . .42
U8032 . . . . . . . . . . . .32 UAP9275 . . . . . . . . . .39 W9012A . . . . . . . . . . . .8
U8033 . . . . . . . . . . . .32 UAP9276 . . . . . . . . . .39 W9013A . . . . . . . . . . . .8
U8034 . . . . . . . . . . . .32 UAP9328 . . . . . . . . . .39 W9032A . . . . . . . . . . . .8
U8035 . . . . . . . . . . . .32 UC1288 . . . . . . . . . . .22 W9033A . . . . . . . . . . . .8
U8036 . . . . . . . . . . . .32 UC1289 . . . . . . . . . . .22 W9062A . . . . . . . . . . . .8
U8084 . . . . . . . . . . . . .11 UC1290 . . . . . . . . . . .22 W9063A . . . . . . . . . . . .8
U8085 . . . . . . . . . . . . .11 UC1291 . . . . . . . . . . .22 WS . . . . . . . . . . . . . . .59
U8087 . . . . . . . . . . . .10 UC1299 . . . . . . . . . . .22 Z900079-SC . . . . . . . .66
U8100 . . . . . . . . . . . .15 UC1300 . . . . . . . . . . .22 Z901994-SC . . . . . . . .66

5
30 & 60 AMP—FUSIBLE/NONFUSIBLE AIR CONDITIONER DISCONNECT—TYPE 3R

U3806

U3803 U3800

In order to remove cover, the


dead front must be removed first.

PROFILE

Milbank’s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets
all wire bending space requirements in the NEC and, also, complies with article 440-14 in the NEC. To insure the safest con-
ditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety fea-
ture is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galva-
nized steel and finished with an attractive, light gray, baked powder coating. Our “state of the art” finish combines epoxy and
polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading
finish.

TECHNICAL INFORMATION
LINE & LOAD GROUND
CATALOG MAX WT. WIRE RANGE WIRE RANGE DIMENSIONS WIRE RATING
AMP TYPE
NUMBER H.P. @ CU AL CU/AL D″″ W″″ H″″ CU °C AL °C
#
NONFUSIBLE #14-#2 #12-#2 #14-4 AWG 3 5 8 60°/75° 60°
60 U3800 10 3.25 AWG AWG
#14-#2 #12-#2 #14-4 AWG 3 5 8 60°/75° 60°
60 FUSIBLE U3806 10 3.7 AWG AWG
#14-#2 #12-#2 #14-4 AWG 3 5 8 60°/75° 60°
30 FUSIBLE U3803 3 3.7 AWG AWG

✓ U/L listed as Enclosed Pullout Switch ✓ Type 3R Rainproof

✓ U/L listed to Canadian Standard


✓ Six one-inch concentric knockouts

✓ Removable Cover ✓ ∅, 120/240 VAC


1∅

✓ Standard Package of 12

6
30, 60, 100 & 200 AMP—NON-FUSED SWITCHES—TYPE 3R—DISCONNECT

F
2 WIRE

2 Blades / No Neutral

G H
3 WIRE 1 WIRE

3 Blades / No Neutral 1 Blade / No Neutral

NON-FUSED SWITCHES— SINGLE THROW—TYPE 3R—OUTDOOR

Rainproof non-fused single throw, general duty switches are used to disconnect loads which do not require overcurrent protec-
tion or which have an overcurrent device elsewhere. These switches serve as a safe, effective method of shutting off power to
a piece of equipment or structure such as a barn, garage or illuminated sign. They may be used in residential, farm or light
commercial applications. As with all Milbank products, our enclosure is constructed of galvanized steel and finished with an
attractive, light gray, baked powder coating. Our “state of the art” finish combines epoxy and polyester hybrid resins into a hybrid
powder coating which is then electrostatically applied. This offers a durable, nonfading finish.

TECHNICAL INFORMATION
SWITCH HORSE POWER RATINGS DIMENSIONS HANDLE
HUB POLE AMP CATALOG ELECTRICAL
TYPE PROJEC-
NUMBER RATINGS
10K AIC ∅
1∅ ∅
3∅ D″″ W″″ H″″ TION

1 1 120V AC
➁ H 30 R27S KNIFE ∅)
(1∅ ⁄2 @ 120 AC—1 ⁄2 @ 125 DC 23 ⁄4 33
⁄8 51⁄2 125V DC MAX
1″

➁ F 30 RW27 KNIFE ∅) 3 @ 240 AC—3 @ 250 DC


(1∅ 2 7
⁄8 53
⁄8 67
⁄8 240V AC 1″

SH G 30 R8993 ➀ KNIFE — 71⁄2 @ 240AC 3 6 83⁄4 120 / 240V AC 1″

➀ The R8993 is shipped with a small closure plate. To order hub separately refer to the hub suffix chart on the
accessory page.
➁ No hub provision.

7
30, 60 & 100 AMP—NON-FUSED SWITCHES—DOUBLE THROW—TYPE 1 / INDOOR

L
3 WIRE

K
2 WIRE
3 Blades / No Neutral

M
2 WIRE

2 Blades / No Neutral
N
TYPE 1 2 Blades / Solid Neutral

NON-FUSED SWITCHES / DOUBLE THROW—TYPE 1—INDOOR—OUTDOOR


Rainproof, double throw, non-fused switches transfer loads from one source of supply to another, typically from a utility source
to a backup generator, while providing protection against potentially dangerous backfeeding of the utility system. Designed to
operate at 100% of rated load, the quick-make / quick-break design assures many years of safe, reliable use. As with all
Milbank products, our enclosure is constructed of galvanized steel and finished with an attractive, light gray, baked powder
coating. Our “state of the art” finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then
electrostatically applied. This offers a durable, nonfading finish. They are not intended to be used as motor circuit protection.
Typical applications include locations where loss of power for an extended length of time would cause damage or hazard. All
switches rated 10,000 AIC.

TYPE 1—INDOOR

SWITCH DIMENSIONS
CATALOG ELECTRICAL HANDLE
HUB POLE AMP TYPE
NUMBER D″″ W″″ H″″ RATINGS PROJECTIONS
(10K AIC)
— K 30 W9032A KNIFE 41⁄2 81⁄4 101⁄4 240V AC, 250V DC MAX. 21⁄4″

— K 60 W9062A KNIFE 6 113⁄8 145⁄8 240V AC, 250V DC MAX. 2″


3 1 1
— K 100 W9012A KNIFE 6 ⁄4 11 ⁄2 21 ⁄4 240V AC 2″

— L 60 W9063A KNIFE 6 113⁄8 145⁄8 120 / 240 AC 2″


3 1 1
— L 100 W9013A KNIFE 6 ⁄4 11 ⁄2 21 ⁄4 120 / 240 AC 2″

GROUNDING BAR: Order separately, catalog number GBK2.


HUBS: Type 1 switches do not have hub provision.

8
100 & 200 AMP—NON-FUSED SWITCHES—DOUBLE THROW—TYPE 3R

L
3 WIRE

K
3 Blades / No Neutral 2 WIRE

M
2 WIRE

N 2 Blades / No Neutral

2 Blades / Solid Neutral

TYPE 3R

NON-FUSED SWITCHES / DOUBLE THROW—TYPE 3R—OUTDOOR


Rainproof, double throw, non-fused switches transfer loads from one source of supply to another, typically from a utility source
to a backup generator, while providing protection against potentially dangerous backfeeding of the utility system. Designed to
operate at 100% of rated load, the quick-make / quick-break design assures many years of safe, reliable use. As with all
Milbank products, our enclosure is constructed of galvanized steel and finished with an attractive, light gray, baked powder
coating. Our “state of the art” finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then
electrostatically applied. This offers a durable, nonfading finish. They are not intended to be used as motor circuit protection.
Typical applications include locations where loss of power for an extended length of time would cause damage or hazard. All
switches rated 10,000 AIC.

TYPE 3R—OUTDOOR

SWITCH DIMENSIONS
CATALOG ELECTRICAL HANDLE
HUB POLE AMP TYPE
NUMBER D″″ W″″ H″″ RATINGS PROJECTIONS
(10K AIC)
LH M 100 RW9012NX* KNIFE 63⁄4 111⁄2 211⁄2 120 / 240 AC 2″

LH M 200 RW9022NX* KNIFE 85⁄8 141⁄8 291⁄8 120 / 240 AC 21⁄4″

LH L 100 RW9013X KNIFE 63⁄4 111⁄2 211⁄2 120 / 240 AC 2″

LH L 200 RW9023X KNIFE 85⁄8 141⁄8 291⁄8 120 / 240 AC 21⁄4″

GROUNDING BAR: Order separately, catalog number GBK2.


HUBS: All Type 3R switches shipped with closing plates. To order hub separately refer to the accessory page.
*NX: Units supplied with neutral.

9
125 AMP—4 & 5 TERMINAL—RINGLESS / RING TYPE—600 VAC

1 2

7487
4 3 4 7588
5 6

U7487-RL U7588-XL

125 AMP—4 TERMINAL—RINGLESS


CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
5 1 1 1 1
125 OH/UG U7487-RL H.O. #6-2/0 #6-2/0 NO 3 ⁄16 8 11 ⁄2 1 ⁄2 1 ⁄2 2 11⁄4 — ⁄4
1 1 1 1 1 1 1 1 1
125 OH/UG U7588-XL C.P. #6-2/0 #6-2/0 NO 4 ⁄8 11 15 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 ⁄ ⁄
4, 2 ⁄4

125 AMP—4 TERMINAL—RING TYPE


CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
5 1 1
125 OH/UG U7490-RL H.O. #6-2/0 #6-2/0 NO 3 ⁄16 8 11 ⁄2 1 ⁄2 11⁄2 2 11⁄4 — 1
⁄4
1 1 1 1 1 1 1 1 1
125 OH/UG U8087-XL C.P. #6-2/0 #6-2/0 NO 4 ⁄8 11 15 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 ⁄ ⁄
4, 2 ⁄4
HUBS: For proper hub selection see the hub suffix chart on the accessory page.
FIFTH TERMINAL: For field mounted fifth terminal order catalog number 5T8K2.
CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral. For triplex ground, add
suffix “-TG” to the catalog number.
SEALING RINGS: Ring type units are supplied with MR-2, snap action, sealing rings as standard.
BYPASS: Horn type bypass is available for these units. Add the suffix “-KK” to the catalog number.
FLUSH MOUNT: Some styles are available in flush mount. Contact factory for pricing and availability.

10
150 AMP—4 & 5 TERMINAL—RINGLESS / RING TYPE—600 VAC

1 2

7262
5
3 6
7310

U7262-RL 1 2 U8084-RL

4 3 8084
4
5 6 8085

150 AMP–4 TERMINAL–RINGLESS


CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
1 1 1 1 1 1 1 1
150 OH U7262-RL H.O. #2-350 kcmil #2-350 kcmil NO 4 ⁄8 8 15 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 — ⁄4 ⁄ ⁄
4, 2

1 1 1 1 1 1 1 1 1
150 OH/UG U8084-XL C.P. #2-350 kcmil #2-350 kcmil NO 4 ⁄8 11 15 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 ⁄ ⁄
4, 2 ⁄4

150 AMP–4 TERMINAL–RING TYPE


CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
1 1 1 1 1 1 1 1
150 OH U7310-RL H.O. #2-350 kcmil #2-350 kcmil NO 4 ⁄8 8 15 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 — ⁄4 ⁄ ⁄
4, 2

1 1 1 1 1 1 1 1 1
150 OH/UG U8085-XL C.P. #2-350 kcmil #2-350 kcmil NO 4 ⁄8 11 15 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 ⁄ ⁄
4, 2 ⁄4

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
FIFTH TERMINAL: For field mounted fifth terminal order catalog number 5T8K2.
CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral. For triplex ground, add
suffix “-TG” to the catalog number.
SEALING RINGS: Ring type units are supplied with MR-2, snap action, sealing rings as standard.
BYPASS: Horn type bypass is available for these units. Add the suffix “-KK” to the catalog number.

11
200 AMP—4 & 5 TERMINAL—RINGLESS / RING TYPE—600 VAC

1 2

7021
5
3 6 7017

U7021-RL U7040-XL

1 2

7040
4 3 4 7018
5 6
4210

200 AMP—4 TERMINAL—RINGLESS


CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
1 1 1 1 1 1 1 1
200 OH U7021-RL** H.O. #2-350 kcmil #2-350 kcmil NO 4 ⁄8 8 15 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 — ⁄4 ⁄ ⁄
4, 2

1 1 1 1 1 1 1 1 1
200 OH/UG U7040-XL** C.P. #2-350 kcmil #2-350 kcmil NO 4 ⁄8 11 15 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 ⁄ ⁄
4, 2 ⁄4
3/8″ x 16 1 1 1 1 1 1 1 1 1
200 OH/UG U4210-XL** C.P. #2-350 kcmil STUDS * NO 4 ⁄8 11 20 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 ⁄ ⁄
4, 2 ⁄4

200 AMP—4 TERMINAL—RING TYPE


CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
1 1 1 1 1 1 1 1
200 OH U7017-RL H.O. #2-350 kcmil #2-350 kcmil NO 4 ⁄8 8 15 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 — ⁄4 ⁄ ⁄
4, 2

1 1 1 1 1 1 1 1 1
200 OH/UG U7018-XL C.P. #2-350 kcmil #2-350 kcmil NO 4 ⁄8 11 15 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 2 ⁄2 ⁄ ⁄
4, 2 ⁄4

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
FIFTH TERMINAL: For field mounted fifth terminal order catalog number 5T8K2.
CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral. For triplex ground, add
suffix “-TG” to the catalog number.
SEALING RINGS: Ring type units are supplied with MR-2, snap action, sealing rings as standard.
BYPASS: Horn type bypass is available for units. Add the suffix “-KK” to the catalog number.
FLUSH MOUNT: Above products are available in flush mount. Contact factory for pricing and availability.
* Order load side connectors as extra. See price sheet for adder.
**TRIPLEX GROUND factory installed as standard.

12
200 AMP—4 & 5 TERMINAL—RINGLESS —600 VAC

FOR
UNDERGROUND USE
WITH SIDE WIRE SPACE

U3924-XL U2569-O

Overhead / Underground Service

1 2

3924

2068
1980
3 4 5 2569
6
2986 U1980-O

200 AMP—4 TERMINAL—SIDE WIREWAY—RINGLESS


CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
7 1 1 1 1 1
200 OH / UG U3924-XL C.P. #6-350 kcmil #6-350 kcmil LEVER 4 ⁄8 14 20 ⁄2 2 ⁄2 2 ⁄2 3 ⁄ ⁄
4, 2 3 —
3/8″-16 1 1 1 1
3 1 1 1 1
200 UG *S2068-O BLANK
STUD #2-350 kcmil NO 4 ⁄2 13 15 ⁄4 2 ⁄2 2 ⁄2 1 ⁄2 2 ⁄2 ⁄ ⁄
4, 2

1 1 1 1 1 1 1 1
200 UG U1980-O BLANK #2-350 kcmil #2-350 kcmil NO 4 ⁄2 13 15 ⁄2 2 ⁄2 2 ⁄2 3 1 ⁄2 2 ⁄2 ⁄ ⁄
4, 2

3/8″-16 1 1 1
3 1 1 1 1
200 UG U2569-O BLANK
STUD #2-350 kcmil NO 4 ⁄2 13 19 2 ⁄2 2 ⁄2 1 ⁄2 2 ⁄2 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 1 1 1
3 1 1 1 1
200 UG U2986-O BLANK
STUD STUD NO 4 ⁄2 13 19 2 ⁄2 2 ⁄2 1 ⁄2 2 ⁄2 ⁄ ⁄
4, 2

* The S2068-O unit is non U/L. For U/L listed unit see other choices on this page.
FIFTH TERMINAL: For factory installed fifth terminal in the 9 o’clock position add the suffix “-5T”. For field mounted fifth termi-
nal order catalog number 5T8K2.
CONNECTORS: Extruded aluminum connectors are tin plated (except 3924 unit.) Units are supplied with triplex neutral. Stud
type units supplied with 3/8”-16 hex head nuts with Belleville washers. For connector kits, order as extra: K1539 (350kcmil.)
BYPASS: The U3924-XL unit is supplied with a lever bypass which supplies clamping action on meter spades and also oper-
ates bypass device. Horn type bypass is available for other units. Add suffix “-KK” to catalog number.

13
200 AMP—LEVER BYPASS—4 & 5 TERMINAL—RINGLESS
NON JAW CLAMPING—600 VAC

NEW!
RESIDENTIAL BYPASS SERIES

1 2

3278
4 3 2 3598
55 6

1 2 1 2

1211
9319 1207
4 3 4 4216 3 6 9318 U3278-RL
U9318-RL 5 6 5
3479 (New Style Bypass)

∅3W OR 3∅
200 AMP—4 & 5 TERMINAL—RESIDENTIAL BYPASS—RINGLESS—1∅ ∅3W
CONNECTORS
CATALOG CU/ALBY- DIMENSIONS CONCENTRIC K.O.’S
TERM SERVICE HUB
NUMBER LINE & LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
1 1 1 1 1 1 1
4 OH U3278-RL H.O. #2-350 kcmil LEVER 4 ⁄8 11 15 ⁄2 2 ⁄2 2 ⁄2 2 2 ⁄ ⁄
4, 2 ⁄4
1 1 1 1 1 1 1
5 OH U3598-RL* H.O. #2-350 kcmil LEVER 4 ⁄8 11 15 ⁄2 2 ⁄2 2 ⁄2 2 2 ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
4 OH/UG U4216-RXL C.P. #2-350 kcmil LEVER 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

7 1 1 1 1
5 OH/UG U3479-RXL C.P. #2-350 kcmil LEVER 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

FIFTH TERMINAL: For field mounted fifth terminal, order as extra K3356 for the 3278 and 4216.

∅3W OR 3∅
200 AMP—4 & 5 TERMINAL—RINGLESS—1∅ ∅3W
CONNECTORS
CATALOG CU/ALBY- DIMENSIONS CONCENTRIC K.O.’S
TERM SERVICE HUB
NUMBER LINE & LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
7 1 1 1 1 3
4 OH U1207-RL H.O. #6-350 kcmil LEVER 4 ⁄8 10 18 ⁄2 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
4 OH/UG U1211-XL C.P. #6-350 kcmil LEVER 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

7 1 1 1 1 3
5 OH U9318-RL H.O. #6-350 kcmil LEVER 4 ⁄8 10 18 ⁄2 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
5 OH/UG U9319-XL C.P. #6-350 kcmil LEVER 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

FIFTH TERMINAL: For field mounted fifth terminal, order as extra K3866 for the 1207 or 1211.
HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever operates bypass device only; does not provide clamping action on meter spades.
CONNECTORS: Units are supplied with extruded aluminum connectors and bonded, triplex neutral.
**TRIPLEX GROUND factory installed as standard.

