• IEC 62056-21 (formally IEC 61107) optical with respective flags, counts or time stamps. This includes
communications port reverse run count, reverse run energy total, reverse run
• Internal clock and calendar with battery back-up indication on LCD, elapsed hours counter, power fail
• 15 years product life counter, cumulative hours spent in anti-creep, programming
• Extensive security features counter, end of billing count, watchdog and reset counter.
• DIN double insulated, glass filled polycabonate Power flow insensitive mode, a manufacturing option, adds
case
additional security by allowing the cumulative import
• Compact design
register and TOU registers to increment for both import and
• IP53 in accordance with EN 60529 :1991
export consumption.
• 12kV impulse protection
Meters can be supplied to meet accuracy Class 1 or Class
Options 2. They are fully approved to EN 61036 : 1996 and
• RS232 communications port with multi-drop comply with EMC standard EN50081-1 : 1992.
capability
• Standard or extended terminal cover
• Pulse output
• 300 days, 30 minute load profiling recording
(A140 only)
Display Load Profile Data (A140 only)
The liquid crystal display is programmable via the The A140 stores up to 300 days of 30 minute load profile
'Power Master Unit'. A typical display showing the data, each period is tagged with status flags. The data can
contents of Rate 4 is shown below: be displayed in the Power Master Unit as a chart or report.
The number of day's data to be read back is selectable. The
chart gives mouse over viewing details of demand
recordings and flags.
Pulse Output
An optional opto-isolated pulse output can provide the
basis for an energy management system or AMR. These
pulses are output via the auxiliary terminals.
A120DIN 1A 31/3/2003
A120/140 BS
BS Multi-rate Single Phase Meter
Cumulative Register
Technical Data
Billing Historic Data (5 sets)
Security Historical Data (2 sets) Ratings 230V, 20-100A, 10-100A
Frequency 50 or 60Hz
System Connection 1phase, 2 wire
Burden 0.4W, 1.4VA
Deferred Tariff Security Data
Insulation 4kV RMS 50Hz
Tariff Structure
Impulse withstand 12kV 1.2/50µS 500ohm source
6 Seasons 7.5mm Characters
12 Season Changeover Dates
Display
24 Switching Times High contrast, wide angle
8 Exclusion Dates Product Life 15 years
Independent Day Control
300 Days Temperature -10° to + 55° C (Operational range)
Daylight Savings
Load Profile Data (A140)
End of Billing -20° to + 85° C (Storage)
Humidity Annual Mean 75% (For 30 days spread
over one year, 95%)
Pulse Output
Communications Pulse width 100ms or equal mark/space
kWh/pulse (Programmable) 10, 20, 25, 50, 100, 200, 250, 500, 1000
The meter is fitted with an IEC 62056-21 (formally
Weight 450 grams
IEC 61107) port that allows the meter to be fully Specifications Class 1 or 2 EN 61036 : 1996
configured and provides access to all metered Case IP 53 to EN 60529 : 1991
quantities, load profile (if available), security and status
data. An RS232 port, allowing configuration and Dimensions and Fixing Centres
access to the same data, is available as an option.
Pulse Output
An optional opto-isolated pulse output can provide the
basis for an energy management system or AMR. These
pulses are output via the auxiliary terminals.
Elster Metering Systems Our policy is one of continuous product development and
Oulton Road, Stone, the right is reserved to supply equipment which may vary
Staffordshire, slightly from that described.
ST15 0RS
Tel: 44 (0) 1785 812111
Fax: 44 (0) 1785 818804
www.elstermetering.com A120BS 1A 2.2003