1)Tank resting on ground.
2)Elevated tanks.
3)Underground tanks.
--Deals with the structural analysis and design of an
water tank.
--The analysis is done by the software system STAAD
Pro for staging portion.
--The design of container is done manually.
1)Circular.
2)Rectangular.
3)Intze.
4) Spherical tanks.
5) conical bottom tanks.
6) PSC Tanks.
1)Concrete.
2)Steel.
3)Minimum reinforcement.
4)Water proofing materials.
--M 30 and M 20.
--High Quality.
--Strength.
--Should be leak proof.
--Should not crack.
--Permissible stress should not exceed
the limit.
--Permissible stress in direct
tension=1000kg/cm^2.
--Tensile stress in bending=1000-1250
kg/cm^2.
--0.3% of gross cross sectional area up
to 100mm thickness.
--0.2% of gross cross sectional area for
100-450 mm thickness.
--0.2% of gross cross sectional area for
>450 mm thickness in each direction.
-The object of using them is to fill the pores of the
concrete and to obtain a dense and less
permeable concrete.
-Commonly used is HYDRATED LIME.
-Other agents like powdered chalk or talc,
Sodium silicate Zinc sulphate, Calcium
chloride etc., used.
Parameters:
-Concrete for container portion M30.
-Concrete for staging portion M20.
-Steel HYSD 415N/mm^2.
-Capacity 150000L.
-Staging 12m.
-Seismic zone-3.
-Staging to be designed with M20 and executed
with M30.
-Ground Level = 340.75m.
-Lowest water level = 352.725m.
-Maximum water level = 355.725m.
-Dead storage = .15m.
-Free board = .3m.
-Effective water depth = 3m
-Number of columns supporting the ESR = 5
-Number of columns inside container =1
-Number of braces =3
-Size of container(diameter) =8m.
-Size of column supporting ESR(diameter) = 0.4m.
-Size of column inside container(diameter) =0.2m.
-Braces =250*350mm.
-Roof beam =200*300mm.
-Floor beam =300*600mm.
-Floor ring beam =300*300mm.
Types of loads :
--Dead loads
--Imposed loads
--Wind loads
--Earthquake loads
Involves self-weight of
--Container
--Columns
--Braces
--Railing
--MS ladder
--Imposed also known live loads.