14
125 & 200 AMP—7 TERMINAL—RINGLESS—NON JAW CLAMPING—600 VAC

1 2
7422
7423
4 3 4 9320
5 6 9321

1 2

7420
7421
5
3 6 7573
8100

U7421-RL U9320-RRL

∅4W
125 AMP—7 TERMINAL—RINGLESS—3∅
CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
7 1 1 1 3
125 OH U7573-RL H.O. #6-2/0 #6-2/0 LEVER 4 ⁄8 10 18 ⁄2 2 2 2 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 3
125 OH U8100-RL H.O. #6-2/0 #6-2/0 NO 4 ⁄8 10 18 ⁄2 2 2 2 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
125 OH/UG U9320-RRL H.O. #6-2/0 #6-2/0 LEVER 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

1 1 1 1 1
125 OH/UG U9321-RRL H.O. #6-2/0 #6-2/0 NO 4 ⁄2 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

∅4W
200 AMP—7 TERMINAL—RINGLESS—3∅
CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
7 1 1 1 1 3
200 OH U7420-RL H.O. #6-350 kcmil #6-350 kcmil NO 4 ⁄8 10 18 ⁄2 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1 3
200 OH U7421-RL H.O. #6-350 kcmil #6-350 kcmil LEVER 4 ⁄8 10 18 ⁄2 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
200 OH/UG U7422-RXL C.P. #6-350 kcmil #6-350 kcmil NO 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

1 1 1 1 1
200 OH/UG U7423-RXL C.P. #6-350 kcmil #6-350 kcmil LEVER 4 ⁄2 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever operates bypass device only; does not provide clamping action on meter spades.
CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex neutral.
For field installed insulated neutral in the 13″ wide 7422 and 7423 units order kit number K1047.

15
200 AMP—4 TERMINAL—RINGLESS—JAW CLAMPING LEVER—600 VAC

1 2
9801
9807
4 3 4 9865
5 6 9867

1 2
9800
9806
9864
5
3 6
9866

U9865-RRL U9801-RRL

∅3W
200 AMP—4 TERMINAL—RINGLESS—1∅
CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
7 1 1 1 1 3
200 OH U9800-RRL H.O. #6-350 kcmil #6-350 kcmil LEVER 4 ⁄8 10 18 ⁄2 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
200 OH/UG U9801-RRL H.O. #6-350 kcmil #6-350 kcmil LEVER 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

7 1 1 1 1 3
200 OH U9806-RRL H.O. #6-350 kcmil #6-350 kcmil NO 4 ⁄8 10 18 ⁄2 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
200 OH/UG U9807-RRL H.O. #6-350 kcmil #6-350 kcmil NO 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 1 1 1 1 3
200 OH U9864-RRL H.O. STUD STUD
LEVER 4 ⁄8 10 28 ⁄4 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
3/8″-16 3/8″-16 7 1 1 1 1 1
200 OH/UG U9865-RRL H.O. STUD STUD
LEVER 4 ⁄8 13 28 ⁄4 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 1 1 1 1 3
200 OH U9866-RRL H.O. STUD STUD NO 4 ⁄8 10 28 ⁄4 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
3/8″-16 3/8″-16 7 1 1 1 1 1
200 OH/UG U9867-RRL H.O. STUD STUD NO 4 ⁄8 13 28 ⁄4 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Stud type units supplied with 3/8″-16 hex head nuts with Belleville washers. For connector kits, order as extra:
K1539 (350kcmil) or K1540 (600kcmil). Separate kits are required for line and load. Units supplied with extruded aluminum con-
nectors and bonded triplex neutral.
FIFTH TERMINAL: For field installed fifth terminal order catalog number K3866.

16
200 AMP—5 TERMINAL—JAW CLAMPING LEVER—RINGLESS—600 VAC

1 2
9551
9557
4 3 4 9565
5 6 9567

1 2

9550
9556
5
3 6 9564
9566
U9550-RXL U9564-DL

∅3W OR 3∅
200 AMP—5 TERMINAL—RINGLESS—1∅ ∅3W
CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
7 1 1 1 1 3
200 OH U9550-RRL H.O. #6-350 kcmil #6-350 kcmil LEVER 4 ⁄8 10 18 ⁄2 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
200 OH/UG U9551-RRL H.O. #6-350 kcmil #6-350 kcmil LEVER 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

7 1 1 1 1 3
200 OH U9556-RRL H.O. #6-350 kcmil #6-350 kcmil NO 4 ⁄8 10 18 ⁄2 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
200 OH/UG U9557-RRL H.O. #6-350 kcmil #6-350 kcmil NO 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 1 1 1 1 3
200 OH U9564-RRL H.O. STUD STUD
LEVER 4 ⁄8 10 28 ⁄4 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
3/8″-16 3/8″-16 7 1 1 1 1 1
200 OH/UG U9565-RRL H.O. STUD STUD
LEVER 4 ⁄8 13 28 ⁄4 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 1 1 1 1 3
200 OH U9566-RRL H.O. STUD STUD NO 4 ⁄8 10 28 ⁄4 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
3/8″-16 3/8″-16 7 1 1 1 1 1
200 OH/UG U9567-RRL H.O. STUD STUD NO 4 ⁄8 13 28 ⁄4 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Stud type units supplied with 3/8″-16 hex head nuts with Belleville washers. For connector kits, order as extra:
K1539 (350kcmil) or K1540 (600kcmil). Separate kits are required for line and load. Units supplied with extruded aluminum
connectors and bonded triplex neutral.
FIFTH TERMINAL: Fifth terminal is supplied in the 6 o’clock position. For factory installed fifth terminal in the 9 o’clock posi-
tion add the suffix “-5T9” to the catalog number.

17
200 AMP—7 TERMINAL—JAW CLAMPING LEVER—RINGLESS—600 VAC

1 2
9701
9707
4 3 4 9761
5 6 9763

1 2

9700
9706
5
3 6
9760
9762
U9700-RRL U9761-RRL

∅4W
200 AMP—7 TERMINAL—RINGLESS—3∅
CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
7 1 1 1 1 3
200 OH U9700-RRL H.O. #6-350 kcmil #6-350 kcmil LEVER 4 ⁄8 10 18 ⁄2 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
200 OH/UG U9701-RRL H.O. #6-350 kcmil #6-350 kcmil LEVER 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

7 1 1 1 1 3
200 OH U9706-RRL H.O. #6-350 kcmil #6-350 kcmil NO 4 ⁄8 10 18 ⁄2 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
7 1 1 1 1
200 OH/UG U9707-RRL H.O. #6-350 kcmil #6-350 kcmil NO 4 ⁄8 13 19 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 1 1 1 1 3
200 OH U9760-RRL H.O. STUD STUD
LEVER 4 ⁄8 10 28 ⁄4 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
3/8″-16 3/8″-16 7 1 1 1 1 1
200 OH/UG U9761-RRL H.O. STUD STUD
LEVER 4 ⁄8 13 28 ⁄4 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 1 1 1 1 3
200 OH U9762-RRL H.O. STUD STUD NO 4 ⁄8 10 28 ⁄4 3 2 ⁄2 3 — ⁄ ⁄
4, 2 ⁄4
3/8″-16 3/8″-16 7 1 1 1 1 1
200 OH/UG U9763-RRL H.O. STUD STUD NO 4 ⁄8 13 28 ⁄4 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Stud type units supplied with 3/8″-16 hex head nuts with Belleville washers. For connector kits, order as extra:
K3082 (350kcmil) or K3441 (600kcmil). Separate kits are required for line and load. Units supplied with extruded aluminum
connectors and bonded triplex neutral.
INSULATED NEUTRAL: For field installed insulated neutral for catalog numbers U9701 and U9707 order kit number K1047.

18
320 AMP CONTINUOUS— 4 TERMINAL
JAW CLAMPING LEVER—RINGLESS—600 VAC

320 AMP CONTINUOUS


400 AMP MAX

U1797-X

U1129-O
U1079-R

1 2 1 2

1079,1431 1797
3 3 4 4 3 4 1819
5
1129,1432 
5 6
6

∅3W
320 AMP—4 TERMINAL—RINGLESS—1∅
CONNECTORS
CATALOG CU/AL 5T BY- DIMENSIONS CONCENTRIC K.O.’S
SERVICE HUB
NUMBER LINE LOAD KIT PASS D″″ W″″ H″″ 1 2 3 4 5 6
3/8″-16 3/8″-16 7 3 1 1 1 1
OH U1079-R H.O. STUD STUD K3866 LEVER 4 ⁄8 13 38 ⁄4 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 3 1 1 1 1
OH U1431-R H.O. STUD STUD K3866 NO 4 ⁄8 13 38 ⁄4 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 3 1 1 1 1
UG U1129-O BLANK STUD STUD K3865 LEVER 4 ⁄8 13 29 ⁄4 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 3 1 1 1 1
UG U1432-O BLANK STUD STUD K3865 NO 4 ⁄8 13 29 ⁄4 3 2 ⁄2 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 1 1 1
UG U1797-X C.P. STUD STUD K3865 LEVER 4 ⁄8 15 30 3 3 3 3 ⁄4 ⁄ ⁄
4, 2

3/8″-16 3/8″-16 7 1 1 1
UG U1819-X C.P. STUD STUD K3865 NO 4 ⁄8 15 30 3 3 3 3 ⁄4 ⁄ ⁄
4, 2

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: On the U1079, U1129 and the U1797 the lever supplies clamping action and also operates bypass device.
CONNECTORS: Stud type units supplied with 3/8″-16 hex head nuts with Belleville washers. For connector kits, order as extra:
K1539 (350kcmil) or K1540 (600 kcmil). For twin lug connectors order as extra: K1350 (350 kcmil). Separate kits are required for
both line and load. The K1350 kit will not fit on the line side of the U1129 or the U1819.
FIFTH TERMINAL: For factory installed fifth terminal in the 6 o’clock position add the suffix “-5T6” to the catalog number. For
factory installed fifth terminal in the 9 o’clock position at the suffix “-5T9” to the catalog number.

19
320 AMP CONTINUOUS—4 TERMINAL—JAW CLAMPING LEVER—RINGLESS—600 VAC

320 AMP CONTINUOUS


400 AMP MAX

1 2

2448
3 3
4 5 6 2124

U2124-X U2448-X

∅3W
320 AMP—4 TERMINAL—SIDE WIREWAY—RINGLESS—1∅
CONNECTORS FIFTH BY- DIMENSIONS CONCENTRIC K.O.’S
SERVICE CATALOG HUB
CU/AL
TERM. PASS
NUMBER LINE LOAD KITS D″″ W″″ H″″ 1 2 3 4 5 6
3/8″-16 3/8″-16 1
OH/UG U2448-X C.P. STUD STUD K3865 LEVER 6 ⁄2 173⁄4 341⁄8 — 3 4
1
⁄4 1
⁄2,3⁄4,1 —
3/8″-16 3/8″-16 3 1 1 1
UG *U2124-X C.P. STUD STUD K3865 LEVER 5 ⁄4 16 30 3 ⁄2 3 ⁄2 4 ⁄4 — 1
⁄2,3⁄4,1

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: The lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Stud type units supplied with 3/8″-16 hex head nuts with Belleville washers. For connector kits, order as extra:
K1539 (350kcmil) or K1540 (600kcmil). For twin lug connectors order as extra: K1350 (350kcmil). Separate kits are required
for both line and load.
FIFTH TERMINAL: For factory installed fifth terminal in the 6 o’clock position add the suffix “-5T6” to the catalog number. For
factory installed fifth terminal in the 9 o’clock position at the suffix “-5T9” to the catalog number.

* For the same unit with anti-inversion feature order catalog number U1915-X.

20
320 AMP —CONTINUOUS—7 TERMINAL—JAW CLAMPING LEVER—RINGLESS—600 VAC

320 AMP CONTINUOUS


400 AMP MAX.

2120
3 5
6 4 2594

U2594-X U2120-X

∅4W
320 AMP—SIDE WIREWAY—7 TERMINAL—RINGLESS—3∅
CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
AMP SERVICE HUB
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 6
3/8″-16 3/8″-16 1
320 UG U2120-X C.P. STUD STUD
LEVER 6 ⁄2 173⁄4 313⁄4 4 3 4 4
1
⁄4 1
⁄2,3⁄4,1
3/8″-16 3/8″-16 1
320 OH/UG U2594-X C.P. STUD STUD
LEVER 6 ⁄2 173⁄4 341⁄8 — 3 4 4
1
⁄4 1
⁄2,3⁄4,1

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Stud type units supplied with 3/8″-16 hex head nuts with Belleville washers. For single lug connector kits,
order as extra: K3082 (350 kcmil) or K3441 (600 kcmil). For twin lug connectors order as extra: K3442 (350 kcmil). Separate
kits are required for both line and load.

21
20 AMP—4,5,6,7,8 & 13 TERMINAL—TRANSFORMER RATED
RINGLESS—RING TYPE—600 VAC

1 2

3 4 5
6
Block Assembly for UC7545
(Prefix “UC” designates
sleeve connector for
#4 wire maximum) UC7545-RL

RINGLESS—PLUNGER TYPE BYPASS

NO. DIMENSIONS CONCENTRIC K.O.’S


METER CATALOG CONNECTORS BY-
OF HUB
FORM NUMBER CU PASS D″″ W″″ H″″ 1 2 3 4 5 6
TERMS
4 1S / 2S UC1288-RL H.O. #14 - #4 MAX YES 35⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4
5
5 3S UC1290-RL H.O. #14 - #4 MAX YES 3 ⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4
6 4S UC1299-RL H.O. #14 - #4 MAX YES 35⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4
7,14,15 & 5
7 24S UC7233-RL H.O. #14 - #4 MAX YES 3 ⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4
8 5S UC7235-RL H.O. #14 - #4 MAX YES 35⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4
6,8,9S & 5
13 (ALT) 10S UC7237-RL H.O. #14 - #4 MAX YES 3 ⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4

RING TYPE—PLUNGER TYPE BYPASS

NO. DIMENSIONS CONCENTRIC K.O.’S


METER CATALOG CONNECTORS BY-
OF HUB
FORM NUMBER CU PASS D″″ W″″ H″″ 1 2 3 4 5 6
TERMS
5
4 1S / 2S UC1289-RL H.O. #14 - #4 MAX YES 3 ⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4
5 3S UC1291-RL H.O. #14 - #4 MAX YES 35⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4
5
6 4S UC1300-RL H.O. #14 - #4 MAX YES 3 ⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4
7,14,15 &
7 24S UC7546-RL H.O. #14 - #4 MAX YES 35⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4
5
8 5S UC7544-RL H.O. #14 - #4 MAX YES 3 ⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4
6,8,9S &
13 (ALT) 10S UC7545-RL H.O. #14 - #4 MAX YES 35⁄16 8 14 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1
⁄4

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Plunger type bypass automatically closes when meter is removed.
CONNECTORS: Units are supplied with sleeve type connectors (#4 max.) If compression type connectors (#10) are pre-
ferred, change the catalog prefix to “S” (i.e. UC1289-XL becomes S1289-XL.) The “S” prefix also designates non-U/L.
SERVICE: Units are rated for overhead or underground service.

22
20 AMP—5,6,8 & 13 TERMINAL—TRANSFORMER RATED
RINGLESS / RING TYPE—WITH TEST SWITCH PROVISION—600 VAC

1 2

3 4 5
6

UC7449-XL UC7532-RL-TS10-0109 UC7478-YL


 (shown prewired with
Milbank Test Switch)

1 PIECE COVER—RINGLESS—WITH TEST SWITCH PROVISION *

NO. DIMENSIONS CONCENTRIC K.O.’S


METER CATALOG CONNECTORS BY-
OF HUB
FORM NUMBER CU PASS D″″ W″″ H″″ 1 2 3 4 5 6
TERMS
5 3S UC7442-RL H.O. #14 - #4 MAX NONE 41⁄8 12 20 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1 1
⁄ ⁄
4, 2

6 4S UC7478-RL H.O. #14 - #4 MAX NONE 1 1 1 1 1 1 1 1


4 ⁄8 12 20 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 ⁄ ⁄
4, 2

8 5S UC7444-RL H.O. #14 - #4 MAX NONE 41⁄8 12 20 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1 1
⁄ ⁄
4, 2

6, 8, 9 & 1 1 1 1 1 1 1 1
13 (ALT) 10S
UC7445-RL H.O. #14 - #4 MAX NONE 4 ⁄8 12 20 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 ⁄ ⁄
4, 2

2 PIECE COVER—RINGLESS & RING TYPE—WITH TEST SWITCH PROVISION *

NO. RINGLESS RING TYPE DIMENSIONS CONCENTRIC K.O.’S


CONNECTORS BY-
OF CATALOG CATALOG HUB
CU PASS D″″ W″″ H″″ 1 2 3 4 5 6
TERMS NUMBER NUMBER
5 UC7446-RL UC7450-RL H.O. #14 - #4 MAX NONE 41⁄8 12 20 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1 1
⁄ ⁄
4, 2

6 UC7532-RL UC7636-RL H.O. #14 - #4 MAX NONE 1 1 1 1 1 1 1 1


4 ⁄8 12 20 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 ⁄ ⁄
4, 2

8 UC7448-RL UC7460-RL H.O. #14 - #4 MAX NONE 41⁄8 12 20 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1 1
⁄ ⁄
4, 2

13 UC7449-RL UC7461-RL H.O. #14 - #4 MAX NONE 1 1 1 1 1 1 1 1


4 ⁄8 12 20 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 ⁄ ⁄
4, 2

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
SEALING RINGS: Ring type units are supplied with one MR-2, snap type, sealing ring.
PREWIRING: If standard factory pre-wiring is required, refer to wiring diagrams in the general engineering section of this cata-
log. Determine appropriate diagram and send copy with order. If custom factory prewiring is required, specify on order. Be sure
to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a
copy of your wiring diagram.
CONNECTORS: Units are supplied with sleeve type connectors (#4 max.) If compression type connectors (#10) are preferred,
change catalog prefix to “S” (i.e. UC7445-XL becomes S7445-XL.) The “S” prefix also designates non-U/L.
*TEST SWITCH COVER: Units on this page are not designed for use with test switch covers—see next page.
SERVICE: Units are rated for overhead or underground service.

23
20 AMP—5,6,8, 13 & 15 TERMINAL—TRANSFORMER RATED
TEST SWITCH PROVISION—RINGLESS / RING TYPE—600VAC

1 2 1 1 2

3423 3435
3425 3436
3 4 5 3426 3 4 5 3438
6
3428 3433
3434

UC3423-DL UC3428-DL

2 PIECE COVER—RINGLESS—WITH PROVISION FOR TEST SWITCH

NO. DIMENSIONS CONCENTRIC K.O.’S


SERVICE CATALOG CONNECTORS BY-
OF HUB
NUMBER CU PASS D″″ W″″ H″″ 1 2 3 4 5 6
TERMS
5 OH / UG UC3425-XL C.P. #14 - #4 MAX NONE 1 1 1 1 1 1 1 1
5 ⁄8 12 20 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 ⁄ ⁄
4, 2

6 OH / UG UC3426-XL C.P. #14 - #4 MAX NONE 51⁄8 12 20 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1 1
⁄ ⁄
4, 2

8 OH / UG UC3428-XL C.P. #14 - #4 MAX NONE 1 1 1 1 1 1 1 1


5 ⁄8 12 20 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 ⁄ ⁄
4, 2

13 OH / UG UC3423-XL C.P. #14 - #4 MAX NONE 51⁄8 12 20 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1 1
⁄ ⁄
4, 2

2 PIECE COVER—RING TYPE—WITH PROVISION FOR TEST SWITCH

NO. DIMENSIONS CONCENTRIC K.O.’S


SERVICE CATALOG CONNECTORS BY-
OF HUB
NUMBER CU PASS D″″ W″″ H″″ 1 2 3 4 5 6
TERMS
5 OH / UG UC3435-XL C.P. #14 - #10 MAX NONE 1 —
5 ⁄8 12 20 2 2 2 2 2
6 OH / UG UC3436-XL C.P. #14 - #10 MAX NONE 51⁄8 12 20 2 2 2 2 2 —

8 OH / UG UC3438-XL C.P. #14 - #10 MAX NONE 1 —


5 ⁄8 12 20 2 2 2 2 2
13 OH / UG UC3433-XL C.P. #14 - #10 MAX NONE 51⁄8 12 20 2 2 2 2 2 —

15 OH / UG UC3434-XL C.P. #14 - #10 MAX NONE 1 —


5 ⁄8 12 20 2 2 2 2 2
SEALING RINGS: Ring type units are supplied with one MR-4, screw type, sealing ring.
PREWIRING: If standard factory pre-wiring is required, refer to wiring diagrams in the general engineering section of this cata-
log. Determine appropriate diagram and send copy with order. If custom factory prewiring is required, specify on order. Be
sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to pro-
vide a copy of your wiring diagram.
TEST SWITCH COVERS: Units on this page can be used with clear lexan cover. See next page for ordering information.
CONNECTORS: Units are supplied with sleeve type connectors (#4 max.) If compression type connectors (#10) are preferred,
change catalog prefix to “S” (i.e. UC3434-XL becomes S3434-XL.) The “S” also designates non-U/L.
2 POSITION: Two position units are available. Contact factory.

24
TEST SWITCHES—4, 7 & 10 POLE

Per
ANSI C12.9
Standard

3 1/2"

7 1/2"
CATALOG
NUMBER 4-POLE
7-POLE & 4-POLE BASE
TS04-0101 X P Pn X C+ C X

TS04-0102 X P C+ C X Pn X
TS04-0103 X P Pn X C C+ X
3 1/2"
TS04-0104 X C+ C X P Pn X

CATALOG 9 1/2"
NUMBER 7-POLE
TS07-0105 P P Pn C+ C C+ C 10-POLE BASE
TS07-0106 P C+ C P C+ C Pn

TS07-0107 P P Pn C C+ C C+

TS07-0108 C+ C C+ C P P Pn
KEY
P Potential Switch
CATALOG Line side current switch with
C+
NUMBER 7-POLE ON A 10 POLE BASE short circuit assembly
C Load side current switch with
test jack assembly
TS07-0049 P X P X Pn X C+ C C C+
N Neutral bar ( no switch )
TS07-0018 P X P X Pn X C+ C C+ C
Pn Neutral potential switch
TS07-0059 X P C+ C P C C+ Pn X X
X Unused position on base
TS07-0022 P X P X Pn X C C+ C C+ Insulating barrier, isolates both
sides of switch

CATALOG CUSTOM POLE ARRANGEMENTS:


NUMBER 10-POLE The key may be used to diagram your
own pole arrangement. Be sure to
specify base size and whether all C+
TS10-0109 P P P Pn C+ C C+ C C+ C
line side, current switch / shunt circuit
TS10-0110 P C+ C P C+ C P C+ C Pn assemblies are to be bussed together.
The catalog numbers shown above are
TS10-0111 P P P Pn C C+ C C+ C C+ connected in line-load pairs; therefore,
if bussed is required, different catalog
TS10-0112 C+ C C+ C C+ C P P P Pn
numbers will apply.

TEST SWITCH COVER: For a factory installed, clear test switch cover, add suffix “-WC” (with cover) to the catalog num-
ber. To order covers separately, order catalog number K3388—kit includes mounting hardware. Cover fits 10 pole base
only. Cover can be used with units on preceeding page only.

25
400 AMP—6, 8 & 13 TERMINAL—TRANSOCKET FOR USE WITH BAR TYPE CT’S

U2161-XT-TS10-9586
(Shown with test switch. Order as extra.)
U2161-XT

TRANS-S-PACK
UNITS PRICED WITHOUT TRANS-
FORMERS OR TEST SWITCH.
FOR USE
WITH
CONTACT GENERAL OFFICE FOR
BAR TYPE
ORDERING INFORMATION.
C.T.'S
1 1 2
200 / 5
300 / 5
400 / 5
3 4

5
3 5 4 5

400 AMP–6,8 &13 TERMINAL–TRANS-S-PACK–RINGLESS

METER NO. TRF. DIMENSIONS CONCENTRIC K.O.’S


CATALOG HUB CONNECTORS
FORM OF MTGS.
NUMBER D″″ W″″ H″″ 1 2 3 4 5
TERM.
1/2″-13
4S 6 U2228-XT (2) C.P. 500 kcmil TWIN STUDS
12 24 36 4 4 4 4 1
1/2″-13
5S 8 U2229-XT (2) C.P. 500 kcmil TWIN STUDS
12 24 36 4 4 4 4 1
1/2″-13 7
6,8,9S 13 U2161-XT (2) C.P. 500 kcmil TWIN STUDS
12 33 ⁄16 36 4 4 4 4 1

HUBS: Units are supplied with two closing plates as standard. To order hubs as extra refer to the Hub Suffix chart on the acces-
sory page.
STUDS: 1/2″-13 twin studs are supplied to mount bar type transformers. Hex nuts with Belleville washers are also supplied.
PREWIRING: If standard factory prewiring is required, refer to wiring diagrams in the general engineering section. Determine
appropriate diagram and send copy with order. If custom factory prewiring is required, be sure to specify test switch catalog
number, meter form number and provide a copy of your wiring diagram. If C.T.’s are to be factory installed, specify C.T. ratio.
There is no provision for P.T.’s in this unit. Contact factory for pricing.

26
600 AMP—6, 8,13 & 14 TERMINAL
COMMERCIAL TRANSOCKET, P.T.’S, DONUT OR BAR TYPE C.T.’S—600 VAC

S1890-XT S2690-XT
S2690-XT

5 1 1

1 1 2 1 1 2
1891 3831
3912 2690
4 3 4 3 4 1890 4 3 4 3 4 2674

600 AMP / 600 VOLT—WITH P.T.’S AND DONUT TYPE C.T.’S—RINGLESS

METER NUMBER CATALOG P.T.’S C.T.’S DIMENSION CONCENTRIC K.O.’S


OF HUB QTY. QTY.
FORM NUMBER
TERMS. & RATIO & RATIO D″″ W″″ H″″ 1 2 3 4 5
1 1 1 1 11
5S 8 S1891-XT (2)C.P. (2) 4:1 (2) 200/5 9 ⁄2 18 24 2 ⁄2 2 ⁄2 2 ⁄2 1 ⁄16
1 1 1 1 11
6S 13 S3912-XT (2)C.P. (2) 2.5:1 (3) 200/5 9 ⁄2 18 24 2 ⁄2 2 ⁄2 2 ⁄2 1 ⁄16
1 1 1 1 11
6S 14 S1890-XT (2)C.P. (2) 2.5:1 (3) 200/5 9 ⁄2 18 24 2 ⁄2 2 ⁄2 2 ⁄2 1 ⁄16

600 AMP / 600 VOLT—BAR TYPE C.T.’S ONLY—RINGLESS

METER NUMBER CATALOG C.T. C.T.


DIMENSION CONCENTRIC K.O.’S
OF HUB
FORM NUMBER QTY. RATIO
TERMS. D″″ W″″ H″″ 1 2 3 4
1 1 1
4S 6 S3831-XT (2)C.P. 2 200/5 11 ⁄4 18 30 3 ⁄2 3 ⁄2 4 1
1 1 1
5S 8 S2690-XT (2)C.P. 2 200/5 11 ⁄4 18 30 3 ⁄2 3 ⁄2 4 1
1 1 1
8S 13 S2674-XT (2)C.P. 3 200/5 11 ⁄4 18 30 3 ⁄2 3 ⁄2 4 1

HUBS: Units supplied with two closing plates as standard. To order hubs as extra, refer to the Hub suffix chart on the
Accessory page.
PREWIRING: Units supplied prewired with test switch and transformers in place. Contact factory if wiring diagram is desired.
PRICING: Contact general office for pricing information.
U/L LABEL: Contact general office for ordering information if “UL” label is required.

27
1600 AMP—MAXI-TRANSOCKET WITH P.T.’S AND BAR TYPE C.T.’S—480 VAC

S2777-4X S2777-4X

1 2 3 4

∅4W
1600 AMP—WITH P.T.’S AND BAR TYPE C.T.’S—RINGLESS—3∅

METER NUMBER CATALOG P.T.’S C.T.’S DIMENSION CONECNTRIC K.O.’S


OF HUB QTY. QTY.
FORM NUMBER
TERMS. & RATIO & RATIO D″″ W″″ H″″ 1 2 3 4
1 1 1 1
6S 14 S2777-4X (4)C.P. (2) 2.5:1 (3) 400/5 14 30 42 ⁄2 ⁄2 ⁄2 ⁄2
1 1 1 1
8S 14 S2811-4X (4)C.P. NONE (3) 400/5 14 30 42 ⁄2 ⁄2 ⁄2 ⁄2

HUBS: Units supplied with 4 closing plates as standard. To order hubs as extra refer to the hub suffix chart on the
accessory page.
PREWIRING: Units supplied with test switch and transformers in place. Contact factory if wiring diagram is desired.
PRICING: Contact general office for pricing information.
U/L LABEL: Contact general office for ordering information if “UL” label is required.

28
OUTDOOR TRANSFORMER CABINETS—NEMA 3R

WALL
OR POLE MOUNT
C.T. RACK
S7860

231⁄2″

S7860
S9690
13″

OUTDOOR TRANSFORMER CABINETS*—NEMA 3R

DIMENSIONS GAUGE OF BOARD SIZE


CATALOG NUMBER
D″″ W″″ H″″ STEEL W″″ H″″
S4017-O 8 24 18 14 22 12
S4019-O 10 32 24 14 30 18
S4020-O 10 36 32 14 34 26
S9690-O 13 24 24 16 22 18
S9691-O 13 30 30 16 28 24
S9692-O * 13 36 36 16 34 30
S9693-O * 13 30 40 14 28 34
S9694-O * 13 34 46 14 32 40
S9695-O * 13 40 48 14 38 42
FEATURES: Supplied with solid back board, three point locking handle, lift off hinges with stainless steel pins and
pad-lock provisions. * Double Door Units.

U/L LISTED—OUTDOOR TRANSFORMER CABINETS*—CONTINUOUS HINGE—NEMA 3R— 

DIMENSIONS GUAGE PANEL SIZE PANEL & BACKBOARD CATALOG NUMBERS


CATALOG
OF
NUMBER
D″″ W″″ H″″ STEEL W″″ X H″″ PAINTED STEEL PANEL WOOD BACKBOARD
243210-CT3R 10 24 32 14 21 29 M-24P32 M-24P32W
243610-CT3R 10 24 36 14 21 33 M-36P24 M-36P24W
303610-CT3R 10 30 36 14 27 33 M-36P30 M-36P30W
304010-CT3R 10 30 40 14 27 37 M-30P40 M-30P40W
323610-CT3R 10 32 36 14 29 33 M-32P36 M-32P36W
443010-CT3R ** 10 44 30 14 41 27 M-30P44 M-30P44W
303612-CT3R 12 30 36 14 27 33 M-36P30 M-36P30W
363612-CT3R ** 12 36 36 14 33 33 M-36P36 M-36P36W
423012-CT3R ** 12 42 30 14 39 27 M-42P30 M-42P30W
483612-CT3R ** 12 48 36 14 45 33 M-48P36 M-48P36W
484812-CT3R ** 12 48 48 14 45 45 M-48P48 M-48P48W
363016-CT3R ** 16 36 30 14 33 27 M-36P30 M-36P30W
423616-CT3R ** 16 42 36 14 39 33 M-42P36 M-42P36W
FEATURES: Supplied with studs, three point locking handle, continuous hinge and pad-lock provision. Single door provided on
units less than 36″ wide. Steel panels and plywood backboard are optional. For additional metal backboards add the appropri-
ate suffix to the end of the catalog number; “A” for aluminum, “S” for 304 stainless steel, or “Z” for 316 stainless steel.
C.T. MOUNTING RACK: For wall or pole mount C.T. rack order S7860. This unit accommodates 3 donut style C.T.s.
Removable cover makes wiring a breeze.
* NOTE: There are other sizes of Outdoor Transformer Cabinets available. Please refer to the Milbank Electrical Enclosure
Catalog featuring Nema Rated Sheetmetal Products. ** Double Door Units.

29
100 AMP / POSITION—4 & 5 TERMINAL—VERTICAL GANGS—RINGLESS—300 VAC

1 1 2

3 4 5
6

U2692-XL

100 AMP / POSITION—4 TERMINAL—RINGLESS

NO. CONNECTORS
CATALOG CU/AL BY- DIMENSIONS CONCENTRIC K.O.’S
OF SERVICE HUB
PASS D″″ W″″ H″″
NUMBER LINE LOAD 1 2 3 4 5 6
POS
1 1 1 1 1 1 1 1
2 OH/UG U2692-RL H.O. #2-350 kcmil #6-2/0 NONE 4 ⁄8 8 25 ⁄4 1 ⁄2 1 ⁄2 1 ⁄4 2 ⁄2 1 ⁄2 ⁄4
1 3 1 1 1 1 1 1
3 OH/UG U2693-RL H.O. #2-350 kcmil #6-2/0 NONE 4 ⁄8 8 35 ⁄4 1 ⁄2 1 ⁄2 1 ⁄4 2 ⁄2 1 ⁄2 ⁄4

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
FIFTH TERMINAL: For a field mounted fifth terminal, order catalog number 5T8K2.
CONNECTORS: Extruded aluminum connectors are tin plated.
BUSSING: 1/4 x 1″ aluminum bussing is supplied. Refer to general engineering section for information on ampacity of bus.

30
100 AMP / POSITION—4 TERMINAL
HORIZONTAL GANGS—RINGLESS—300 VAC

U8212-RL U7363-RL

1 1 2 1 1 2

8212-6 7362-6
3 4 3 3
4 5
3 5
4

4 “ SIDE WIREWAY FOR OVERHEAD


OH/UG SERVICE SERVICE ONLY

∅3W
100 AMP / POSITION— 4 TERMINAL—RINGLESS—1∅
NO. CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
SERVICE OF HUB
NUMBER PASS
POS. LINE LOAD D″″ W″″ H″″ 1 2 3 4 5
#2-350 5 1
OH/UG 2 U8212-RL H.O. kcmil
#6-2/0 NO 41⁄2 20 ⁄16 16 2 2 2 21⁄2 ⁄4,1⁄2
#2-350 1
OH/UG 3 U8213-RL H.O. kcmil
#6-2/0 NO 41⁄2 281⁄2 16 2 2 2 21⁄2 ⁄4,1⁄2
#2-350 1
OH/UG 4 U8214-RL H.O. kcmil
#6-2/0 NO 41⁄2 4011⁄16 16 2 2 2 21⁄2 ⁄4,1⁄2
#2-350 1
OH/UG 5 U8215-RL H.O. kcmil
#6-2/0 NO 41⁄2 487⁄8 16 2 2 2 21⁄2 ⁄4,1⁄2
#2-350 1
OH/UG 6 U8216-RL H.O. kcmil
#6-2/0 NO 41⁄2 571⁄16 16 2 2 2 21⁄2 ⁄4,1⁄2
#2-350 1
OH 2 U7362-RL H.O. kcmil
#6-2/0 NO 41⁄2 165⁄16 16 2 2 2 ⁄4,1⁄2 –
#2-350 1 1
OH 3 U7363-RL H.O. kcmil
#6-2/0 NO 41⁄2 241⁄2 16 2 2 2 ⁄4, ⁄2 –
#2-350 1
OH 4 U7364-RL H.O. kcmil
#6-2/0 NO 41
⁄2 32 ⁄16 16
11
2 2 2 ⁄4,1⁄2 –
#2-350 1
OH 5 U7365-RL H.O. kcmil
#6-2/0 NO 41⁄2 407⁄8 16 2 2 2 ⁄4,1⁄2 –
#2-350 1
OH 6 U7366-RL H.O. kcmil
#6-2/0 NO 41⁄2 491⁄16 16 2 2 2 ⁄4,1⁄2 –
HUB: For proper hub selection refer to the hub suffix chart on the accessory page. Hub opening is supplied at each end.
Extra opening is closed with a closing plate as standard.
FIFTH TERMINAL: For factory installed fifth terminal in the 6 o’clock position add the suffix “-5T”. For field mounted fifth
terminal, order catalog number 5T8K2.
CONNECTORS: Extruded aluminum connectors are tin plated.
BYPASS: Horn type bypass is available. Add suffix “-KK” to catalog number.
BUSSING: Bussing is 5/16″ x 1″ aluminum. Refer to the general engineering section for information on ampacity of
bussing.

31
100 & 125 AMP / POSITION—4 TERMINAL
HORIZONTAL GANGS—RINGLESS—300 VAC

U8032-RL

CENTER
WIREWAY
1 1 1 2 1 1 2

8032-6 9652-6
7 4 7 3 7 4 7 4 4 4
6 5 5 6  5 5

∅3W
100 & 125 AMP / POSITION—4 TERMINAL—RINGLESS—OH/UG—1∅
NO. CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
AMPS OF HUB
NUMBER PASS
POS. LINE LOAD D″″ W″″ H″″ 1 2 3 4 5 6 7
#2-350 1 1 1 1 1 5
100 2 U8032-RL H.O. kcmil
#6-2/0 NO 41⁄2 24 ⁄2 16 2 2 21⁄2 2 ⁄4, ⁄2 ⁄4, ⁄2 ⁄16
#2-350 1 1 1 1 5
100 3 U8033-RL H.O. kcmil
#6-2/0 NO 4 1
⁄2 32 ⁄16 16
11
2 2 21⁄2 2 ⁄4, ⁄2 ⁄4, ⁄2 ⁄16
#2-350 1 1 1 1 5
100 4 U8034-RL H.O. kcmil
#6-2/0 NO 41⁄2 40 7
⁄8 16 2 2 21⁄2 2 ⁄4, ⁄2 ⁄4, ⁄2 ⁄16
#2-350 1 1 1 1 1 5
100 5 U8035-RL H.O. kcmil
#6-2/0 NO 4 1
⁄2 49 ⁄16 16 2 2 21⁄2 2 ⁄4, ⁄2 ⁄4, ⁄2 ⁄16
#2-350 1 1 1 1 5
100 6 U8036-RL H.O. kcmil
#6-2/0 NO 41⁄2 57 1
⁄4 16 2 2 21⁄2 2 ⁄4, ⁄2 ⁄4, ⁄2 ⁄16
#2-350 1 1
125 2 U9652-XL-350 C.P. kcmil
#6-2/0 NO 4 1
⁄2 24 ⁄2 16
1
11 ⁄2 11⁄2 – 21⁄2 ⁄4, ⁄2 – –
#2-350 1 1
125 3 U9653-XL-350 C.P. kcmil
#6-2/0 NO 41⁄2 3211⁄16 16 11⁄2 11⁄2 – 21⁄2 ⁄4, ⁄2 – –
#2-350 1
125 4 U9654-XL-350 C.P. kcmil
#6-2/0 NO 4 1
⁄2 40 ⁄8 16
7
11 ⁄2 11⁄2 – 21⁄2 ⁄4,1⁄2 – –
#2-350
125 5 U9655-XL-K9* C.P. kcmil
#6-2/0 NO 41⁄2 491⁄16 16 11⁄2 11⁄2 – 21⁄2
1
⁄4,1⁄2 – –
#2-350 1
125 6 U9656-XL-K9* C.P. kcmil
#6-2/0 NO 41⁄2 571⁄4 16 11⁄2 11⁄2 – 21⁄2 ⁄4,1⁄2 – –
HUB: For proper hub selection refer to the hub suffix chart on the accessory page.
FIFTH TERMINAL: For factory installed fifth terminal add the suffix “-5T”. For field mounted fifth terminal, order catalog number
5T8K2. Fifth terminal will be in the 6 o’clock position on the 8032 series and in the 9 o’clock position on the 9652 series.
CONNECTORS: Extruded aluminum connectors are tin plated.
BYPASS: Horn type bypass is available. Add suffix “-KK” to catalog number.
BUSSING: Bussing is 5/16″ x 1″ aluminum. Refer to general engineering section for information on ampacity of bussing.
*FOR OVERHEAD SERVICE: The 9655 and the 9656 units are factory assembled for underground service. If overhead service
is desired an extension kit is required; order catalog number K3797.

32
150 & 200 AMP / POSITION—4 TERMINAL
HORIZONTAL GANGS—RINGLESS—300 VAC

U9352-RL  U1252-X-K1

1 1 2
1 1 1 1 1 1 1

4
9352-6 3 2 3 1252-3 3 2 2 3 3 1254-6
3 6
5
6 4 5 4 4 6 5 4 4
6

∅3W—OH/UG*
150 & 200 AMP / POSITION—4 TERMINAL—RINGLESS—1∅
NO. CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
AMPS OF HUB
NUMBER PASS
POS. LINE LOAD D″″ W″″ H″″ 1 2 3 4 5 6
#2-350 #2-350 5 1
150 2 U9352-RL H.O. kcmil kcmil
NO 41
⁄2 20 ⁄16 16 2 2 21⁄2 2 2 ⁄4,1⁄2
#2-350 #2-350 1
150 3 U9353-RL H.O. kcmil kcmil
NO 41⁄2 281⁄2 16 2 2 21⁄2 2 2 ⁄4,1⁄2
#2-350 #2-350 1
150 4 U9354-RL H.O. kcmil kcmil
NO 41⁄2 4011⁄16 16 2 2 21⁄2 2 2 ⁄4,1⁄2
#2-350 #2-350
150 5 S9355-RL H.O. kcmil kcmil
NO 41⁄2 487⁄8 16 2 2 21⁄2 2 2
1
⁄4,1⁄2
#2-350 #2-350 1
150 6 S9356-RL H.O. kcmil kcmil
NO 41⁄2 571⁄16 16 2 2 21⁄2 2 2 ⁄4,1⁄2
3/8″-16 #2-350 1 1
200 2 U1252-X C.P. STUD kcmil
NO 51⁄8 261⁄2 14 21⁄2 3 21⁄2 ⁄2 ⁄4 1
3/8″-16 #2-350 1 1
200 3 U1253-X C.P. STUD kcmil
NO 51
⁄8 34 ⁄16 14
11
21⁄2 3 21⁄2 ⁄2 ⁄4 1
3/8″-16 #2-350 1 1
200 4 U1254-X C.P. STUD kcmil
NO 51
⁄8 42 ⁄8 16
7
21⁄2 3 21 ⁄2 ⁄2 ⁄4 1
3/8″-16 #2-350 7 1 1
200 5 U1255-X C.P. STUD kcmil
NO 51
⁄8 54 ⁄8 16 21⁄2 3 21⁄2 ⁄2 ⁄4 1
3/8″-16 #2-350 1 1
200 6 U1256-X C.P. STUD kcmil
NO 51
⁄8 63 ⁄16 18
1
21⁄2 3 21 ⁄2 ⁄2 ⁄4 1
HUB: For proper hub selection refer to the hub suffix chart on the accessory page. For the 9352-9356 units, as well as
the 1255-1256 units, two hub openings are supplied and the extra opening is closed with a closing plate as standard.
FIFTH TERMINAL: For factory installed fifth terminal in the 6 o’clock position add the suffix “-5T”. For field mounted fifth
terminal, order catalog number 5T8K2.
CONNECTORS: Extruded aluminum connectors are tin plated.
BYPASS: Horn type bypass is available. Add suffix “-KK” to catalog number.
BUSSING: Bussing is 5/16″ x 1″ aluminum on the 9352 series and the 1252-1253. On the 1254-6 gangs the bussing is
3/8″ x 1″ aluminum. Refer to general engineering section for information on ampacity of bussing.
NON-U/L LISTED: The S9355 and S9356 units are non-U/L. For U/L listed units see other choices on this page.
*FOR OVERHEAD SERVICE: The 1254, 1255 and 1256 units are factory assembled for underground service. If over-
head service is desired an extension kit is required. Order catalog number K3923 for the 1254 and 1255 units and K3955
for the 1256 unit. For factory installed overhead service add the suffix “-EX” to the catalog number.

33
200 AMP / POSITION—5 & 7 TERMINAL—HORIZONTAL GANGS
JAW CLAMPING LEVER—RINGLESS—600 VAC

1 1 1 2

2872-6
4 3 3 4 2732-6
5

CENTER WIREWAY

U2732-XT

∅3W
200 AMP —5 TERMINAL—RINGLESS—1∅
NO. CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
AMPS SERV. OF HUB
NUMBER
POS. LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5
3/8″-16 #6-350
200 OH/UG 2 U2872-XT (2)C.P. LEVER 6 321⁄8 251⁄4 21⁄2 21⁄2 4 21⁄2 1 1
⁄ ⁄
4, 2
STUD kcmil
3/8″-16 #6-350
200 OH/UG 3 U2873-XT (2)C.P. LEVER 6 423⁄16 251⁄4 21⁄2 21⁄2 4 21⁄2 1 1
⁄ ⁄
4, 2
STUD kcmil
3/8″-16 #6-350
200 OH/UG 4 U2874-XT (2)C.P. LEVER 6 521 ⁄4 251 ⁄4 21 ⁄2 21 ⁄2 4 21⁄2 1 1
⁄ ⁄
4, 2
STUD kcmil
3/8″-16 #6-350
200 OH/UG 5 U2875-XT (2)C.P. LEVER 6 625⁄16 251⁄4 21⁄2 21⁄2 4 21⁄2 1 1
⁄ ⁄
4, 2
STUD kcmil
3/8″-16 #6-350
200 OH/UG 6 U2876-XT (2)C.P. LEVER 6 723 ⁄8 311 ⁄4 21 ⁄2 21 ⁄2 4 21⁄2 1 1
⁄ ⁄
4, 2
STUD kcmil

∅4W
200 AMP —7 TERMINAL—RINGLESS—3∅
NO. CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
AMPS SERV. OF HUB
NUMBER PASS
POS. LINE LOAD D″″ W″″ H″″ 1 2 3 4 5
3/8″-16 #6-350
200 OH/UG 2 U2732-XT (2)C.P.
STUD kcmil
LEVER 6 321⁄8 251⁄4 21⁄2 21⁄2 4 21⁄2 1 1
⁄ ⁄
4, 2
3/8″-16 #6-350
200 OH/UG 3 U2733-XT (2)C.P.
STUD kcmil
LEVER 6 423⁄16 251⁄4 21⁄2 21⁄2 4 21⁄2 1 1
⁄ ⁄
4, 2
3/8″-16 #6-350
200 OH/UG 4 U2734-XT (2)C.P.
STUD kcmil
LEVER 6 521 ⁄4 251 ⁄4 21 ⁄2 21 ⁄2 4 21 ⁄2 1 1
⁄ ⁄
4, 2
3/8″-16 #6-350
200 OH/UG 5 U2735-XT (2)C.P.
STUD kcmil
LEVER 6 625⁄16 251⁄4 21⁄2 21⁄2 4 21⁄2 1 1
⁄ ⁄
4, 2
3/8″-16 #6-350
200 OH/UG 6 U2736-XT (2)C.P.
STUD kcmil
LEVER 6 723 ⁄8 311 ⁄4 21 ⁄2 21 ⁄2 4 21 ⁄2 1 1
⁄ ⁄
4, 2

HUBS: Units supplied with two closing plates. To order hubs as extra refer to the hub suffix chart on the Accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
*CONNECTOR KITS: Line wire sections supplied with studs. For connector kits for the 2872-6 units, order as extra: K1539
(350kcmil), K1540 (600kcmil) or twin K1541 (600kcmil.) For 2732-6 units order K3082 (350kcmil), K3441 (600kcmil) or twin
K3083 (600kcmil.) Line connectors can be reversed to change from “OH” to “UG” service.
BUSSING: Bussing is 3/8″ x 1″ aluminum. Refer to general engineering section for information on ampacity of bussing.

34
100 & 200 AMP / POSITION—4 TERMINAL
HORIZONTAL GANGS—RINGLESS—120/240 VAC

SUPPLIED WITH OR WITHOUT BREAKERS

FACTORY
PREWIRED

H″
1 1 1

CB″
2 2 2

7 3 4 7 8032
4 7 7
Bottom
6 5 5 6

4 6 3 4 1252
5 7 6 Bottom

S1252-X-CB-200

*100 AMP— GANG SOCKET—4 TERMINAL—RINGLESS—BREAKERS NOT INCLUDED—OH/UG


NO. CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
AMPS OF HUB
NUMBER PASS
POS. LINE LOAD CB″″ D″″ W″″ H″″ 1 2 3 4 5 6 7
#2-350
100 2 S8032-XL-CB C.P. kcmil — NONE 10 41⁄2 41⁄8 26 2 11⁄2 21⁄2 2
1 1
⁄ ⁄
4, 2
1 1
⁄ ⁄
4, 2
5
⁄16
#2-350 1 1 1 1 5
100 3 S8033-XL-CB C.P. kcmil — NONE 10 4 1
⁄2 32 ⁄16 26
11
2 11⁄2 21⁄2 2 ⁄ ⁄
4, 2 ⁄ ⁄
4, 2 ⁄16
#2-350 1 1 1 1 5
100 4 S8034-XL-CB C.P. kcmil — NONE 10 41⁄2 407⁄8 26 2 11⁄2 21⁄2 2 ⁄ ⁄
4, 2 ⁄ ⁄
4, 2 ⁄16
#2-350 1 1 1 1 1 5
100 5 S8035-XL-CB C.P. kcmil — NONE 10 4 1
⁄2 49 ⁄16 26 2 11⁄2 21⁄2 2 ⁄ ⁄
4, 2 ⁄ ⁄
4, 2 ⁄16
#2-350 1 1 1 1 5
100 6 S8036-XL-CB C.P. kcmil — NONE 10 41⁄2 571⁄4 26 2 11⁄2 21⁄2 2 ⁄ ⁄
4, 2 ⁄ ⁄
4, 2 ⁄16
NOTE: The 8032 series takes plug-in breakers. Order as extra. Units are factory wired from load side meter to plug-in
breaker panel.

*200 AMP— GANG SOCKET—SUPPLIED WITH 200 AMP BOLT-ON BREAKER PER POSITION—OH/UG**
NO. CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
AMPS OF HUB
NUMBER PASS
POS. LINE LOAD CB″″ D″″ W″″ H″″ 1 2 3 4 5 6 7
3/8″-16
200 2 S1252-X-CB200 C.P. STUD — NONE 14 51⁄8 261⁄2 28 21⁄2 2 3 21⁄2
1
⁄4 1
⁄2 1
3/8″-16 1 1
200 3 S1253-X-CB200 C.P. STUD — NONE 14 51
⁄8 34 ⁄16 28
11
21⁄2 2 3 21⁄2 ⁄4 ⁄2 1
3/8″-16 1 1
200 4 S1254-X-CB200 C.P. STUD — NONE 14 51⁄8 427⁄8 30 21⁄2 2 3 21⁄2 ⁄4 ⁄2 1
3/8″-16 7 1 1
200 5 S1255-X-CB200 C.P. STUD — NONE 14 51
⁄8 54 ⁄8 30 21⁄2 2 3 21⁄2 ⁄4 ⁄2 1
3/8″-16 1 1
200 6 S1256-X-CB200 C.P. STUD — NONE 14 51⁄8 631⁄16 32 21⁄2 2 3 21⁄2 ⁄4 ⁄2 1

* See pages 32 and 32 for more information.


NOTE: The 1252 series is factory prewired from load side meter to “bolt-on” 200 AMP breaker which is factory installed.
(150 AMP also available.)
FIFTH TERMINAL: For field mounted fifth terminal, order catalog number 5T8K2 (mount in 9 o’clock position for 200 AMP and 6
o’clock position for 100 AMP.)
**FOR OVERHEAD SERVICE: The 1254, 1255 & 1256 units are factory assembled for underground service. For overhead ser-
vice an extension kit is required. Order as extra, K3923 for the 1254 and 1255 units, and K3955 for the 1256 unit.
BYPASS: Horn type bypass is available. Add suffix “-KK” to catalog number.
U/L LISTING: Units on this page are not U/L listed. If listing is required, refer to choices on following pages.

35
∅3W—120/240 VAC
CONDOMINIUM METERING BANKS—1∅

U2854-X-4/125
 (Order circuit breakers as extra)
U2866-X

125 AMP/POSITION
VERTICAL 200 AMP/POSITION
NO. LINE NO. LINE
CATALOG MAIN BUS CATALOG MAIN BUS
OF CONNECTOR OF CONNECTOR
NUMBER RATING NUMBER RATING
POS. SIZE POS. SIZE
1 U2351-RXL NOT BUSSED #6-2/0 AWG 1 U2288-RXL NOT BUSSED #6-250 AWG

2 U2852-X 200 AMP. *3/8″-16 STUD 2 U2862-X 250 AMP. *3/8″-16 STUD

3 U2853-X 200 AMP. *3/8″-16 STUD 3 U2863-X 300 AMP. *3/8″-16 STUD

125 AMP/POSITION RECTANGULAR 200 AMP/POSITION


NO. LINE NO. LINE
CATALOG MAIN BUS CATALOG MAIN BUS
OF CONNECTOR OF CONNECTOR
NUMBER RATING NUMBER RATING
POS. SIZE POS. SIZE
4 U2854-X 400 AMP. *3/8″-16 STUD 4 U2864-X 400 AMP. *3/8″-16 STUD

5 U2855-X 400 AMP. *3/8″-16 STUD 5 U2865-X 600 AMP. *3/8″-16 STUD

6 U2856-X 400 AMP. *3/8″-16 STUD 6 U2866-X 600 AMP. *3/8″-16 STUD

CONNECTOR KITS * BREAKER CHART


MURRAY
MILBANK WESTINGHOUSE / ITE CROUSE- G.E. SQUARE-
SIZE SUFFIX KIT COMPATIBLE WIRE AMPS
BRYANT D
HINDS
NUMBER WITH RANGE
125-200 BR / BJ MD Q LINE
U2852-56 #6-350
-K1 K1539
U2862-66 kcmil 125 OR TYPE QUICKLAG P HOME
SINGLE BR QP MP Q LINE LINE
U2854-56 #4-600 LESS UCP
-K3 K1540
U2864-66 kcmil
*CONNECTORS: For line wire connector kits, order
U2854-56 #6-350
-K2 K1350 separately.
U2863-66 kcmil
TWIN FIFTH TERMINALS: For field mounted fifth terminal
#2-600 order catalog number K2381. Order one per meter
-K4 K1541 U2864-66
kcmil position.
BREAKERS: Units have provision for one double
pole main per meter position. Breakers not included.
Order as extra.

36
∅3W—120/240 VAC
CONDOMINIUM METERING BANKS—1∅

VERTICAL
125 &200 AMP/POS. 125 AMP/POS. 200 AMP/POS.
(SINGLE POSITION) (2-3 POSITION) (2-3 POSITION)

D D D

21"

A A
25" or
C C 37" 29" or
B 41"

13" 5 13/16"
or
18"

5 13/16" E E E B C
18"
E E E
B C 5 13/16"
U2852-X
21"

CONDOMINIUM
METERING BANKS RECTANGULAR
125 AMP/POS. 200 AMP/POS.
(4,5 & 6 POSITION) (4,5 & 6 POSITION)

D D

FIG. DIMENSIONS
37" or
25"
A 11⁄4 ″ CONCENTRIC K.O. 29" or
41"

B ⁄4,1⁄2″ CONCENTRIC K.O.


1

C 3″ CONCENTRIC K.O.

D 4″ HUB OPENING A A A
B
C A A A 4 7/8"

31" E E E C E E E 4 7/8"
E 2″ CONCENTRIC K.O. B

36"

37
100, 150 & 200 AMP—4 TERMINAL—METER MAIN
RINGLESS / RING TYPE—120/240 VAC

DIMENSIONS CONCENTRIC K.O.’S

D″″ W″″ H″″ 1 2 3 4 5

41⁄2 14 31 2 2 21⁄2 ⁄4,1⁄2 H.O.


1

 3
2 4 5

U3200-XTL-RL-FIG20
(Shown with extra 100 amp-2 pole breaker)

∅3W
100-200 AMP—4 TERMINAL—RING TYPE AND RINGLESS—1∅

RATING CATALOG CATALOG MAIN PARALLEL EXTRA


AMPS NUMBER NUMBER BREAKER MAIN CIRCUIT
(RING TYPE) (RINGLESS TYPE) SUPPLIED SUPPLIED PROVISION
100 U3200-XTL-RL-FIG1 U3900-XTL-RL-FIG1 100 AMP — 4-branch

150 U3200-XTL-RL-FIG2 U3900-XTL-RL-FIG2 150 AMP — 4-branch

200 U3200-XTL-RL-FIG4 U3900-XTL-RL-FIG4 200 AMP — 4-branch

100 U3200-XTL-RL-FIG5 U3900-XTL-RL-FIG5 — 100 AMP 4-parallel

150 U3200-XTL-RL-FIG6 U3900-XTL-RL-FIG6 — 150 AMP 4-parallel

200 U3200-XTL-RL-FIG8 U3900-XTL-RL-FIG8 — 200 AMP 4-parallel

200 U3200-XTL-RL-FIG9 U3900-XTL-RL-FIG9 — 2/100 AMP 2-parallel

200 U3200-XTL-RL-FIG10 U3900-XTL-RL-FIG10 NOT SUPPLIED WITH BREAKERS 6-parallel

SEALING RINGS: Ring type units are supplied with MR-4, screw type, sealing rings.
FIFTH TERMINAL: For field mounted fifth terminal, order catalog number 5T8K2.
HUBS: Units supplied with two, standard closing plates on top and one, 2″ hub packed inside.
UNDERGROUND PULL SECTION WIREWAY: An underground pull section wireway is provided.
OVERHEAD PULL SECTION BARRIER: An optional overhead pull section barrier is available
upon request; order part Z809223-SC.
BREAKERS: Units which specify factory installed breakers are supplied with double-pole, plug-in
style circuit breakers.

PLUG-IN BREAKER COMPATIBILITY CHART


AMPS MILBANK CUTTLER-HAMMER
(WESTINGHOUSE)
ITE MURRAY /
CROUSE-HINDS
G.E. SQ-D

125-200 — HQP / WBJ — MD Q LINE —


≤ 125 TYPE UCP QUICKLAG P / QP MP Q LINE HOMELINE
HQP

38
100, 150 & 200 AMP—4 TERMINAL—METER SOCKET / CB COMBO
SERVICE EQUIPMENT—RINGLESS—120/240 VAC

1 1 2
5

9274
3 9275
6 4
5 9276

1 5
1 2

9270
4 3 4 9271
5
9328

UAP9276-O UAP9328-RL

4 TERMINAL—RINGLESS—METER SOCKET / CB COMBO—ALUMINUM CONSTRUCTION


CONNECTORS DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
AMPS SERVICE HUB
NUMBER LINE PASS D″″ W″″ H″″ 1 2 3 4 5 6

2″″
1 1
100 OH UAP9270-DL #2-350 kcmil NONE 4 ⁄2 12 ⁄8 26 2 2 21 ⁄2 21 ⁄2 ⁄ ⁄
1 1
4, 2 —
2″″
1 1
150 OH UAP9271-DL #2-350 kcmil NONE 4 ⁄2 12 ⁄8 26 2 2 21 ⁄2 21 ⁄2 ⁄ ⁄
1 1
4, 2 —
2″″
1 1
200 OH UAP9328-DL #2-350 kcmil NONE 4 ⁄2 12 ⁄8 26 2 2 21 ⁄2 21 ⁄2 ⁄ ⁄
1 1
4, 2 —
1 1
100 UG UAP9274-O BLANK #2-350 kcmil NONE 4 ⁄2 14 ⁄8 24 2 2 21⁄2 21⁄2 ⁄ ⁄ H.O.
1 1
4, 2

1 1
150 UG UAP9275-O BLANK #2-350 kcmil NONE 4 ⁄2 14 ⁄8 24 2 2 21 ⁄2 21 ⁄2 ⁄ ⁄ H.O.
1 1
4, 2

1 1
200 UG UAP9276-O BLANK #2-350 kcmil NONE 4 ⁄2 14 ⁄8 24 2 2 21⁄2 21⁄2 ⁄ ⁄ H.O.
1 1
4, 2

HUBS: Underground units are supplied with standard hub opening in bottom. Order hub as extra. Refer to accessory page.
CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral. For triplex ground,
add suffix “-TG” to catalog number.
BUSSING: Factory bussed from load side meter to line side CB section.
STEEL: These units are available in steel. Contact factory for ordering information.
BREAKERS: Breaker section has provision for six double pole “plug-in” type circuit breakers. All circuit breakers will be par-
allel. Refer to the accessory page for more breaker information. To comply with NEC wire bending space requirements the
maximum breaker amperage is 100 Amps. For breaker compatability refer to the breaker compatibility chart in the general
engineering section.

39
100, 150 & 200 AMP—4 TERMINAL—METER MAIN —RINGLESS
WITH LOAD SIDE DISTRIBUTION—120/240 VAC

SUPPLIED WITH BREAKERS

1 2

4 3 4 9647
5 6 9648

S9648-RL-100 U9647-RL-200

∅3W
4 TERMINAL—METER-MAIN—WITH TRIPLE TAP LUGS—RINGLESS—1∅
CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
AMPS SERVICE HUB
NUMBER PASS
LINE LOAD D″″ W″″ H″″ 1 2 3 4 5 6

100 OH S9648-RL-100 H.O. #6-2/0 (3) 1/0 NONE 41⁄8 8 24 — — 21⁄2 1 1
⁄ ⁄
4, 2 21⁄2
#6-350 #6-350
100 OH/UG S9647-RL-100 H.O. kcmil kcmil
NONE 47⁄8 13 32 21⁄2 21⁄2 21⁄2 21⁄2 21⁄2 1 1
⁄ ⁄
4, 2
#6-350 #6-350
150 OH/UG S9647-RL-150 H.O. kcmil kcmil
NONE 47⁄8 13 32 21⁄2 21⁄2 21⁄2 21⁄2 21⁄2 1 1
⁄ ⁄
4, 2
#6-350 #6-350
200 OH/UG S9647-RL-200 H.O. kcmil kcmil
NONE 47⁄8 13 32 21⁄2 21⁄2 21⁄2 21 ⁄2 21⁄2 1 1
⁄ ⁄
4, 2

HUBS: For proper hub selection refer to the hub suffix chart on the accessory page.
CONECTORS: Extruded aluminum connectors are tin plated with triplex on the load side.
BREAKERS: Supplied with factory installed double pole circuit breakers of amperage shown.
U/L LISTED: For U/L listed units see other choices on following pages.

40
100, 150 & 200 AMP—4 TERMINAL—METER MAIN
RINGLESS / RING TYPE—120/240 VAC

1 1 2

4 3 4
5

U8144-XL U3491-XL-200

∅3W
4 TERMINAL—METER-MAIN—RINGLESS / RING TYPE—OVERHEAD / UNDERGROUND—1∅
RING TYPE RINGLESS CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CU/AL BY-
AMPS CATALOG CATALOG HUB
LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5
NUMBER NUMBER
100 U8144-RL U3499-RL H.O. #6-2/0 #14-1/0 NONE 33⁄4 11 22 2 2 2 2 1 1
⁄ ⁄
4, 2

150 #6-350 #1-300


U8143-RL-150 U3491-RL-150 H.O. kcmil kcmil
NONE 41 ⁄8 12 29 21⁄2 21⁄2 21⁄2 21⁄2 1
⁄4
200 #1-300 #1-300
U8143-RL-200 U3491-RL-200 H.O. kcmil kcmil
NONE 41⁄8 12 29 21⁄2 21⁄2 21⁄2 21⁄2 1
⁄4
HUBS: For proper hub selection refer to the hub suffix chart on the accessory page.
SEALING RINGS: Ring type units priced with MR-2 sealing ring. See accessory page for other choices.
BREAKERS: Bolt-on circuit breakers are factory installed in the 8143 and 3491 series. The 8144 & 3499 do not
come with breakers unless specified on order and require plug-in style.

BREAKER COMPATIBILITY CHART


RING TYPE RINGLESS
AMPS CATALOG BREAKER CATALOG BREAKER
NUMBER NUMBER
100 U8144-(*) HQP2100 U3499-(*) HQP2100
150 U8143-(*)-150 UQFB-150-X1 U3491-(*)-150 UQFB-150-X1
200 U8143-(*)-200 UQFB-200-X1 U3491-(*)-200 UQFB-200-X1

41
200 AMP—4 TERMINAL—SERVICE ENTRANCE
MAIN COMBINATIONS—METERED—120/240 VAC

30" 32"

AABB A A BB

12" 8" 8"


1 4 3 4 3 4
5" 2 3 1 2 5" 5" 2
4 4 4 4 1 4
MUSE-200 MUSE-AP

USE-M-200-MB
MUSE-AP-200-MB
(shown without closing plates)

∅3W—10,000 AIC RATING


200 AMP—4 TERMINAL*—METERED—RING TYPE—1∅
ADDI- CONNECTORS DIMENSIONS CONCENTRIC K.O.’S
SERVICE
CATALOG BREAKER TIONAL HUB
NUMBER NUMBER CIRCUITS LINE D″″ W″″ H″″ 1 2 3 4
1 1 1 3 1 3
OH MUSE-AP-200-MB UQFP-M-200 4-branch H.O. #4-250 kcmil 5 8 32 1 ⁄4 2 ⁄2 ⁄ ⁄
2, 4 ⁄ ⁄
2, 4

1 1 1 3 1 3
OH MUSE-AP-200-ML UQFP-200 4-parallel H.O. #4-250 kcmil 5 8 32 1 ⁄4 2 ⁄2 ⁄ ⁄
2, 4 ⁄ ⁄
2, 4

1 1 1 3 1 3
OH MUSE-200 UQFB-200 — H.O. #4-250 kcmil 5 8 32 1 ⁄4 2 ⁄2 ⁄ ⁄
2, 4 ⁄ ⁄
2, 4

1 1 1 3 1 3
OH/UG USE-M-200-MB UQFP-M-200 4-branch (2) C.P. #4-250 kcmil 5 12 30 1 ⁄4 2 ⁄2 ⁄ ⁄
2, 4 ⁄ ⁄
2, 4

1 1 1 3 1 3
OH/UG USE-M-200-ML UQFP-200 4-parallel (2) C.P. #4-250 kcmil 5 12 30 1 ⁄4 2 ⁄2 ⁄ ⁄
2, 4 ⁄ ⁄
2, 4

*FIFTH TERMINAL: For field installed 5th terminal order catalog number — “105J”.
HUBS: Overhead enclosures accept up to 2 1/2″ hubs. Order hub separately.
SEALING RINGS: Units supplied with MR-2, snap style, sealing rings.
NEUTRAL BUS & GROUND BAR: Factory installed.
MUSE-AP-200-MB: 200 Amp main with provisions for 200 AMP direct wire feeder. 200 AMP breaker wired in series with
space for four single pole or one double pole and two single pole plug-in branch breakers. Order hub as extra.
MUSE-AP-200-ML: 200 Amp breaker wired in parallel with space for four single pole or one double pole and two single
pole plug-in parallel breakers. Order hub as extra.
MUSE-200: 200 AMP bolt-on main factory installed. No branch circuit breaker space available. Order hub as extra.
USE-M-200-MB: 200 Amp main with provisions for 200 AMP direct wire feeder. 200 AMP plug-in breaker wired in series
with space for four single pole or one double pole and two single pole branch breakers. Two closing plates included. Not
approved for underground service by EUSERC utilities.
USE-M-200-ML: 200 Amp breaker wired in parallel with space for four single pole or one double pole and two single pole
plug-in parallel breakers. Two closing plates included. Not approved for underground service by EUSERC utilities.
BREAKERS: Units are also available with 150 or 175 AMP breakers. Replace “-200” with “-150” or “-175” for a 150 or
175 AMP breaker. Refer to accessories for ordering information.
NOTE: Quadplex style breakers may be used in accordance with the NEC.

42
100 AMP—4 & 7 TERMINAL
METER MAINS—RING TYPE—120/240 VAC OR 120/208Y VAC

U3424-RL-100 U3427-RL U3564-O


(without breaker) (without breaker)

120 / 240 VAC


(4 terminal)

120 / 240 VAC


or 120 / 208Y
(7 terminal)
1 2
1
3424 3564
3 3427 3567
4 5  2 3
3575 4 4 3585

100 AMP—4 & 7 TERMINAL—RING TYPE


NO. CONNECTORS DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL
OF SERVICE BREAKER
TERMS NUMBER LINE LOAD D″″ W″″ H″″ 1 2 3 4 5
1
4 OH U3424-RL-100 100A-2P #6-2/0 #3-1/0 4 ⁄8 8 23 2 2 21⁄2 1⁄4 ⁄ ⁄
1 1
4, 2

7
7 OH U3427-RL-100 100A-3P #6-2/0 #3-1/0 4 ⁄8 10 26 2 2 21⁄2 1⁄4 ⁄ ⁄
1 1
4, 2

7 1
4 UG U3564-O-100 100A-2P #12-1/0 #3-1/0 4 ⁄8 14 ⁄8 20 2 1 ⁄2 1
2 ⁄2 21 ⁄2 ⁄ ⁄
1 1
4, 2 —
7 1
7 UG U3567-O-100 100A-3P #12-1/0 #3-1/0 4 ⁄8 14 ⁄8 20 2 1
2 ⁄2 21 ⁄2 ⁄ ⁄
1 1
4, 2 —
#2-350 1
4 OH U3575-RL-100 100A-2P * kcmil
#3-1/0 4 ⁄8 8 30 2 2 21 ⁄2 1⁄4 ⁄ ⁄
1 1
4, 2

#6-350 1 1
4 UG U3585-O-100 100A-2P * kcmil
#3-1/0 5 ⁄2 14 ⁄8 26 3 3 3 ⁄ ⁄
1 1
4, 2 —

*These units have provisions for a field installed, 100 Amp, 2-pole, branch plug-in circuit breaker.
BREAKERS: Units are supplied from the factory with plug-in circuit breakers.
FLUSH MOUNT KITS: For field installed flush mount kits, order catalog number K3431 for the U3424 unit and
K3432 for the U3427 unit. Kits are available for overhead units only.
SEALING RINGS: Units are supplied with MR-4, screw type, sealing rings.

43
100 & 200 AMP—4, 5 & 7 TERMINAL—METER MAINS—JAW CLAMPING LEVER
RINGLESS—120/240 VAC OR 120/208Y VAC

METER BYPASS
WITH
MAIN BREAKER

M I L B A N K

1 1 2

4 3 4
5 6

U3791-RXL-200 U3771-XL-100
U3781-RXL-200

∅3W—120/240 VAC
100 & 200 AMP–4 TERMINAL–RINGLESS–1∅
CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
AMPS SERVICE HUB
NUMBER
LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5

100 OH/UG U3741-XL-100 C.P. #6-2/0 #14-1/0 LEVER 47⁄8 13 28 2 2 21⁄2 1


⁄4 1 1
⁄ ⁄
4, 2

200 OH/UG U3791-RXL-200 C.P. #6-350 #3-300 47⁄8 13 34


kcmil kcmil
LEVER 21⁄2 21⁄2 3 1
⁄4 1 1
⁄ ⁄
4, 2

∅4W—120/240 VAC OR 120/208Y VAC


100 & 200 AMP—7 TERMINAL—RINGLESS—3∅
CONNECTOR DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
AMPS SERVICE HUB
NUMBER PASS
LINE LOAD D″″ W″″ H″″ 1 2 3 4 5

100 OH/UG U3771-XL-100 C.P. #6-2/0 #14-1/0 LEVER 4 ⁄8


7 13 28 2 2 21⁄2 1
⁄4 1 1
⁄ ⁄
4, 2

200 OH/UG U3781-RXL-200 C.P. #6-350 #3-300 4 ⁄87 13 34


kcmil kcmil
LEVER 21⁄2 21⁄2 3 1
⁄4 1 1
⁄ ⁄
4, 2

FIFTH TERMINAL: For field installed fifth terminal order catalog number K3866.
HUBS: Units supplied with standard closing plates. For proper hub selection see hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Extruded aluminum connectors are tin plated.
BREAKERS: The U3741 unit is supplied with a 2-pole, 100 Amp plug-in breaker, factory installed. The U3791 unit is sup-
plied with a 2-pole, 200 Amp bolt-on breaker, factory installed. The U3771 unit is supplied with a 3-pole, 100 Amp plug-in
breaker, factory installed. The U3781 unit is supplied with a 3-pole, 200 Amp bolt-on breaker, factory installed.

44
320 AMP—4 TERMINAL—METER-MAINS—RINGLESS / RING TYPE—120/240 VAC

320 AMP CONTINUOUS


400 AMP MAX

1 1 2

3 4 4
5
FIG. 1
5

1 1 2

5 FIG. 2
3 4 5

1
4 4 4 4 4 4 4
5 4 4 4 4 4 4
2 4 4 4 4 4

M400-UG-APS-LC 5 5 4 4 4 5 5

 4 4 4 4 4 4 4
4 4 4 4 4
FIG. 3
3 2 5 5 5 5

320 AMP—1∅ ∅—4 TERMINAL—RINGLESS


200 AMP MAIN BREAKER OR (2) 200 AMP ‘T’ FUSED PULLOUT SWITCHES INSTALLED
CONNECTORS DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
SERV. DESCRIPTION FIG.
NUMBER LINE LOAD PASS D″″ W″″ H″″ 1 2 3 4 5 #

M400-PAR➀
UQFP-200 + #6-350 1 1
OH (provision for UQFP) kcmil
C.B. LEVER 6 ⁄8 9 ⁄2 471⁄8 2 2 2 1
1
⁄2 1 3
2, 4⁄ ⁄ 2

M400-UG-PAR➀ (provision for UQFP)


UQFP-200 + #6-350 1
UG kcmil
C.B. LEVER 6 ⁄8 221⁄8 36 1
2 ⁄2 1
2 ⁄2 4 2
1
⁄2 1 3
2, 4⁄ ⁄ 1
(2) “T”-FUSE #6-350 1 1 1 1 1 1 3
UG M400-UG-PAR-P➁ PULLOUTS kcmil
PULLOUT LEVER 6 ⁄8 22 ⁄8 36 2 ⁄2 2 ⁄2 4 2 ⁄2 2, 4⁄ ⁄ 1

320 AMP—1∅ ∅—4 TERMINAL— RING TYPE


200 AMP MAIN BREAKER OR (2) 200 AMP ‘T’ FUSED PULLOUT SWITCHES INSTALLED
M400-APS ➀
UQFP-200 + #6-350 1 1
OH (provision for UQFP) kcmil
C.B. NONE 6 ⁄8 9 ⁄2 471⁄8 2 2 2 1
1
⁄2 1 3
⁄ ⁄
2, 4 2

M400-UG-APS ➀ (provision for UQFP)


UQFP-200 + #6-350 1 1 1 1 1 1 3
1
UG kcmil
C.B. NONE 6 ⁄8 22 ⁄8 36 2 ⁄2 2 ⁄2 4 2 ⁄2 ⁄ ⁄
2, 4

(2) “T”-FUSE #6-350 1


UG M400-UG-APS-P ➁ PULLOUTS kcmil
PULLOUT NONE 6 ⁄8 221⁄8 36 2
1
⁄2 2
1
⁄2 4 2
1
⁄2 1 3
⁄ ⁄
2, 4 1

UG ➀ UQFP-200 +
M400-UG-APS-LC* (provision for UQFP) #6-350 C.B. NONE 6
1
⁄8 28 40 1
1
⁄2 2
1
⁄2 4
1 3
2, 4⁄ ⁄ 1 3
kcmil

*Unit shipped with load center main breaker installed. These units also have room for 24 single pole circuit breakers (stan-
dard plug-in style) in 1″ spaces (40 circuits maximum with 1/2″ format breakers.)
RINGLESS STYLE: Ringless style meter sockets come with lever bypass. The lever supplies clamping action on meter
spades and also operates bypass device.
HUBS: Overhead units shipped with one 3″ hub. Underground units do not have hub provision.
BUSSING: Bonded neutral bus and ground bar are factory installed.
FIFTH TERMINAL: For field installed fifth terminal order catalog number K3865.
➀ 10,000 AIC rated; for 22,000AIC add suffix “-22” to the catalog number. (l.e. M400-PAR becomes M400-PAR-22.)
➁ 200,000 AIC rated.

45
320 AMP—4 TERMINAL—METER MAIN—JAW CLAMPING LEVER
∅3W
2 / 200 AMP CB—1∅

320 AMP CONTINUOUS


400 AMP MAX.

3 3 PREWIRED WITH
MILBANK WEST BREAKERS

1 2

3 3

1 1 2

3 3 4 4
5

U4031-O-2/200
U3849-O-2/200

320 AMP–4 TERMINAL—METER MAIN WITH BREAKERS—RINGLESS


CONNECTORS DIMENSIONS CONCENTRIC K.O.’S
CATALOG CU/AL BY-
SERVICE HUB
NUMBER PASS D″″ W″″ H″″ 1 2 3 4 5
LINE LOAD
3/8″ X 16 #1- 300 3⁄4
U4031-O-2/200 UG NONE STUDS kcmil LEVER 5 25 30 3 3 4 3 1
3/8″ X 16 #1- 300 LEVER 4 ⁄8
7
U3849-O-2/200 UG NONE STUDS kcmil 13 58 21⁄2 21⁄2 ⁄16
5
— —

CONNECTORS: The line wire section is supplied with 3⁄8″–16 studs with hex head nuts and captive Belleville
washers. For single lug connector kits order as extra: K1539 (350 kcmil), K1540 (600 kcmil.) For twin: K1350
(350 kcmil.)
BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device.
FIFTH TERMINAL: For field installed fifth terminal order catalog number K3865.

46
200 AMP—SERVICE ENTRANCE—MAIN COMBINATION—120/240 VAC

AABB
A
B
A
B

3 4 3 4 3 4
1 2 4 1 2 4 1 2 4

USE-200 USE-22 USE-AP

USE-22-200-MB

∅3W—10,000 AIC RATING


200 AMP—BREAKER ENCLOSURE—1∅
CONNECTORS DIMENSIONS CONCENTRIC K.O.’S
SERVICE
CATALOG BREAKERS ADDITIONAL HUB
NUMBER INSTALLED CIRCUITS LINE D″″ W″″ H″″ 1 2 3 4
1 3 1 3
OH USE-AP-200-MB UQFP-M-200 4-Branch 2″ #4-250 kcmil 5 8 26 1 2 ⁄ ⁄
2, 4 ⁄ ⁄
2, 4

1 3 1 3
OH USE-AP-200-ML UQFP-200 4-Parallel 2″ #4-250 kcmil 5 8 26 1 2 ⁄ ⁄
2, 4 ⁄ ⁄
2, 4

1 3 1 3
OH USE-200 UQFB-200 — H.O. #4-250 kcmil 4 8 23 1 2 ⁄ ⁄
2, 4 ⁄ ⁄
2, 4

1 3 1 3
OH USE-22-200-MB UQFB-M-200 4-Branch 2″ #4-250 kcmil 4 8 23 1 2 ⁄ ⁄
2, 4 ⁄ ⁄
2, 4

NOTE: The neutral bus/ground bar is factory installed.


USE-AP-200-MB: 200 AMP main with provisions for 200 AMP direct wire feeder. 200 AMP breaker wired in series with plug-in
style bus. Space for four single pole, or one double pole and two single pole plug-in branch breakers. One 2″″ hub included.
USE-AP-200-ML: 200 AMP breaker wired in parallel with plug-in style bus. Space for four single pole, or one double pole and
two single pole plug-in parallel breakers. One 2″″ hub included.
USE-200: 200 AMP bolt-on main factory installed. No branch circuit breaker space available. Hub not included.
USE-22-200-MB: 200 AMP main with provisions for 200 AMP direct wire feeder. 200 AMP bolt-on breaker wired in series with
plug-in style bus. Space for four single pole or two 2-pole plug-in, branch circuit breakers. One 2″″ hub included.
BREAKERS: Units are also available with 150 or 175 AMP breakers. Replace “-200” with “-150” or “-175” for a 150 or 175
AMP breaker. Refer to the accessory section for ordering information.
NOTE: Quadplex style breakers may be used in accordance with the NEC.

47
20, 30 & 50 AMP—RECEPTACLE BOX—TYPE 3R

Padlock Provision

U3769-O-20
2 1 3

20, 30 & 50 AMP— RECEPTACLE BOX—TYPE 3R

CATALOG GROUND LUG DIMENSIONS CONCENTRIC K.O.’S


SERVICE HUB CU/AL
NUMBER D″″ W″″ H″″ 1 2 3
U3769-RL-20 OH H.O. #14-4 AWG 45⁄8 55⁄8 53⁄4 11⁄4 ⁄ ⁄
1 1
4, 2 ⁄ ⁄
1 1
4, 2

U3769-RL-30 OH H.O. #14-4 AWG 45⁄8 55⁄8 53⁄4 11⁄4 ⁄ ⁄


1 1
4, 2 ⁄ ⁄
1 1
4, 2

U3769-RL-50 OH H.O. #14-4 AWG 45⁄8 55⁄8 53⁄4 11⁄4 ⁄ ⁄


1 1
4, 2 ⁄ ⁄
1 1
4, 2

APPLICATION: These 20, 30 & 50 Amp receptacles are a portable and convenient means of providing power for
cord connected equipment. They can provide one or more receptacles in a single enclosure.
FINISH: As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an
attractive, light gray, baked powder coating. Our “state of the art” finish combines epoxy and polyester hybrid resins
into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish.
WELDED FLANGE: To insure long lasting service for outdoor installations the receptacle box has spot-welded
flanges that meet Nema Type 3R construction requirements.
INSTALLATION: The lift-up doors are removable to assure easy access and stay open for user convenience. There
are a wide range of receptacle configurations. All units are equipped with #14-4 Cu/Al ground lug connectors.
SAFETY: The dead front prevents contact with live parts, and padlock provisions prevent unauthorized use.

48
100 AMP—POWER OUTLETS—METERED & UNMETERED—120/240 VAC

HARDWIRED

26"

7 1/4"
MUPO
7 1/4"
M-UPO 5 3/4
3 5/16"

Shown with
UPO-75C loop feed
connectors
(-C)

14 3/4

7 1/4" 7 1/4"

5 3/4
3 5/16"
UPO-35122
STANDARD CONFIGURATIONS

MUPO


BLANK 10G 11G 13
1-20A/125V 2-20A/125V 1-30A/125V

WIRE
CAT. # RANGE DESCRIPTION WT.
Unmetered, 100A Enclosed
UPO #12-1 11
Plug-In Style Bus
36G 38G 41G 54 55G
100A Continuous Duty
MUPO #10-1 19 1-20A/125V 2-20A/125V 1-20A/125V 1-50A / 1-20A / 125V
Meter Socket / UPO Combination 1-20A/250V 1-20A/250V 1-30A/125V 125-250V 1-50A/125-250V
20A with (1) 5-20R Receptacle
P-10 #14-10 —
Receptacle Box Only
30A with (1) TT-30 Receptacle
P-13 #14-10 —
Receptacle Box Only
50A with (1) 14-50R Receptacle
P-54 #12-4 — 58 61 611G 75G 76G
Receptacle Box Only
1-30A/125V 2-30A/125V 1-20A/125V 1-20A/125V 2-20A/125V
1-50A/125-250V 2-30A/125V 1-30A/125V 1-50A/125-250V
1-50A/125-250V
CIRCUIT BREAKERS: Uses plug-in circuit breakers—4 poles available in the “blank” model (except P-10, P-13, P-54.)
Quadplex style breakers may be used in accordance with the NEC.
HUBS: Accepts up to 2 1/2″ hub (order separately). Closure plate included (except P-10, P-13, P-54.)
CONNECTORS: Extruded aluminum connectors are tin plated. UPO and MUPO units are supplied with an insulated,
bondable neutral.
GFI BREAKER: For 20 Amp GFI breaker replace the “-GR” suffix with “-GB.”
LOOP FEED: For loop feed capability add suffix “C”. (i.e. UPO-36GR becomes UPO-36CGR.) Not available for MUPO
models.
NOTE: Receptacle selections should comply with NEC 551-71 when used for Recreational Vehicle Parks.

49
100 AMP—POWER OUTLET PEDESTALS—120/240 VAC

HARDWIRED

A N G B

A N G B

STANDARD CONFIGURATIONS

AABB

BLANK 10CGR 11CGR 13C


1-20A/125V 2-20A/125V 1-30A/125V

HP-UPO4-75CGB

36CGR 38CGR 41CGR 54C 55CGR


OPTIONS AVAILABLE SUFFIX 1-20A/125V 2-20A/125V 1-20A/125V 1-50A / 1-20A / 125V
1-20A/250V 1-20A/250V 1-30A/125V 125-250V 1-50A/125-250V
Pad Mounting -PD

20A GFI Receptacle -GR

20A GFI Breaker -GB


Twin Line 58C 61C
-C 61C1GR 75CGR 76CGR
Termination Lugs
1-30A/125V 2-30A/125V 1-20A/125V 1-20A/125V 2-20A/125V
Lock for Cover -L 1-50A/125-250V 2-30A/125V 1-30A/125V 1-50A/125-250V
1-50A/125-250V

CAT.# DESCRIPTION WT.


HP-UPO4 UPO built into direct burial pedestal 36 
HPDUPO4 Double, back-to-back UPO pedestal 47

RATING: 120/240 volt, 1∅, 100 Amp power outlet pedestal.


CONNECTORS: Twin line termination lugs #1/0-250 kcmil CU/AL per phase for looping.
CIRCUIT BREAKERS: Uses plug-in CB’s—4 poles available in “blank” model. Quadplex style breakers may be used in
accordance with the NEC.
SINGLE OR DOUBLE: Available as a single unit (HP) or as a double (HPD), back-to-back unit.
BREAKER: For 20 Amp GFI breaker replace the suffix “-GR” with “-GB.”
NOTE: Receptacle selections should comply with NEC 551-71 when used for Recreational Vehicle Parks.

50
100 AMP—RECREATIONAL VEHICLE PEDESTALS—RING TYPE—120/240 VAC

HARDWIRED

A G N B A G N B

STANDARD CONFIGURATIONS
ADDITIONAL CONFIGURATIONS AVAILABLE
(CONSULT FACTORY)

AABB

BLANK 20GR 220GR 30 230 -100

3020GR 50 5020GR 5030 503020GR -100-F1 MPRV

OPTIONS AVAILABLE SUFFIX


Bolt/Stud Line Termination -SU
78″ Tall Post -78
Pad Mounting -PD 

With Raceway -RW CAT.# DESCRIPTION WT.


Ringless Meter Socket -R
15A or 20A Street Light C/B -15L MPRV Single RV Metered Pedestal 49
Ahead of Meter -20L
20A GFI Receptacle -GR MPRVD Double RVMetered Pedestal 67
20 Amp GFI Breaker -GB
100 Amp UCP-2100-W
Main Breaker wired in series -MB MPRV-
Breaker Installed 50
100A Breaker Kit (main) ** -F1 100
(*see note below)
100A Breaker Kit (parallel) ** -F2
CONNECTORS: Twin line termination lugs #6-350 kcmil CU/AL per phase for looping.
BLANK OR CIRCUIT BREAKER / RECEPTACLE: Specify unit blank or with circuit breaker / receptacle combinations noted in
the chart above. Receptacle selections should comply with NEC 551-71 when used for Recreational Vehicle Parks. Blank units
are furnished with space for four single pole, or one double pole and two single pole plug-in circuit breakers. Quadplex style
breakers may be used in accordance with the NEC.
*BREAKER: Specify MPRV-100 for 100 Amp service pedestal with direct feed kit and 100 AMP C/B wired in parallel. Space for
two additional single pole C/B’s provided. Series wiring available; specify MPRV-100-MB.
**ADDITIONAL CIRCUITS / BREAKER: A field installed breaker kit is available. Order as extra WK-2100. Kit includes a 100
AMP, 2-pole, bolt-on breaker with mounting clip, wire and hardware. Breaker may be wired in series or parallel. Space for addi-
tional four single pole, or one double pole and two single pole breakers. For factory installed kit, add suffix “-F1” (main) or “-F2”
(parallel) to catalog number (i.e. MPRV-100-F1.)
DIRECT FEED KIT: Order as extra, catalog number PF-KR when using a main breaker. Kit allows for direct conduit hook-up
from pedestal rear for single pedestals. See price list for adder.

51
200 AMP—ALL PURPOSE METERED PEDESTALS—RING TYPE—120/240 VAC

HARDWIRED

A G N B

A G N B

STANDARD CONFIGURATIONS
ADDITIONAL CONFIGURATIONS AVAILABLE
(CONSULT FACTORY)

AABB

BLANK 20GR 220GR 30 230

MPAP 3020GR 50 5020GR 5030 503020GR

OPTIONS AVAILABLE SUFFIX



Bolt/Stud Line Termination -SU
CAT.# DESCRIPTION WT. 78″ Tall Post -78
Pad Mounting -PD
Single, all purpose metered
MPAP pedestal 50 With Raceway -RW
Ringless Meter Socket -R
Double, all purpose metered
MPAPD pedestal 68 15A or 20A Street Light C/B -15L
Ahead of Meter -20L
Single, all purpose un-metered 20A GFI Receptacle
TPAP 40 -GR
pedestal, 63″ high
20A GFI Breaker -GB
200A, UQFP-200 Breaker For 8″ x 8″ post with four
MPAP-200 52 -DU
Installed (*see note below) Utility Studs per phase
Main Breaker Wired in Series -MB

CONNECTORS: Twin line termination lugs #6-350 kcmil CU/AL per phase for looping.
BLANK OR CIRCUIT BREAKER / RECEPTACLE: Specify unit “blank” or with circuit breaker / receptacle combinations
noted in chart above. Receptacle selections should comply with NEC 551-71 when used for Recreational Vehicle Parks.
Blank units are furnished with space for four single pole, or one double and two single pole plug-in breakers in addition to
main. Quadplex style breakers may be used in accordance with the NEC.
*BREAKER: 100, 125, 150,175 or 200 AMP circuit breakers may be factory wired in parallel. Add breaker amperage as
suffix to catalog number (i.e. MPAP-200 is supplied with 200A C/B.) Space for four additional single pole, or one double and
two single pole plug-in, parallel breakers provided. Series wiring available; specify MPAP-(amp)-MB.
DIRECT FEED KIT: All MPAP and MPAPD pedestals are supplied from the factory with a direct feed kit for rear conduit
hook-up. See next page for illustration.

52
MOBILE HOME PEDESTAL ACCESSORIES
FOR HARDWIRED UNITS ON PAGES 50, 51, 52

4"

EXISTING PVC COVERED L.H. LINE BUS

EXISTING PVC COVERED R.H. LINE BUS


EXISTING BUS ANGLE
42"

EXISTING BUS ANGLE

24"
REBUILD KITS
Catalog no. RMK-100
For old style (pre 1969) Unicorn 100 Amp
MPP style pedestals.
DIRECT FEED KIT Specify: RMK-100 for meter socket only.
Catalog No. PF-KR RBK-1 for complete interior. KNOCKOUTS
(2",1 1/2", 1 1/4")
Rear K/O kit for direct conduit hook-
up to mobilehome. Instructions UNDERGROUND TERMINAL
included. 11⁄2″, 13⁄4″, 1-11⁄2″ to 2″ con- POST
centric K/O provided. Catalog No. TT350
(for MPAP, MPRV) For termination of underground
cables from remote meter
pedestals.

METER SOCKET BLANK


COVER
48"
Catalog No. GC-2 PVC plastic
cover for use with ring type
meter socket.
8"
(10 per carton) 29"
RACEWAY

RACEWAY
POST

4" EK-6
3 1/2"

POST / RACEWAY
POST EXTENSION
Post Catalog No. PD
Catalog No. EK-6
Raceway Catalog No. RW
Increases post meter height by 6″ (for
For use as a wireway with pad mounted
MPAP, TPAP, MPRV style posts.)
post units.Factory installed only
METER HOOD
(for MPAP, MPRV)
Catalog No. MHD
8″W x 8″ H x 6″ D
(for MPAP, MPRV)

HUBS 5TH TERMINAL PS-104

Catalog No. U-HUB-(*) Catalog No. 105J


Conduit hubs available. The 5th Terminal may be placed
TV OR TELEPHONE (*conduit size desired) in the 6 or 9 o’clock position. POST STABILIZING FEET
BRACKET Catalog No. PS-104
Catalog No. TV-835 To stabilize post in unstable
(for MPAP, MPRV) soil conditions.

53
100-200 AMP—4 TERMINAL—METERED & UNMETERED POWER OUTLET—120/240 VAC

PROVISION FOR MODULAR FITTINGS

HARDWIRE KIT
Catalog Number K3785
(Includes Clip and mounting hardware
to hardwire on C/B.)
3"

2 1/2"

(Both units shown without


1
filler plates,order breaker as
extra.)
2 2 2
3 4
A B A B A B

Available U3350-RL-200
U3784-RL Circuits 

∅3W
200 AMP—UNMETERED POWER OUTLETS—1∅
LINE BY- DIMENSIONS CONCENTRIC K.O.’S
SER- CATALOG
VICE NUMBER DESCRIPTION HUB CONNECTORS PASS
CU / AL D″″ W″″ H″″ 1 2 3 4

OH U3348-RL Unmetered H.O. #6 AWG-300


kcmil NO 6 10 18 — 2 1 ⁄2 1
⁄4

∅3W
100-200 AMP—METERED POWER OUTLET WITH BRANCH CIRCUIT PROVISION—1∅
LINE BY- DIMENSIONS CONCENTRIC K.O.’S
SER- CATALOG CATALOG
HUB CONNECTORS
VICE NUMBER NUMBER PASS
CU / AL D″″ W″″ H″″ 1 2 3 4

OH U3350-RL Metered ring type H.O. #6 AWG-350 NO 51⁄2 10 31 2 2 ⁄4


1 ⁄2
1
kcmil
OH U3784-RL Metered ringless H.O. #6 AWG-350 NO 51⁄2 10 31 2 2 ⁄4
1 ⁄2
1
kcmil
HUB: For proper hub selection refer to the hub suffix chart on the accessory page.
U3348: The 3348 can be field wired to connectors on bus panel for parallel circuits or can be wired direct to breaker in center
position for a true main. Unit is factory ready for one 2-pole or two 1-pole circuit breakers. An additional four (1-pole) positions
may be used by ordering two circuit breaker mounting clips, K3785. Each clip will hold two 1-pole or one 2-pole circuit breakers.
U3350: The 3350 is wired from meter socket load side to breaker panel bus when breakers are not factory installed. This unit is
factory ready for three 2-pole or six 1-pole, plug-in type, parallel breakers.
U3784: The 3784 is wired from meter socket load side to breaker panel bus when breakers are not factory installed. This unit is
factory ready for three 2-pole or six 1-pole, plug-in type, parallel breakers.
BREAKER: If factory installed breakers are required, insert amperage at the end of the catalog number (i.e. U3348-RL-200.)
Factory installed breakers on the 3350 & 3784 units will be wired parallel from 0-140 AMPS and wired as a main from 150-200
AMPS. If different option is desired, add suffix “-MB” (wired as main), or “-ML” (wired as parallel) to catalog number. Quadplex
style breakers may be used in accordance with the NEC.
MODULAR FITTINGS: Units are supplied with blank filler plates which can be removed if P/O fittings are installed. To determine
possible combinations of P/O fittings, follow these guide lines: 1) Twin P/O fittings must be installed on the left side; 2) Single P/O
fittings may be installed on either side; 3) A maximum of two fittings may be installed. See page 56 for a list of fittings. Note
that the circuit breaker clips will need to be removed on the 3350 & 3784 units if fittings are installed on the left or right side.
Simply remove the screws on the clip. Each fitting uses two circuits.

54
125 & 200 AMP—4 TERMINAL—RV/MH
METERED & UNMETERED PEDESTALS—120/240 VAC

PROVISION FOR MODULAR FITTINGS

50"

18"
74"
23"

GRADE
LINE

24"
6" 10"
DIRECT
22"
BURIAL KIT

GRADE LINE
STABILIZER
FOOT
12"

24"
Metered
Pad Mount Style

A B A B A B Unmetered
Direct Burial Style

U3139-O-20/30/50 Available U3142-O-20/30/50


(shown without stabilizer foot) Circuits  (shown without stabilizer foot)

125 & 200 AMP—METERED & UNMETERED—RINGLESS & RING TYPE


RINGLESS RING TYPE TWIN
UNMETERED
AMP TYPE METERED METERED LINE CONNECTORS
CATALOG #
CATALOG # CATALOG # CU/AL
125 SINGLE — U3249-O * U3142-O #6 AWG-350 MCM

125 TWIN — U3250-O * U3143-O #6 AWG-350 MCM

200 SINGLE U3139-O * U3240-O — #6 AWG-350 MCM


200 TWIN U3140-O * U3241-O — #6 AWG-350 MCM
MODULAR FITTINGS: Units are supplied with blank filler plates which can be removed if P/O fittings are installed. To determine
possible combinations of P/O fittings, follow these guidelines: 1) Twin P/O fittings must be installed on left side. 2) Single P/O fittings
can be installed on either side. 3) A maximum of two fittings can be installed. Each fitting uses two circuits. See page 56 for a list of
fittings.
REQUIRED ACCESSORIES: When ordering the metered pedestal, specify on the order which kit is preferred: K3236/K3188 for
direct burial application or K3237 for pad mounting the pedestal. Standard pricing includes these items. For field installed Penta Bolt
Locking pedestal fronts, order as extra catalog number K3778. See price list for adder. Unit must have direct burial kit installed to
use Penta-Bolt front.
SEALING RINGS: All metered ring type units are supplied with MR-4 screw type, sealing rings.
SERVICE: Pedestals are factory assembled for back to back service.
UNMETERED: The unmetered pedestal is complete as ordered for direct burial application.
*BREAKER: If factory installed breaker is required, insert breaker amperage at end of catalog number (i.e. U3240-O-200 for 200A
C/B.) Bussed units are marked with an asterisk (*) and all breakers will be parallel. All other units are wired in parallel to panel lugs
from 0-140 Amps and wired in series from 150-200 Amps. If a different option is desired for “wired” units, add suffix “-MB” (wired as
main) or “-ML” (wired parallel) to catalog number. In addition to main, four circuits are available: four single-pole or two double-pole.
A breaker mounting clip is required for every two positions; order as extra catalog number K3785. Quadplex style breakers may be
used in accordance with the NEC.

55
POWER OUTLET FITTINGS*—SINGLE & TWIN—FOR MODULAR UNITS ONLY

POWER OUTLET FITTINGS ➀ ➁ ➂


U3144-20GR U3144-20 U3144-20GR/30


(Single) (Single) (Twin)
(1) 20 Amp., (1) 20 Amp., (1) 20 Amp.,
single pole C/B single pole C/B single pole C/B
(1) 20 Amp.,125V,GFI (1) 20 Amp.,125V, (1) 30 Amp., single
Duplex Receptacle Duplex Receptacle pole C/B
(1) 20 Amp.,125V,GFI
*This unit has a non-GFI Duplex Receptacle
breaker and is suitable (1) 30 Amp., 125V
for temporary service Travel Trailer
only. Receptable

U3144-30 U3144-30GB U3144-30/50


(Single) (Single) (Twin)
(1) 30 Amp., (1)30 Amp., GFI (1) 30 Amp.,
single pole C/B single pole C/B single pole C/B
(1) 30 Amp.,125V, (1)30 Amp.,125V (1) 50 Amp, double
Travel Trailer Travel Trailer pole C/B
Receptacle Receptacle (1) 30 Amp.,125V,
Travel Trailer
Receptacle
(1) 50 Amp., 125/240V
Receptacle

U3144-50 U3144-20GR/20GR U3144-50/50


(Single) (Twin) (Twin)
(1) 50 Amp., (2) 20 Amp., (1) Twin, 50/50 Amp.
double pole C/B single pole C/B double pole C/B
(1) 50 Amp.125V/240V (2 ) 20 Amp.,125V,GFI (2) 50 Amp.,125V/240V,
Receptacle Duplex Receptacles Receptacles

*NOTE: These units are to be used in conjunction with a pedestal or powerhead. No enclosure provided.
➀ Panels are available with twistlock receptacles. Contact factory for pricing.
➁ Suitable for use with the following units: U3139, U3140, U3240, U3241, U3249, U3250, U3142, U3143, U3348, U3784, U3350.
➂ For 20 or 30 Amp GFI breaker (instead of GFI receptacle) change the suffix to “-20GB” or “-30GB” (i.e. U3144-20GR/20GR
becomes U3144-20GB/20GB).

56
200 AMP—MOBILE HOME METER PEDESTALS—4 TERMINAL—RINGLESS—120/240 VAC

/8"
41

50"

/2"
51
74"
23"
10"

GRADE
LINE

24"
DIRECT
BURIAL KIT

STABILIZER
FOOT 12"

U3138-O U3137-O

200 AMP—4 TERMINAL—RINGLESS

TWIN CIRCUIT
CATALOG METER MOUNTING
LINE CONNECTORS DESCRIPTION
NUMBER POSITIONS TYPE PROV.
CU/AL
U3136-O SINGLE POST #6 AWG-350 kcmil 6 Provisions for Main with
U3137-O DOUBLE POST #6 AWG-350 kcmil 6 Branch or Parallel Breakers

U3138-O SINGLE POST #6 AWG-350 kcmil 2 Provision for Main Breaker Only

U3221-O DOUBLE POST #6 AWG-350 kcmil 2 Provision for Main Breaker Only

APPLICATION: Pedestals are suitable for use as recreational vehicle and mobile home service equipment. Order as extra,
K3236 / K3188 for direct burial application, or K3237 for pad mount application. These kits are included in the price of the
pedestal.
BREAKER: If main breaker is required, insert amperage at end of catalog number (i.e. U3136-O-200 for 200A C/B.) The
3136 and 3137 units are wired as parallel from 0-140A and wired in series from 150-200A. If different option is desired, add
suffix “-MB” (wired as main), or “-ML” (wired as parallel) to catalog number. These units also have provision for four circuits
in addition to the main: four single-pole or two double-pole. Quadplex style breakers may be used in accordance to the NEC.
The 3138 and 3221 units are bussed and have provision for a main breaker only.

57
MOBILE HOME PEDESTAL ACCESSORIES FOR UNITS ON PAGES 55 & 57

35" 29" 14"


35"
42" 35" 18"
42"

14" 4 1/8" 10"


6 1/2"

LOAD WIREWAY SIDE LOAD WIREWAY SIDE LOAD WIREWAY BACK BACK LOT
MOUNTED MOUNTED MOUNTED CONNECTION BOX
Catalog Number K3308 Catalog Number K3439 Catalog Number K3309 Catalog Number S3310-0
Suitable for use with twin, Suitable for use with single, Suitable for use with single, Furnished with set-screw
metered pedestals. metered pedestals. metered pedestals. Direct type conectors.
burial only.
TELEPHONE / TV
BRACKET PENTA HEAD KIT
Catalog Number K3450 GROUND LUG KIT
WITH COVERS Catalog Number K3515
Includes two brackets and Catalog Number K3778
mounting hardware. 1/0 connector assembly for
Top and bottom front covers use with metered pedestals.
with Penta Head locking kit.

FIFTH TERMINAL
Catalog Number 5T8K2

GRADE LINE

DIRECT BURIAL KIT PAD MOUNT SLEEVE STABILIZER FOOT STAKES


Catalog Number K3236 Catalog Number K3237 Catalog Number K3188 Catalog Number K3235
Suitable for use with metered Suitable for use with metered Suitable for use with metered Designed to provide addition-
pedestals when direct burial pedestals when mounting on pedestals to provide in- al pedestal stability.
is desired. anchor bolts. ground penetration of 24″-
36″ below grade.

* Suitable for use with U3136, U3137, U3138, U3221, U3139, U3140, U3142,
U3143, U3240, U3241, U3249, U3250 Pedestals only.

58
POLYPHASE ENCLOSURES FOR “A” BASE METERS

Catalog Number Catalog Number


830 850

POLE MOUNTING BRACKETS


Order #830 for one pair (2 pcs.) with keyhole
bracket and mounting hardware.
Order #850 for two pair (4 pcs.) with
mounting hardware.

S9995-B-RL S9997-B-RL

POLYPHASE ENCLOSURE FOR “A” BASE METERS


NEW OLD NUMBER DIMENSIONS
CATALOG CATALOG OF HUB
NUMBER NUMBER POSITIONS D″″ W″″ H″″
S9995-(*)-RL S111526-(*) 1 H.O. 11 15 26

S9997-(*)-RL S112730-(*) 2 H.O. 11 27 30 11⁄16

S9999-(*)-RL S113830-(*) 3 H.O. 11 38 30 11⁄16

*BACKBOARD: Insert “B” for factory installed half board and bridge. Insert “FB” for full board only or omit if only shell is
desired.
WINDOWS AND COVERS: Units supplied with one 41⁄2″ x 6″ glass window per meter position. If glass demand rest window
is desired, add suffix “-CW” to the catalog number. If metal demand reset cover is desired, add suffix “-C” to the catalog num-
ber. If window shield is desired, add suffix “-WS” to the catalog number.
HUBS: For hubs refer to the accessory section.

FIELD INSTALLED ACCESSORIES

MILB MILB
ANK ANK MILBANK

GLASS WINDOW ALL METAL WINDOW SHIELD


DEMAND RESET COVER DEMAND RESET COVER Catalog No. WS
(41⁄2″ x 6″) (41⁄2″ x 6″)
Catalog No. SDRCW Catalog No. SDRC

59
CABLE TELEVISION PEDESTALS

CATV
CABLE
ENCLOSURES

S2096-LP S2100 S2098-O

FEATURES
Milbank’s CATV Pedestals are designed to house pedestal or aerial type taps, multi-taps, splitters, line extenders, trunk
and bridging amplifiers. The pedestals (fabricated from heavy gauge zinc coated steel and finished with an electrostati-
cally applied, baked-on epoxy-polyester resin powder coating) afford a durable, exterior and provide a low profile consist-
ing of a backplate / lower front cover assembly and an upper cover/cap assembly. There are knockout provisions for
cylinder locks and/or padlock hasps on each unit. Provisions on the back plate offer easy installation of accessory
mounting brackets. Some models present screened louvers in the upper cover/cap assembly for ventilation. All units can
be used with 24″ to 42″ stakes.
Contact general office for pricing on these items.

CABLE TELEVISION PEDESTALS

CATALOG DIMENSIONS STANDARD WEIGHT


NUMBER D″″ W″″ H″″ PACKAGE EACH
S2096-LP 6 ⁄
12 6 ⁄
12 20 4 8 LBS.

S2096-O 6 ⁄
12 6 ⁄
12 23 ⁄
14 4 14 LBS.

S2097-O 8 ⁄
14 8 ⁄
14 25 ⁄
14 2 18 LBS.

S2098-O 10 12 ⁄ 10 12 ⁄ 44 1 36 LBS.

S2099-O 10 12 ⁄ 16 46 1 50 LBS.

ACCESSORY ORDERING INFORMATION

CATALOG STANDARD WEIGHT


DESCRIPTION
NUMBER PACKAGE EACH
S2100 24″ STAKE 8 2.5 LBS.

S2100-32 32″ STAKE 8 3 LBS.

S2101 42″ STAKE 4 4 LBS.

60
SECONDARY SERVICE PEDESTAL FOR UNDERGROUND USE

1"
S9617-O GRADE LINE GRADE LINE S9618-O

12"

ORDERING INFORMATION

CATALOG PEDESTAL DIMENSIONS


NUMBER SUPPLIED WITH D″″ W″″ H″″

S9617-O (3)-6 HOLE 350 MCM 10 11⁄32 10 3⁄8 45 11⁄16


CONNECTOR BARS

S9618-O NYLON ROPE TO 10 11⁄32 10 3⁄8 45 11⁄16


SECURE SPLICES

FEATURES: Units are supplied with 3/8″-16 penta head bolt latch.
STAKE: Catalog number ( S9110 ) must be added to catalog number in order to insure shipment of 72″ stake
for free standing installation (i.e. S9617-O-S9110, or S9618-O-S9110.)

61
METER SOCKET ACCESSORIES

FIFTH TERMINALS

100-200 AMP *HEAVY DUTY JAW CLAMPING


FIFTH TERMINAL FOR FIFTH TERMINAL
“PLUG-IN" FIFTH TERMINAL
UNICORN STYLE PEDESTALS K3865
5T8K2
#105J (K3866 without neutral wire)
*For units manufactured after
August, 1992

SEALING RINGS

M-5 FIFTH TERMINAL FOR


(24 pieces per bag) RESIDENTIAL APARTMENT SERIES
(Minimum order—5 gross or 720 SNAP ACTION SCREW TYPE (125-200 AMP)
pieces supplied in detachable pairs) MR-2 MR-4 K2381

STAINLESS STEEL
#Z703865-SS

PLUG-IN BREAKER COMPATIBILITY CHART


AMPS MILBANK CUTTLER-HAMMER
(WESTINGHOUSE)
ITE MURRAY /
CROUSE-HINDS
G.E. SQ-D

125-200 — HQP / BR / WBJ — MD Q LINE —


≤ 125 TYPE UCP QUICKLAG P / QP MP Q LINE HOMELINE
BR / HQP

BREAKER CHART

CATALOG NUMBER
AMPERAGE
NUMBER OF POLES
BYPASS LINK HQP1020 20 SINGLE
TRIPLEX GROUND
HQP1030 30 SINGLE
HQP2030 30 DOUBLE
HQP2040 40 DOUBLE
HQP2050 50 DOUBLE
HQP2060 60 DOUBLE
HQP2100 100 DOUBLE
HQP2125 125 DOUBLE
WBJ2150 150 DOUBLE K1190
8180
(Order K1179 for sockets with WBJ2200 200 DOUBLE (For factory installed triplex
safety shields.) ground add suffix “-TG” to the
Bypass links are sold in pairs. catalog number.)

62
METER SOCKET ACCESSORIES

INTERCHANGEABLE UNIT HUBS

REMOVABLE HUB SMALL “RL" LARGE “R”


CLOSING PLATE OPENING (STANDARD) OPENING (HEAVY DUTY) HUB ADAPTER PLATE
SIZE SUFFIX CAT. # MILBANK MILBANK (Converts -R opening to -RL)
SUFFIX SIZE SUFFIX SIZE
NO. NO. S8324
STANDARD
-XL A7551 -WL 1″ A7514 -F 3″ A8110
(for -RL opening)
-YL 11⁄4″ A7515 -G 31⁄2″ A8111
11⁄2″
LARGE
-X S9064 -ZL A7516 -H 4″ A8112
(for -R opening)
-DL 2″ A7517
-EL 21⁄2″ A7518
HUB SUFFIX CHART
O Plain Top WL 1″ For -RL Opening
CLOSING COVERS RL YL 11⁄4″ For -RL Opening
Small Hub Opening
R Large Hub Opening ZL 11⁄2″ For -RL Opening
XL Small Closing Plate DL 2″ For -RL Opening
X Large Closing Plate EL 21⁄2″ For -RL Opening
Large Hub Opening F 3″ For -R Opening
RXL
adapted to small Closing Plate
G 31⁄2″ For -R Opening
RRL Large Hub Opening
adapted to small Hub Opening H 4″ For -R Opening

METER CLOSING PLATE METAL CLOSING PLATE HUBS FOR SWITCHES


(Gray Plastic) (For ringless sockets)
6003 CP-21 CATALOG CATALOG
SIZE SIZE
NUMBER NUMBER
METER CLOSING PLATE
(Clear Plastic) SH75 3 ⁄4″ LH125 1 1⁄4″
6116
SH100 1″ LH150 1 1⁄2″
SH125 1 1⁄4″ LH200 2″

SH150 1 1⁄2″ LH250 2 1⁄2″

BREAKER MOUNTING CLIP


(for RV/MH pedestals)
K3785

CONNECTOR KITS
SINGLE TWIN
For use with 3/8”-16 stud
SINGLE CONNECTOR KITS type units only TWIN CONNECTOR KITS
SUFFIX CATALOG # (3 per set) – 1 ∅ SUFFIX CATALOG # (3 per set) – 1 ∅
-K1 K1539 350 kcmil (MAX) -K2 K1350 350 kcmil (MAX)
-K3 K1540 600 kcmil (MAX) -K4 K1541 600 kcmil (MAX)
SUFFIX CATALOG # (4 per set) – 3 ∅ SUFFIX CATALOG # (4 per set) – 3 ∅
-K5 K3082 350 kcmil (MAX) -K6 K3442 350 kcmil (MAX)
-K7 K3441 600 kcmil (MAX) -K8 K3083 600 kcmil (MAX)

63
MILBANK WEST BREAKERS

UQFP UQFP-M
FIXED RATING
UQFP-200

200 AMP FRAME—10,000 AIC

2-POLE AMP
10,000 AIC PLUG-IN 10,000 AIC BOLT-ON*
RATING

100 UQFP-100 UQFB-100

125 UQFP-125 UQFB-125

150 UQFP-150 UQFB-150

175 UQFP-175 UQFB-175

200 UQFP-200 UQFB-200

BREAKERS: Both plug-in and bolt-on breakers are available with a split load feature. Add suffix
“-M” to specify this feed through main breaker. (UQFB-200 becomes UQFB-M-200.)
BREAKER SPECIFICATIONS: 120/240 volt A/C, single phase, two-pole, common trip 11/2″ per
pole, 200 AMP frame.
U/L LISTING: Listed by Underwriters Laboratories.
TESTING: Manufactured, certified and tested in Milbank & UL certified 65 megawatt test labo-
ratory in California.
SHIPPING QUANTITIES: Shipped one per box; 5 boxes per 16 lb. carton.

100 AMP FRAME —10,000 AIC


AMP RATING PLUG-IN BOLT-ON LUG / LUG

100 UCP-2100 UCB-2100

BREAKERS: 120/240 volt AC, single phase, two-pole, com-


mon trip 1″per pole, 100 Amp frame. Interchangeable, univer-
sal plug-in style circuit breaker.

U/L LISTING: Listed by UL and available as plug-in or as bolt-


on (lug-lug) style.
UCP

64
R E P L A C E M E N T PA R T S

PART NUMBER S PA R E PA R T S

Z904486-AO 2/0 SLOTTED NUT ASSEMBLY—125 AMP


Z904485-AO 2/0 HEX HEAD NUT ASSEMBLY—125 AMP
Z903274-AO 2/0 SLOTTED NUT ASSEMBLY WITH KK—125 AMP
Z903273-AO 2/0 HEX HEAD NUT ASSEMBLY WITH KK—125 AMP
Z905553-AO 350 KCMILHEX HEAD NUT ASSEMBLY—200 AMP
Z905524-AO 350 KCMIL HEX HEAD NUT ASSEMBLY WITH KK—200 AMP
Z911639-SC 350 KCMIL SLIDE-IN HEX HEAD NUT ASSEMBLY—200 AMP
Z910889-SC 350 KCMIL SLIDE-IN INTERNAL HEX HEAD NUT ASSEMBLY—200 AMP
K4213 2/0 DUPLEX NEUTRAL—125 AMP—WITH HEX HEAD NUT
K4212 350 KCMIL DUPLEX NEUTRAL—200 AMP—WITH HEX HEAD NUT
Z911194-AC 350 KCMIL DUPLEX NEUTRAL—FOR LEVER BYPASS UNITS WITH INTERNAL HEX NUT—200 AMP
K1190 GROUND ASSEMBLY —TO BE MOUNTED ON DUPLEX NEUTRAL
Z903303-AC 2/0—SLOTTED HALF BLOCK ASSEMBLY—7487—125 AMP
Z903603-AC 2/0—SLOTTED HALF BLOCK ASSEMBLY WITH KK—7487—125 AMP
Z911163-AC 2/0—HEX HEAD HALF BLOCK ASSEMBLY—8435—125 AMP
Z906203-AC 2/0—HEX HEAD HALF BLOCK ASSEMBLY WITH KK—8435—125 AMP
Z903323-AC 350 KCMIL—HEX HEAD HALF BLOCK ASSEMBLY—7021—200 AMP
Z904529-AC 350 KCMIL—HEX HEAD HALF BLOCK ASSEMBLY WITH KK—7021—200 AMP
350 KCMIL—5 TERM—BYPASS—JAW CLAMPING—INTERNAL HEX HEAD
Z911531-AC COMPLETE BLOCK ASSEMBLY—9550/9551—200 AMP
350 KCMIL—7 TERM—BYPASS—JAW CLAMPING—INTERNAL HEX HEAD
Z911500-AC COMPLETE BLOCK ASSEMBLY—9700/9701—200 AMP

OLD SIZE FRONT ASSEMBLY OLD SIZE FRONT ASSEMBLY


PART NUMBER PART NUMBER
RINGLESS RING TYPE
Z912269-SC 7487 (HEIGHT—101/2″) Z912291-SC 7490 (HEIGHT—101/2″)
Z912015-SC 7040 (HEIGHT—14″) Z912040-SC 7018 (HEIGHT—14″)
Z901994-SC 7021 (HEIGHT—14″) Z902198-SC 7017 (HEIGHT—14″)
Z909745-SC 9550,9700,7421 (HEIGHT—17 ″) — —

NEW SIZE FRONT ASSEMBLY NEW SIZE FRONT ASSEMBLY


PART NUMBER PART NUMBER
RINGLESS RING TYPE
Z902231-SC 7487 (HEIGHT—11 1/2″) Z900079-SC 7490 (HEIGHT—111/2″)
Z909408-SC 7040 (HEIGHT—15 1/2″) Z902201-SC 7018 (HEIGHT—151/2″)
Z912197-SC 7021 (HEIGHT—15 1/2″) Z912173-SC 7017 (HEIGHT—151/2″)
Z902210-SC 9550,9700,7421 (HEIGHT—181/2″ ) — —
Z902134-SC 9551,9701,7422 (HEIGHT—19″ ) — —

65
M AT E R I A L S & F I N I S H E S

MATERIALS
STEEL QUALITY
The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the
best possible weather proofing. *American Iron and Steel Institute.

STEEL SHEET
16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.
(AISI G90)
14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.

ALUMINUM EXTRUSION
Wire-Terminals: Alloy; 6061-T6, Tin-plated for Cu/Al wire.
Bus Bar: Alloy; 6101-o & 6063-O

ALUMINUM SHEET
3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thick-
ness range from .064 — .125

COPPER SHEET & BUS


Electrolytic copper with tin plating in most applications.

INSULATING MATERIALS
In most units support bases for current carrying components are molded from fiberglass rein-
forced high-strength, track resistant, thermoset polyester molding compounds.
Clear or black safety shields and polarity barriers are molded from high-strength, track resistant,
polycarbonate molding compounds.
Various sheet insulating materials as appropriate for the application are utilized in the fabrication
of flat, formed and punched component parts and barriers.

FINISH
PROCESS
Light gray “state of the art” electrostatically applied powder paint offers a durable, non-fading
finish. For further information concerning the chemical analysis of the weather resistant finish,
please contact the factory.

METAL FASTENERS
Zinc-coated with a chromate dip.

RATING
NEMA RATING
All Milbank meter sockets, CT cans and meter socket / breaker units have a Nema 3R rating.

66
C O N D U I T & A M PA C I T Y I N F O R M AT I O N
MAXIMUM NUMBER OF CONDUTORS IN CONDUIT*
CONDUCTOR
CONDUIT TRADE SIZES (INCHES)
SIZE
TYPE
AWG,MCM 1
⁄2 3
⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4
14 6 10 16 29 40 65 93 143 192
12 4 8 13 24 32 53 76 117 157
RHW & RHH 10 4 6 11 19 26 43 61 95 127 163
(without outer covering) 8 1 3 5 10 13 22 32 49 66 85
THW 6 1 2 3 7 10 16 23 36 48 62

3 1 1 2 4 6 10 15 23 31 40

1/0 1 1 2 3 5 8 12 16 21
TW 2/0 1 1 1 3 5 7 10 14 18
THW 3/0 1 1 1 2 4 6 9 12 15
FEPB (6 thru 2), 4/0 1 1 1 3 5 7 10 13
RHW and 250 1 1 1 2 4 6 8 10
RHH 300 1 1 1 2 3 5 7 9
(without outer cover- 350 1 1 1 3 4 6 8
ing) 400 1 1 1 2 4 5 7
RH, THHW 500 1 1 1 1 3 4 6
600 1 1 1 3 4 5
700 1 1 1 2 3 4
750 1 1 1 2 3 4
*This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C.

* ALLOWABLE AMPACITIES OF INSULATED COPPER & AMPACITY CORRECTION FACTORS


ALUMINUM CONDUCTORS (3W IN CONDUIT)75°°C(167°°F)
AMBIENT CORRECTION AMBIENT
A = Size: AWG/MCM TEMP.C°° FACTOR TEMP.F°°
*CU AL or Cu-Clad AL B = Ampere Rating for 21 - 25 1.05 70 - 77
Insulation Types: 26 - 30 1.00 79 - 86
A B A C FEPW, RH, RHW, 31 - 35 .94 88 - 95
18 — — —
THW, THWN, XHHW,
36 - 40 .88 97 - 104
16 — — — USE, 2W.
C = Ampere Rating for 41 - 45 .82 106 - 113
14 20✝ — —
12 12 20✝ Insulation Types: 46 - 50 .75 115 - 122
25✝
10 35✝ 10 30✝ RH, RHW, THW, 51 - 55 .67 124 - 131
8 50 8 40 THWN, XHHW, USE 56 - 60 .58 133 - 140
6 65 6 50 (Per NEC table 310-16) 61 - 65 .33 142 - 158
4 85 4 65 66 - 70 — 160 - 176
3 100 3 75 Overall ampere ratings of U/L listed Milbank multiple position meter sockets are based on
2 115 2 90
1993 N.E.C. Manual article 220-32 and ANSI / UL-414 (except where restricted by line con-
1 130 1 100
nector size.) These requirements provide for a diversity factor / demand factor being utilized
1/0 150 1/0 120 in determining the overall (main bus / lug) rating of a gang socket. All Milbank U/L listed gang
2/0 175 2/0 135
sockets meet or exceed these diversity factor/demand factor requirements. Standard overall
3/0 200 3/0 155
4/0 230 4/0 180
ampacity ratings for U/L listed and non U/L listed gang sockets are as shown in the chart below.
Ampere ratings of meter sockets are based on the meter socket being wired with 75° C insu-
250 255 250 205
lated wire conductor, sized in accordance with Table 310-16 of the National Electric Code.
300 285 300 230
350 310 350 250 GANG SOCKET OVERALL AMPACITIES
400 335 400 270 NO. OF METER 100A / POS. 125A / POS. 150A / POS. 200A / POS.
500 380 500 310 POSITIONS AMPACITY AMPACITY AMPACITY AMPACITY
600 420 600 340 2 200A 200A 200A 200A
3 200A 225A 225A 270A
700 460 700 375
4 200A 250A 270A 360A
750 475 750 385 5 225A 285A 338A 450A
6 270A 330A 396A 528A

✝ Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk (✝✝ ) shall
not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG copper: or 15 amps for 12 AWG and 25 amps for
10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have
been applied.

67
ENERGIZATION OF ELECTRICAL EQUIPMENT

BEFORE ENERGIZING
A. Give equipment a thorough visual examination to determine that:
1) No shipping or installation damage exists.
2) Proper clearances have been maintained.
3) All connections have been made.
4) Equipment is clean and dry.
B. Make a thorough examination to verify:
1) Tightness of all bolted connections ( see table below.)
2) Manually operate all circuit breakers, switches, relays, etc.
3) Check rigidity of all mountings, bus bars and components.
4) Use test equipment to check continuity of circuitry and integrity of insulation.
C. All switches and circuit breakers should be in the off position.
D. Verify that manual meter bypass (if applicable) is in non-bypass position.
E. Install cover and/or close doors.
F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These
steps will secure the installation in case of accidental energization.

WHEN ENERGIZING
A. Use caution and follow established safety procedures:
1) Wear safety apparel.
2) Use safety equipment.
3) Take action to prevent injury to yourself and others in the event of failure of the installation.
4) Take action to prevent/decrease damage to property in the event of failure of the installation.
5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.

AFTER ENERGIZING
A. Secure the installation:
1) To prevent accidental contact with energized parts, cover all openings with approved filler devices.
2) To prevent unauthorized access, secure all covers and/or doors with approved security devices.
3) Attach/post information to advise others of potential hazards associated with the installation.

RECOMMENDED TORQUE FOR GENERAL APPLICATIONS*

NOMINAL JOINT DESCRIPTION TORQUE


HEAD
SIZE SCREW NUT TYPE ( INCH LBS. )
10 BRASS Brass Nut or Extruded Hole ALL 20-25 in. lbs.
10 STEEL CU or AL Busbar <1/8″ ALL 25-30 in. lbs
10 STEEL Steel Nut or EH; CU or AL Busbar >1/8″ ALL 30-35 in. lbs
12 STEEL Aluminum Extruded Hole ALL 30-35 in. lbs
12 STEEL Steel Nut or Extruded Hole ALL 40-50 in. lbs.
1/4 STEEL Aluminum Extruded Hole ALL 40-50 in. lbs.
1/4 STEEL Steel Nut or EH; CU or AL Busbar ALL 50-60 in. lbs.
5/16 STEEL Aluminum Extruded Hole HEX 60-70 in. lbs.
5/16 STEEL Steel Nut or EH; CU or AL Busbar HEX 100-150 in. lbs.
3/8 STEEL Steel Nut HEX 150-200 in. lbs.
1/2 STEEL Steel Nut HEX 200-250 in. lbs.

*Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first.
EH: Extruded Hole
CU: Copper
AL: Aluminum

68
WATTHOUR METERS—STANDARD FORMS—TRANSFORMER RATED OR SELF CONTAINED

SC SC TR TR TR
2 and 3-WIRE FORMS 2 and 3-WIRE FORMS 2-WIRE FORM 3S 2-WIRE FORM 3S 2-WIRE FORM 3S
1S & 2S 1S & 2S with BYPASS 5th Term. 9 o'clock with BYPASS 5th Term.6 o'clock

TR SC SC SC SC
2-WIRE FORM 3S 2 ELEMENT 2 ELEMENT 3-WIRE 2 ELEMENT 2 ELEMENT 3-WIRE
with BYPASS 3-WIRE NETWORK NETWORK FORM 12S 3-WIRE NETWORK NETWORK FORM 12S
FORM 12S 5th with BYPASS FORM 12S 5th with BYPASS
TERM. 9 o'clock 5th Term. 9 o'clock TERM. 6 o'clock 5th Term. 6 o'clock

TR TR SC SC TR
3-WIRE FORM 4S 3-WIRE FORM 4S 2 or 3 ELEMENT 2 or 3 ELEMENT 2 ELEMENT
WITH BYPASS 3∅4W Y or ∆ 3∅4W Y or ∆ 3∅4W Y or ∆
Y FORM 14S FORMS 14S & 15S Y FORM 7S
∆ FORM 15S with BYPASS ∆ FORM 24S
with BYPASS

TR TR SC SC TR
2 ELEMENT 2 ELEMENT 2∅3W, 2 ELEMENT 2 or 3 ELEMENT 2 or 3 ELEMENT
2∅3W, 2∅4W, 3∅3W 2∅4W, 3∅3W 2∅3W, 2∅4W, 3∅3W 2∅3W, 2∅4W, 3∅3W 3∅4W Y or ∆
FORM 5S FORM 5S with FORM 13S FORM 13S with Y FORM 9S
BYPASS BYPASS ∆ FORM 8S

TR = TRANSFORMER RATED
SC = SELF CONTAINED

TR TR TR
2 or 3 ELEMENT 2 ELEMENT 2 ELEMENT
3∅4W Y or ∆ 3∅4W Y 3∅4W Y
FORMS 8S & 9S FORM 6S FORM 6S
with BYPASS with BYPASS

69
METER FORMS

7446-81 REV.A—DIAGRAM A 7446-81 REV.A—DIAGRAM B 7532-61 REV.B—DIAGRAM C 7444-41 REV.A—DIAGRAM D


1∅2W with 1 P.T. & 1 C.T. 1∅3W with 1 C.T. 1∅3W with 2 C.T.’s 1∅3W or 3W Network with 2 C.T.’s
Single Stator Meter(2W1∅) - Form 3S Single Stator Meter(2W1∅) - Form 3S Single Stator Meter(3W1∅) - Form 4S 2 Stator Meter - Form 5S
5T Socket, Test Switch #TS04-0101 5T Socket, Test Switch #TS04-0101 6T Socket, Test Switch #TS07-0105 8T Socket, Test Switch #TS07-0105

DIAGRAM A DIAGRAM B DIAGRAM C


DIAGRAM D

(ALT.LOC.)
(ALT.LOC.)

P1 P N + C1
+ C1
P1 PN C1 C1 + + + +
P1 P2 C1 C2 C2 C2 P1 P2 PN C1 C1 +
C2 C2

+
P.T. +
+ I + +
+
+ +
I + I + I
LINE LOAD LINE 2 LOAD C.T. C.T.

N C.T. C.T. LINE N(BONDED) + LOAD LINE N(BONDED) + LOAD


N C.T. + 2 +
(BONDED) (BONDED) 2 C.T.

7444-41 REV.A—DIAGRAM E 7444-41 REV.A—DIAGRAM F 7445-61 REV.A—DIAGRAM G 7445-61 REV.A—DIAGRAM H


3∅3W “∆” with 2 P.T.’s & 2 C.T.’s 3∅3W “∆” with 2 C.T.’s 3∅4W “Y” with 3 C.T.’s 3∅4W “Y” with 2 P.T.’s & 3 C.T.’s
2 Stator Meter - Form 5S 2 Stator Meter - Form 5S 2 1⁄2 Stator Meter - Form 6S 2 1⁄2 Stator Meter - Form 6S
8T Socket, Test Switch #TS07-0105 8T Socket, Test Switch #TS07-0105 13T Socket, Test Switch #TS10-0109 13T Socket, Test Switch #TS10-0109

DIAGRAM G DIAGRAM H
DIAGRAM E DIAGRAM F

P1 P3 PN C+ C C+ C C+ C P1 P3 PN C+ C C+ C C+ C
P1 P3 P2 C+1 C1 +
C3 C3 P1 P3 P2 C+1 C1 +
C3 C3

+ +
PT PT
PT PT + +
+ +
+ + + +
1 + + 1 + +
C.T. C.T.
1 + 1 + 2 + LOAD
2 + LOAD
C.T. C.T. LINE C.T. + LINE C.T. +
LINE 2 LOAD LINE 2 LOAD 3 + 3 +
+ + C.T. C.T.
3 +
3 + N N(BONDED)
(BONDED)
C.T. C.T.

7445-61 REV.A—DIAGRAM I 7445-61 REV.A—DIAGRAM J


3∅4W “Y” or “∆” with 3 C.T.’s 3∅4W “Y” with 3 P.T.’s & 3 C.T.’s
“Y” 3 Stator Meter - Form 9S 3 Stator Meter - Form 9S
“∆” 2 Stator Meter - Form 8S 13T Socket, Test Switch #TS10-0109
13T Socket, Test Switch #TS10-0109
DIAGRAM I DIAGRAM J

PREWIRING: If standard factory prewiring is


required, refer to wiring diagrams on this page.
Determine appropriate diagram and send a
copy with order. If custom factory prewiring is
required, specify on order. Be sure to include
meter socket catalog number, test switch make
P1 P2 P3 PN C
+ C C
+ C +
C C P1 P2 P3 PN C+ C C+ C C+ C
and catalog number, meter form number and
provide a copy of your wiring diagram.

PT
PT PT
+ + +
+ +
+ + +
1 + + 1 + +
C.T. C.T.
2 + LOAD
2 + + LOAD
LINE C.T. + LINE C.T.
3 + 3 +
C.T. C.T.
N(BONDED) N(BONDED)

70
P R O D U C T S P E C I F I C AT I O N S

ENCLOSURE INFORMATION

MILBANK ELECTRICAL METER ENCLOSURES


SPECIFICATION NOTE

All Milbank electrical enclosures in this catalog are rated “Type 3R Electrical Enclosure” unless specified otherwise on
page (Type 1 switches are listed on page 8.) All enclosures with a U/L designation are constructed per the appropriate
U/L standard and may be installed per the National Electric Code. Meter sockets are constructed per “UL 414, Meter
Sockets,” file #E30202 and per “ANSI C12.7-1993-Meter Sockets.” All test switches are constructed per “UL414, Meter
Sockets,” file # E30202 and per “ANSI C12.9-1993-Test Switches.” Power outlets are constructed per “UL 231, Power
Outlets,” file # E90945. Panelboards are constructed per “UL 67, Panelboards,” file # E32628 and “NEMA PB-1-1984-
Panelboards.” Pullout switches are constructed per “UL 1429, Pullout Switches,” file # 133062.

DEFINITIONS PERTAINING TO NONHAZARDOUS LOCATIONS

INDOOR USE

TYPE 1 ENCLOSURE:
Type 1 enclosures are intended for indoor use primarily to provide a degree of protection against limited
amounts of falling dirt.

TYPE 12 ENCLOSURE:
Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against circulating
dust, falling dirt and dripping noncorrosive liquids.

TYPE 13 ENCLOSURE:
Type 13 enclosures are intended for indoor use primarily to provide a degree of protection against dust,
spraying of water, oil, and noncorrosive coolant.

OUTDOOR USE

TYPE 3 ENCLOSURE:
Type 3 enclosures are intended for outdoor use primarily to provide a degree of protection against rain,
sleet, windblown dust, and damage from external ice formation.

TYPE 3R ENCLOSURE:
Type 3R enclosures are intended for outdoor use primarily to provide a degree of protection against rain,
sleet, and damage from external ice formation.

TYPE 4 ENCLOSURE:
Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against
wind-blown dust and rain, splashing water, hose-directed water, and damage from external ice formation.

TYPE 4X ENCLOSURE:
Type 4X enclosures are intended for indoor or outdoor use primarily to provide a degree of protection
against corrosion, wind-blown dust and rain, splashing water, hose-directed water, and damage from external ice for-
mation.

71
MILBANK ISN’T JUST METER MOUNTING...
WE HAVE A WIDE VARIETY OF PRODUCTS FOR
A DIVERSE RANGE OF ELECTRICAL NEEDS !

Residential Metering

Commercial Metering

R.V. Mobilehome Pedestals

Power Outlets

Electrical Enclosures

Marina Equipment

Roadway Lighting

Test Switches

Safety Switches

Disconnect Devices

Switch Boards

Circuit Breakers

You might also like